Honeywell Cable & Custom Electronics

Similar documents
Security & Control Cables

Genesis. Series Low Voltage Cable. Honeywell Cable Catalog

Fire Alarm Cables. Features: Countdown. New Labeling System on box. Color Coded Boxes. Zone and Room Markings

Home Theater Cables. Your complete solution for high-end audio transmission, stereo, professional audio systems and home theater systems.

PAIRED UNJACKETED. Insulation Nominal Anixter. Paired Conductors Thickness O.D. Number AWG Strand No. IN IN

Fire Alarm/Life Safety Cable 6

Genesis Series Cable THE POWER OF CHOICE. Cables for Silent Knight

Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE

SOUND/SECURITY FIRE ALARM/LIFE SAFETY TEMPERATURE CONTROLS COAXIAL DATACOM HARDWARE FIBER OPTIC SPECIAL APPLICATION CATALOG, VOL.

Company Profile. We are dedicated to providing our customers competitive price and excellent service.

Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE

Honeywell Cable. We ve got a cable for that!

Alarm & Security SOLUTIONS. Access Control Video Surveillance Fire Alarm Life Safety

Quick Reference Applications Guide

SHIELD TYPE MULTICONDUCTOR MULTIPAIR

NewGeneration Cables. BELDENCable TM

Comtran s VITALink 2 Hour Fire Resistive CIC & CI Free Air Cables. Your trusted solution for fire safety

Belden Infinity C-TC+ Cables for Extreme Flexing

WIRE & CABLE. Wire & Cable... Wire Accessories...

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

WIRE & CABLE. Wire & Cable... Wire Accessories...

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

Thermocouple Cable TRANSMITTING, SENSING, MEASURING

Providing the accessories you need from quality brands you can rely on.

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

SAS Security and Alarm Safety Cables

electronic wire pocket-picker edition 7/06 Low voltage electronic wire specialists

Category 5 Premise Wire

5. Identification products.

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Installation Guide. Tracer ZN523 Zone Controller BAS-SVN003-E4

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

Texas Based UL Alarm System Monitoring. Alarm System Monitoring Up to 128 zones $34.95 per month 25.00% $26.22

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

commercial-type cabling and connectivity products into the industrial landscape.

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

BELDEN LOW VOLTAGE COPPER CABLE PLENUM RATED

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

EC-BOS-602/616 AX Security

Comtran Cable. Hub-LINK Cables for Transit Applications

Instruction Manual April sitrans AS 100

GE Total Lighting Control

AFC Cable Systems: the Cable Industry Leader for Over 80 Years

CABLES FOR ALARM AND SAFETY SYSTEMS

Multi-Core Fire Resistant Cable

WEBs AX Security. Integrated Security With Simple, Web-Based Management

True Connectivity. True Convenience.

Communicating Controls. Launch Training

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 27 COMMUNICATIONS SECTION PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS

SECTION (13740) - VIDEO SURVEILLANCE

Delivering robust, integrated and future proof security into the UK Health Sector

SECTION INTRUSION DETECTION A. SCOPE OF WORK FOR DESIGNER AND CONSULTANTS

Brand Portable Power Cord & Control Cable Solutions

Installation and Operation. Tracer ZN521 Zone Controller CNT-SVX07C-EN

2-inch Network Speed Dome Installation Manual

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

BT Cables Technical Seminar. CIBSE CPD Programme

SI 3C LP. 4" Low Profile Back Can. Speakers. n 3" (7.6 cm) full-range driver with a tuned port

FF 120T FF 220T EXTRON EXCLUSIVE PATENT PENDING FLAT FIELD SPEAKER WITH TRANSFORMER SPEAKERS. See How it Works WHITE PAPER

Schneider Electric Erie T155 Series

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

. SECTION CONTROL-VOLTAGE ELECTRICAL POWER CABLES

SPEC SHEET. Simple Expansion Solutions ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

