PSE-368. AH4000 SERIES 180mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

Similar documents
PSE-367C. AL4000 SERIES 100mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

PSE-805A. AL4000 SERIES 100mm chart PEN HYBRID MEMORY RECORDER

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Temperature Controllers

MICROJET RECORDER (24-CHANNEL 180mm)

Process & TeMPerATUre UniversAl input DigiTAl MeTers

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

MICROJET RECORDER (180mm)

SHIMADEN DIGITAL INDICATORS

MICROJET RECORDER (180mm)

Specification , July 2015

I/A Series 716C 1/16 DIN Temperature Controller

UDC100 Universal Digital Controller Specifications

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

UDC 700 Universal Digital Controllers and Indicator Specifications

Compact Ultra Low Temperature Chamber

Series Temperature Controller Instruction Sheet

Advanced Test Equipment Rentals ATEC (2832)

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Universal controller for panel mounting Models CS6S, CS6H, CS6L

TEMPERATURE CONTROLLER

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

CTT8 TEMPERATURE MONITOR DEVICE

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

F4 Process Controller Installation and Operation Guide

D3 Wireless temperature alarm & monitoring system family. tek-troniks

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Series Digital Controller Instruction Sheet

User Guide IM/SM3000 EN Rev. L. SM3000 Multipoint Videographic Recorder

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

MO n : 12JMC rév A

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

02/11/2015

Nov 08 PRODUCT SPECIFICATION SHEET

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

Oxygen (O2) Single-Point Gas Detection System

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

DIGITAL METERS Large Display Temperature Meters Instruction Manual

DGC-1000 DIGITAL GENSET CONTROLLER

02/11/2015

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Model 1062 Environment Monitor

TEMPERATURE CONTROL MODULE MODEL R3-TC2

Option output. 0 None. 4 RS485 communication output. 0 None. Alarm output. CH2 control output. 0 None. CH1 control output. 0 None

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

User s. Manual) Model VJUK Limit Alarm for Universal Input

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

DGC-500 DIGITAL GENSET CONTROLLER

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Analog Input Module IC670ALG630

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Two-Channel Gas Controller

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

TC515 and TC600 Installation Manual. a Winters company

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Table of Contents SECTION PAGE

Synergy Controller Application Note 125 January 2016, Revision A Tidal Engineering Corporation 2016

Temperature Controller

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Galaxy Pulsar Plus Digital Battery Plant Controller

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

Oakton TEMP 9500 Advanced Multiparameter Controller

Point recorder KS 3660

Series Multipoint Recorder. Features. The future in Data Recording Technology is available today

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock.

NGC-40 Advanced Heat-Tracing Control System

Installation Manual Tracker 221

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

NU2 Smart Power Supply (SPS) Manual

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Sentry G3 Machinery Protection Monitor

portable gas analyser

Introduction. OM-THA2

Analog Room Pressure Monitor RPC Series

Corrigo E. Second generation which contains all applications and languages

EL-USB-1-LCD Temperature Data Logger with LCD

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Carbon Monoxide Transmitter

Instruction manual Temperature Controller KT7

Dew point set DS 400

EL-OEM-3 OEM Packaged Voltage Data Logger

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

Sentry G3 Machinery Protection Monitor

EasyLog Data Logger Series

Faster Temperature (& Humidity) Chamber

High Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC.

MR SERIES CARD LOGGERS

8-Channel Thermocouple Input Ethernet Data Acquisition Module

Transcription:

AH4000 SERIES 180mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER AH4000 series is a h ybrid recorder which employs bright and clear, easy to vie w LCD display. Measuring value display is prepared as 1 point display, multi-points simultaneous display and digital display + bar graph display. Various measuring and recording settings can be easily done by front key switch and confirmed by LCD digital display. FEATURES Corresponds to SD card Equipped with SD card (sold separ ately) and it can record data, read and write setting value. Full multi range Equipped with DC voltage 10 kinds, T/C 36 kinds, RTD 12 kinds, in total 58 kinds. Easily set the r ange per channels. Easy data management by communication interface Provided with USB por t and connect with PC directly. RS232C, RS422A, RS485 and Ether net communication interface is optionally prepared. When Ethernet is selected, settings from the web and E-mail alarm notification are added. Package Software attached. By Data acquisition softw are, the use of application expands from recording/management to inf ormation processing. *Optional communication interface required. Data analysis softw are can repla y display, wave process, editing and trend display. Parameter setting softw are can manage the setting information on PC. Standard alarm display/ Printing function Set 4 types of alar m per each input points. When alarm occurs, status displa y ALM flashes and measuring value flashes at LCD operation screen. Chart end detection function available Can set the alar m operation when char t end is detected. Various programming function Process the measured data b y programming setting and displayed/recorded data of each channels are shown as programmed result data. MODELS AH47- - NNN Input point 06 : 6 points 12 : 12 points 24 : 24 points Communication interface (option) N:None E: Ethernet (Std. for US Spec) R:RS232C A:RS422A/RS485 Q:RS232C+RS485 C:RS422A/RS485+RS485 G:Ethernet + RS422A/RS485 +RS485 Alarm output / remote contacts (option) 0 : None 2 : Mechanical relay 2 points 4 : Mechanical relay 4 points ( c contact) + remote contact 5 points A:Mechanical relay 6 points + remote contact 5 points 8 : Mechanical relay 8 points ( c contact) + remote contact 10 points B:Mechanical relay 12 points + remote contact 10 points F : Mechanical relay 16 points ( c contact) + remote contact 20 points D:Mechanical relay 24 points + remote contact 20 points Power supply A:100-240V AC PSE-368

