S3 Turbo Firewood boiler. S3 Turbo AVAILABLE WITH BROADBAND LAMBDA PROBE AND SERVO-MOTORS.

Similar documents
S3 Turbo Firewood boiler. S3 Turbo AVAILABLE WITH BROADBAND LAMBDA PROBE AND SERVO-MOTORS.

From a renowned company

PE1 Pellet. PE1 Pellet. Pellet boiler - Canada. PE1 Pellet APPROVED FOR EPA 2020 EMISSION LIMITS.

Product Range kw

SP Dual. Firewood and pellet boiler. UNIQUE. INNOVATIVE. Condensing technology for combined boilers. SP Dual.

T4 Wood chip boiler. with condensing heat exchanger and controls.

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

P4 Pellet. Pellet boiler. P4 Pellet.

P4 Pellet. Pellet boiler. P4 Pellet.

Turbomat. Wood Chip and Pellet Boilers. Turbomat TM 150/200/250 TM 300/320/400/500 STURDY CONSTRUCTION INDUSTRIAL MODEL.

Turbomat. Wood Chip and Pellet Boilers. Turbomat TM 150/200/250 TM 300/320/400/500 STURDY CONSTRUCTION INDUSTRIAL MODEL.

T4 Wood chip boiler.

arded t ecolabel!

Operating Instructions

Wood Chip and Pellet Boilers. Turbomat TM 500.

Operating Instructions

Product range. 7-1,500 kw

Heating with wood chips

Boiler controller Lambdatronic S 3200

Heating with log wood

HERZ ECO-Line Heating with logs or wood pellets

KWB CLASSICFIRE Log-wood and pellet heating system 18/28 kw

Firewood boiler S1 Turbo

Log fired heating system

Installation Instructions

Assembly Instructions

Wood chip boiler T (Touch)

Wood chip boiler TX (Touch)

english GUNTAMATIC BIoMAss BoIler HeATING range

Turbomat TM Operating Instructions. Froling GesmbH A-4710 Grieskirchen, Industriestraße 12

ETA PE-K. The pellet boiler with technology that's built to last, for larger heating needs. 35 to 90 kw. A passion for perfection.

Boiler controller S-Tronic Plus

Log wood boiler S1 Turbo

Heating with pellets kw

Lambdatronic S 3200 for firewood boiler

Turbomat TM Operating Instructions. Froling GesmbH A-4710 Grieskirchen, Industriestraße 12

WOOD CHIP HEATING HPK-RA

Heating with wood pellets kw

English. Heating with logs & wood pellets 20-40

WOOD CHIP HEATING HPK-RA

PZ35RL BIOTECH THE FUTURE OF HEATING PZ 35 RL

English. Heating with logs & wood pellets 20-40

Wood chip boiler T

HDG K SERIES. Wood pellet boiler. The perfect alternative to fossil fuels. Receive up to

Pellet suction system GA kW

Wood chip boiler T

Efficient heating that won t cost the earth

Boiler controller Lambdatronic S Touch

User friendly, compact, economical and safe

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

Dual fuel boiler SP Dual compact

Lambdatronic H 3200 for wood chip boiler

P4 Wood Pellet Boiler

Heating with wood chips & pellets

Boiler Technical Specifications (2013)

Combined boiler. for solid fuel and pellets

Max-3 Steel Shell Boiler

Pellet boiler P4 Pellet

Lambdatronic SP 3200 for dual fuel boiler

LOG BURNING BOILERS. Zeroridge Biomass Ed 17A

Technical Datasheet. FHG-S Models 28, and 45. Benefits at a Glance: State Route 22 Salem, NY 12865

Firewood Boiler S4 Turbo

Boiler controller Lambdatronic P 3200 P1 - Touch

Pellet Boiler P4 Pellet

Forward-looking and energy effi cient Biomass heating

Owner s Manual. S3 Turbo. Read and follow the operating instructions and safety information! Subject to technical change!

