CHAPTER VI BUILDING PLUMBING

Similar documents
Sanitary Drainage Systems

CHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R

MATERIALS Traps TRAPS. No. IPC IRC Description

Read Only Document Not For Distribution

APPENDIX L ALTERNATE PLUMBING SYSTEMS

STACKS AND STACK VENTS

CHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof.

CHAPTER 9 VENTS SECTION

CHAPTER 10 TRAPS AND INTERCEPTORS

Pipe Sizing Table. Hydraulic Load Served (fixture units)

Level I Chapter 1 Worksheet

ProVent Systems Plumbing Fundamentals. Educational Literature. Comparison of ProVent Design Rules and The International Plumbing Code

CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE APPENDIX A - RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM 1 2 1/AC AC SS SS/CC

APPENDIX A. A 3.2 Determine the elevation of the highest. A 3.3 Subtract the sum of loss in static pressure

Building Utilities 1 Plumbing and Sanitary Systems

Wastewater. Guidelines for Sizing mscdirect.com. Call MSC today to learn about the latest LittleGiant products.

1 Exam Prep Plumber s Handbook Tabs and Highlights

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

GIANT. Little. Guidelines for Sizing. Pump Company. Sewage Pumps & Systems. Sewage Pumps & Systems

ENERGY MARKETING SERVICES

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

2012 UPC Chapter 6 Water Systems Part 2 RV

WATER HAMMER ARRESTORS & MISC. SPECIALTIES

A GUIDE TO PASSING THE PLUMBING EXAM

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

STUDENT NOTES Plan, size and layout sanitary pipe work and fixtures

Methods of Venting Plumbing Fixtures and Traps in the 2018 IPC

Plumbing. Definitions. Background Factors. Air Chambers. Air Gap (Drainage System) Air Gap (Water Distribution System) Air Lock.

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint

PLUMBING INSTALLATIONS

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2

Read Only Document Not For Distribution

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)*

PLUMBING REQUIREMENTS

2016 Plumbing Supplemental Plan Review List

GARCIA GALUSKA DESOUSA Consulting Engineers

Pro Vent TM. Provent Systems Inc Capital Circle Lawrenceville Georgia

DOMESTIC & COMMERCIAL PLUMBING SYSTEMS FURTHER INFOMATION

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7

Special Requirements For Health Care Facilities

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10.

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

Gulfport, Mississippi 21 May 2007

2015 UPC Chapter 8 Indirect Wastes RV

Drain and Vent Systems 6 CE Hours

Test Code: 8117 / Version 1

1 Exam Prep Plumbing State Contractors Practice Exam 2

Matrix of changes for the National Standard Plumbing Code July 2013

Read Only Document Not For Distribution

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES

SUBCOURSE EDITION EN5155 US ARMY ENGINEER SCHOOL CLEAR WASTE SYSTEM STOPPAGES PLUMBING VI

plumbing for greywater

CONTINUING EDUCATION UPC Definitions Code Course. 4 hours Course # ID09143 (CODE) PO Box Spokane, WA

Code 3Check Plumbing. Third Edition. INTRODUCTION u CODES u ABBREVIATIONS. Abbreviations. By michael casey, douglas hansen & Redwood Kardon

House Drainage System. Building Utility & Services

PLUMBING DESIGN GUIDELINES SECTION DESIGN GUIDELINES DUVAL COUNTY PUBLIC SCHOOLS

Mechanical System Description

CONNECTICUT. Downloaded

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

CHAPTER 10 TRAPS AND INTERCEPTORS

PLUMBING FIXTURES Reserved

DEFINITIONS CHAPTER 2

HOME INSPECTION CHECKLIST

Plumbing Technology/Plumber CIP Task Grid

2. Sanitary Plumbing General Installation Requirements

CRAFTSMAN EXAMINATION, NOVEMBER 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Is Sewer Gas Giving Your Customers the Wrong Impression?

SECTION PLUMBING

APPENDIX F. Flow Tables

Sizing Guide. For the Estimating of Flow Rates and Water Usage

The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors.

CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X X X

APPENDIX J ILLUSTRATIONS

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

2012 Virginia Plumbing Code & VRC (Plumbing) Update Training

PLAN REVIEW SUBMITTAL GUIDE

2009 IRC. and Fuel gas Provisions

RESIDENTIAL PLUMBING OVERVIEW

OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES INTERCEPTORS

PLUMBING FIXTURES CHAPTER 27

Plumbing Guidelines 2012 IBC/ANSI A

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7

AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE

4. Plumbing fixtures. a) The plumbing fixtures are from the original building. They are appear old and not to comply with ADA requirements.

DEFINITIONS CHAPTER 2

2009 IPC ,IMC Q &A ANDIFGC

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION

OFFICE OF THE CITY ATTORNEY ROCKARD J. DELGADILLO REPORT RE:

Rental Housing Inspection Guide

DEFINITIONS CHAPTER 2

SCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE

c. Direct or indirect?

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

Definitions UPC Code - Chapter 2 Definitions A-I

What Builders Need to Know about Residential Sprinkler Design

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

Transcription:

CHAPTER VI BUILDING PLUMBING 6.1. INTRODUCTION The chapter covers questions related to water demand, distribution and drainage. The basic principles for planning and installing common plumbing systems are covered. An understanding of basic aspects of the plumbing code is essential. Every city has adopted a plumbing code to protect the health and safety of its people. Building departments enforce these codes and arrange inspections of plumbing work as it's completed. Cost of plumbing systems in most homes is about 10% of the total construction cost. Every plumbing system is divided in to three parts: 1) The Drainage and vent system 2) The water service pipes and distributing pipes 3) The plumbing fixture. 6.2. WATER DEMAND The demand that will be placed on a water supply source is the first step to be calculated when designing it. The size of water supply pipes will depend on: 1) The type of flush devices to be used on the fixtures 2) The water pressure in pounds per square inch at the source 3) The length of the pipe in the building 4) The number and kinds of fixtures installed 5) The number of fixtures expected to be used at any time. the average daily water demand for several facilities is shown on Table 6.1. Table 6.1. Average Daily Water Demand Type of facility Water Demand (Gallons/day) Airport (per passenger) 3-5 Resorts (day and night, with limited plumbing, per camper) 50 Factories (per person per shift) 15-35 Highway rest areas (per person) 5 Hotels with private baths (two persons/room) 60

Multi family dwelling (per resident) 60 Hospitals (per bed) 75-125 A more complete table can be found in [1 ] The average hot water demand in the USA is assumed to be 20 gallons per person per day (gppd) for a family of two persons. An additional 15 gppd will have to be added for an increase in the number of family members. 6.3. SIZING THE DISTRIBUTION PIPES The size of piping in building water supply systems depends on the anticipated demand. A simple way of sizing the distribution pipes is using tables as shown on Table 6.2. They can be used for almost one- and two- family dwellings if the minimum water pressure is at least 5 pound per square inch (psi). Table 6.2. Size of fixture Supply Pipe Fixture type Pipe size (inches) Water closet (WC) 1/2 Shower (SH) 1/2 Bathtub (BT) 1/2 Lavatory (L) 1/2 Kitchen Sink (KS) 1/2 Clothes Washer (CWM) 1/2 Hot water heater (WH) 3/4 Hose bibb (HB) 1/2 or 3/4 The water service pipe is the most important pipe in the distribution system and must be sized first. The following restrictions must be kept in mind when sizing the pipes: 1) The minimum practical size for the water service line is 3/4 inch, and that size can be used only in certain instances 2) The minimum water service pipe size for one-and two- story building is given by Table 6.3. Table 6.3. Minimum water service pipe Number Of Bathrooms and Kitchen (Based on Tank-type Water Closets) Copper Galvanized Diameter of water service Pipe (inches) 1-2 1-2 3/4 or 1 3-4 3-4 1 5-9 5-8 1 1/4 3) The size of the water service pipe must not change when it enters the building to become the building