AH4000 SERIES NAME 1 Display 1. Graphic LCD display 2 Operation/ Setting Key 3 SD card slot 4 Engineering port (USB communication connector) Display measured data by digital display and analog indication by bar graph display. 1 point display 1 point display + bar graph display 6 points simultaneous display 24 points simultaneous display 2. Front key switch Setting contents can be easily registered by front key switch. Press Menu key and menu screen (list of setting items) will be displayed to graphic LCD. 3. SD card slot Save measured data to SD card b y designated inter val (Fastest 12 points: 2 sec). Also, register measuring / recording condition such as r ange, scale, chart speed and when required, setup the unit by registered conditions. 4. Engineering port at the front Connect with PC b y mini-usb cab le*. By attached setting software, you can set or change the parameter by PC. *Purchase commercialized product separately. 5. White LED chart illumination Set ON/OFF/AUTO (OFF after no operation for 3 minutes).

RECORDING EXAMPLE Periodic data printing Record the data with time, scale, chart speed, setting change mark and time line over trace printing by arbitrary interval. Time Digital recording Trace printing Data print When the latest data is required, trace printing will stop and recorded. Time Digital recording Trace printing Alarm activation and reset printing When alarm activates/reset, prints time, channel no., alarm type and alarm no. Alarm reset time Alarm reset channel number Level Alarm activation time Level Alarm type Alarm activation CH No.

