freedom residential pendent sprinkler vk466 (K5.2)

Similar documents
TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

TECHNICAL DATA vk470 (K3.0)

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

FREEDOM RESIDENTIAL PENDENT LEAD FREE SPRINKLER VK4700 (K3.0) TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK460 (K5.8) TECHNICAL DATA

freedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

freedom residential Upright sprinkler vk467 (k4.9)

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

TECHNICAL DATA. The Viking Corporation s Web site at Overall Length (Sprinkler Body): 2-5/16 (59 mm)

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

freedom residential horizontal sidewall sprinkler Vk450 (k4.2)

microfast quick response Pendent sprinkler VK302 (K5.6)

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

TECHNICAL DATA. Page 1 of 6

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

freedom residential concealed pendent sprinkler vk474 (K5.8)

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

freedom residential concealed pendent sprinkler VK488 (K3.0)

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK498 (K5.8) TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

micromatic standard response Upright sprinkler VK100 (K5.6)

freedom residential concealed pendent lead free sprinkler

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

microfast sr/qr extended coverage pendent sprinkler

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK120 (K8.0) TECHNICAL DATA

standard response/ quick response extended coverage

Page 1 of 7. Form No. F_ Rev Replaces Form No. F_ Rev 17.1 (added 205deg version)

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

standard response large orifice dry

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2)

standard response elo upright sprinkler

microfast quick response extended coverage hsw sprinkler vk606

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

quick response horizontal sidewall sprinkler vk360 (K8.0)

FREEDOM RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK480 TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

FREEDOM RESIDENTIAL CONCEALED PENDENT LEAD FREE SPRINKLER VK4570 (K4.9) TECHNICAL DATA

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

freedom residential concealed pendent Sprinkler vk458 (K7.4)

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

Microfast quick response Fusible element hsw sprinkler

micromatic Standard response Horizontal Sidewall sprinkler

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

Page 1 of 7. Replaces Form No. F_ Rev 16.3 (Added 16X22 and 18X20 coverage areas)

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

standard response fusible link sidewall sprinkler VK112 (K5.6)

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

TECHNICAL DATA. Page 1 of 5

standard response dry horizontal sidewall sprinklers

standard response dry horizontal sidewall sprinklers

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

standard response Fusible Link Upright sprinkler VK204 (K8.0)

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

standard response elo upright and pendent sprinklers (storage-density/area)

standard/quick response extended coverage light and ordinary hazard elo sprinklers

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

quick response Sprinkler 105a October 25, 2010

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

Transcription:

Page 1 of 5 1. DESCRIPTION Viking Freedom Residential Pendent Sprinkler VK4 is a thermosensitive, glass-bulb residential sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Chart. The orifice design, with a K-Factor of 5.2 (74.9 metric*), allows efficient use of available water supplies for the hydraulically designed fireprotection system. The fast response type glass bulb and special deflector combine speed of operation and area of coverage to meet residential sprinkler standards while being aesthetically pleasing. 2. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW UL Classified to: NSF/ANSI Standard 1, Drinking Water System Components (MH4034) Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed. 3. technical data Specifications: Available since 200. Minimum Operating : Refer to the Approval Chart. Maximum Working : 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2 (15 mm) NPT Nominal K-Factor: 5.2 U.S. (74.9 metric*) * Metric K-factor measurement shown is for when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -5 F (-55 C) Overall Length: 2-1/4 (5 mm) Material Standards: Frame Casting: Brass UNS-C4400 or QM Brass Deflector: Brass UNS-C23000 or Phosphor Bronze UNS-C51000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Polytetrafluoroethylene (PTFE) Tape Compression Screw: Brass UNS-C3000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For ENT coated sprinklers: Belleville spring - Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Sprinkler: Base Part No. 1371 Order Sprinkler VK4 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester M-/B, and ENT = JN Temperature Suffix: 155 F ( C) = B, 175 F (79 C) = D For example, sprinkler VK4 with a Brass finish and a 155 F ( C) temperature rating = Part No. 1371AB. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: A. Standard Wrench: Part No. 275M/B (available since 2017) B. Wrench for Recessed Pendent Sprinklers: Part No. 1355W/B** (available since 200) **A ½ ratchet is required (not available from Viking). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) Form No. F_090 17.10.05 Rev 17.1 Replaces Form No. F_090 Rev 15.1 (Replaced wrench 109W/B with 275M/B.)

