XL200L/600L/700L GPRS Control Panel

Similar documents
XV 210 GPRS Control Panel

XT-iP 210 Control Panel

XTO-IP ALARM PANEL. Description. Supervised Wireless Technology. Features

Panel XT210/610/ Description. Supervised Wireless Technology

Description Supervised Wireless Technology PRODUCT SPECIFICATION SHEET

Panel XTO210/610/710 GPRS

Indoor MotionViewer IMV 200/601/701

ISMV STREAMING MOTIONVIEWER

OMV OUTDOOR MOTION VIEWER

Badge Reader BR Installation Guidelines. Product Summary

Wireless External Alarm

SZ-PIR04N ZigBee Motion Detector Installation Guide

1100D Wireless Receiver

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

2 x screws. 2 x wall plugs

1100X Wireless Receivers

Wi-Fi DOOR/WINDOW SENSOR

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

Optima ZigBee Thermostat

Videofied Distributor Asfales - Oude Molenstraat Mol (b) (0)

Atomic Digital Office Clock

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

Wireless Weather Station

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

ADT. Pulse 2017ADT LLC

Rev D 3/20/17

Automatic Dimming Mirror with HomeLink

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

OPERATION MANUAL WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT.

Smart THERMOSTAT. Installation Manual

Impassa CDMA Module INSTALLATION GUIDE

ShockLink. Important Product Information.

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

Smart Hub THERMOSTAT. Installation Manual

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

Pet Immune SAW PIR Motion Sensor

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

InTemp CX Temperature Logger (CX40x) Manual

Wireless Outdoor Air Reset Adaptor PN:

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

Draft - develop and review

1 Copyright 2015 Alarm.com. All rights reserved. Rev 3.4

1 Copyright 2014 Alarm.com. All rights reserved. Rev 3.3

S541.RF 4G Product Guide

PET IMMUNE PIR MOTION DETECTOR

SkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL

Touchscreen Comfort Control

1126 Series Ceiling Mount PIR Motion Detector

1134 Wireless Wiegand Module INSTALLATION AND PROGRAMMING GUIDE

Water Sensor. Model CFWS10

Nest x Yale Lock Programming/Troubleshooting Guide

HOBO MX Temp/RH Data Logger (MX1101) Manual

Yale Real Living Key Free Push Button Deadbolt B1 with Installation and Programming Instructions

Intelli-Time Alarm Clock model 13041RM

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

Installer Guide smart connect

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

Features and content. This is where air comes into your detector.

nextouch Touchscreen and Push Button Access Cylindrical Lock Installation and Programming Instructions

COMPLETE SETUP AND PROGRAMMING MANUAL FOR XT610/XTX610/XTO610 GPRS PANELS

Tech Support Line: (715) Concord 4 RE927X

Xtender Panel Installation Guide Specification and Features

Installation Guide. Model TBZ48A Battery Powered Z-Wave Thermostat. This thermostat is compatible with most HVAC systems, including the following:

Contents. User Manual GA-U-1. VultureNet: Long Range System

EL-TSTAT Owner s Manual

Caught a critter in the act?

WIRELESS ALARM SYSTEMS CATALOGUE.

EN1221S-60 Waterproof Pendant Installation and Operation Manual

ecobee 3 Quick Start Guide Installation Guide DRAFT

1164/1164NS Wireless Smoke Detector INSTALLATION AND PROGRAMMING GUIDE

Smoke Bridge Owner s Manual

Installer Guide smart connect

1125 PIR Motion Detector

Security System Videofied - Model XL GPRS. Made by RSI VIDEO TECHNOLOGIES

Projection Alarm Clock

SuperCELL Model SC500-H-SM User s Information

Smart Radon Detector with Indoor Air Quality Sensors

Smart Radon Detector with Indoor Air Quality Sensors Version 1, May 8, 2018

RE6100 Series Helix Security and Automation Platform E I D

Installation Guide

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

FTN-RRHW/FTN-RRIX FTN-RR2G/FTN-RRDS

Yale Real Living Push Button Deadbolt Installation and Programming Instructions (YRD210)

Yale Real Living Key Free Touchscreen Deadbolt Installation and Programming Instructions (YRD240)

Regulatory Compliance and Safety Information for Contol4 Model C4-16AMP3-B.

