INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS

Similar documents
DOM-5. Domestic Hot Water Heaters & Boilers

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

FTIIIC-10. Domestic Hot Water Heaters and Boilers

Domestic Hot Water Heaters and Boilers FTIIIC-6

CONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS

Commercial Boilers and Domestic Water Heaters APG-5

FXLF-4. High Efficiency Water Heaters and Boilers

FXLF-9. High Efficiency Water Heaters and Boilers

Now Available with PVC & Polypropylene Vent Configurations

Boiler & Water Heater

Models 504 thru 2004 Category I with vertical vent. Models 503 thru 2003 Category IV Venting. CSA Certified Lead Content Less Than.

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

TABLE OF CONTENTS BRADFORD WHITE BOILERS

Proudly assembled in U.S.A

High Efficiency Commercial Gas Water Heaters

Raypak Residential Products

LAARS PENNANT. Economical efficiency for greater savings

Commercial Gas Water Heaters

Proudly assembled in U.S.A

LAARS MIGHTY THERM 2. High Efficiency Boilers and Volume Water Heaters

Proudly assembled in U.S.A

Models HD101 thru 2342B

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

Models HD101 thru 2342B CSA certified Low Lead Content Less Than -.25% Pb. Proudly made in U.S.A

KN-SERIES GAS-FIRED DIRECT VENT CAST IRON BOILERS KN-6 KN-10 KN-20

Peerless Boilers. Series MI. Residential Gas Boilers

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

DIVISION FINNED WATER-TUBE WATER HEATERS

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

Multiple Heater Controller TempTracker Mod+, up to 16 heaters

G315/5 Cast Iron Boiler

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

DIVISION FINNED WATER-TUBE WATER HEATERS

High Efficiency Commercial Gas Water Heaters

G315/6 Cast Iron Boiler

FINNED WATER-TUBE POOL HEATERS

G515/7 Cast Iron Boiler

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

Less Than.25% Lead Proudly Assembled in the U.S.A

G615/11 Cast Iron Boiler

RAYPAK HOT WATER & HEATING

MAXIM. Power Combustion Storage Water Heater Gas, Oil or Combination Gas/Oil. 199 to 1200 MBH 125 and 250 Gallon Tanks 15-year Warranty. PVI.

RAYPAK HOT WATER & HEATING

84 PROFESSIONAL - IN A CATEGORY ALL ITS OWN

DIVISION FINNED WATER-TUBE BOILERS

FINNED WATER-TUBE POOL HEATERS

SERIES 19A. mith PRESSURIZED WET BASE

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

Less Than.25 Pb Proudly made in the U.S.A

Triton Series High Efficiency Boiler

Series 8H. Cast Iron Gas Fired Commercial Water Boiler

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

NO ONE PUTS MORE INTO THEIR POOL HEATERS

Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander Series

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Delta T Solutions Heating Specification

940ES Tankless Water Heater

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

ULTRA HIGH EFFICIENCY. Platform with Touch Screen VERSA IC. Up to 99% thermal efficiency! Proudly assembled in the U.S.A.

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

Boilers Variable Fire Boilers

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

CAMUS FAMILY HYDRONICS LTD.

Less Than.25% Lead Proudly Assembled in the U.S.A

Advanced Heating & Hot Water Systems. High Efficiency Residential & Commercial Space Heating

940ES Tankless Water Heater

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

HHA Bellerive Apartments 7225 Bellerive Houston, Texas J. Allen Management Managing Agent

Get The Edge Over The Competition with The Summit

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

Product Data BW9 WATER BOILER SERIES B

iq251, Gen II Submittal Data

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

CAMUS. two-pass counter flow fire tube commercial boilers. for hydronic heating and hot water supply TURNDOWN RATIO! HYDRONICS LTD. Rev.

