Model 4001 Series Single Channel Controller

Similar documents
Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

GAS MONITOR Model Model

RAM3 Remote Alarm Module

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Beacon 800 Gas Monitor Operator s Manual

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

Instruction Manual Model L2 RF Switch

STATUS ALARM HISTORY ALARM RESET

Beacon 410A Gas Monitor Operator s Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

SEC 2000 Millenium Infrared Gas Detector

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

Beacon 110 Gas Monitor Operator s Manual

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

1022 R/T Remote Monitor

RK Transmitter Technical Notice

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

RK Carbon Monoxide Transmitter Operator s Manual

! "! # Please read these installation and operating instructions completely and carefully before starting.

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Controllers. Instruction Manual WARNING

Instruction Manual WARNING

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Model OEM-2 INSTRUCTIONS FOR USE

Commercial and Light Industrial Fire Alarm Control Panel

Pioneer-R16 Gas Monitor Operator s Manual

Model TL104 MANTL104. Test Lamp for Flame Detection

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

RK Carbon Monoxide Transmitter Operator s Manual

Interscan Corporation. Instruction Manual Series Compact Portable Analyzer

ENMET 680 Fairfield Court Ann Arbor, MI Fax LC-8 Controller Operation and Maintenance Manual

0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

RK Combustible Gas Transmitter Operator s Manual

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Instruction Manual Model A

GasSens. Hydrogen Peroxide Monitor. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Combustible Gas Sample-Draw Detector Operator s Manual

SINGLE CHANNEL SYSTEM TWO CHANNEL SYSTEM

Panel Mounted Heat Exchangers by Dantherm, Inc.

RK-05 Carbon Monoxide Transmitter Operator s Manual

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Carbon Dioxide Sample-Draw Detector Operator s Manual

TECHNICAL DATA OBSOLETE

1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors

Warranty Registration

CA5000 Liquid CO 2 Freezer Backup System

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

Sierra Series 900 Single & Dual Channel System. Instruction Manual

Two-Channel Gas Controller

Bench Top Ionizer Installation, Operation and Maintenance

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

/ How To Order

RK Hydrogen Sulfide Transmitter Operator s Manual

CO2 Sensor User and Installation Guide

RK-05 Combustible Gas Transmitter Operator s Manual

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

Safe T Net 210. Instruction Manual Part Number Mar2010

AL600ULADA. NAC Power Extender. Installation Guide

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

RK-02 Multi Point Detector Operator s Manual

Operation Manual. Rev. E GEM-II Self Contained Gas Detector.

QAS-101 SERIES SINGLE CHANNEL CONTROLLERS

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

RK-05 Carbon Monoxide Detector Operator s Manual

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

Installation Guide for models:

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

ESP TECHNOLOGIES LIMITED

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Document No

RAM 50 Series Operation Manual

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

Combustible Gas and Hydrogen Sulfide Beacon 200 Rig Monitor Operator s Manual

Macurco HD-11 Hydrogen Gas Detector

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Electric Duct Heaters

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

Installation Guide for models:

FW-RA-LED Remote Multiplex Annunciator Panels

RK-04 M2 Transmitter Operator s Manual

Transcription:

Model 4001 Series Single Channel Controller Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 (408) 262-9042 - Fax E-Mail: sales@sierramonitor.com Web site: www.sierramonitor.com

Model 4001 Series Single Channel Controller APPLICABILITY & EFFECTIVITY This manual provides instructions for the following Sierra Monitor products: Model 4001-01 Description Controller 4-20 ma Input, DC NEMA 4X 4001-11 Controller 4-20 ma Input, AC NEMA 4X 4001-12 Controller 4-20 ma Input, AC NEMA 7 The instructions are effective for the above models as of December 1, 1998 Instruction Manual Part Number T14002 Rev. B1

TABLE OF CONTENTS 1. PRODUCT DESCRIPTION 1 1.1 INTRODUCTION 1 1.2 DESCRIPTION 1 2. INSTALLATION 2 2.1 CONTROLLER INSTALLATION 2 2.2 ALARM AND RELAY CONFIGURATION 4 2.3 ELECTRICAL WIRING 4 2.4 ALARM ADJUSTMENT 5 2.5 ALARM TEST 6 3. CALIBRATION 7 4. SPECIFICATIONS 8 5. LIMITED WARRANTY 8

