ECLIPSE INFORMATION GUIDE

Similar documents
ECLIPSE INFORMATION GUIDE

Eclipse AirHeat Burners

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Eclipse AirHeat Burners AH Series version 2.00 (Patent Pending)

Design Guide No /01. RatioMatic Burners. RM Series Version 3.10

Design Guide /12/2008. Eclipse RatioAir Burners RA Series Version 1

Eclipse AirHeat Burner

Eclipse RatioMatic Burners

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

Design Guide 111 9/25/2008. Eclipse Winnox Burners WX Series Version 1

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

PBG PACKAGED GAS BURNER

Indirect gas-fired air heater

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

QHT Manual for: SU-2A Gas Burner

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

Columbia Boiler Company

Eclipse Self-Check UV Scanner

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

Type CG Series Forced Draft Gas Burner

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

INSTALLATION INSTRUCTIONS # BURNER ASSEMBLY REPLACEMENT

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

Design Guide No. 330, 10/02 Immersion Burners

Eclipse 90 UV Scanner Model A Version 1

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

24 VAC SYSTEM CONTROL KIT

Eclipse ImmersoJet Burner

INDITHERM. Low temperature gas burners

STR-Series Indirect-Fired Air Turnover Units

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Installation Instructions

24 VAC SYSTEM CONTROL KIT

USER MANUAL Gas Countertop Charbroilers

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

THC-175DF INDUSTRIAL / COMMERCIAL SPACE HEATER. Certified to / Certifié à CGA 2.14 M2011 Conforms to / Conforme à ANSI std Z83.

PRE-PLANNING GUIDE for the Linear Burner System

HG Million Btu/Hr Gas-Fired Heater

GP COMBUSTION EQUIPMENT INC 100 Sheldon Dr., Units 16/17 Cambridge, Ontario N1R 7S7. Model C Forced Draft Burners. Natural Gas or Propane MODEL C10

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world

V SERIES HDR GAS RANGES

A. Product Data: Include rated capacities, furnished specialties and accessories.

LNB 1000 Series Low Nox Burner

Model Universal Oil Primary Control

USER S INFORMATION MANUAL

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

Fig. 1 - Unit PGD4, PGS4, WPG4

25M01A-100 to 25M01A-199 HSI Single Stage Combination Gas Valve

NMG NOZZLE MIX GAS BURNERS

USER S INFORMATION MANUAL

40 SERIES GAS BURNER MODEL 400 NATURAL GAS/PROPANE INSTALLATION INSTRUCTIONS AND OWNER S HANDBOOK

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

THC- 355DF (Dual Fuel)

SUBMITTAL SCHEDULE & DATA

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER

NOZZLE MIX COMBINATION BURNER NMC200 SERIES

LGB Gas fired boiler

120 VAC SYSTEM CONTROL KIT

INSTALLATION AND MANINTENANCE INSTRUCTIONS

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Forced draught natural gas/propane burner

BGH Series Hot Surface Ignition Control

Owner s Information Manual

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

Owner s Guide Installation & Operation

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

INDUSTRIAL MICRODIFFUSION OIL BURNERS

G34M Bulletin #69/ August 2003

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

Owner s Guide Installation & Operation

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

INSTALLATION AND OPERATION INSTRUCTIONS

USER S INFORMATION MANUAL

INSTALLATION & OPERATION MANUAL FOR Achiever Charbroilers

Single stage operation forced draught natural gas/propane burner

1. GENERAL SAFETY RULES

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

CYLINDER NOT INCLUDED

Cast Iron Commercial Hot Water Or Steam Boiler

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

GAS OVEN SERVICE MANUAL

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

Flame Safeguard Fault Code Diagnostics

Single stage operation oil burner

TECHNICAL SUPPORT: SERVICE BULLETIN #4 (v ) AB2017 HOT SURFACE IGNITION MODULE OVERVIEW

INSTALLATION & OPERATION MANUAL GAS CHARBROILERS

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

S150 S300 CONSTRUCTION HEATERS. Rev: August 15, 2008 SERVICE AND MAINTENANCE MANUAL No PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS

Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

U n i t H e at e r s

Transcription:

ECLIPSE INFORMATION GUIDE JUNIOR INDUSTRIAL BURNERS Models 0 & 6 JIB Info 80 0/9 Easy to install and operate. Rugged construction for long life in industrial environments. Protection against overheating from residual oven heat. Electronic flame monitoring. Two automatic gas shut-off valves. Air flow proving switch. 00% factory tested and adjusted. 6 JIB-G WARNING The burners covered in this Guide are designed to mix fuel with air and burn the resulting mixture. All fuel burning devices are capable of producing explosions and fires when improperly applied, installed, adjusted, controlled, or maintained. This Guide will provide information for using these burners for their limited design purpose. Do not deviate from any instructions or application limits in this Guide without written advice from the Eclipse Combustion Division in Rockford, Illinois. Read this entire Guide before attempting to light burners. If you do not understand any part of the information in this Guide, contact your local Eclipse representative or Eclipse Combustion before proceeding further. Important Notices About Safe Burner Operation l. Store the burner inside. Exposure to the elements can damage the burner.. Adjustment, maintenance, and troubleshooting of the mechanical parts of this unit should be done by people with good mechanical aptitude and experience with combustion equipment.. Order replacement parts from Eclipse Combustion only. Any customer-supplied valves or switches should carry UL, FM, CSA, and/or CGA approval where applicable.. The best safety precaution is an alert and competent operator. Thoroughly instruct new operators so they demonstrate an adequate understanding of the equipment and its operation. Regular retraining must be scheduled to maintain a high degree of proficiency. The operator must have easy access to this Information Guide at all times. ECLIPSE COMBUSTION

.0 Applications JIB burners are complete assemblies ideal for use in ovens, furnaces, kilns, or incinerators requiring simple burner operation and easy maintenance..0 Specifications Specifications Inputs Burner Btu/hr. kw Natural gas or propane vapor 0 JIB-F 70,000 9.8 6 JIB-G,000,000 9.0 Gas Inlet Pressures Burner Minimum Maximum At valve train inlet 0 JIB-F.0" w.c.. mbar.0" w.c..8 mbar 6 JIB-G 8." w.c. 0.7 mbar.0" w.c..8 mbar Electrical Supply 0 VAC, cycle, 60 hz. Motor Type 0 JIB-F: / hp, 0 rpm, open, with built-in overload protection. 6 JIB-G: /6 hp, 600 rpm, TEFC, with built-in overload protection. Firing Chamber Limits Draft required: 0.0" w.c. (0. mbar) to." w.c. (.7 mbar). JIB burners will not operate against any backpressure. Ambient Temperature Limits -0 to +0 F (-0 to +0 C) Materials Burner Body: Cast iron Blower Housing: Cast iron. Impeller: Steel. Flame tube: Cast iron. Net Weight 7. pounds.9 kilograms Models Burner Assembly Flame Monitor Sensor Sensor # 0 JIB-F 09789-00 None None --- 0 JIB-F 09789- Eclipse 60- Flame rod 09-0 JIB-F 09789-0 Honeywell RA-890F Flame rod 09-0 JIB-F 09789-0 PCI 76 BE Flame rod 09-0 JIB-F 09789- Eclipse 60- UV scanner 099 0 JIB-F 09789-0 Honeywell RA-890G UV scanner 68 0 JIB-F 09789-0 PCI 76 BE UV scanner 76 6 JIB-G 0979-00 None None --- 6 JIB-G 0979- Eclipse 60- Flame rod 09-6 JIB-G 0979-0 Honeywell RA-890F Flame rod 09-6 JIB-G 0979-0 PCI 76 BE Flame rod 09-6 JIB-G 0979- Eclipse 60- UV scanner 099 6 JIB-G 0979-0 Honeywell RA-890G UV scanner 68 6 JIB-G 0979-0 PCI 76 BE UV Scanner 76 Burners ordered less relay include an ignition plug, ignition transformer, and ignition cable. The customer must supply a suitable flame monitoring relay, base, and flame sensor meeting local and/or insurance requirements. To mount a UV scanner on the burner, order scanner adaptor #978. Flame rod #09- is furnished -/" long; it must be cut to -/" long to be used in the burner. Flame monitoring equipment supplied with these burners by Eclipse may or may not meet local safety and/ or insurance requirements. The owner/user and/or his insurance underwriter must assume responsibility for the acceptance, use, and proper maintenance of flame supervision, limit controls, and other safety devices.