INSTALLATION AND OPERATION MANUAL

Biomass. Biomass solid fuel boiler range

Smart Heating Technology Ltd. U Statku 653/24, Ostrava-Bartovice Czech Republic

Pioneers of heating with biomasses

Boiler controller SPS 4000

VEDOLUX ROBUST GREEN WOOD-FIRED BOILERS


Installation, operation and care Firewood boiler Vedolux 40 UB

Technical Datasheet. P4 Pellet Boiler Models 8/15, 20/25, 32/38, 48/60. Benefits at a Glance:

Easyfire Standalone biomass pellet boiler

WOOD CHIP/PELLETS HEATING SYSTEMS

Olymp Werk GmbH c/o Grouped Renewables Ltd. PO Box 7180, Montrose DD10 0WX Tel: +44 (0) Web:

Rozp.UE2015/ kw kw

Eco Angus Wood Pellet Boilers

Distributed*and*installed*in*the*UK*by*

Technical Datasheet. P4 Pellet Boiler Models 8/15, 20/25, 32/38, 48/60, 80/100. Benefits at a Glance:

Providing sustainable energy solutions worldwide. CTC heating boilers modern technology, efficient heating

Weishaupt WG10 and WG20 gas burners LN (Low NO x ) version 2/2002 CA

Solid fuel expertise.

Pellet heating. Boilers & Burners.

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

English. Efficiency. HERZ pellet boiler with condensing technology. ɳ over 106% COndEnSATiOn

Wood chip boiler TX

* Automatic boiler for burning pellets with power 8kW r. The smallest, certified boiler * in Poland 8kW

WOOD GASIFYING BOILER ATTACK DPX STANDARD / PROFI / LAMBDA INSTRUCTIONS FOR USE WWW. ATTACK.SK

* Automatic boiler for burning pellets with power 8kW r. The smallest, certified boiler * in Poland 8kW

VestoWIN. A breath of fresh air for wood. Wood. windhager.com

A breath of fresh air for wood VestoWIN

PELLET BURNER PV 350

Owner s Manual. P4 Pellet Read and follow the operating instructions and safety information! Subject to technical change!

AIEA Presentation. Wood pellets heating systems.

Cassette inserts and fireplace doors

Multi Energy Boilers. Duo 1 & 2 Triplex 1000 & 3000 Biotriplex. Oil Gas LPG Wood Briquettes Electricity Solar thermal Solar photovoltaics

modern heating devices

Transcription:

S3 Turbo Firewood boiler S3 Turbo AVAILABLE WITH BROADBAND LAMBDA PROBE AND SERVO-MOTORS www.froeling.com

From a renowned company For more than 50 years Froling has specialised in the efficient use of wood as a source of energy. Today the name Froling stands for modern biomass heating technology. Froling firewood, wood chip and pellet boilers are successfully in operation all over Europe. All of our products are manufactured in our factories in Austria and Germany. Our extensive service network guarantees full coverage and reliability. S3 Turbo: Top-quality boiler technology at a mid-range price The S3 Turbo firewood boiler focuses on the basics. It includes many features that you would normally only find in high-end firewood boilers. Patented, cylindrical high-temperature turbulence combustion chamber for excellent combustion values. Separate pre-heating chamber door for easy pre-heating. Carbonisation gas extraction system for smoke-free reloading. Speed-regulated induced draught fan for output control and full operating safety. 2

S3 Turbo 6 1 7 8 2 9 3 10 4 11 5 The firewood boiler with special benefits: 1 2 3 4 5 6 7 8 9 10 11 Speed-regulated induced draught fan for maximum ease of use. WOS (efficiency optimisation system) for high efficiency and easy cleaning. Top quality thermal insulation. Manual adjusters (or actuators with Lambdatronic) for primary and secondary air. Large maintenance openings for easy cleaning. S-Tronic controller or Lambdatronic controller Carbonisation gas extraction system prevents flue gas from escaping during reloading. Aprons (hot cladding) to protect the inner wall of the boiler for a longer service life. Large fuel loading chamber for half-metre logs ensures long reloading intervals. Separate pre-heating chamber door for easy pre-heating. Patented high-temperature turbulence combustion chamber ensures low emissions. www.froeling.com 3