1. PRODUCT DESCRIPTION 1.1 INTRODUCTION The Model 4001 Single Loop Controller is an 18 to 24 volt DC operated, single channel, 4-20 ma controller with liquid crystal display. The controller is designed for use with most two or three wire 4-20 ma transmitters, is easily configured for various set-point and alarm functions and is available in alternative power supply and packaging configurations. This manual provides a description of the controller standard features, settings and packaging and the options which are available. The manual also provides instructions for installation and set-up and adjustment of the controller. 1.2 DESCRIPTION Packaging: The Model standard 4001 is supplied in a NEMA/4X, fiberglass enclosure with a viewing window in a hinged door with snap closing latches suitable for padlocking. A NEMA-7 explosion-proof enclosure is also available. Standard Features: Three (SPDT) relays provide dry contact closure for two alarm set-points and for trouble alarm conditions. The set-points are user adjustable and the relays are individually programmable for latching or non-latching operation and for rising or falling trip point. The controller has provision for an alarm acknowledge input. Connections to the controller electronics are made via two modular terminal contact blocks which allow disassembly without removal of individual wires. These terminals include connections for a three wire sensor module, reset switch input, chart recorder power, chart recorder signal, relay contacts, system power, battery and optional local alarm buzzer. - Set Point 2 Alarm High/Alarm Low (Factory setting: Alarm High) - Set Point 2 Acknowledge (Always available via reset input). - 5 Volt Buzzer Output on First Alarm (rising) - 5 Volt Buzzer Output on First Alarm (falling) Hardware Options: Optional configurations include the following: - Power Supply 110 VAC / 24 DC: The open frame power supply is a 120 VAC to 24 VDC linear supply. The load capacity is 1.2 amps and the AC input is fused. - Battery for battery back-up: A twelve volt 6.5 ampere hour sealed battery is trickle charged by the control electronics and provides the specified backup operation. - Nema 7X enclosure Part Numbering: Ordering part numbers for the loop controller are as follows: Model Number Description 4001-01 Controller 4-20 ma Input, DC NEMA 4X 4001-11 Controller 4-20 ma Input, AC NEMA 4X 4001-12 Controller 4-20 ma Input, AC NEMA 7 Programmable Functions: Electrical jumpers are used to select the following functions: - Set Point 1 Latch/Non Latch (Factory setting: Non Latch) - Set Point 1 Alarm High/Alarm Low (Factory setting: Alarm High) - Set Point 1 Acknowledge (Always available via reset input). - Set Point 2 Latch/Non Latch (Factory setting: Non Latch) 1

2. INSTALLATION 2.1 CONTROLLER INSTALLATION 1.1 Select a location based on the following considerations: - Provide normal security from unauthorized access. - Reliable AC power supply. - Mount the controller at a height which allows easy visual inspection of the digital display. - The enclosure must be accessible for normal calibration and maintenance. - Avoid exposure of the window to direct sunlight. 1.2 Mount the controller enclosure using mounting flanges provided on each configuration. 1.3 Pull all required wiring for power supply, alarm devices etc. through electrical 3/4" conduit hubs located on the bottom of the enclosure following appropriate installation code. 1.4 Make any jumper configuration changes following the instructions titled Alarm and Relay Configuration. (Table 1) 1.5 Terminate all wiring following the instructions titled Electrical Wiring. Figure 1 Model 4001 Loop Controller 2

W3 W10 Alarm 1 Latch W3 W10 Alarm 1 Non Latch (factory) W4 W11 Alarm 1 Alarm High (factory) W4 W11 Alarm 1 Alarm Low W5 W12 Alarm 1 Acknowledge (always) W5 W12 Not Used W6 W13 Alarm 2 Non Latch (factory) W6 W13 Alarm 2 Latch W7 W14 Alarm 2 Alarm Hight (factory) W7 W14 Alarm 2 Alarm Low W8 W15 Alarm 2 Acknowledge (always) W8 W15 Not Used W9 W16 Buzzer Alarm on High (factory) W9 W18 Buzzer Alarm on Low Table 1 Model 4001: Alarm Function Jumpers 3

2.2 ALARM AND RELAY CONFIGURATION Figure 2 indicates the location of the jumpers W3 through W16. Table 1 shows the location of the jumpers for each alarm function with the factory settings identified. To change the settings turn off all power sources, remove the four screws in the corners of the display panel and lift out of the way to gain access to the jumpers. Lift the jumpers using needle nose pliers and replace them as required. 2.3 ELECTRICAL WIRING All electrical wiring except the AC supply terminates at the two 12 position terminal strips which are located accross the bottom section of the electronics card (figure 2). The connector closest to the end of the card is identified as TB2 and the other connector is TB1. These terminal strips are also pin connectors so that the entire strip can be removed by pulling the body from the pins for termination or service. See Table 2 for identification of each of the terminals. The AC supply (where applicable) which should be into the connected to the appropriate terminals labeled H N G beside the open frame power supply. CCW CW CCW CW Figure 2 Model 4001: Component Locator 4

