Warmette Blanket Cabinet Warmette Dual Cabinet. User Manual

Similar documents
USER MANUAL AND TECHNICAL MANUAL

User s Manual Warm N Cozy

Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

SpotOn Temperature Monitoring System. SpotOn. Temperature Monitoring System. Model 370 Installation and Service Manual

TTT Digital Incubator

SPECIFICATIONS Power Requirements: V, 9.5A, 60Hz V, 5.8A, 50Hz Including 2A for internal convenience outlet.

INSTRUCTION & USER MANUAL

INSTRUCTION & USER MANUAL

INSTRUCTION MANUAL. UNDERCOUNTER WINE & BEVERAGE COOLER (32 bottles capacity) MODEL:WC-30U

INSTRUCTION MANUAL COMPRESSOR DRIVEN WINE COOLER

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Outdoor Beverage Center

Since User Manual LBC6178 Beverage Centre LWC646 Wine Storage Built Under. lemairappliances.com.au

Thermoelectric wine cooler. Model No: UBWC450. Operation Manual

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

LABORATORY OVENS MODELS INCLUDE: TO-152G & TOH-152G TO-152F & TO-235F DEHYDRATING OVENS MODELS INCLUDE: TD-150F TD-330F TD-500F

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

BEVERAGE COOLER WITH DUAL TEMPERATURE ZONES INSTRUCTION MANUAL

Undercounter Refrigerator Operation Manual i.series and Horizon Series

Digital Heat Block User Manual

Owner's Manual TABLE OF CONTENTS

Table of Contents DIGITAL DRYING OVEN. Features. Setup. Cautions. Description of the parts. Temperature Controls. Maintenance and Storage

2364 Leicester Road, P.O. Box 175, Leicester, NY Phone (585) Fax (585)

Undercounter Refrigerator Operation Manual

ASSEMBLY AND INSTRUCTION MANUAL (EN)

Motion Sensor Oscillating Heater with Digital Control

Operation Manual. (Version 1.5.1)

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

USER MANUAL. Vino 160 Vino 440. Wine Coolers

BULL INSTRUCTION MANUAL. Model Number: BC-130 REFRIGERATOR BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

CLASSIC PLUS INFRARED ZONE HEATER

USER MANUAL SAVE THESE INSTRUCTIONS

SCIENTIFIC WARMING CABINET Installation, Operation and Maintenance Instructions

Operation Manual (Version 1.5.1)

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

SAVE THESE INSTRUCTIONS

User's Guide. CO 2 Monitor. Model CO200

Refrigerated Incubator Model and Operating Instructions

A few simple steps to ensure perfect water, every time.

GS-1. Instruction Manual. G-Series Cooler. Manual is for the following models: GS-1-N14NF GS-1-N14NG GS-1-N14NI COUNTERTOP COOLER

Use and Care Manual with Installation Instructions

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel

A few simple steps to ensure perfect water, every time.

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

Operation Area...1 Safety Precautions...2 Parts Name...3 Check Before Operation...4. Operation Method...5 Drainage Option...9

INFRARED QUARTZ HEATER

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

Owner's Manual TABLE OF CONTENTS

Oil Panel Heater Instructions for Use

Fluid Warming Cabinet

THERMOELECTRIC COMBO COOLER. Model: DX-68 COMBO. Operation Manual

Portable Room Air Conditioner and Heat Pump

Dual Tank Deep Fryer. Use and Care Instructions. Double Capacity Twice the Power Easy Cleanup

5580 S. Nogales Highway Tucson, AZ Phone: (800) Fax: (520) ANAPOD Instructions For Use

Elite Series Blanket Warming Cabinet

# TFB-S-120, TFB-L-120 TFB-S-220, TFB-L-220 FWS-S-120, FWS-L-120 FWS-S-220, FWS-L-220

USER MANUAL. Pharmacy Refrigerator Range. Applicable models: PSR353/PGR353 PSR273/PGR273 PSR151/PGR151