water main. After the water-distributing branch pipes are connected to the building main, the main can be reduced in size. 4) The water main pressure does not fall below 50 psi at any time. 5) In single - family residential buildings more than two stories high, or where the water main pressure may fall below 50 psi, use the next larger pipe size. 6) Only two fixtures can connect to a ½ inch cold water supply branch. Example 6.1 Size the cold water piping for the distribution system shown on Figure 6.1. Figure 6.1. Single - bath residence 6.4. WATER, WASTE AND DRAINAGE SYSTEMS Wastewater generated from buildings has to be transported for treatment and disposal. Almost every

building is provided with both water supply and waste pipes. Drainage in buildings has two major components: sanitary waste and storm water. sanitary waste consists of liquids discharged from plumbing fixtures. Storm water consist of rainwater, surface water or other similar liquid wastes. Sanitary and storm sewers should be separated, because sanitary waste contains a high level of pollutants. The wastewater from the building can go to a public sewer that carries sanitary waste to a central treatment plant before it is discharged to streams or rivers or the wastewater can be sent to a septic tank. The septic tank is an individual waste system for buildings in areas that are not connected to a municipal treatment system. Septic tanks are usually constructed underground, divided into two chambers using a baffle wall with an opening 18 inches below the flow line of waste. In order to calculate the total load carried by a soil or waste pipe, it is defined the Fixture Unit Value (FU). The FU for continuous flow is computed on the basis that 1 gpm of flow is equivalent to 2 FU. For semi-continuous flow, 1 FU. Table 6.4 shows the Drainage Fixture Units (DFU) for different fixtures: Table 6.4. Drainage Fixture Units Fixture Type Bathroom group consisting of water closet, lavatory, bidet and bathtub or shower DFU Automatic clothes washer, domestic 2 Kitchen sink, domestic 2 Lavatory 1 Water closet, Flushometer tank, public or private 4 6 All plumbing fixtures discharge the used water to the drainage system. Sizing the drain and waste pipes can be done following certain rules: 1) According to the Standard Plumbing Code, the maximum number of fixture units (F.U.) to connect to any part of the building drain or horizontal fixture drains (¼ inch fall per foot) is given by Table 6.4. Table 6.4. Maximum Number of Fixture Units Pipe Diameter (inches) Fixture Unit Valve 2 21 2 1/2 24 3 27 (Not over two W.C.) 4 216 2) The minimum size of a building sewer shall not be smaller than 4 inches. 3) For additions to residential buildings, if it is necessary to install the sewer line outside and around an

existing structure, such line shall be considered as a horizontal branch. 4) Always use the minimum sizes required by the code. Using larger waste pipes than required is not recommended. 6.5. TRAPS Traps provide a water barrier against the infiltration of sewer gases into the building. As shown in Figure 6.2, the water in the trap block the pipe so that gases could not pass. Figure 6.2. Fixture Trap When water moves into the trap, the mass of water act as a plunger, creating higher pressures in from of it and negative pressures behind. The high pressure might force sewer gas through the water in other traps and the negative pressure could suck the water from the trap, leaving it open to gas passage. These effects a can be eliminated through the proper installation of vents. All plumbing fixtures must be equipped with a trap. The most common trap is the shown on Figure 6.2 and is called P-trap. When installing fixture traps, the following rules must be observed: 1) Fixture traps shall be self cleaning and can not depend on movable parts to retain the water seal. 2) No trap outlet can be larger than the fixture drain to which it is connected. 3) The water seal shall be between 2 and 4 inches. 4) All traps shall be installed level in relation to their water seal (Figure 6.3)

Figure 6.3. Trap installation a) correct b) incorrect 5) No fixture can be double trapped. 6) For sinks, lavatories, showers, bathtubs and similar fixtures, the maximum allowable vertical drop from the fixture waste outlet to the trap water seal can not exceed 24 inches (18 inches in some codes). (Figure 6.4) Figure 6.4. Maximum Vertical Drop 7. The vertical drop of the pipe serving fixtures with integral traps, as water closets and similar fixtures shall not exceed 24 inches (Figure 6.5).