Network Speed Dome Installation Manual

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

Category 5e Products

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

SONANCE GARDEN SERIES SGS SYSTEM INSTRUCTION MANUAL

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES

CATEGORY 6A FTP RJ45 SOLUTION

Application Manual LT-6617 Rev. 1 July 2017

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

INTREPID Buried Cable Perimeter Intrusion Detection System

Optional Parts (sold separately): E-4WNSC-x 4-Wire Non-Sensing cable (available in lengths 10/25/50/100 feet and custom lengths up to 1000 feet)

INTRINSICALLY SAFE S314X AND S315X

Your Partner for Custom Interconnectivity Solutions. ISO 9001:2008 AS9100C:2009 ISO 13485:2003 ISO 17025:2005 Qualified

Datasheet PDCSY-MW-MD. Technical Overview. Features. Product warranty and total quality commitment. Heat Meter Integrator

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

SI 3CT LP. Speakers. n 3" (7.6 cm) full-range driver with a tuned port

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

CONGRATULATIONS! TABLE OF CONTENTS. Introduction. Features and Benefits. Parts Guide 4. Installation Considerations 4. Installing the Loudspeaker 6

Flexible Power Cable DLO

InverterFlex SerIeS InverterFlex Systems condition up to five rooms

Model Smart Digital Humidistat

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

2-inch HDCVI Speed Dome Installation Manual

Cat 6 Unshielded Patch cords

Transcription:

Honeywell Cable & Custom Electronics Genesis Series HVAC/Control Cable

ZONE Residential Creating Comfort... Appearance is everything, however, when it comes to HVAC itʼs what you donʼt see that allows you to stand out to potential customers. When a homeowner seeks a dependable HVAC system, the link between system components is probably not on their minds. It is up to you to find a manufacturer that has the most enhanced and efficient cabling available. By helping to prevent wasted energy resources, you actually allow homeowners to control costs when it comes to heating and cooling their homes. The flawless connection of Honeywellʼs thermostat cables throughout the home creates the reliable comfort that homeowners value. Your success depends on an installation that is seamless and reliable. Energy Efficient Zone Control R C Y W 72º Temperature Control Intrusion Detection

Commercial Improving Control Your customers trust you to protect their most valuable asset their business. Installing an Access Control and Building Automation System provides them with peace of mind. But, using control cabling from just any manufacturer could adversely affect the entire system. As these energy and security systems become more intelligent, quality cable becomes an even more important factor. Our control cables are manufactured to the highest quality standards and are recommended to ensure optimal system performance. Honeywell cable is produced with innovative equipment and technology from our state-of-the-art facility. As one of the leading manufacturers in low voltage cabling, we stand behind our promise to provide products that will exceed your expectations. HVAC Control Digital Video Security & Access Control Building Automation Control

