Heat Recovery Ventilators models:

Similar documents
User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

READ AND SAVE THESE INSTRUCTIONS

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS

Address of your installer

HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V

HEAT RECOVERY VENTILATORS AND ENERGY RECOVERY VENTILATORS CONSTRUCTO 1.0 MODELS: Model no.: (HRV with ports on top)

VIGÖR HRV PLUS AND VIGÖR ERV

HEAT RECOVERY VENTILATORS MODELS AVS E15 ECM HRV, AVS E15 HRV, AVS E10 HRV AND ENERGY RECOVERY VENTILATOR MODEL AVS E15 ECM ERV

USER GUIDE HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+, MODEL ERV 90H-V ECM PLEASE READ AND SAVE THESE INSTRUCTIONS

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

USER MANUAL HRV150S* HRV190S* AND ERV180S READ AND SAVE THESE INSTRUCTIONS

Address of your installer

HEAT RECOVERY VENTILATORS HRV 60H ERV 60H. User Guide AND ENERGY RECOVERY VENTILATORS. Model no.: (HRV with ports on top)

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

HEAT RECOVERY VENTILATOR

Heat Recovery Ventilation Systems OWNER S GUIDE

ENERGY RECOVERY VENTILATOR

Indoor Air Quality Product Brochure.

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

Indoor Air Quality Product Brochure.

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

INSTALLATION GUIDE VB0180 VB0148

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

Installation Information

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

For Models Superventor Series

Limited Lifetime core warranty. 5-year warranty on balance of unit.

FOR MODELS: VENMAR 1.3, 1.8 & 2.6 HE VENMAR 3055 & 5585 COMPACT vänee 1000, 2000 & 3000 HE

TR Series - The Ultimate ERV

HOME OWNERS GUIDE ERV MODEL PE 7.15 PE SS Product of Imperial Air Technologies

Heat or Energy Recovery Ventilation System

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

INSTALLATION GUIDE FOR VENMAR AVS CONSTRUCTO 1.5* AND CONSTRUCTO 2.0

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTION & OWNER S GUIDE

Tech to Tech May 07 HRV s & ERV s

UNDER CABINET RANGE HOOD

Put the V back in HVAC

READ CAREFULLY AND SAVE R3

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER

TECHNICAL SPECIFICATIONS

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

Operating Instructions. for your Ford & Doonan Ducted System

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

The best way to enhance indoor air quality

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

CMHC HOME MAINTENANCE CHECKLIST

IAQ VENTILATION SOLUTIONS

SAFETY AND INSTALLATION MANUAL MODEL 8100

OPERATOR S MANUAL FOR YOUR SAFETY. 4 Gallon / Liter Part No. PB408SV

SLIDER CASEMENT AIR CONDITIONER

Bosch Split-Type Ductless Air Conditioner / Heat Pump

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

CLEANING & MAINTENANCE For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild d

Ventilation Solutions IAQ Canada

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

INSTALLER AND USER MANUAL VENTILATION SYSTEM

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

Inverter Split-type Room Air Conditioner

INSTALLER MANUAL RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS

USER S MANUAL AQV09J Series AQV12J Series AQV18J Series AQV24J Series

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY

BUILT-IN OVEN MODEL: EBO-D7080D(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE.

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Fig. 1 - Unit PHD4 and WPH4

user s information manual

2 Finding Information

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

Max Series 5 Speed Electronics Lifestyle MAX Digital Control included

ROTARY CONTROL AIR CONDITIONER

IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER

Condensation on Your Windows?

DH 100 P. Always Dry dehumidifier. with. Condensation Removal System

IAQ VENTILATION SOLUTIONS

HR150B, HR200B Perfect Window Fresh Air Ventilation Systems

Model: AW600. Triple Action Humidifier. Winix Inc. 120 Prairie Lake Road U nit E East Dundee, IL USA

G61MPV SERIES GAS FURNACE WARNING

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

OWNER S MANUAL. Portable Air Conditioner. Product defect? Not working properly? DO NOT return this product to the store where you purchased it.