AH4000 SERIES INPUT SPECIFICATIONS Measuring points: 6, 12, 24 Input types: DC voltage ---,, ±69.0mV, ±200mV, ±500mV, ±1V ±5V, ±10V, ±20V, ±50V DC current --- Max 50mA by external shunt resistor (100Ω, 250Ω) (sold separately) Thermocouple --- K, E, J, T, R, S, B, N, U, L, W-WRe26, WRe5-WRe26, PtRh40-PtRh20, NiMo-Ni, CR-AuFe, Platinel, Au/Pt Resistance thermometer --- Pt100, old Pt100, JPt100, Pt50, Pt-Co Accuracy ratings: Refer to the table of measuring range/accuracy ratings/display resolution Measuring interval:1 second/ 6 points, 2 seconds/ 12 points, Input resolution: 2 seconds/ 24 points About 1/40,000 or better (converted to reference range) Reference junction compensation accuracy: At ambient temperature:23±10 K, E, J, T, N Platinel --- ±0.5 or EMF 20µV, whichever greater Other than above --- ±1.0 or EMF 40µV, whichever greater Burnout: Burnout detection function for thermocouple input and RTD input. Upper burnout, lower burnout or burnout disabled is selectable for each input. Maximum common mode voltage: 30V AC/60V DC Common mode rejection ratio: 130dB or more (50/60Hz) Normal mode rejection ratio: 50dB or more (50/60Hz) Terminal board: Removable when wiring. DISPLAY SPECIFICATIONS Analog display: Digital display: Display item: Status display: ALARM DISPLAY Alarm display: Alarm types: Alarm settings: Alarm output: LCD bar graph 180mm Monographic type LCD (Backlight AUTO / Always ON settable) Dots : 264 x 48 dots Display area : 184 x 22mm All channels simultaneous display, year/month/day, hour/minute, alarm activate channel, chart speed display of measuring value. REC, CARD, ALM Status display ALM flash, measuring value flash at operation screen Absolute alarm, differential alarm, rate-ofchange alarm, FAIL, calendar timer, chart end. Individual settings, Max 4 levels/channel Mechanical relay 2, 6, 12, 24 points Mechanical relay 4, 8, 16 points ( c contact) STANDARDS (CONFORMITY PENDING) CE marking: UL: CSA (C-UL): Protection: EN61326-1 EN61010-1 *Under EMC test condition, variation in indication value is ±20% or ±2mV at maximum, whichever is larger. UL61010-1 2nd edition CAN/CSA C22.2 No.61010-1-04 IEC 60529 IP54 RECORDING SPECIFICATIONS Dotting interval: 5 seconds/point, 2.5 seconds/point Interlock to chart speed Recording method:wire-dot type 6-color ribbon Record/Printed color: Trace printing (default colors) 1, 7 2, 8 3, 9 Channel no. 13,19 14,21 15,21 Color Red Black Blue Channel no. 4,10 5,11 6,12 16,22 17,23 18,24 Color Green Brown Purple Digital recording Chart paper: Chart speed: Periodic data printing Alarm printing Repetition of red, black, blue, green, brown and purple Activate: Red, Reset: Green Black (channel each items color are List printing same as trace printing color) Fan-fold type Total width 200mm, total length 20m, effective chart width 180mm 1 to 1500mm / h, in 1mm/h increments (12.5mm / h can be set exceptionally) Periodic data printing: Digital printing is added to trace printing at month / day, time, channel no., data, unit Interval (hour/time) arbitrary setting. Data printing: Alarm printing: List printing: When required, interrupt trace printing and digital print time and measuring value. Alarm activated --- Time, channel no., alarm type and level Alarm reset --- Time, channel no., alarm level Memory capacity --- Max. 48 data When required, interrupt trace printing and print date, chart speed and setting information of each channel. Message printing: Print when required Up to 15 characters/message, register up to 20 characters. ON/OFF of display and recording: Select ON / OFF of display per each channel, trace recording to chart, digital recording to chart, recording to SD card Subtract printing: Record difference between reference channel and measuring value or between reference value (set value) and measuring value. Zone printing: 2 / 3 / 4 divisions Compressed/Expanded printing: Range limit is made non-linear and specific chart recording lower/upper limit is shrunk or expanded. Automatic range shift printing: Recording range is shifted automatically to another set range when measured value exceeds the current range. Overlap function available. Skip function: No display or printing of channels of which ranges are not set. CONNECTIVITY Web browser Application FTP server Ethernet SD card slot SD card USB port for PC RS422A / RS485 *Option PLC KP DB LT