A successful design Large fuel loading chamber for half-metre logs Advantages: Easy front-loading Long combustion time Long reloading intervals The S3 Turbo can be loaded with half-metre firewood easily from the front. The loading chamber is 55 cm deep and has a generous reserve of space. Often it is only necessary to fill the boiler once a day. Strong steel guards protect the loading chamber and keep it clean. High-temperature turbulence combustion chamber Advantages: Excellent combustion values Low emissions Much more environmentally friendly Froling uses the patented, cylindrical high-temperature turbulence combustion chamber in the S3 Turbo. This means the boiler delivers excellent combustion values. The generous dimensions of the combustion zone guarantee low emissions. So by using a Froling S3 Turbo you are helping to keeping our air clean. WOS system Advantages: Even greater efficiency Easy cleaning from outside Fuel savings The WOS (efficiency optimisation system) consists of special turbulators, which are placed in the heat exchanger pipes. The lever arm mechanism ensures easy cleaning of the heating surfaces from outside. An additional benefit: clean heating surfaces lower energy consumption. 4

S3 Turbo Special carbonisation gas extraction system Advantages: No flue gas escapes during reloading The boiler room stays clean The special carbonisation gas extraction system also prevents any gas from escaping when refilling. This is applicable at every stage of combustion. Enjoy modern heating with wood! Speed-regulated induced draught fan Advantages: Easy to operate Adapts to all operating conditions Full operating safety The primary and secondary air settings are adjusted by the technician during commissioning. The functionmonitored induced draught fan enables the system to adjust to different operating conditions. This offers excellent output adjustment with full operating safety. In the S3 Turbo with broadband lambda probe the primary and secondary air settings are adjusted by means of servo-motors, ensuring that output is adapted to given requirements at every stage of combustion. www.froeling.com 5

Systematic convenience S-Tronic control Advantages: Speed regulation and function monitoring of the induced draught fan for output adjustment Integrated storage tank management Alternating display of boiler, flue gas and storage tank temperatures S-Tronic plus control Advantages: Speed regulation and function monitoring of the induced draught fan for output adjustment Integrated storage tank management Visual display with control keys for setting Can be used to control 2 mixed heating circuits Integrated boiler management Option: Froling FRA room temperature sensor / RBG 3200/RGB 3200 Touch room console Lambdatronic control Advantages: Speed regulation and function monitoring of the induced draught fan for output adjustment Lambda control with broadband lambda probe Control of primary and secondary air via 2 servomotors Integrated storage tank management Visual display with control keys for setting Can be used to control 2 mixed heating circuits Integrated boiler management The main modes of the designated heating circuit can be easily adjusted and selected using the Froling FRA room temperature sensor. The adjusting wheel allows you to change the room temperature by up to ± 3 C. The RBG 3200/RGB 3200 Touch room console makes the system even easier to use. You can control the heating system easily from your living room. The important system data is clearly displayed and changes can be set at the push of a button. 6

S3 Turbo The Lambdatronic controller controls the induced draught fan and offers the option of connecting a storage tank loading pump and a heating pump. Flue gas and boiler temperature monitoring ensures efficient combustion. NOTICE National and regional regulations requiring the use of weathercompensated controls should be observed. The Lambdatronic controllers allow for efficient energy management. Up to 4 storage tanks, up to 8 hot water tanks and up to 18 heating circuits can be integrated into the heating management system. You also benefit from the ability to integrate other means of energy production, such as solar panels. Room sensor (optional) External sensor S3 Turbo with S-Tronic WEATHER-COMPENSATED EXTERNAL HEATING CIRCUIT CONTROL Balancing valve Balancing valve Hot water Cold water H2 Hygienic layered tank AVAILABLE WITH LAMBDATRONIC Hot water S3 Turbo with S-Tronic and H2 hygienic layered tank S3 Turbo with Lambdatronic, layered tank and Unicell Cold water S3 Turbo with Lambdatronic Layered tank Unicell NT-S water heater www.froeling.com 7