Figure 6.5. Vertical Drop for fixtures with Integral Traps. 6.6. THE VENT SYSTEM Vents are used to relieve the pressure that builds up as water from plumbing traps is discharged into the sanitary drainage systems. The following problems are presented due to inadequate sizing and arrangement of vent pipes: 1) Water closets need several flushes to remove content from the bowl. 2) Back pressure within the drainage pipes may force sewer gases through the liquid trap seal and into the building. 3) Low pressure in the drains may cause siphoning in the traps. This can occur in plumbing fixtures located farther from a vent pipe than is permitted by the code. 4) Plumbing fixtures drain slowly. In order to provide efficient ventilation to the drainage system, it is necessary to use individual or continuous vents. However, plumbing codes permit the use of circuit and loop vents, which do not provide an individual vent for every plumbing fixture. The following definitions will be used: Vent stack: Is a vertical pipe installed to provide circulation to and from the drainage system. Stack vent: A single main pipe is extended above the highest horizontal drain for a group of fixtures. Each fixture drain must connect independently to the stack. Figure 6.6 shows an example of stack venting.

Figure 6.6. Stack Venting. Soil stack: is the vertical section of pipe in a plumbing system that takes waste from water closets, with or without waste from other fixtures, to the building drain (Figure 6.7) Figure 6.7. Soil Stack. Common vent: is a vertical vent that serves two fixture drains that are installed at the same level. (Figure 6.8).

Figure 6.8. Common Vent. Relief Vent: lets air circulate between the drainage system and the vent of a plumbing system (Figure 6.9). Figure 6.9. Relief Vent. Circuit Vent: serves more than two fixtures and extends from the front of the last fixture connection of a horizontal branch to the vent stack. (Figure 6.10).

Figure 6.10. Circuit Vent. The maximum distance of fixture trap from vent for a slope of ¼ inches per foot, is given in Table 6.5 as per the Standard Plumbing Code. Table 6.5. Distance of Fixture Trap from Vent. Size of Fixture Drain (inches) Size of Trap (inches) Distance (feet) 1 1/4 1 1/4 3 1/2 1 1/2 1 1/4 5 1 1/2 1 1/2 5 2 1 1/2 8 2 2 6 6.7. CLEANOUTS A cleanout is an accessible opening in a drainage system used for removal of obstructions. They are an essential part of the drainage system. The Standard Plumbing Code regulates the cleanouts location at: 1) Less than 100 ft apart in horizontal drains within buildings and building sewers. 2) Each change of direction of the building drain or horizontal waste or soil lines greater than 45º. 3) the base of each waste or soil stack. 4) The junction of the building drain and the building sewer. Cleanout openings can not be utilized for the installation of new fixtures or floor drains and shall be installed to open to allow cleaning in the direction of the flow of the drainage pipe or at right angles thereto.

6.8 REVIEW QUESTIONS 6.1. What are the isometric drawings for? 6.2. What is the stack in a drainage system? 6.3. What is the principal function of a vent stack? 6.4. How many gallons of water flow per minute are equivalent to a fixture unit? 6.5. The minimum size of a building sewer is. 6.6. For determining the size of vent pipes, it is necessary to consider: a) b) c) d) 6.7. The smallest vent pipe that can serve any plumbing fixture is. 6.8. The maximum distance for a horizontal wet vent is. 6.9. Draw the isometric for a vent and drain system for a stack wet vent installation with one shower, one water closet and one lavatory. 6.10. Draw the isometric for an individually vented unit with one kitchen sink, one water closet, one lavatory and one bathtub. 6.11. Name three problems due to inadequate sizing and arrangement of vent pipes. 6.12. The maximum horizontal distance from the trap to the vent depends on the following factors: 6.13. The closer the trap to the vent on a minimum slope the better a) True b) False 6.14. Draw a common vent for two lavatories. 6.15. Name three restrictions and limitations on the use of P. traps. 6.16. How do the traps protect human health?

6.17. Each fixture trap must have a water seal of not less than inches or more than inches. 6.18. All traps must be installed level in relation to their water seals a) True b) False 6.19. For sinks, lavatories, bathtubs, showers and other fixtures, the vertical drop can't exceed inches. 6.20. Under certain conditions, fixtures can be double trapped a) True b) False 6.21. Trap outlets can be larger than the fixture drain to which it is connected a) True b) False 6.22. It is prohibited by the code to connect more than one lavatory to one trap a) True b) False