Thermostat Cables Applications: Features: Wiring of thermostat controls, heating and air conditioning equipment, doorbells, as well as other low voltage applications. Sunlight resistant except CL2P. Sequential footage markings on spools. Braided ripcord. THERMOSTAT CABLE 60 C - CL2 Code Restrictions: OK for use with all power-limited circuits except those in risers and plenums. Construction: Copper conductors, polypropylene insulation, polyvinyl-chloride jacket. AWG #/COND. PACKAGING SOL NOM. O.D. NOM. CAP. PF/FT LISTINGS AVG. WT. PER MFT PART# 20 2 4 x 500 S or 1 x 500 SB SOL.118 17 CL2 11 4701 20 3 4 x 500 S or 1 x 500 SB SOL.124 17 CL2 14 4702 20 4 4 x 250 S or 1 x 250 SB SOL.136 17 CL2 18 4703 20 5 4 x 250 S or 1 x 250 SB SOL.148 17 CL2 20 4704 20 6 4 x 250 S or 1 x 250 SB SOL.161 17 CL2 24 4705 20 7 4 x 250 S or 1 x 250 SB SOL.161 17 CL2 27 4706 20 8 4 x 250 S or 1 x 250 SB SOL.174 17 CL2 31 4707 20 9 4 x 250 S or 1 x 250 SB SOL.188 17 CL2 35 4708 20 10 4 x 250 S or 1 x 250 SB SOL.204 17 CL2 39 4709 18 2 4 x 500 S or 1 x 500 SB SOL.136 19 CL2 16 4710 18 3 4 x 500 S or 1 x 500 SB SOL.144 19 CL2 21 4711 18 4 4 x 250 S or 1 x 250 SB SOL.157 19 CL2 26 4712 18 5 4 x 250 S or 1 x 250 SB SOL.172 19 CL2 32 4713 18 6 4 x 250 S or 1 x 250 SB SOL.188 19 CL2 38 4714 18 7 4 x 250 S or 1 x 250 SB SOL.188 19 CL2 44 4715 18 8 4 x 250 S or 1 x 250 SB SOL.204 19 CL2 50 4716 18 9 4 x 250 S or 1 x 250 SB SOL.220 19 CL2 55 4717 18 10 4 x 250 S or 1 x 250 SB SOL.240 19 CL2 61 4718 18 12 1 x 250 S or 1 x 250 SB SOL.248 19 CL2 74 4719 Consult factory for availability. S=Spools SB=Speedbags MFT=1000 Feet THERMOSTAT CABLE PLENUM RATED CL2P Code Restrictions: OK for use with all Power-Limited Circuits. Construction: Copper Conductors, Low Smoke PVC, Low Smoke PVC Jacket. AWG #/COND. PACKAGING SOL NOM. O.D. NOM. CAP. PF/FT LISTINGS AVG. WT. PER MFT PART# 18 2 4 x 500 S SOL.136 28 CMP, CL2P, C(UL) FT6 17 4760 18 3 4 x 500 S SOL.144 28 CMP, CL2P, C(UL) FT6 23 4761 18 4 4 x 250 S SOL.157 28 CMP, CL2P, C(UL) FT6 29 4762 18 5 4 x 250 S SOL.172 28 CMP, CL2P, C(UL) FT6 35 4763 18 6 4 x 250 S SOL.188 28 CMP, CL2P, C(UL) FT6 42 4764 18 7 4 x 250 S SOL.188 28 CMP, CL2P, C(UL) FT6 47 4765 18 8 4 x 250 S SOL.204 28 CMP, CL2P, C(UL) FT6 54 4766 18 9 4 x 250 S SOL.220 28 CMP, CL2P, C(UL) FT6 60 4767 18 10 4 x 250 S SOL.240 28 CMP, CL2P, C(UL) FT6 67 4768 18 12 1 x 250 S SOL.248 28 CMP, CL2P, C(UL) FT6 79 4769 Consult factory for availability. S=Spools MFT=1000 Feet For Spec Sheets go to http://www.genesiscable.com/litcenter.asp