Soldering Station INSTRUCTION MANUAL

Owner s Manual Window Air Conditioner

Titan Series Blanket Warmer

User s Manual UPRIGHT FREEZER WHS-507FWEW1 / WHS-507FWESS1 WHS-625FWEW1 / WHS-625FWESS1 WHS-772FWEW1 / WHS-772FWESS1

SAVE THESE INSTRUCTIONS

OPERATION & INSTALLATION MANUAL AIR PURIFICATION SYSTEM (APS300)

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

INFRARED ZONE HEATING SYSTEM

Fluid Warming Cabinet

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

BUILT-IN OVEN MODEL: EBO-D7080D(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

HOT WATER BOTTLE BATH PART NUMBER

2175DWRWC Wine Captain Drawer

Blanket Warming Cabinet

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

ANGELUS (Ver 2.03) Patient Monitoring System

Accessible. Durable. Smart.

Owner s Manual TABLE OF CONTENTS

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

UPRIGHT FREEZER WHS-502FWEW1(E) WHS-502FWEB1(E) WHS-502FWESS1(E)

Superior Spa with Aqua-Aire

FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers

MODEL 721 ELECTRICAL DATA: FEATURES: ACCESSORIES: DIMENSIONS: SHIPPING INFORMATION: CONVECTION OVEN 1/2 SIZE PAN

OPERATOR S MODEL HCN-5 HHC-136 HEATED HOLDING CABINET REGISTER WARRANTY ONLINE AT

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

OWNER'S MANUAL. FRY Holding Unit (FHU) MODELS FHU1 FHU2. Duke Manufacturing Company

Wireless Remote Controller Kit

SERVICE & TROUBLESHOOTING MANUAL FOR DISPLAY HOLD CABINETS DHC SERIES

HT-MOSEL-51D PLEASE READ THIS MANUAL CAREFULLY BEFORE USING THE WINE CHILLER

OPERATING MANUAL FOR LF-852DII HOT-AIR S.M.D. REWORK STATION

Isotemp Low Temperature Incubator

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

IMPORTANT INSTRUCTIONS READ & SAVE

SERVICE PROCEDURES. Mattress 2 Pipe Overlay or Replacement

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

INSTRUCTION MANUAL. Model Number: DX K Wine Cooler BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

INFRARED QUARTZ HEATER

4L Instant Water Boiler Instructions for Use

Transcription:

Warmette Blanket Cabinet Warmette Dual Cabinet User Manual

Natus and Warmette are registered trademarks of Natus Medical Incorporated. 2013 Natus Medical Incorporated. All rights reserved. This manual may not be reprinted or copied in whole or in part without written consent from Natus Medical Incorporated. The content of this manual may change without notice. Natus Manufacturing Ltd IDA Business Park, Gort, Co.Galway, Ireland Technical Service +1 800 303 0306 Technical Service Fax +1 650 802 8680 E-mail: technical_service@natus.com Customer Service +1 800 303 0306 Customer Service Fax +1 650 802 6620 E-mail: customer_service@natus.com International Support - Please contact your local Distributor. Distributor locations can be found at www.natus.com Warmette Blanket and Dual Cabinets User Manual ii

1 Safety Information...1 1.1 Intended Use... 1 1.2 Explanation of Terminology... 1 1.3 General Safety Information... 1 Safety Symbols... 3 2 Product Description...4 2.1 General Description... 4 2.2 Description of Function... 5 2.3 Environmental Conditions... 5 3 Installation...6 4 Operation...7 4.1 Operating the Warmette Cabinet... 7 4.2 Temperature Adjustment and Indication... 7 5 Troubleshooting Guide...8 6 Cleaning...9 7 Technical Section... 10 7.1 Temperature control/calibration... 10 7.2 Temperature regulation... 10 7.3 To Lock Temperature Setting (optional)... 11 7.4 To Change Unit of Measurement F or C Setting (optional)... 11 8 Specifications... 13 9 Spare Parts... 14 10 Circuit Diagrams... 16 Warmette Blanket and Dual Cabinets User Manual