Highlights MBH 95% efficiency ENERGY STAR Qualified Low NOx emissions Space-saving design. 95% Efficient. Modulating Technology

New VERSA IC. Platform. Up to 99% thermal efficiency! Proudly made in the U.S.A

Models 1005A, 1505A, 2005A 2505, 3005, 3505, Touch Screen VERSA IC. Control Platform. Up to 99% thermal efficiency! ULTRA HIGH EFFICIENCY

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube water heaters for heating hot water.

HEATERS AND HEAT PUMPS HEATERS & HEAT PUMPS HEATERS AND HEAT PUMPS FOR SWIMMING POOLS AND SPAS

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead.

mith Mills 4500A Smith Mills 4500A 4500A-3R OIL, GAS OR COMBINATION GAS/OIL COMMERCIAL BOILER/BURNER CAST IRON

DIVISION FINNED WATER-TUBE BOILERS

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON

HHA Lyerly Apartments 75 Lyerly Houston, Texas J. Allen Management Managing Agent

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

High efficiency, cast-iron gas boiler

RAYPAK ILLUSTRATED PARTS LIST

Boiler Product Line Brochure

WATER-TUBE POOL HEATERS

Installation & Operation Manual Models: 502, 752, 1002, 1302, 1501, 1701, and 2001 Up To 5:1 Turndown

SUH-8 UNIT HEATERS. High Efficiency Heating Equipment

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

Transcription:

LCD-5

INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS The LCD Dominator Series from RBI offers competitively-priced indoor/outdoor units that meet low NOx requirements, while maintaining superior performance and serviceability. The LCD provides dependable performance in rugged environments and process applications, with a wide 225 2300 MBH range. At the heart of the unit is a sealed combustion chamber that provides the flexibility of using outside air or mechanical room air for combustion. Priced in line with the atmospheric category heaters, the LCD features smaller vent sizes, resulting in a lower total installation cost. STANDARD EQUIPMENT Finned copper tube heat exchanger, ASME 160# max WP, 2 pass Mounted & wired flow switch FM compliant gas train Sealed combustion chamber Mounted ASME relief valve (50# Boilers, 125# Water Heaters) Pump delay control Factory fired tested Barometric damper (Cat I) DEPENDABLE, EFFICIENT PERFORMANCE 82% efficient Low NOx Uginox alloy stainless steel burners Bronze headers water heaters Cast iron headers boilers On/Off, all sizes 2-stage, 600-2300 Cat I Venting (Vertical) Cat III thru-wall (up to 35 equivalent ft.) LCD Dominator Series boilers and water heaters are also available with appealing, corrosion-resistant, brushed stainless steel jacket. Ideal for outdoor or indoor installation in corrosive or harsh environments such as coastal areas and processing applications requiring wash down. NEW EASY TO INSTALL AND SERVICE Spin-off pilot service hatch for easy pilot access (sizes 750-2300) Slide-out heat exchanger Side intake, all sizes Rear intake, sizes 750-2300 Stackable frame with seismic approval (up to zone 4) Horizontal/vertical venting options Power vent option for thru-wall venting Low voltage controls Direct vent up to 35 equivalent OPTIONAL FEATURES Cupro-nickel heat exchanger Outdoor installation Stainless steel jacket Freeze protection package CSD-1

RBI products are the easiest to service and maintain. Outdoor Approved Unlike traditional atmospheric outdoor units, the fan-assisted combustion design of the LCD provides reliable operation. Outdoor concerns associated with pilot outages and poor combustion are eliminated with the LCD s proven pilot ignition and fan-assisted combustion systems. Provisions for Combustion Air Adjustment Without Jacket Panel Removal Field Reversible Headers Slide-Out Heat Exchanger for Ease of Service Convertible Horizontal/Vertical Flue Connection Air Inlet Side or Rear Connection The LCD Dominator is also available with corrosion-resistant, brushed stainless steel jacket, making it the ideal choice for harsh outdoor environments and process applications. Proven Pilot Ignition System The unique pilot ignition is safer and more reliable than the hot surface systems commonly used on other manufacturers equipment. The system employs a burner tube as a pilot. Gas is injected into a single burner and ignited by spark. A flame rod then monitors the pilot tube flame. Once the pilot is proven, the main gas valves are powered and the remaining burner tubes are safely lit. This proven system offers greater dependability and is superior to fragile HSI systems that can require frequent replacement. Smart Service Design Ease of installation and service are trademarks of all RBI water heaters and boilers. Critical components are fully accessible for faster, easier service and maintenance calls. The LCD s sealed combustion chamber features a slide-out heat exchanger for less time-consuming service and repair. At just 29.5" wide, the LCD fits easily through standard doorways. Critical components are located conveniently at the top of the boiler for easy access.