2.4 ALARM ADJUSTMENT As the controller has no on/off switch the AC fuse should be removed until installation is complete. The system operation can be tested without connection of the battery but when continuous operation is initiated connect the battery to the appropriate terminal blocks (Table 2). To change alarm levels move the digital display panel down to access the top of the controller electronics card including the selector switch and potentiometers. Figure 2 shows the location of the Alarm 1 and Alarm 2 adjustment potentiometers and display selector switch. TB 1 12 11 10 9 8 7 6 5 4 3 2 1 1 Alarm 1 N/C 7 Trouble N/O 2 Alarm 1 C 8 Trouble C 3 Alarm 1 N/O 9 Trouble N/C 4 Alarm 2 N/C 10 Sensor Ground 5 Alarm 2 C 11 Sensor Signal * 6 Alarm 2 N/O 12 Sensor Power TB 2 12 11 10 9 8 7 6 5 4 3 2 1 1 Battery + 7 Recorder + Signal 2 Battery - 8 Recorder - Signal 3 VDC In + 9 Buzzer - 4 Common 10 Buzzer + 5 Recorder + VDC 11 Reset + 6 Recorder - VDC 12 Reset - NOTES TO TABLE 2: Table 2 Model 4001 Controller Electrical Connections * 4-20mA - For 5100-IT-XX Model Alarms 1 & 2: SPDT Dry contact Relays 10 Amp (fused to 4 amps). Trouble: SPDT Dry contact Relay 10 Amp (fused to 4 amps). Sensor: Power is the input voltage. Current Loop is between Signal and Ground Battery: Connect 12 VDC, 4-8 AH sealed rechargeable Lead Acid battery for uninterrupted operation during loss of AC supply. VDC In: On AC Controllers this connection is factory installed. On DC controllers connect 18-24 VDC (1 amp) supply. Recorder +VDC: This is a 12 volt (50 ma) output to provide power to operate a chart recorder. Recorder Signal: This is a 0-2 VDC signal proportional to the current input (min. R L = 2K). Buzzer: +5V with open collector output (for external buzzer) Reset: Connect a momentary switch to provide for alarm acknowledge or for reset of latched relays. 5

To change the concentration at which Alarm 1 will activate: - Slide the three position selector switch full right to the third position. The display will indicate the factory set Alarm 1 level of 10 ppm. - Adjust Alarm 1 potentiometer until the display reads the required new Alarm 1 set point. To change the concentration at which Alarm 2 will activate: - Move the three position selector switch to the second (center) position and follow the same procedure as above (factory setting is 20 ppm). When alarm adjustments are complete return the selector switch to the first (full left) position for display of the actual concentration. 2.5 ALARM TEST To test the alarm relay functions press the relay test switch marked SW2 on the control board (figure 2). The relay test switch which will cause both alarms to activate simultaneously. Correctly functioning alarms will cause both the relay to activate and the respective LED on the control board to turn on. (Note that there is a deliberate hysteresis built into the alarm function to avoid oscillation when the gas concentration remains close to the set point. This hysteresis will cause the alarm to activate at the set point and to turn off at a slightly lower level than the set point). 6

3. CALIBRATION Calibration of input devices should be accomplished using the procedures for the individual devices. The controller should not require periodic calibration. If adjustments are necessary (see figures 2 and 3): 1. With 4 ma loop current adjust Zero Display Adj. for 0.00V ( + 0.01) at TP12. 2. With 20 ma loop current adjust Gain Adj. for 2.00V ( + 0.01) at TP12. 3. With 20 ma loop current adjust Full Scale Display Adj. for desired full scale reading. Figure 3 Model 4001 Electrical Test Points 7

4. SPECIFICATIONS INPUT POWER: 18-24 VDC, Nominal 350mA, Max 500mA ENCLOSURE: NEMA/4X (11.5" x 8.0" x 7.0") (29.2 x 20.3 x 17.8 cm) DISPLAY: 3 1/2 Digit Liquid Crystal ALARM LEVELS: Low and High Alarms User Adjustable ALARM RELAYS: Low and High Alarms selectable Latching/Non latching, Alarm Acknowledge Trouble (includes loop failure) Contact rating 28 VDC @ 4A (fused) 120 VAC @ 4A RECORDER OUTPUT: 0-2 VDC Output proportional to display CHARGER OUTPUT: 12 VDC Trickle Charge for battery back-up OPTIONS POWER SUPPLY 110 VAC (200 ma) BATTERY BACK-UP 4 AH 12 VDC gell cell ENCLOSURE NEMA 7 (12" X 11" X 9") (30.4 x 27.9 x 22.8 cm) 5. LIMITED WARRANTY SIERRA MONITOR CORPORATION warrants its products to be free from defects in workmanship or material under normal use and service for two years after date of shipment. SMC will repair or replace without charge any equipment found to be defective during the warranty period. Final determination of the nature and responsibility for defective or damaged equipment will be made by SMC personnel. All warranties hereunder are contingent upon proper use in the application for which the product was intended and do not cover products which have been modified or repaired without SMC approval or which have been subjected to accident, improper maintenance, installation or application, or on which original identification marks have been removed or altered. This Limited Warranty also will not apply to interconnecting cables or wires, consumables (ie. calibration gases, batteries, sensors), nor to any damage resulting from battery leakage. In all cases SMC s responsibility and liability under this warranty shall be limited to the cost of the equipment. The purchaser must obtain shipping instructions for the prepaid return of any item under this warranty provision and compliance with such instruction shall be a condition of this warranty. Except for the express warranty stated above, SMC disclaims all warranties with regard to the products sold hereunder including all implied warranties of merchantability and fitness and the express warranties stated herein are in lieu of all obligations or liabilities on the part of SMC for damages including, but not limited to, consequential damages arising out of/or in connection with the use or performance of the product. 8