1 Safety Information 1.1 Intended Use The Natus Warmette Blanket Cabinet is designed to store and warm blankets and hospital linens; while the Natus Warmette Dual Cabinet is designed to store and warm blankets and hospital linens in one compartment, and fluids (irrigation and/or injection) in the other compartment within the storage times and warming temperatures recommended by the manufacturers of those items. Important! Before installing or using either of the cabinets read all sections of this manual carefully. There are safety considerations that should be read and understood before use. 1.2 Explanation of Terminology This manual presents three types of precautionary information. The three types of statements carry equal weight; that is, they are of equal importance to the safe and effective use of the equipment. Each statement is categorized by using an introductory word in boldface as follows: Warning! Warnings indicate situations that, if not avoided, could result in serious injury or death to the patient or operator. Caution: Cautions indicate situations that, if not avoided, could result in minor to moderate injury to the patient or operator, or damage to the equipment. Note: Notes provide additional information to clarify a point in the text. 1.3 General Safety Information Before installing and operating the cabinet, read all sections of this manual carefully. Observe all precautions to ensure the safety of the patients and those using the equipment. In addition, please refer to your hospital policy and procedure for warming blankets and fluids. Warning! When using cabinet with Adjustable Feet: you must secure the cabinet to the wall using the built in brackets at the top of the Cabinet. Note: If the cabinet, at your own risk, is not secured to a wall, do not pull out more than one shelf/basket at a time. Warning! Cabinets on wheels are not intended for transport of hospital products. The intention of the wheels is to facilitate moving the cabinet for easy cleaning under and behind the cabinet. Note: When moving the cabinet make sure the wheels do not hit any obstacles. Roll the cabinet with its front in the direction of where you want to go. Warmette Blanket and Dual Cabinets User Manual 1

Warning! Never pull out all shelves/baskets at the same time. The cabinet can tilt forward if it is not properly secured to the wall. Warning! Cabinets on wheels must be rolled slowly and with great care. Warning! Risk of burning patient. If your cabinet temperature is set higher than 110 F (43 C) you must check that the contents are not too warm when they reach the patient. Warning! Risk of burning yourself. If your cabinet is set higher than 110 F (43 C) you must be careful when you touch contents and the inner surfaces of the cabinet. Warning! Do not warm Blood Products and Nutritional Products in the Cabinet. Warning! To avoid the risk of electric shock, this equipment must only be connected to a grounded outlet. Warning! Electrical shock hazard when the enclosure is open. Always unplug the power cord from the electrical outlet before cleaning or maintaining the equipment. Warning! Not suitable for use in the presence of flammable anesthetic mixtures with air, oxygen, or nitrous oxide. Caution: Do not overload the shelves/baskets. Maximum load on a shelf is 44 lbs (20 kg). Maximum load in a basket is 44 lbs (20kg). Caution: Do not overfill the top shelf - there must be at least 2 inches (5 cm) free space to ensure air circulation. Caution: Avoid blocking the ventilation holes inside of the cabinet. Caution: Ensure that the contents can withstand the temperature you have selected otherwise you may risk destroying the contents. Follow manufacturer recommended storage times and warming temperatures. Warmette Blanket and Dual Cabinets User Manual 2

Safety Symbols Warning! Be aware of the following symbols, which appear on the equipment. Symbol o ~ Meaning On Off AC Current Manufacture Date Manufacturer Attention, consult product documentation WEEE Directive (Waste from Electrical and Electronic Equipment Directive) Symbol Product should not be disposed of in normal waste UP button, rises temperature DOWN button, decreases temperature SET button, for displaying and changing desired temperature Warmette Blanket and Dual Cabinets User Manual 3