Figure Dimensions & Parts List 0 JIB-F & 6 JIB-G Burner 7 -/" mm 9 Tap B /8" Pipe Plug on Opposite Side of Inlet Cock Gas Inlet " N.P.T. 0 8 0-/" 67 mm 6-/8" 68 mm Air Shutter Gas Adjusting Screw O.D. -/" mm 6 " 8 mm 7-9/6" 9 mm -/" 70 mm Mounting Flange Detail Mtg. Holes () /" Dia. ( mm) Optional 0 Adaptor 6-/8" Sq. 6 mm -/8" Sq. 0 mm -/6" 8 mm Optional Adaptor #08 0 Item Function Description 0 JIB-F 6 JIB-G Manual Gas Cock Essex 9 9 Automatic Gas Shut-Off Eclipse Solenoid 0 0 Automatic Gas Shut-Off Eclipse Solenoid 0 0 Manual Gas Cock Essex 9 9 Automatic Pilot Valve Eclipse Solenoid 678-678- 6 Adjustable Pilot Cock --- 69 69 7 Air Flow Switch SMDF-C 9 9 8 Ignition Transformer RA-890G or PCI UV / Wave Transformer All other burners 6-6A00E 78 78 9 Flame Monitor See model under Specifications. 0 Flame Sensor Spark Plug --- 696-6 696-6 Blower Motor See Specifications 66 99

L Black On/Off Shown in normal position. If hot gases back up through the burner, the Therm-o-Disc switches to turn the motor on, cooling the burner. Figure JIB Wiring Diagrams 7 S S Eclipse 60 V/ Ph/60 Hz Fused disconnect by customer. L must always be hot, L must be ground. DO NOT REVERSE! Therm-o-Disc Red Air Flow Switch Black Yel. A Black Stripe Orange Purple Brown Eclipse 60 60- For UV Scanner 60- For Flame rod Flame Sensor M Pilot Solenoid Ignition Trans. 6000 VAC To Igniter Main Gas Solenoid # Main Gas Solenoid # To S To S L Green S S 7 Terminal Locations Ground A UV Scanner To S Yellow To S Honeywell RA-890 L V/ Ph/60 Hz Fused disconnect by customer. L must always be hot, L must be ground. DO NOT REVERSE! L Black On/Off Therm-o-Disc Jumper RA-890G Only Orange Purple Black Stripe M Pilot Solenoid Ignition Trans. 6000 VAC To Igniter 6 T T F G Terminal Locations Shown in normal position. If hot gases back up through the burner, the Therm-o-Disc switches to turn the motor on, cooling the burner. Red Air Flow Switch Jumper Yel. 6 T T F G Brown Honeywell RA-890 RA-890F For RA-890G For UV Scanner Flame Sensor Main Gas Solenoid # Main Gas Solenoid # To F To G Green To F To G UV Scanner