1164/1164NS WIRELESS SMOKE DETECTOR

Monnit Wireless Local Alert. User s Guide

Yale Real Living Push Button Lever Installation and Programming Instructions (YRL210)

Remote Notification System Instruction Manual

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

Technical support is also available by or by phone: (North America) (International)

EN1221S-60 Waterproof Pendant Installation and Operation Manual

AdvisorOne Quick Operation Guide

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions (YRD220)

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Home Comfort Control with Wi-Fi Model 8910W READ AND SAVE THESE INSTRUCTIONS. Owner s Manual. Includes Operating Instructions and Warranty Information

powered by Note: This manual applies to several packages. As such, some parts and some steps may not pertain to the package that you purchased.

Yale Real Living Touchscreen Lever Installation and Programming Instructions (YRL220)

Performance Thermal Binder

Transcription:

Doc. - Ref. 220-XLL Version : June 2014 Description The XLL GPRS alarm panel is a Videofied wireless, battery operated security system. The control panel is designed for residential and small commercial security applications where video verification is needed or desired. The control panel is powered by eight 1.5-volt alkaline batteries that last up to four years, with normal system activity. A built-in siren provides status beeps. The embedded cell modem communicator reports to the monitoring station and and enables 2-way voice communication over cell to the monitoring station. A dual-tamper function is active 24 hours, whether or not the system is armed. An alarm occurs if the control panel cover is removed, or if the control panel is removed from the mounting surface. Features > S 2 View : Spread Spectrum, Videofied, Interactive AES Encrypted Wireless technology provides optimum signal integrity and security. > Compatibility : works with all Videofied wireless devices. > Supervision of all devices (except remote keyfob). > Tamper detection : 24-hour dual-tamper function provides detection for both cover and wall removal. Control panel also monitors all system device tamper switches. > Zones / Devices : 25 maximum. > Areas : 4 maximum. Area 1 predefined from factory for entry/exit delay. Areas 2, 3, and 4 can be configured as needed. Supervised Wireless Technology The XLL series, along with all Videofied devices uses patented S2View - Spread Spectrum, Videofied, Interactive, AES Encrypted Wireless technology, providing optimum signal integrity and security. Bi-directional RF communication between all system devices and the system control panel assure high signal reliability. Integrated antennas eliminate protruding wires or rods cumbersome to install and unsightly to consumers, and if damaged could lead to potential system communication problems. The panel supervises every device (excluding the remote keyfob) to monitor current open/close state, tamper condition, serial number, date of manufacture, firmware revision, and battery status. > Access codes : 20 maximum, 4-6 digits; one installer access code for on-site programming only. > Configuration/Programming : on-site using alphanumeric keypads. > Communication : reports to central monitoring stations using Frontel. > Video verification : video resolution of 320 x 240 pixels, 0 lux sensitivity, 5-frames per second for approx. 10 seconds total recording time. 220K MPEG file. > History/Event Log : maximum 4,000 events stored in flash memory that cannot be cleared or erased.

Configuration/Programming Complete system configuration/programming can be done on-site using alphanumeric keypads. Easy to understand text on a two line, 16-characters liquid-crystal (LCD) display guides you through programming, prompting you for simple yes/no or data entry responses. Complete punctuation symbols allow for accurate website/ip address entries and device location naming. Communication The XLL reports alarms and other system events by using the Frontel protocol. Frontel provides complete system reporting information and video verification to a central monitoring station set up with the Frontel alarm receiving software. Video Verification Incorporating MotionViewer into the security system allows for video verification of intrusion alarms. When the system is armed and an intruder trips MotionViewer, the integrated camera captures a 10-second digital video clip which is sent to the central monitoring station by the control panel, which can forward them to an alert list. History/Event Log The XLL GPRS control panel records and stores all system activities and events (armings, disarmings, alarms, access codes entered, system programming changes, etc.) in flash memory, that cannot be cleared or erased. The log accumulates a maximum of 4,000 events. As additional events occur, the control panel automatically deletes the oldest event. This ensures the most recent events reside in the log. The history/event log can be viewed using an alphanumeric keypad or downloaded at the monitoring station. 2