2 Product Description There are two kinds of large warming cabinets associated with this user manual: the Warmette Blanket Cabinet and the Warmette Dual Cabinet. The descriptions and instructions apply to both cabinets; unless noted otherwise. The Warmette Blanket Cabinet has a single compartment with four shelves for warming blankets or hospital linens; and includes four adjustable feet. This cabinet is factory-set to 130 o F (54 o C) maximum, with a temperature range of 95-176 o F (35-80 o C). The Warmette Dual Cabinet has one compartment on top for warming blankets or hospital linens with two blanket shelves, and one compartment on the bottom for warming fluids (irrigation and/or injection) with two fluid shelves and one fluid basket; and includes four adjustable feet. The blanket compartment is factory-set to 130 o F (54 o C) maximum with a temperature range of 97-176 o F (36-80 o C); and the fluid compartment is factory-set to 110 o F (43 o C) maximum, with a temperature range of 97-122 o F (36-50 o C). Note: The maximum temperature can be changed within the temperature range by reprogramming the regulator. 2.1 General Description CABINET The cabinet is made of stainless steel and is very well insulated in order to reduce heat loss to the environment and to reduce noise. For the same reason the doors are double glazed with safety glass. HEATING COMPARTMENT The heating element, fan, thermostat T2 and temperature sensor are all mounted on a "pull out shelf" inside the top of the cabinet. The heating compartment is kept in place by a small screw that, when loosened, allows the whole heating compartment to be pulled completely out. This makes service quick and easy. ELECTRONICS COMPARTMENT The electronics compartment is located on the top of the cabinet. The power cable is connected at the back of the electronic compartment. SHELVES/BASKETS The blanket shelves are mounted with screws. The fluid shelves/baskets run on wheels and can be pulled fully out until they automatically stop. To completely remove the fluid shelves/basket for cleaning or repositioning, lift the front upwards and remove. EXTRA SHELVES EXTRA BASKETS Extra shelves/baskets and rails are available. Mount the rails with the screws supplied using the prepared mounting holes and then push the shelf/basket in place by holding the front higher than the rear. Shelves in the Blanket Warming Cabinet are hung using the holes in the side walls. WHEEL KIT (OPTIONAL) A Wheel Kit is available to replace the adjustable feet and facilitate moving the cabinet for easy cleaning under and behind the cabinet Warmette Blanket and Dual Cabinets User Manual 4

2.2 Description of Function The cabinet and its contents are warmed by circulating warm air which is heated by a warming element. The hot air is circulated by a fan and distributed evenly through the outlets. The temperature is regulated, by the temperature regulator T1 to the set temperature. An over set temperature alarm has been programmed to produce an audible and visual alarm if the actual cabinet temperature goes higher than the set temperature by 10 F (6 C). The audible alarm will sound and the display will flash AL2 until the temperature has reduced to the approximate set temperature. The audible alarm can be stopped by pushing any button on the regulator. Thermostat T2 functions as over temperature protection and will take over the temperature control in case the air temperature exceeds the maximum range temperature by approximately 9 F (5 C). At the same time the red lamp on the front panel will be lit to indicate that there is a malfunction. Inside the heating element itself, there is an additional over temperature protection that is self-resetting. It will be activated in case the fan stops or goes too slow. The ON/OFF switch isolates the cabinet electronics from mains power. NOTE: If the red over temperature lamp is lit there is an error that requires a technician. 2.3 Environmental Conditions Normal Use: Temperature +50 to 93⁰F / +10 to 34⁰C Humidity 10-90% non-condensing Storage, Transport Temperature -13 to 122⁰F / -25 to 50⁰C Humidity 10 90% non-condensing Warmette Blanket and Dual Cabinets User Manual 5