Rack and Stack The LCD offers greater flexibility and ease of installation in a space-saving design that leaves more elbowroom in the mechanical room. A rugged frame and stackable design allow for the installation of two units in one small footprint. Wide Variety of Venting Options The LCD provides added flexibility and ease of installation with multiple venting options and configurations. The sealed combustion chamber minimizes heat loss and requires less clearance from combustible walls. CONVENTIONAL OUTSIDE AIR VERTICAL SIDE WALL OUTSIDE AIR HORIZONTAL Quality Construction The LCD features a robust, compact design using the best materials for more dependable performance. Quality components include stainless steel burner tubes and solid bronze headers on water heaters. The LCD s design requires fewer blowers and gas valves to achieved staged firing. Fewer components mean reduced complexity and easier serviceability. OUTSIDE AIR HORIZONTAL/VERTICAL OUTDOOR

LEFT SIDE FRONT RIGHT SIDE NOTE: Dimensions are approximate and should not be used to rough-in equipment. DIMEMSIONS & RATINGS Net I=B=R Flue Vent Connections Ducted Air Input Output Rating Dim A Dim B Gas Water Dim C Model MBH kw MBH kw MBH kw In. mm In. mm Nat LP In. In. mm LB/LW 225 225 66 185 54 159 47 22 1/8 562 6 152.75.75 1.50 6 152 LB/LW 300 300 88 246 72 212 62 22 1/8 562 6 152.75.75 1.50 6 152 LB/LW 400 399 117 327 96 282 83 28 5/8 727 6 152.75.75 1.50 6 152 LB/LW 600 600 176 492 144 424 124 35 1/8 892 7 178 1 1 2.50 8 203 LB/LW 750 750 220 615 180 530 155 41 5/8 1057 8 203 1 1 2.50 8 203 LB/LW 1050 1050 308 861 252 742 217 58 3/8 1483 10 254 1.25 1.25 2.50 10 254 LB/LW 1200 1200 352 984 288 848 249 71 3/8 1813 12 305 1.25 1.25 2.50 12 305 LB/LW 1480 1479 433 1213 355 1045 306 71 3/8 1813 12 305 1.50 1.50 2.50 12 305 LB/LW 1650 1643 481 1347 395 1161 340 77 7/8 1978 14* 356* 1.50 1.50 2.50 12 305 LB/LW 1970 1971 577 1616 474 1393 408 97 3/8 2473 14* 356* 1.50 1.50 2.50 12 305 LB/LW 2300 2300 674 1886 553 1626 476 103 7/8 2638 14* 356* 2 2 2.50 12 305 NOTES * 14" oval to round transition piece. SHIPPING WEIGHTS Model LB/LW 225 300 400 600 750 1050 1200 1480 1650 1970 2300 lbs 325 325 430 580 725 805 875 1110 1130 1375 1435 kgs 148 148 195 263 329 365 397 504 513 624 651

