POWER YOUR ENERGY EFFICIENCY PROGRAMS. with proven lighting controls. designed to be better.

Similar documents
ENERGY EFFICIENCY EXPERTS

INTEGRATED LIGHTING CONTROLS

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Versatile wall switch sensors maximize payback and simplify code compliance

Mini Product Guide.

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Aesthetic, energyefficient. control solutions for hospitality facilities QUICK GUIDE TO LIGHTING CONTROL FOR HOTELS

FROM THE WORLD S FIRST GFCI RECEPTACLE TO OUR GAME-CHANGING LINE OF PASS & SEYMOUR PLUGTAIL DEVICES, PASS & SEYMOUR PRODUCTS HAVE A REPUTATION FOR

Applied Lighting Controls

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

Miro Wireless Dimming and Scene Control Made Elegantly Simple

Product Bulletin for Decora Rocker Slide Controls

H-MoSS. Tomorrow s Technology Today! H-MOSS Occupancy and Vacancy Sensors. Adaptive Technology Dual Technology Ultrasonic Passive Infrared

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Applied Lighting Controls

Residential Occupancy & Vacancy Sensors

Interior Control Solutions

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

Code Review TITLE PRESENTED BY POURIA NIKNAM

Maestro Wireless dimmers, switches and sensors

Installation Instructions

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Product Specifications Dialog Room Controller* (*patent pending)

SPECIFICATION SUBMITTAL

Occupancy Sensor Selection Guide

Wireless Plug Load Control

Volume 1: Basic devices and single-space systems

DIMMING SOLUTIONS FOR EVERY NEED AND BUDGET.

LIGHTING CONTROLS

Installation Instructions

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

3 2 1 A B D F

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

Retrofit Solutions NEW. Energy-saving products for single rooms. Lutron energy-saving products. Patient Rooms. Office Spaces. Affordable Solutions

DHL-LP-LED Low Profile LED Linear High/Low Bay

design guide for wireless l i g h t i n g c o n t r o l

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Sensors and Timers P&S. designed to be better. A COMPLETE LINE FOR ENERGY SAVINGS AND CONVENIENCE.

Sensor Product Guide. Smart Sensing Control Solutions

Never forget to turn the lights off again. Motion Sensors

Ever evolving energy code requirements and the large demand for energy

Tualatin Valley Fire & Rescue Finance Department SW 70 th Ave., Tigard, OR Phone: , Fax:

FCSENS0R Occupancy Sensor. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

GRAFIK T Controls GRAFIK T

SECTION LIGHTING CONTROL DEVICES EATON S LIGHTING SYSTEMS (FORMERLY COOPER CONTROLS) VACANCY/OCCUPANCY SENSORS

Energy Management Products

National Grid Small Business Program Rebate Manual

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

Installation Instructions

SECTION. Occupancy Sensors & Lighting Control Products

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

H-MOSS Occupancy Sensors Control Units and Add-A-Relay

B. It is recognized that these standards are updated irregularly and lighting technology is changing rapidly.

East Central College

IP65 High Bay Dual Sense Sensor

0ACDT2000MV Ultasonic/Infared Occ Sensor

Infrared Ceiling Mount Sensor

Reduce lighting energy costs with controls

UNIVERSAL LIGHTING OFFERS BREAKTHROUGHS FOR BOTH ANALOG AND DIGITAL DIMMING APPLICATIONS

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

The Power To Supply... All Your Electrical Products

Lighting and Fan Speed Controls

IllumaTech Innovations

Catalog Number. Notes

IP65 High Bay Dual Sense Sensor

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

Occupancy and Vacancy Sensors

Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager. Yesterday, Today & Tomorrow

GRAFIK TTM Controls GRAFIK TTM. Wallbox Controls

Education Title Solutions

SPECIFICATION SUBMITTAL

Tri-level Control HF Sensor

Healthcare Title Solutions

Maestro Occupancy Sensor C L Dimmer

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

Abella Digital Fade Dimmer

Specifications Occupancy/Vacancy Sensors CSI ASHRAE AIA Division 16 Section 16950

LED Control Solutions. Smooth, flicker-free dimming for every application

Lutron Sensor Solutions. Lutron energy-saving light controls for your home or office. simple. affordable. energy-saving.