GENERAL SPECIFICATIONS Rated power voltage: 100 to 240VAC, 50/60Hz Maximum power consumption: Max 65VA 100V AC balanced: 22VA, 240V AC balanced: 31VA Normal operation condition: Ambient temperature range: 0 to 50ºC (20 to 65%) Ambient humidity range: 20 to 80%RH (5 to 40ºC) Power voltage:90 to 264V AC Power frequency:50/60hz ±2% Attitude: forward tilting 0º, Case material: Case color: Mounting: Weight: Terminal screw: OPTIONS ACCESSORIES backward tilting 0 to 30º, left/right 0 to 10º Door --- Aluminum die-casting Front panel --- Glass Case --- Cold-rolled steel plate Door--- Black (equivalent of Munsell N3.0) Glass--- Clear and colorless Case --- Gray (equivalent of Munsell N7.0) Panel mounting About 7.6kg Power terminal, Protective conductor terminal --- M4.0 Measuring input terminal, alarm output terminal Remote contact terminal --- M3.5 Communication terminal --- M3.0 Remote contact: By external relay contact signal (digital contact: short or open), you can select chart speed or data printing Input points: 5 points, 10 points, 20 points Input signal: Digital contact signal or open collector signal Exterior output: 5V DC/2mA Function: 1. Record start/stop 2. Chart speed 3-speed switch 3. Data printing 4. List printing 5. Message printing 6. Operation record (Record ON/OFF condition to the designate location by bar line) 7. Integration/F value reset 8. Memory card (record start/stop) 9. Alarm output rest 10.Time correction Alarm output: Mechanical relay 2 points, 6 points, 12 points, 24 points Max. load 100 to 240VAC 0.2A 30V DC 0.2A Min. load 5V DC 10mA Mechanical relay ( c contact) 4 points, 8 points, 16 points Max. load 100 to 240VAC 0.2A 30V DC 0.2A Min. load 5V DC 10mA Communication interface: RS232C, RS422A, RS485, Ethernet SD Card 512MB 1GB 2GB Model : RZ-SMC512 Model : RZ-SMC1G Model : RZ-SMC2G MEASURING RANGES/ACCURACY RATING/DISPLAY RESOLUTION Input type Measuring range Reference range Accuracy ratings Display resolution mv -13.8 to 13.8mV -27.6 to 27.6mV -69.0 to 69.0mV -200 to 200mV ±69.0mV ±200mV 10µV 10µV 10µV 100µV -500 to 500mV ±500mV ±0.1% 100µV -1 to 1V ± 1V ±1digit -5 to 5V ± 5V V -10 to 10V ± 10V -20 to 20V ± 20V -50 to 50V ± 50V -200 to 300ºC K -200 to 600ºC -200 to 1370ºC ±69.0mV -200 to 200ºC E -200 to 350ºC -200 to 900ºC ±69.0mV -200 to 250ºC J -200 to 500ºC -200 to 1200ºC ±69.0mV T R S -200 to 0 to 1200ºC 0 to 1300ºC 250ºC -200 to 0 to 1760ºC 0 to 1760ºC 400ºC B 0 to 1820ºC ±0.1% -200 to 400ºC ±1digit N -200 to 750ºC -200 to 1300ºC ±69.0mV -200 to 250ºC U -200 to 500ºC -200 to 600ºC ±69.0mV -200 to 250ºC L -200 to 500ºC -200 to 900ºC ±69.0mV W-WRe26 WRe5-WRe26 0 to 2315ºC 0 to 2315ºC ±69.0mV ±69.0mV 0 to 290ºC NiMo-Ni 0 to 600ºC 0 to 1310ºC ±69.0mV Platinel 0 to 350ºC 0 to 650ºC 0 to 1390ºC ±69.0mV PtRh40-PtRh20 0 to 1880ºC ±0.2% CR-AuFe 0 to 280 K ±6.9mV ±1digit 0.1 K Au/Pt 0 to 1000ºC -140 to 150ºC 160Ω Pt100-200 to 300ºC 220Ω -200 to 649ºC 340Ω -200 to 850ºC 400Ω Old Pt100-140 to 150ºC 160Ω ±0.1% -200 to 300ºC 220Ω ±1digit -200 to 649ºC 340Ω -140 to 150ºC 160Ω JPt100-200 to 300ºC 220Ω -200 to 649ºC 340Ω Pt50-200 to 649ºC 220Ω Pt-Co 4 to 374K 220Ω ±0.15% ±1digit 0.1 K DC voltage Thermocouple RTD Note: The accuracy ratings are converted into the measuring range under reference condition. Thermocouple input does not contain reference junction compensation accuracy. K, E, J, T, R, S, B, N : IEC584(1977, 1982), JIS C 1602-1995, JIS C 1605-1995 W-WRe26, NiMo-Ni, Platinel, PtRh40-PtRh20, CR-AuFe, Au/Pt : ASTM E1751 WRe5-WRe26 : ASTM E988 U, L : DIN43710-1985 Pt100 : IEC751(1995), JIS C 1604-1997 Old Pt100 : IEC751(1983), JIS C 1604-1989, JIS C 1606-1989 JPt100 : JIS C 1604-1981, JIS C 1606-1986, Pt50 : JIS C 1604-1981 Pt-Co : CHINO

APPLICATION SOFTWARE (standard attached) Data Acquisition Software You can acquire data easily to your PC. *Optional communication interface required Parameter Setting Software Control the setting information at PC by using communication interface or USB port (standard equipped) List Data Screen Trend Data Screen Data Analysis Software Open the binary file recorded in the SD card, replay display and edit the trend of acquired data file. TERMINAL ARRANGEMENT Alarm relay output (24 points a contact) + remote contacts (20 points) and communication interface * RS232C and RS422A/485 are Communication terminal specified on purchase. Short between 5-7, 6-8 Measurement TC. input terminals mv(+), RTD(A) terminals Remote contact terminals (option) Power/protective conductive terminals Alarm output terminals (option) TC. mv(+), RTD(A) terminals Ethernet connector (option) Alarm relay output (16 points c contact) + remote contacts (20 points) and communication interface Communication terminal * RS232C and RS422A/485 are specified on purchase. Short between 5-7, 6-8 Measurement TC. input terminals mv(+), RTD(A) terminals Remote contact terminals (option) Power/protective conductive terminals Alarm output terminals (option) N.C terminal TC. mv(+), RTD(A) terminals N.C terminal DIMENSIONS Ethernet connector (option) Panel cutout 360 218 1 0 360 *Max216, When alarm output/remote contacts unit and communication unit are added 281 1 0 Unit :mm Specifications subject to change without notice. Printed in Japan (I) 2011. 12 32-8 KUMANO-CHO,ITABASHI-KU,TOKYO 173-8632 Telephone : +81-3-3956-2171 Facsimile : +81-3-3956-0915 E-mail : inter@chino.co.jp Website : www.chino.co.jp/ $