Figure JIB Wiring Diagrams (Continued) PCI 76 BE Black L Therm-o-Disc V/ Ph/60 Hz Fused disconnect by customer. L must always be hot, L must be ground. DO NOT REVERSE! Black Stripe M L Terminal Locations 6 7 8 9 E UV G On/Off Red Air Flow Switch Jumper Yellow Orange Purple Pilot Solenoid Ignition Trans. 6000 VAC To Igniter To E To G Green Shown in normal position. If hot gases back up through the burner, the Therm-o-Disc switches to turn the motor on, cooling the burner. 7 E UV G Brown Flame Sensor Main Gas Solenoid # Main Gas Solenoid # UV Scanner Purple To UV Yellow To G PCI 76 BE Figure Burner Mounting Gasket Figure Gas Adjustment Data 000 /8" (0 mm) Studs " ( mm) Long Welded to Oven Shell Fill Gap With Insulation Oven Wall Cutout -/" mm Fill Gap With Insulation Natural Gas Capacity Btu/Hr. in 000 s 900 800 700 600 00 00 00 00 00 6 JIB-G With 8." w.c. Gas Press. at Tap B 0 JIB-F With " w.c. Gas Press. at Tap B 0 0 6 8 0 6 8 0 Gas Adjusting Screw Turns Open See Figure for mounting flange dimensions. Gasket Oven Wall Cutout -/" ( mm) On 0 Deg. Angle For Propane: With the gas inlet pressures listed above, multiply the number of turns of the adjusting screw by 0.0. Alternately, the gas inlet pressure may be multiplied by.0, in which case the graph is correct as shown. See Figure for adjusting screw details.

.0 Installation WARNING If improperly adjusted or operated, burners can produce toxic concentrations of gases, including carbon monoxide. Venting these products into confined, poorly ventilated areas is dangerous. To avoid this situation: Vent the appliance to the outdoors wherever feasible. See the appliance manufacturer's instruction manual for flue and stack design guidelines. Where equipment location or other considerations prevent outside venting, be sure that the building has adequate volume and fresh air makeup to dilute any potentially harmful combustion products down to safe levels as defined by OSHA or other authorities having jurisdiction.. Burner Inspection Make a thorough inspection of the burner when uncrating and before installing it. If any parts appear broken, bent, or damaged, contact your Eclipse representative or the Eclipse factory before installing the burner.. Burner Environment Protect burners from the weather. Combustion air should be free of contaminants which might corrode or plug the blower or burner's internal passages. Provide access to the burners for inspection, maintenance and removal. Any obstruction placed directly in front of the burner will overheat and damage the burner.. Burner Mounting See Figure for mounting details. Do not overtighten the mounting bolts, as excessive force on the flange may break the casting. For maximum service life of the automatic gas shutoff valves, mount the burner in the orientation shown in Figure.. Burner Piping Connect the gas supply line to the burner and make certain the supply line is adequate in size. For long runs, the pipe size should be larger than the burner inlet to prevent excessive losses. Check with your gas company if in doubt. For convenience in burner removal, Eclipse recommends installing a shutoff cock and suitable pipe union dsconnect upstream of the burner. Use flexible nipples on all gas connections. Solid piping may restrain the burner from normal thermal expansion and damage the burner or its piping components. Do not use the burner assembly to support the piping. Gas piping must comply with American National Standard National Fuel Gas Code (NFPA No. or ANSI Z.)*, or must be acceptable to the authority having jurisdiction.. General Wiring Suggestions The electrical supply must be 0 volt, 60 cycle, single phase AC. Make all electrical connections in accordance with the appropriate wiring diagram in Figure. Do not disturb the factory installed wiring. Contact the Eclipse factory regarding special operating sequences and controls. Install suitable main disconnect switch and fuses at a convenient location. Be certain that the ignition cable is properly connected to the spark plug and the pilot ignition transformer. Electrical wiring must comply with the National Electric Code*, (NFPA Std. 70 or ANSI-CI 98), or must be acceptable to the authority having jurisdiction. *Available from: National Fire Protection Association Batterymarch, Park Quincy, MA 069 American National Standard Institute 0 Broadway New York, NY 008 6