Maestro Occupancy Sensing Switch

ANSI/ASHRAE/IES

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

Maestro Occupancy sensing switch

Sensors and Detectors

ANSI/ASHRAE/IES

CL001 >400 Watt lamp basecase, up to 600 Watt replacement fixture $95.00 Fixture

Maestro Occupancy Sensing Switch

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

Movement-based energy control

Transcription:

POWER YOUR ENERGY EFFICIENCY PROGRAMS with proven lighting controls designed to be better.

CAPTURE ENERGY SAVINGS FOR YOUR CUSTOMERS AND GROW YOUR BUSINESS WITH PROVEN LIGHTING CONTROLS. Legrand s popular stand-alone lighting controls offer proven performance for virtually every application. You can rely on us to help solve energy code compliance issues easily and cost effectively. Wattstopper is the most trusted and comprehensive product line in the lighting control industry. Choose from: Wall Switch Occupancy and Vacancy Sensors Wired and Wireless Ceiling Occupancy Sensors Wall Box Dimmers Time Based Controls High Bay Sensors Plug Load Controls It s easy to choose the right sensor technology. Passive Infrared technology detects heat emitted from a human body in motion and relies on a clear line of sight. Ideal for: Small offices Conference rooms Ultrasonic Ultrasonic technology detects occupant movement within a room and has the ability to detect movement around partitions. Ideal for: Large restrooms Hallways Open offices Dual Technology Combines and Ultrasonic technology for hard to sense spaces when maximized sensitivity is required. Ideal for: Executive offices Large conference rooms Classrooms

STAND-ALONE LIGHTING CONTROLS WALL SWITCH SENSORS CATALOG # TECHNOLOGY VOLTAGE UNIQUE FEATURES COVERAGE NEUTRAL REQ. APPLICATIONS W VACANCY SENSOR MANUAL-ON/AUTOMATIC-OFF 10V 77V 4VPP SO BLR CR HS R PR LBR SR CS-50¹ Field Customizable 600 ft CS-350-N¹ Dual Relay, Nightlight 600 ft CS-50 CS-350-N CH-50 CH-50¹ Multi-Way 600 ft CD-50¹ Dimmer 5-500W Incandescent 600 ft CD-50 CU-50 CU-50¹ Ultrasonic Multi-Way 600 ft OCCUPANCY SENSOR AUTOMATIC-ON/AUTOMATIC-OFF ra WS-301 WS-301 3 Light Level Sensor, Optional Neutral 900 ft CONVERTIBLE OCCUPANCY SENSOR MANUAL-ON OR AUTOMATIC-ON/AUTOMATIC-OFF RS-150BA-N PW-103N PW-30 UW-100 UW-100-4 DW-100-4 DSW-301 PW-100-4 PW-301 PW-100D PW-101D PW-311 PW-311-347 UW-00 DSW-30 RS-150BA-N¹ Nightlight, 30-min. Time Delay 600 ft PW-100-4 PW-103N PW-100D PW-101D Dimmer Dimmer Light Level Sensor, Requires Power Pack Nightlight, Multi-Way, Light Level Sensor Light Level Sensor, up to 600W @ 10V or 100W @ 77V, Incandescent or -wire Fluorescent Light Level Sensor, up to 600W @ 10V or 100W @ 77V, Incandescent Magnetic Low Voltage, Electronic Low Voltage or -wire Fluorescent PW-301 3 Light Level Sensor, Multi-Way, Optional Neutral PW-30 3 Dual Relay, Light Level Sensor, Multi-Way, Optional Neutral PW-311 3 0-10V Dimmer Partial-On Option, Light Level Sensor, Multi-Way, Optional Neutral 0-10V Dimmer UW-100 Ultrasonic Light Level Sensor 400 ft² Ultrasonic Light Level Sensor, Requires Power Pack 400 ft² UW-00 Ultrasonic Dual Relay, Light Level Sensor 400 ft² Light Level Sensor, Selectable Trigger Mode, ² Requires Power Pack DW-311 3 ² 0-10V Dimmer Partial-On Option, Light Level Sensor, Multi-Way, Selectable Trigger Mode ² 0-10V Dimmer Light Level Sensor, Multi-Way, Selectable Trigger Mode, ² Optional Neutral ² PW-311-347 3 UW-100-4 DW-100-4 DW-311-347 3 DSW-301 3 DSW-30 3 ¹ Available in white, almond, light almond, ivory and black. ² Available in white, light almond, ivory, grey and black. ³ Available in white, light almond, ivory, grey, black and red. Dual Relay, Light Level Sensor, Multi-Way, Selectable Trigger Mode, Optional Neutral TI TO * 1 M H Ad