Page 2 of 5 4. Installation Refer to appropriate NFPA Installation Standards. 5. Operation During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire.. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availability The Viking Model VK4 Sprinkler is available through a network of domestic and international distributors. The Viking Corporation web site for the closest distributor or contact The Viking Corporation.. Guarantee For details of warranty, refer to Viking s current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating 1 Maximum Ambient Ceiling Temperature 2 Bulb Color Ordinary 155 F ( C) 100 F (3 C) Red Intermediate 175 F (79 C) 150 F (5 C) Yellow Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion Resistant Coatings 3 : ENT 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For ENT coated sprinklers, the waterway is coated. Note that the spring is exposed on sprinklers with ENT coating. Protective Sprinkler Cap Wrench Flat Form No. F_090 17.10.05 Rev 17.1 Figure 1: Standard Sprinkler Wrench 275M/B

Page 3 of 5 Approval Chart Viking VK4, 5.2 K-Factor Residential Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to NFPA 13, 13R or 13D 2013 Editions Sprinkler Base Part Number 1 SIN NPT Thread Size Nominal K-Factor Overall Length Maximum Water Working Inches Inches mm U.S. metric 2 mm 1371 VK4 1/2 15 5.2 74.9 175 psi (12 bar) 2-1/4 5 Max. Coverage Area Ft.X Ft. (m X m) 12 X 12 (3.7 X 3.7) X (4.3 X 4.3) 1 X 1 (4.9 X 4.9) 1 X 1 (5.5 X 5.5) 20 X 20 (.1 X.1) Ordinary Temp Rating (155 F/ C) Flow GPM (L/min) 17 (4.4) 20 (75.7) PSI (bar) 10.7 (0.74). (1.02) Intermediate Temp Rating (175 F/79 C) Flow GPM (L/min) 17 (4.4) 20 (75.7) PSI (bar) 10.7 (0.74). (1.02) Deflector to Ceiling 1-1/ to 2 inch Installation Type Standard surface-mounted escutcheons, the Microfast Model F-1 Adjustable Escutcheon, or recessed with the Micromatic Model E-1, E-2, or E-3 Recessed Escutcheon Listings and Approvals 3 4 and 10 NYC NSF 7 Footnote 5 Footnote Minimum Spacing Ft. (m) 1 Part number shown is the base part number. For complete part number, refer to Viking s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4 Listed by Underwriter s Laboratories, Inc. for use in the U.S., Canada, and European Union. 5 Meets New York City requirements, effective July 1, 200. For areas of coverage smaller than shown, use the Flow and for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum Flow and used. 7 UL Classified to: NSF/ANSI Standard 1, Drinking Water System Components (MH4034). Approved Finishes are: Brass, Chrome, White Polyester, and Black Polyester 9. 9 Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. 10 Approved finish is Electroless Nickel PTFE (ENT). ENT is C-UL-US-EU Listed as corrosion resistant. ENT is available with standard surface-mounted escutcheons or the Micromatic Model E-1 Recessed Escutcheon. (2.4) Form No. F_090 17.10.05 Rev 17.1

Page 4 of 5 Figure 2: Wrench 1355W/B for Recessed Sprinkler VK4 Figure 3: Sprinkler VK4 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Form No. F_090 17.10.05 Rev 17.1 Figure 4: Sprinkler VK4 Dimensions with the Model E-1 and E-2 Recessed Escutcheons

Page 5 of 5 DESIGN CRITERIA (Also refer to the Approval Chart.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Sprinkler VK4 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in the Approval Chart for NFPA 13D and NFPA13R applications for each listed area of coverage, or Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the design area in accordance with sections.5.2.1 or..2.1.2 of NFPA 13. Minimum distance between residential sprinklers: ft. (2.4 m). IMPORTANT: Always refer to Bulletin Form No. F_09199 - Care and Handling of Sprinklers. Also refer to Form No. F_00190, F_00, and F_00415 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Form No. F_090 17.10.05 Rev 17.1 Replaces Form No. F_090 Rev 15.1 (Replaced wrench 109W/B with 275M/B.)