3 Installation 1. Adjust the feet so that the cabinet is leveled (unless using with Wheel Kit accessory). 2. Secure the cabinet to the wall using the built in brackets at the top of the cabinet (unless using with Wheel Kit accessory). 3. Connect the cabinet to a grounded power outlet. Warning! When using cabinet with Adjustable Feet: you must secure the cabinet to the wall using the built in brackets at the top of the Cabinet. Warning! Cabinets on wheels are not intended for transport of hospital products. The intention of the wheels is to facilitate moving the cabinet for easy cleaning under and behind the cabinet. Note: When moving the cabinet make sure the wheels do not hit any obstacles. Roll the cabinet with its front in the direction of where you want to go. Warning! Cabinets on wheels must be rolled slowly and with great care. Warning! To avoid the risk of electric shock, this equipment must only be connected to a grounded outlet. 4. Do not position the cabinet so it will be difficult to disconnect the mains power cable. Warmette Blanket and Dual Cabinets User Manual 6

4 Operation 4.1 Operating the Warmette Cabinet 1. Switch on the Cabinet with the green power switch(es) at the upper front panel. 2. Check the set temperature and adjust if necessary according to 4.2 4.2 Temperature Adjustment and Indication The display shows the actual working temperature in the cabinet in F or C as long as the ON/OFF switch is on and the door is closed. The set temperature is indicated when the set button is pressed. The last set temperature is stored in the controller. The working temperature can be selected in steps of 1 degree within the range pre-set at the factory or by your technician. Note: The Warmette Blanket Cabinet is factory-set to 130 o F (54 o C) maximum. The Warmette Dual Cabinet is factory-set to 130 o F (54 o C) maximum for the blanket compartment and 110 o F (43 o C) maximum for the fluid compartment. Note: To change the maximum temperature, see section 7.3 Regulator SET UP Down Press SET button to show the set (selected) temperature. The set value is shown and the OUT lamp blinks for 2 sec. Press SET. Press UP arrow within 2 sec. to increase the temperature until the desired value is shown in the display. Press SET. Press DOWN arrow within 2sec. for a temperature decrease until desired value is shown in the display. Note: To lock the temperature setting see, section 7.4 Warmette Blanket and Dual Cabinets User Manual 7

5 Troubleshooting Guide Note: In the USA, contact Natus Technical Service at +1 (800)-303-0306 or E-mail: technical_service@natus.com. International Support - Please contact your local Distributor. Distributor locations can be found at www.natus.com. Warning! Electrical shock hazard when the enclosure is open. Always unplug the power cord from the electrical outlet before cleaning or maintaining the equipment. Note: All checking that involves opening the heating compartment must be done by a qualified technician. Ensure that the cables to the heating compartment do not get stuck when you close the heating compartment after service actions. If the warming is not starting, check as follows: Power in the wall socket? Power Switch on (If power is OK it will show a green light) Power cable connected? Cabinet fuses OK? Is the fan rotating? It shall start as soon as the power switch is on. If it is not rotating, making a strange noise or rotates slowly it must be changed. Check the fan and that the air intake under the heating compartment is not blocked. Red lamp lights up now and then. Check the capillary thermostat and the temperature regulating unit. Warmette Blanket and Dual Cabinets User Manual 8

6 Cleaning Clean and disinfect with normal surface detergents as per your hospital protocol. Clean the exterior of the cabinet with a cleaner recommended for stainless steel surfaces. Note: Avoid use of abrasive cleaners, chloride based cleaners, cleaners containing quaternary salts, or hydrochloric acid on stainless steel. Clean the window glass with a standard commercial glass cleaner. Warning! Electrical shock hazard when the enclosure is open. Always unplug the power cord from the electrical outlet before cleaning or maintaining the equipment. Warmette Blanket and Dual Cabinets User Manual 9