WALL BOX DIMMERS CATALOG # VOLTAGE LOAD TYPE LOAD RATING NEUTRAL REQ. FEATURES DERATING REQUIREMENTS 10V 77V 4VPP PRE S MW* radiant (Tri-color products include white, light almond and ivory; face plate kits include additional colors) -GANG / 3-GANG RH703PTC Incandescent 50-700W RH1103PTC Incandescent 50-1100W 1000W/800W RHLV703PTC Magnetic Low Voltage 50-700VA no derating reqd/650va RH703PTC RHLV703PTC RHCL453PTC RH703PTUTC RHDH163PTC RH1103PTC RHLV1103PTC RHF83PTC RHLV1103PTC Magnetic Low Voltage 50-1100VA 950VA/700VA RHFB83PTC Two-wire Fluorescent 1 0.3-5A no derating reqd/6.5a RHCL453PTC RH703PTUTC Tru-Universal Incandescent CFL, LED Incandescent, Electronic Low Voltage, Halogen 10-700W 10-450W 6-700W CFL, LED 6-450W Magnetic Low Voltage 500VA EFL 5.5A RH4FBL3PTC 5A 10A 0-10V LED, Fluorescent 30mA Incandescent 5-700W HCL453PMMTC CFL, LED 5-450W HMRTC Multi-location remote for HCL453PMMTC - no derating reqd for forward phase applications RHDH163PTC Fan Motor 0-1.6A RHKIT Interchangeable Face Plate HMKIT Multi-Location Dimmer Interchangeable Face Plate HMRKIT Multi-Location Remote Interchangeable Face Plate TITAN (Available in white, light almond, ivory, grey, black and brown) CD1103P Incandescent 40-1100W Ivory, White, Light Almond, Black, Brown, Grey, Nickel, Antique Brass, Dark Bronze -GANG / 3-GANG w/fins: 1100W/1000W w/o fins: 1000W/900W CD1103P CDVL703P CDFB83P CD3FB163P CD3FB103P77 CD4FB CDSC6 CD003P CDLV1103P CDFB163P CDFB103P77P CD003P Incandescent 40-000W CDLV703P Magnetic Low Voltage 40-700VA CDLV1103P Magnetic Low Voltage 40-1600VA CDFB83P Two-wire Fluorescent 1 0.33-8A CDFB163P Two-wire Fluorescent 1 0.33-16A CDFB103P77 Two-wire Fluorescent 1 0.33-16A CD3FB163P Three-wire Fluorescent 0.33-16A CD3FB103P77 Three-wire Fluorescent 0.33-10A CD4FB 0-10V Fluorescent Up to 60 ballasts CD4FBL 5A 10A 0-10V LED, Fluorescent 30mA CD4FBL3P 5A 10A 0-10V LED, Fluorescent 30mA CDSC6 Fan Motor 0.33-6A w/fins: 1600VA/1600VA w/o fins: 1600VA/1550VA w/fins: 8A/8A w/o fins: 7.7A/6.3A TOUCH (Available in white, almond, light almond, ivory, grey and black) TD-603 TDA-603 TDFC-1A * Multi-way capabilities vary; see website for details. 1 Mark 10, Tu-Wire, Quicktronic compatible. Hi-Lume, Compact SE, ECO-10 compatible. Additional dimmer models available; see website for details. -GANG / 3-GANG TD-603 Incandescent 40-600W 500W/400W TDA-603 Universal 5-600W TDFC-1A Fan Motor 0-1.5A TDR Touch Remote - 500W when 5 or more devices are ganged together