Mini Split Cables PRODUCTS FOR MINI SPLIT APPLICATIONS AWG DESCRIPTION JACKET COLOR LISTING PART # 18 2 Conductor Stranded Bare Copper, Overall Shielded Gray CM, CL2 1214 18 4 Conductor Stranded Bare Copper, Overall Shielded Gray CM, CL2 1215 18 4 Conductor Stranded Bare Copper, Unshielded Gray CM, CL2 1119 16 2 Conductor Stranded Bare Copper, Overall Shielded Gray CM, CL2 1221 14 4 Conductor Stranded Bare Copper, Unshielded Black 600v TC 1070 Consult factory for packaging options. Building Automation/Commercial Controls PRODUCTS FOR USE WITH NETWORK AND AUTOMATION CONTROL SYSTEMS AWG DESCRIPTION JACKET COLOR LISTING PART # Cable Approved For Echelon Lonworks (Echelon and Lonworks are trademarks of Echelon Corporation registered in the United States and Other Countries.) 22 1 Pair Stranded Bare Copper, Unshielded Gray^ CM, CL2 1061 22 2 Pair Stranded Bare Copper, Unshielded Gray^ CM, CL2 1062 22 1 Pair Stranded Bare Copper, Shielded Gray^ CM, CL2 1063 22 2 Pair Stranded Bare Copper, Shielded Gray^ CM, CL2 1064 22 1 Pair Stranded Bare Copper Unshielded * CMP, CL2P, C(UL) FT6 3252 22 2 Pair Stranded Bare Copper, Unshielded * CMP, CL2P, C(UL) FT6 3253 22 1 Pair Stranded Bare Copper, Shielded * CMP, CL2P, C(UL) FT6 3254 22 2 Pair Stranded Bare Copper, Shielded * CMP, CL2P, C(UL) FT6 3255 Cable for use with BACnet systems (Conforms to ANSI/TIA/EIA-485 Specifications) (BACnet is a registered trademark of ASHRAE) 18 1 Pair Stranded Bare Copper, Shielded * CMP, CL2P, C(UL) FT6 3322 22 1 Pair Stranded Tinned Copper, Shielded * CMP, CL2P, C(UL) FT6 3251 Nom. Cap = 25 pf/ft, Nom. Impedance = 60 ohms 18 1 Pair Stranded Tinned Copper, Shielded, Mid-Cap * CMP, CL2P, C(UL) FT6 4652 Nom. Cap = 56 pf/ft, Nom. Impedance = 36 ohms 20 2 Conductor Stranded Bare Copper, Shielded * CMP, CL2P, C(UL) FT6 3205 20 3 Conductor Stranded Bare Copper, Shielded * CMP, CL2P, C(UL) FT6 3211 20 5 Conductor Stranded Bare Copper, Shielded * CMP, CL2P, C(UL) FT6 3242 *Consult factory for availability of packaging and color options. ^Consult factory for packaging options. Consult factory for availability. Minimum order quantity may apply. Honeywell Cable Part Number XXXXXXXX For Ordering Information contact Ph: 800-222-0060 Fax: 262-947-0397 Part Put-up Color Number Code Code

Profusion Control Cables ACCESS CONTROL CABLE DESCRIPTION Applications: Building automation, Tridium with Niagara AX Framework & Access/Security Control Systems. Code Restrictions: OK for use with all power-limited circuits. Features: Profusion Access Control Cables are held together by a revolutionary tight, continuous twist scheme that secures lock power, card reader, door contact and Request-to-Exit (Rex/Spare) cables together without an adhesive material, delivering a better bundled cable, while saving the installer valuable time by eliminating the need to remove an outer jacket. PART# 4 Leg Access Control Cable CM Rated 1298 4 Leg Access Control Cable CMP Rated 3295 Construction: DOOR CARD DOOR LEG STRIKE READER CONTACT REQUEST-TO-EXIT Conductor 18 AWG BC 22 AWG BC 22 AWG BC 22 AWG BC 16/30 STR 7/30 STR 7/30 STR 7/30 STR Construction 4/C OAS 3 pair OAS 2/C OAS 4/C OAS Insulation BLK, RED, BLK/RED, BLK, RED BLK, RED, Colors WHT, GRN GRN/WHT, WHT, GRN ORG/BLU Lay Length 3" nom. Pair-2" nom. 1.75" nom. 2" nom. Cable-4.5" nom. Shield AL/Mylar AL/Mylar AL/Mylar AL/Mylar Jacket Color Orange White Blue Green Jacketed Cables Shielded (Overall Shield) Applications: Features: Code Restrictions: Construction: Wiring control, burglar alarm, public address systems, intercoms, telephone stations, speakers, instrumentation and other low voltage circuits that are power-limited. Sunlight resistant. Sequential footage markings, ripcord. OK for use with all power-limited circuits except those in risers and plenums. Twisted copper conductors, polypropylene insulation, aluminum/mylar shield, with drain wire, flexible polyvinyl-chloride jackets. AWG #/COND STR/SOL NOM. O.D NOM. CAP. PF/FT LISTINGS AVG. WT. PER MFT PART# 18 2 STR 0.154 43 CM, CL2 20 (LBS) 1214 18 3 STR 0.161 43 CM, CL2 25 (LBS) 1228 18 4 STR 0.178 43 CM, CL2 32 (LBS) 1215 18 6 STR 0.21 43 CM, CL2 45 (LBS) 1216 18 8 STR 0.23 43 CM, CL2 56 (LBS) 1217 18 10 STR 0.27 43 CM, CL2 69 (LBS) 1218 Consult factory for packaging and color options. MFT=1000 Feet For Spec Sheets go to http://www.genesiscable.com/litcenter.asp