.0 Start-Up & Adjustment CAUTION JIB Burners are factory-adjusted on natural gas and tagged with the correct pressure settings. If factory settings have been tampered with, or if the burner will be operated on propane vapor instead of natural gas, field adjustment will be necessary. Follow the procedure below. These general instructions apply regardless of the type of flame monitoring relay installed. See the appropriate data sheets for specific information on the operation and sequencing of the particular relay installed on the burner.. Close the main manual gas cocks and the pilot gas cock and turn the burner On-Off switch Off.. Loosen the lock nut on the gas adjusting screw (Figure ). Using an allen wrench, turn the adjusting screw clockwise until it seats within the burner body. Referring to the graph in Figure, open the screw the number of turns required for the desired burner capacity.. Open the air shutter approximately /" for the 0 JIB-F, and /" for the 6 JIB-G.. Turn the handle of the adjustable pilot cock to the open position, Figure 6.. Turn the burner On-Off switch On to start the blower..6 Once the air flow switch has proven blower operation, the flame monitoring control will be energized. The pilot solenoid valve will open and there will be a second trial for ignition (TFI)..7 After the pilot ignites, adjust the pilot gas cock by removing the top screw, Figure 6. Turn the adjusting screw clockwise to reduce gas flow, and counterclockwise to increase gas flow. When the desired setting is reached, replace the top screw. Pilot gas should be adjusted to the minimum flow which holds the flame monitoring device and positively ignites the burner. If the pilot gas input is too low, nuisance shutdowns will occur; if the input is too rich, aldehydes form. Eclipse Controls flame monitoring relays have a front panel pilot test button that will hold the burner on pilot, giving you as much time as you need to adjust the pilot. See I-60 Information Guide for details on this feature..8 The flame monitor will prove pilot operation and energize both main gas solenoid valves..9 Open the main manual gas cocks. After the main flame is lit, adjust the air shutter if necessary to achieve the desired flame characteristics..0 When the burner is fully adjusted, lock the air shutter and gas adjusting screw in place.. If necessary, re-adjust the pilot setting to compensate for changes in the air shutter opening.. The burner can now be operated without further adjustment, using only the on-off switch. Figure Main Gas Adjusting Screw Figure 6 Pilot Cock Handle Shown in Open Position Top Screw Locknut Loosen before adjustments; tighten afterwards. Adjusting Screw Clockwise (in) for less gas; counterclockwise (out) for more gas. Adjusting Screw Clockwise for less pilot gas; Counter-Clockwise for more pilot gas. See Figure for adjusting screw location. 7

.0 Trouble-Shooting CAUTION Trouble shooting of electrical circuits should be done by qualified plant electricians, technicians, or engineers experienced in all facets of this type of combustion equipment. PROBLEM Pilot fails to light. POSSIBLE CAUSE. On initial start-up, gas line may be filled with air. Repeat ignition trial several times to purge.. No power to ignition transformer or pilot solenoid.. Open circuit between ignition transformer and spark plug.. Spark plug is dirty or improperly installed.. Pilot gas cock screw closed. 6. Insufficient gas pressure at valve train inlet. Main flame fails to light.. Pilot set too lean, blows out as main flame comes on.. Insufficient gas pressure at valve train inlet.. Gas flow misadjusted. See Section.0. Burner behaves erratically, does not respond to adjustment.. Burner internals loose, dirty or burned out. If any of these problems exist, contact your Eclipse representative or the Eclipse factory for service. Main flame is too long and yellow on high fire.. Gas flow is misadjusted. See Section.0.. Air shutter is closed too far. Main flame is too short at high fire.. Gas flow is misadjusted. See Section.0.. Air shutter is open too far. 6.0 Maintenance 6. Motor Lubrication Oil the blower motor according to the manufacturer s instructions as printed on the motor label. 6. UV Scanner Maintenance Periodically clean the UV scanner lens as described in the manufacturer s product literature. 6. Ignition Plug and Replacement Ignition plugs and flame rods wear out over long periods of normal burner operation. Eclipse recommends that the user keep at least one of each in stock at all times to prevent nuisance shutdowns. See Figure 7 for proper ignition plug installation. Figure 7 Ignition Plug Installation Gas Tube Spark Gap /6" to /8" mm to mm Ignition Plug Insert metal washer(s) here if necessary to obtain proper gap. ECLIPSE COMBUSTION Litho In U.S.A.