Room Air Conditioner Service and Parts Manual

Owner s Information Manual

user manual Model #: BLZ-HOOD

OPERATING INSTRUCTIONS

about your house Assessing the Comfort and Safety of Your Home s Mechanical Systems

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

READ AND SAVE THESE INSTRUCTIONS OWNER S MANUAL FOR BYPASS AND FAN POWERED HUMIDIFIERS. Small or Large Bypass 12 Water Saver Bypass 13 Fan Powered 14

INSTALLATION GUIDE FOR VENMAR AVS UNIT CONSTRUCTO 1.0 HRV AND CONSTRUCTO 1.0 ERV

INSTRUCTION MANUAL Model: SU3022

Operator s Manual. Floor Vac Model No. VF408 FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference

user manual Model #: BLZ-WVH-42

Transcription:

User s Manual Read and save these instructions. Heat Recovery Ventilators models: 1000 HE 2000 HE 3000 HE 3055 Compact HE 1.3 HE 1.8 HE 2.6 5585 Compact VB0021 VVI, 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 04/01 #02053

Congradulations! You have made an excellent choice! The operating principle of your Heat Recovery Ventilator will protect your house and give you personnal comfort you have never known before. We have prepared this Operating Guide especially for you. Please read it carefully to ensure you obtain full benefit from your Heat Recovery Ventilator unit. Over the coming months, you will increasingly appreciate the feeling of living in a more comfortable house. Please take note that this manual uses the following symbols to emphasize particular information:! WARNING Identifies an instruction which, if not followed, might cause serious personal injuries including possibility of death. CAUTION Denotes an instruction which, if not followed, may severely damage the unit and/or its components. NOTE: Indicates supplementary information needed to fully complete an instruction. We welcome any suggestions you may have concerning this manual and/or the unit, and we would appreciate hearing your comments on ways to better serve you. Please forward all correspondence to us at the address indicated on the product registration card included with this manual. CAUTION Make sure at all times that the outside hoods are free from any snow during the winter season. It is important to check your unit during a big snow storm, so it doesn t draw in any snow. If this is the case, please operatre the unit in the circulation mode, or OFF mode, for a few hours. Do not use your HRV during construction or renovation of your house or when sanding drywall. This type of dust may damage your system. Since the electronic control system of the unit is incorporated with a microprocessor, it may not operate correctly because of external noise or very short power failure. If this happens, unplug the unit and wait approximately 10 seconds. Then, plug the unit in again. I

Table of contents 1.0 Functions of your HRV.......................... 1 1.1 Air Exchange........................................... 1 1.2 Heat Recovery.......................................... 1 1.3 Circulation............................................. 2 2.0 Diagrams of air flows.......................... 3 3.0 Description of unit............................ 5 4.0 Operating the Wall Control...................... 7 4.1 Basic and Venta Controls................................. 8 4.2 Electro and Supra Controls............................... 9 4.3 Detector Control....................................... 10 4.4 Ultima Control......................................... 11 5.0 Maintenance................................ 12 5.1 Regular Maintenance...................................12 5.2 Annual Maintenance...................................12 6.0 Troubleshooting.............................. 13 II

1.0 Functions of your HRV Your Heat Recovery Ventilator eliminates the problems of excessive humidity by exhausting stale and humid air to the outside and by drawing in fresh air. The unit offers superior air quality and fresh air sensation, an important factor to overall comfort, by eliminating the accumulation of pollutants and humidity. The unit also comes equipped with a heat recovery core which reduces ventilating costs in winter. The Heat Recovery Ventilator is a Ventilation system which carries out three main operation: 1.1 Air Exchange The unit exhausts stale and humid air from the house and replaces it with fresh air from the outside. MODELS 1000 HE / HE 1.3 / 3055 Compact 2000 HE/ HE 1.8 5585 Compact 3000 HE / HE 2.6 1.2 Heat Recovery During winter, the unit recovers the heat contained in the stale air before it is exhausted, and transfers it to the fresh air drawn from the outside (reverse process in summer). Example: (in winter) RATES 30 to 60 l/s (65 to 130 cfm) 55 to 93 l/s (115 to 197 cfm) 55 to 92 l/s (117 to 195 cfm) 85 to 141 l/s (180 to 300 cfm) FRESH AIR FROM OUTSIDE 0 C/32 F STALE AIR TO OUTSIDE 3 C/37 F STALE AIR FROM BUILDING 22 C/72 F VF0024 FRESH AIR TO BUILDING 19 C/66 F 2000 HE, 3000 HE, HE 1.8, HE 2.6 1

1.0 Functions of your HRV (cont d) 1.2 Heat Recovery (cont d) STALE AIR TO OUTSIDE 4 C/39 F Example: (in winter) FRESH AIR TO BUILDING 18 C/64 F FRESH AIR FROM OUTSIDE 0 C/32 F VF0026 STALE AIR FROM BUILDING 22 C/72 F 1000 HE, HE 1.3, 3055 Compact, 5585 Compact 1.3 Circulation (available with ULTIMA control only) During the circulation mode, when the selected level of humidity is reached, the unit stops to exchange air with the exterior. Continuous circulation is thus undertaken inside the home and insures the purification of the ambiant air. A mechanical filter traps the large dust particles (those visible to the eye). 2