HOURLY RECOVERY CAPACITY T (GPH & LPH) Model 40 F 22 C 60 F 33 C 80 F 44 C 100 F 56 C 120 F 67 C 140 F 78 C LB/LW 225 554 2096 369 1397 277 1048 221 838 185 699 158 599 LB/LW 300 738 2795 492 1863 369 1397 295 1118 246 932 211 799 LB/LW 400 982 3717 655 2478 491 1859 393 1487 327 1239 281 1062 LB/LW 600 1477 5590 984 3726 738 2795 591 2236 492 1863 422 1597 LB/LW 750 1846 6987 1230 4658 923 3493 738 2795 615 2329 527 1996 LB/LW 1050 2584 9782 1723 6521 1292 4891 1034 3913 861 3261 738 2795 LB/LW 1200 2953 11179 1969 7453 1477 5590 1181 4472 984 3726 844 3194 LB/LW 1480 3639 13774 2426 9182 1819 6887 1455 5509 1213 4591 1040 3935 LB/LW 1650 4043 15304 2695 10203 2021 7652 1617 6122 1348 5101 1155 4373 LB/LW 1970 4851 18365 3234 12243 2426 9182 1941 7346 1617 6122 1386 5247 LB/LW 2300 5660 21426 3773 14284 2830 10713 2264 8570 1887 7142 1617 6122 TEMPERATURE RISE/PRESSURE DROP Temperature Rise Across Heat Exchanger 15 F 8.3 C 20 F 11.1 C 25 F 13.9 C 30 F 16.7 C 35 F 19.4 C Flow Pres. Flow Pres. Flow Pres. Flow Pres. Flow Pres. Flow Pres. Flow Pres. Flow Pres. Flow Pres. Flow Pres. Rate Drop Rate Drop Rate Drop Rate Drop Rate Drop Rate Drop Rate Drop Rate Drop Rate Drop Rate Drop Model GPM Ft. l/s kpa GPM Ft. l/s kpa GPM Ft. l/s kpa GPM Ft. l/s kpa GPM Ft. l/s kpa LB/LW 225 24.6 0.18 1.6 0.5 - - - - - - - - - - - - - - - - LB/LW 300 32.8 0.31 2.1 0.9 24.6 0.18 1.6 0.5 - - - - - - - - - - - - LB/LW 400 43.7 0.70 2.8 2.1 32.8 0.41 2.1 1.2 26.2 0.27 1.7 0.8 - - - - - - - - LB/LW 600 65.6 1.84 4.1 5.4 49.2 1.08 3.1 3.2 39.4 0.71 2.5 2.1 32.8 0.51 2.1 1.5 28.1 0.38 1.8 1.1 LB/LW 750 82.0 3.32 5.2 9.8 61.5 1.95 3.9 5.7 49.2 1.29 3.1 3.8 41.0 0.92 2.6 2.7 35.1 0.69 2.2 2.0 LB/LW 1050 - - - - 86.1 5.16 5.4 15.2 68.9 3.41 4.3 10.1 57.4 2.44 3.6 7.2 49.2 1.83 3.1 5.4 LB/LW 1200 - - - - 98.4* 8.14 6.2 24.0 78.7 5.38 5.0 15.9 65.6 3.84 4.1 11.3 56.2 2.89 3.5 8.5 LB/LW 1480 - - - - 121.4* 7.94 7.7 23.4 97.1 5.25 6.1 15.5 80.9 3.75 5.1 11.0 69.3 2.82 4.4 8.3 LB/LW 1650 - - - - - - - - 108.2 7.02 6.8 20.7 90.2 5.01 5.7 14.8 77.3 3.77 4.9 11.1 LB/LW 1970 - - - - - - - - - - - - 107.7 8.75 6.8 25.8 92.3 6.58 5.8 19.4 LB/LW 2300 - - - - - - - - - - - - 125.7* 12.45 7.9 36.7 107.8 9.36 6.8 27.6 *Flow exceeds recommended maximum use a greater temperature rise or consult manufacturer. Cupro-Nickel heat exchanger should be considered. 7555 Tranmere Drive, Mississauga, Ontario L5S 1L4 Tel. (905) 670-5888 Fax (905) 670-5782 In the interest of product improvement, RBI reserves the right to make changes without notice. 260 North Elm Street, Westfield, MA 01085 Tel. (413) 568-9571 Fax (413) 568-9613 www.rbiwaterheaters.com