Compatibility The XLL series panel is compatible with all the Videofied wireless devices described in this page: Indoor MotionViewer : Integrated PIR motion detector, night vision digital camera, infrared illuminators. The Indoor MotionViewer detect intruders and capture a video of the intrusion which is sent to the panel over RF. Outdoor Badge Reader with Prox-Tag: Allowing Arming/disarming of the system from outside the premices. The Prox-Tags are standard Mifare badges. Door Contact : Detect door and window open/close activity. Outdoor MotionViewer : Integrated PIR motion detector, night vision digital camera, infrared illuminators. The Outdoor MotionViewer detect intruders and capture a video of the intrusion which is sent to the panel over RF. Indoor Siren: Outdoor Siren/Strobe: Smoke Sensor: Remote Keyfob: Provide status beeps and alarm sounds throughout the premises where needed. Provide alarm sounds and visual identification of alarm site for responding authorities. Enhances protection and uses advanced smoke detection technology. Totally wireless and integrated to the security system. Allow limited system operation and panic alarm capability in a portable, convenient package. 3

Security notes / (FR) Notes de sécurité / (DE) Hinweise zur Sicherheit English Remove battery before any maintenance! WARNING, there is a risk of explosion if a battery is replaced by an incorrect type! Observe polarity when setting up the batteries! Do not throw used batteries! Bring them to your installer or a collection point. Français Retirez les piles avant toute opération de maintenance! Attention! Il y a un risque d'explosion si l'une des piles utilisées est remplacée par une pile de type incorrect! Respectez la polarité lors de la mise en place des piles! Ne jetez pas les piles usagées! Ramenez-les à votre installateur ou à un point de collecte spécialisé. Deutsch Batterien vor jeglichen Wartungsarbeiten entfernen! Vorsicht, es besteht Explosionsgefahr, wenn eine Batterie durch eine Batterie falschen Typs ersetzt wird! Achten Sie beim Einsetzen der Batterien auf die Polung! Entsorgen Sie Batterien nicht im normalen Haushaltsmüll! Bringen Sie Ihre verbrauchten Batterien zu den öffentlichen Sammelstellen. FCC Regulatory Information for USA and CANADA FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI Video Technologies may void the FCC authorization to operate this equipment. FCC Part 15.105 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: > Reorient or relocate the receiving antenna. > Increase the separation between the equipment and receiver. > Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. > Consult the dealer or an experienced radio/tv technician for help. Radio frequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65 This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: 1 This device may not cause harmful interference, and 2 This device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence. L exploitation est autorisée aux deux conditions suivantes: 1 L appareil ne doit pas produire de brouillage, et 2 L utilisateur de l appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d en compromettre le fonctionnement. 4

Operating Frequency Required Voltage Powering Current consumption Operating temperature Maximum relative humidity Dimensions (LxWxD) Weight Approvals Embedded 868/915/920 MHz Nominal voltage = 6 V Low battery limit = 4.2 V Type B : 1 external power supply with battery backup 4x 1.5 Alkaline D cells (Option 1) or Type C: 8 x 1,5 V D Alkaline batteries (Option 2) Standby (1h average) = 420 μa ; Max = 1,3 A -10 / +40 C (-14 /+104 F) 75%, without condensing 225 mm x 180 mm x 55 mm (9 in. x 7 in. x 2-1/6 in) 520 g (without batteries) EN50131-1: 2006; + A1: 2009 Grade 2 - Class II The panel must be used with a EN50131-3 certified keypad (CMA, XMA or XMB) EN50131-3: 2009 Grade 2 - ACE Type B EN50131-4: 2009 Grade 2 - Siren type W EN50131-5-3: 2005; + A1: 2009 Grade 2 EN50131-6: 2008 Grade 2 - Type C EN50130-4: 1995; + A1: 1998; + A2: 2003 EN50130-5: 1998 Class II Siren - 15 min maximum duration - Indoor use only - Can be self-powered - 105 db (A) at 1 meter EMEA SALES 23, avenue du Général Leclerc 92340 BOURG-LA-REINE FRANCE E-Mail : emeasales@rsivideotech.com North American Headquarters 1375 Willow Lake Blvd, Suite 103 Vadnais Heights, MN 55110 USA E-Mail : usasales@rsivideotech.com 5