Technical specifications Dimensions - S3 Turbo 18 28 36 45 L Length of boiler [mm] 1160 1160 1250 1250 L1 Total length including induced draught fan [mm] 1260 1260 1350 1350 B Width of boiler [mm] 570 570 670 670 B1 Total width including side cleaning door [mm] 680 680 780 780 H Height of boiler [mm] 1470 1470 1570 1570 H1 Total height including flue gas pipe [mm] 1530 1530 1630 1630 H2 Height of flue pipe connection [mm] 1750 1750 1850 1850 H3 Flow connection [mm] 1280 1280 1380 1380 H4 Return connection [mm] 140 140 140 140 H5 Safety heat exchanger connection [mm] 890 890 970 970 Flue pipe diameter [mm] 150 150 150 150 Technical specifications - S3 Turbo 18 28 36 45 Nominal output [kw] 22.5 31.0 36.0 45.0 Fuel loading chamber capacity [l] 140 140 210 210 Fuel loading door (width/height) [mm] 330 / 370 330 / 370 330 / 370 330 / 370 Water capacity [l] 120 120 190 190 Boiler weight [kg] 530 535 610 620 Your Froling partner: P0310413 - All illustrations intended as a guide only. We reserve the right to make technical changes without prior notice. Errors and omissions excepted. Source for third party images: www.aboutpixel.de Heizkessel- und Behälterbau GesmbH A-4710 Grieskirchen, Industriestr. 12 AUT: Tel. +43 (0) 7248 606 Fax +43 (0) 7248 606-600 G E R :Te l. + 4 9 (0)8 99 2 79 2 6-0 F a x + 4 9 (0)8 99 2 79 2 6-219 Email: info@froeling.com Internet: www.froeling.com 8

Technical data S3 Turbo 1...Boiler flow connection 3...Safety battery connection 5...Controller S-Tronic 2...Boiler return connection 4...Induced draught fan S3 Turbo 18 28 36 45 Rated heat output (without WOS system) kw 18 25 Rated heat output (with WOS system) kw 22,5 30 36 45 Electrical connection 230 V / 50 Hz / fused 16 A Output W 70 70 80 80 Boiler weight kg 520 525 610 620 Fuel loading door dimensions (w / h) mm 330/370 330/370 330/370 330/370 Fuel loading chaber capacity Litres 140 140 210 210 Water capacity Litres 120 120 190 190 Upstream resistance dt = 20 K mbar 1,8 2,1 4,5 6,3 Flue gas temperature at rated load C 150 170 150 170 Flue gas mass flow under rated load kg/s 0,013 0,018 0,026 0,033 Minimum feed pressure mbar 0,08 0,08 0,08 0,08 Permitted operating over-pressure bar 3 3 3 3 Permitted operating temperature C 95 95 95 95 Minimum return feed temperature C 55 55 55 55 Dimensions 18 28 36 45 L Boiler length mm 1160 1160 1250 1250 L1 Total length inc. induced draw fan mm 1260 1260 1350 1350 B Total width of boiler mm 570 570 670 670 H Total heigth of boiler mm 1470 1470 1570 1570 H1 Heigth of flue gas pipe connection mm 1530 1530 1630 1630 H2 Heigth gas connection. incl. elbow mm 1750 1750 1850 1850 H3 Heigth of flow connection mm 1280 1280 1380 1380 H4 Heigth of return connection mm 140 140 140 140 AR Flue gas pipe diameter mm 150 150 150 150 Boiler flow- and return connection inch 1 1/2 1 1/2 1 1/2 1 1/2 S3 Turbo A Minimum distance from front-side to wall mm 800 B Minimum distance from edge of boiler to wall mm 800 C Minimum distance from back-side of boiler to wall mm 500 D Minimum distance from edge of boiler to wall mm 200 12 Edition 2009