7 Technical Section 7.1 Temperature control/calibration To be performed yearly by a qualified technician only. GENERAL INFORMATION Power Cable: Check the integrity of the power cable and verify proper grounded connection. The working temperature is regulated by the temperature regulator T1 and the over temperature protection by capillary thermostat T2. When checking the calibration of T1 and T2, their value shall be compared to the value of a precision thermometer with an air sensor. Place the sensor of the precision thermometer in the middle of the cabinet. Allow at least 1 hour for proper warming up. 7.2 Temperature regulation INFORMATION ABOUT TEMPERATURE MEASUREMENT AND CALIBRATION T1 is a powered microprocessor temperature regulator/indicator that has resolution of 1 F or C. Corrections can be done through a series of button pushes on the regulator according to the description below. PROCEDURE Place the external control sensor as described under GENERAL INFORMATION above. Start the warming and wait until the temperature is stable (at least 1 hour). Compare the external control thermometer with the set temperature and if the deviation is bigger than +/-1 F or C adjust as follows. On the regulator: 1. Press and exactly simultaneously (only one beep may be heard, if you don t succeed- repeat) and keep buttons pressed for 5 sec until the indicator display shows PA. 2. Press SET one time. 3. Press within 15 sec until -19 is displayed. 4. Press SET one time. 5. Press and exactly simultaneously until SP (Select Parameter) is displayed 6. To change a parameter press or button till parameter CA1 is received. 7. Press SET once and within 2 sec on or button to enter the noted temperature difference. Press SET again. For example: The display shows 130 F but the external control temperature shows 127 F. The difference is -3 F. To compensate this difference press button 3 times. Store the new calibrated value by pressing and simultaneously (only one beep may be heard, if you don t succeed- repeat) and keep pressed for 5 sec until the indicator display shows the actual temperature. 8. Make a new measurement of the temperature and control that T1 shown value compares to that of the external thermometer. Warmette Blanket and Dual Cabinets User Manual 10

7.3 To Change the Maximum Temperature (optional) PROCEDURE 1. Follow the procedure above, step 1-5. 2. Use the or button and step to r2. Press the SET button and change the maximum temperature set point using the arrow buttons. 3. Press SET again and then press and hold and buttons until the temperature is displayed and you are done or cycle the power Off/On to set the new values. 4. Press SET again and set the temperature to the desired set point and let the cabinet temperature stabilise. Note: Think carefully about the risks and consequences of setting the max temp limit higher than the factory set temperature and about how to make the staff aware of higher settings. 7.4 To Lock Temperature Setting (optional) To lock the display from changing the temperature you will need to perform the following steps and enter the programming mode: PROCEDURE 1. Before you lock the display, enter the temperature you want it to be set to (i.e. 105⁰F). 2. Press and hold and simultaneously (only one beep will be heard) on the display until PA is displayed. 3. Press the SET button 4. Press the down button ( ) until -19 is displayed. 5. Press the SET button again and then press and hold and until SP is displayed. 6. Use the or button and step to r3. This is where you set the flag for locking the set temperature. Press the SET button and change the value by using the arrow button from 0 to 1. 7. Press SET again and then press and hold and buttons until the temperature is displayed and you are done or cycle the power Off/On to set the new value. 7.5 To Change Unit of Measurement F or C Setting (optional) To change the unit of measurement displayed (Fahrenheit or Celsius) you will need to perform the following steps and enter the programming mode: PROCEDURE 1. Press and hold and simultaneously (only one beep will be heard) on the display until PA is displayed. 2. Press the SET button 3. Press the down button ( ) until -19 is displayed. 4. Press the SET button again and then press and hold and until SP is displayed. 5. Use the or button and step to P2. Press the SET button and change the value using the arrow button ( 0 = C; 1 = F). 6. Press the SET button Warmette Blanket and Dual Cabinets User Manual 11

7. Use the or button and step to r1. Press the SET button and change the minimum temperature set point using the arrow buttons (i.e. 95 F or 35 C) 8. Press the SET button 9. Use the or button and step to r2. Press the SET button and change the maximum temperature set point using the arrow buttons 10. Press SET again and then press and hold and buttons until the temperature is displayed and you are done or cycle the power Off/On to set the new values. Note: After changing the unit of measurement, it is necessary to change the set temperature value. Press the SET button and arrow buttons to increase or decrease the temperature until the desired value is shown in the display. Warmette Blanket and Dual Cabinets User Manual 12