LEGENDS APPLICATION LEGEND SO-Small Offices BLR-Bedrooms & Living Rooms CR-Conference Rooms OO-Open Offices HS-Hallways & Stairs R-Restrooms PR-Partitioned Restrooms LBR-Lunch & Break Rooms SR-Storage Rooms E-Exteriors VOLTAGE LEGEND 10V 30V 40V 77V DIMMER FEATURES Pre-Preset MW-Multi-way 480V 4VPP = Power Pack Required S-Slide-to-off POWER PACKS ON/OFF BZ-50 BZ-150 BZ-00 AUXILIARY POWER PACKS AT-10 AT-77 BD-100E-P BD-100M BZ-50 BZ-50-347 A10C-P A77C-P CATALOG # VOLTAGE UNIQUE FEATURES BZ-50 BZ-150 BZ-00 BZ-50 BZ-50-347 BD-100E-P BD-100M AT-10 A10C-P C10E-P AT-77 A77C-P C77E-P S10/77/ 347E-P 10V 30V* 77V Automatic On/Off Automatic or Manual On/Off, Hold-On, Hold-Off Auto On/Off; rated for lighting or plug loads; load On/Off button Auto or Manual On/Off, Hold-On, Hold-Off; rated for lighting or plug loads; load On/Off button Hold-On, Hold-Off, Din Rail Mount Manual-On, Din Rail Mount Power Supply Form C Relay Power Supply Form C Relay Aux. Relay Pack CEILING/WALL MOUNT SENSORS CATALOG # TECHNOLOGY VOLTAGE UNIQUE FEATURES COVERAGE APPLICATIONS CEILING MOUNT SENSOR LOW VOLTAGE SENSORS REQUIRE POWER PACK CI-4² Low Profile 500-100 ft CI-4 CI-00/05 W Series WT Series WALL MOUNT SENSOR REQUIRE POWER PACK W CI-300/305 CI-355 UT-300/305 UT-355 DT-300/305 DT-355 CX-100/105 CI-00/05² Isolated Relay, Light Level, Low Profile 500-100 ft CI-300/305² Isolated Relay, Light Level, Low Profile 500-100 ft² CI-355¹, ² Line Voltage, No Power Pack required 500-100 ft² W series² Ultrasonic 5kHz 500-000 ft², 90 ft linear UT-300/305² Ultrasonic Isolated Relay, 40kHz 500-000 ft² WT series² Ultrasonic Isolated Relay 600-00 ft², 90 ft linear UT-355¹, ² Ultrasonic Line Voltage, No Power Pack required 500-000 ft² Isolated Relay, Light Level, Selectable Trigger Mode 1000 ft² DT-355¹ Line Voltage, No Power Pack required 1000 ft² W Well Defined Coverage 300 ft² 300-000 ft², 50-10 ft linear DT-300/305 10V 30V* 77V 4VPP CX-100/105² Isolated Relay, Light Level CB-100² Cold Location DT-00/05² CB-100 DT-00/05 * Single Phase, line to neutral. ¹ Multiple voltage options available; see website for details. ² Models with different configurations and coverage options available; see website for details. Isolated Relay, Light Level, Selectable Trigger Mode SO CR OO HS R PR LBR SR 000 ft², 90-10 ft linear 000 ft²