Jacketed Cables, Plenum Rated Applications: Wiring control, burglar alarm, public address systems, intercoms, telephone stations, speakers, instrumentation and other low voltage circuits that are power-limited. Code Restrictions: OK for use with all power-limited circuits. Features: Sequential footage markings, ripcord. Construction: Twisted copper conductors, low smoke PVC insulation, aluminum/mylar shield, with drain wire applied over assembled conductors, low smoke PVC jacket. JACKETED CABLES PLENUM RATED 60º C AWG #/COND STR/SOL NOM. O.D NOM. CAP. PF/FT LISTINGS AVG. WT. PER MFT PART# 18 2 STR 0.150 28 C(UL) FT6, CMP, CL2P 17 (LBS) 3114 18 3 STR 0.16 28 C(UL) FT6, CMP, CL2P 23 (LBS) 3126 18 4 STR 0.18 28 C(UL) FT6, CMP, CL2P 31 (LBS) 3115 18 6 STR 0.21 28 C(UL) FT6, CMP, CL2P 43 (LBS) 3116 18 8 STR 0.232 28 C(UL) FT6, CMP, CL2P 55 (LBS) 3117 18 10 STR 0.274 28 C(UL) FT6, CMP, CL2P 68 (LBS) 3118 Consult factory for packaging and color options. MFT=1000 Feet JACKETED CABLES SHIELDED, (OVERALL SHIELD) PLENUM RATED 60 C AWG #/COND STR/SOL NOM. O.D NOM. CAP. PF/FT LISTINGS AVG. WT. PER MFT PART# 18 2 STR 0.154 62 C(UL) FT6, CMP, CL2P 20 (LBS) 3214 18 3 STR 0.164 62 C(UL) FT6, CMP, CL2P 27 (LBS) 3226 18 4 STR 0.182 62 C(UL) FT6, CMP, CL2P 33 (LBS) 3215 18 5 STR 0.197 62 C(UL) FT6, CMP, CL2P 38 (LBS) 3276 18 6 STR 0.216 62 C(UL) FT6, CMP, CL2P 50 (LBS) 3216 18 8 STR 0.236 62 C(UL) FT6, CMP, CL2P 61 (LBS) 3217 18 10 STR 0.278 62 C(UL) FT6, CMP, CL2P 72 (LBS) 3218 Consult factory for packaging and color options. MFT=1000 Feet OUR QUALITY COMMITMENT If any Honeywell thermostat wire fails to perform to our specification during the life of any original installation, we will replace the cable, three for one. No one else in the industry makes that guarantee. Honeywell thermostat wire is recommended for use with all Honeywell thermostats. Honeywell Cable Part Number XXXXXXXX For Ordering Information contact Ph: 800-222-0060 Fax: 262-947-0397 Part Put-up Color Number Code Code

Honeywell s Genesis Series low voltage wire and cable is produced with innovative equipment and technology. Our leading edge production facility, located in Pleasant Prairie, Wisconsin enables Honeywell to produce the highest quality and cost effective thermostat, electronic, security, fire, sound, voice, data and video wire and cable. See our full line catalog or visit www.honeywellcable.com to see our full product listing of low voltage wire and cable. Thermostat Electronic Shielded and Unshielded Fire Security Sound Video Voice & Data And Much More! For more information: www.honeywellcable.com Honeywell Cable & CE Honeywell 7701 95th Street Pleasant Prairie, WI 53158 800-222-0060 www.honeywell.com L/HVACB/D November 2009 2009 Honeywell International Inc.