8 Specifications Outside Dimensions (Blanket & Dual Cabinets) With Adjustable Feet (standard) Height 71.25-73.25 in (181-186 cm) Width 26 in (66 cm) Depth 25 in (64 cm) With Wheel Kit (optional) Height Width Depth 72.5 in (184 cm) 26 in (66 cm) 25 in (64 cm) Inside Dimensions (H x W x D) Blanket Cabinet 55 x 22 x 21 in (140 x 56 x 53 cm) Dual Cabinet 23 x 22 x 21 in (59 x 56 x 53 cm) x 2 Inside Volume Blanket Cabinet Dual Cabinet (blanket + fluid) Maximum load per shelf/basket Weight Blanket Cabinet Dual Cabinet Electrical Power Rating Blanket Cabinet Dual Cabinet 14.66 ft³ (415 liters) 5.65 ft³ (160 liters) + 5.65 ft³ (160 liters) 44 lbs (20 kg) 309 lbs (140 kg) 353 lbs (160 kg) 120V~, 60Hz 230V~, 50Hz 550 W 1100 W Average Power Consumption Blanket Cabinet Dual Cabinet Temperature Range Blanket Cabinet Dual Cabinet (blankets) Dual Cabinet (fluids) Accuracy Blanket Cabinet Dual Cabinet (blankets) Dual Cabinet (fluids) Regulatory Standards 100-250 W 150-250 W 95-176 F (35-80 C); factory set to 130 F (54 C) maximum 97-176 F (36-80 C); factory set to 130 F (54 C) maximum 97-122 F (36-50 C); factory set to 110 F (43 C) maximum ±7.2 F (± 4 C) ±7.2 F (± 4 C) ±3.6 F (± 2 C) IEC/EN 61010-1, 2 nd Ed. IEC 61010-2-01:2003 UL 61010-1/CSA-C22.2 No. 61010-1, 2 nd Ed, 2004, rev. Oct 2008 EN 61326-1:2013 (230V only) FCC Part 15 Subpart B class A (120V only) Warmette Blanket and Dual Cabinets User Manual 13

9 Spare Parts Part no Picture Position Description 012412 Casters (set of 4), Warmette Cabinet 1 012927 4 Mains Power Switch, Warmette Cabinet 1 012928 8 Fan (36/23W 120V) Warmette Cabinet 1 012929 12 Heater (2 x 500W, 115V) Warmette Cabinet 1 012930 9 Temperature Sensor, Warmette Cabinet 1 012931 5 Temperature Regulator, Warmette Cabinet 1 012932 6 Thermostat 16A 115V, Warmette Cabinet 1 012933 7 Red Lamp, Warmette Cabinet 1 012934 Magnetic Handle for Door, Warmette Cabinet 1 012935 Wall Mounting Bracket (set of 2), Warmette Cabinet 1 012936 Door Gasket, Warmette Cabinet 5m 012937 Foot for cabinet, Warmette Cabinet 1 012938 13 Fuse(6.3A 125V) Warmette Large Blanket Cabinet 2 012939 Glass for door, Warmette Large Blanket Cabinet 1 012941 13 Fuse(10A 125V) Warmette Large Combination Cabinet 2 013256 Glass for door, Warmette Dual Cabinet (700-0212) 1 013350 13 Fuse (6,3AL 250V) Warmette Blanket Cabinet 230Vac version 2 013351 13 Fuse (10AL 250V) Warmette Large Combination Cabinet 230Vac version Quantity 2 Warmette Blanket and Dual Cabinets User Manual 14

Warmette Blanket and Dual Cabinets User Manual 15

10 Circuit Diagrams Warmette Blanket and Dual Cabinets User Manual 16