WATTSTOPPER HIGH BAY SENSORS CATALOG # TECHNOLOGY VOLTAGE UNIQUE FEATURES COVERAGE APPLICATIONS HIGH/LOW BAY SENSORS 10V 30V* 40V 77V 480V 4VPP HBP-111-L7 IR Remote Capability, Hold-Off Daylighting HBP-11-L7 Hold-Off Daylighting Up to 100 diameter at 40 Mounting from 15-40, snap-on aisleway masking included HBP-111-L7 HBP-11-L7 HIGH/LOW BAY ACCESSORIES HPB-EM1 HIGH BAY SENSORS HB300-B HB330-B FSIR-100 HB340-B HIGH BAY LENS OPTIONS (LENS REQUIRED) HBP-EM1 HBP-SM1 FSIR-100 HB300-B HB330-B HB340-B HB300D-B HB340D-B HB300W-B HB330W-B HB340W-B *Single Phase, line to neutral Extender module for mounting below fixture Surface mount module for mounting to bottom of fixture Remote handheld configuration tool for HBP-111-L7 Select lens for Daylighting Skylit areas desired coverage IP65 Wet Location Rating Indoor, outdoor and cold locations HBL1 Aisleway Lens 60 linear at 40 HBL1 HBL4 HIGH BAY ACCESSORIES HBL3 HBL3 HBL4 Mid-Bay, High Density Lens High Bay Lens 40 diameter at 0 60 diameter at 40 HBL3W for wet locations HBL4W for wet locations TIME BASED CONTROLS CATALOG # VOLTAGE UNIQUE FEATURES NEUTRAL REQ. APPLICATIONS 10V 40V 77V 480V 4VPP OO HS R SR EX HBEM3 HBEM3 Extender module for mounting below fixture HBEM3W for wet locations TIMERS RT-0 RT-100 CONTRACTOR PANELS LP8 RT-00 TS-400 LC8 RT-0 Preset 4 Button Countdown RT-100 Programmable Countdown RT-00 Astronomical, Dawn/Dusk Scheduling TS-400 1 Digital Countdown Timer LP8 1 LC8 Scheduled control for up to 8 single pole lighting circuits, compatible with LVSW switches Touch screen, astronomical time clock, compatible with LVSW switches LCSP- Dual single-pole relay module, two 0 Amp relays LCDP-1 LCSP- LCDP-1 ¹ Multiple voltage options available; see website for details. Double-pole relay module, one 0 Amp relay

WATTSTOPPER PLUG LOAD CONTROL CATALOG # TECHNOLOGY VOLTAGE UNIQUE FEATURES 10V 4VPP WIRELESS RECEPTACLE CONTROLS (Receptacles available in white, light almond, ivory, grey and black) WRC-TX RF transmitter sends occupancy sensor status to controlled receptacles WRC-TX WRC-15-1 WRC-15- WRC-0-1 WRC-0- WRC-15-1 1 WRC-15-1 WRC-0-1 1 WRC controls work with any 4V Wattstopper occupancy sensor 15A duplex receptacle, half controlled 15A duplex receptacle, fully controlled 0A duplex receptacle, half controlled WRC-0-1 0A duplex receptacle, fully controlled ISOLÉ IDP-3050-A IDP-3050 POWER PACKS FOR PLUG LOADS BZ-00, BZ-50 AND BZ-50-347 (SEE CENTER SPREAD) Power strip w/ Personal Sensor for automatic control of Plug Loads and 48,000A surge protection WIRELESS OCCUPANCY SENSORS CATALOG # TECHNOLOGY VOLTAGE UNIQUE FEATURES COVERAGE NEUTRAL REQ. APPLICATIONS WIRELESS OCCUPANCY SENSOR EOSW-101 EOSW-111 EORS-101 EOHR-101 EOPC-100 EOSW-10 EOSW-11 EORS-10 EOHR-10 EOKT-10 10V 77V SO CR R LBR EOPC-100 RF, self-powered 360 up to 100 ft EOSW-101 1 1-relay, RF, Manual-On EOSW-10 1 -relay, RF, Auto-On to 50% EOSW-111 1 1-relay, RF, Manual-On EOSW-11 1 -relay, RF, Auto-On to 50% EORS-101 1 1-button wireless RF switch EORS-10 1 -button wireless RF switch EOHR-101 1 Handheld 1-button RF switch EOHR-10 1 Handheld -button RF switch EOKT-101 EOPC-100 and EOSW-101, pre-paired 360 up to 100 ft EOKT-10 EOPC-100 and EOSW-10, pre-paired 360 up to 100 ft ¹ Available in white, light almond, ivory, grey and black. ² Available in white only. LIGHTING CONTROL SOLUTIONS FOR ANY APPLICATION Small Offices Bedrooms & Living Rooms Conference Rooms Open Offices Halls & Stairs Restrooms Partitioned Restrooms Lunch & Break Rooms Storage Rooms Exteriors 15 to 30% up to 50% up to 40% up to 30% 40 to 80% 50 to 70% 50 to 70% 15 to 30% 0 to 30% 0 to 40% Potential Energy Savings shown in percentage.

Tech Support: 800.879.8585 www.legrand.us/wattstopper 016 Legrand All Rights Reserved WS-13-837, rev 4/016