2.0 Diagrams of Air Flows The direction of the air flow is indicated in each of the following diagrams. Please note that the stale air never mixes with the fresh air. MODELS 1000 HE, HE 1.3, 3055 Compact, 5585 Compact during air exchange FRESH AIR FROM OUTSIDE STALE AIR TO OUTSIDE FRESH AIR TO BUILDING STALE AIR FROM BUILDING VF0010 during defrost mode FILTERED AIR TO BUILDING STALE AIR FROM BUILDING VF0003 3

2.0 Diagrams of Air Flows (cont d) MODELS 2000 HE, 3000 HE, HE 1.8, HE 2.6 during air exchange STALE AIR TO OUTSIDE FRESH AIR TO BUILDING STALE AIR FROM BUILDING FRESH AIR FROM OUTSIDE during circulation and defrost VF0025 FILTERED AIR TO BUILDING STALE AIR FROM BUILDING VF0002 4

3.0 Description of the Unit 1) Stale air intake port: is connected to the registers located in the larger rooms of the house. 2) Fresh air port: brings fresh air from the outside into the unit. 3) Exhaust port: exhausts stale air to the outside, after the air has transferred its heat inside the heat recovery core. 4) Distribution port: distributes fresh air into the house, after it has absorbed the heat of the stale air in the heat recovery core. 5) Foam filter: traps the dust contained in the air and prevents the heat recovery core from becoming obstructed. 6) Heat recovery core: is a counterflow type for 2000 HE, 3000 HE, 1.8 HE, 2.6 HE models and is a crossflow type for the other models. It transfers the heat between the two air streams. 7) Blowers: draw fresh air from the outside and exhaust stale air to the outside. The blower wheels are driven by two motors for 2000 HE, 3000 HE, 1.8 HE, 2.6 HE models. The other models have just one motor. 8) Capacitor: is indispensable to proper motor operation. 9) Condensation tray: is used to capture the water produced during heat transfer and defrost. (in cold climate) 10) Drainage tube: is connected to the condensation tray and serves to drain the water within. 11) Electronic control circuit: located inside the electrical box, insures proper operation of the unit. 12) Automatic defrost unit: consists of one damper actuator, dampers and the related controls. The defrost cycle is electronically controlled in response to the outside temperature (-5 C (23 F) to -40 C (-40 F)) and will increase in frequency as the temperature decreases. Its duration is of 5 or 6 minutes according to models. 13) Control Connector: located inside the electrical box, allows to connect the control and override switch as a timer, a dehumidistat or a switch. 14) Electrical cord: for 120V electrical supply. 5

2 4 1 14 MODELS 1000 HE, HE 1.3, 3055 Compact, 5585 Compact 3 12 6 8 7 11 13 5 10 9 VL0003 MODELS 2000 HE, 3000 HE, HE 1.8, HE 2.6 4 1 14 3 2 12 5 6 7 7 8 11 13 5 10 9 VL0012 6

E SUMMER SUMMER 4.0 Operating the Wall Controls The following illustrations show the main controls. Refer to next pages for operating instructions. 1000 HE HE 1.3, HE 1.8, HE 2.6 2000 HE 3585 Compact 3000 HE 5585 Compact CONDENSATI0N CONTROL -20 C -4 CO NE AIR SUPPLY CONTROL OFF MIN. MAX. AIR EXCHANGE VC0035 BASIC VC0010 VENTA CONDENSATI0N CONTROL -4 C M Z O E C 41 F CONDENSATION CONTROL MAXIMUM SPEED AIR SUPPLY CONTROL AIR EXCHANGE IN PROGRESS MIN. MAX. 20 MIN. ON 40 MIN. OFF CONTINUOUS INTERMITTENT VC0036 ELECTRO VC0011 SUPRA POLLUTANT CONTROL ITY Pollutant POLLUTANT CONTROL MAXIMUM SPEED AIR SUPPLY CONTROL AIR EXCHANGE IN PROGRESS MIN. MAX. 20 MIN. ON 40 MIN. OFF CONTINUOUS INTERMITTENT VC0037 DETECTOR VC0013 ULTIMA 7

4.0 Operating the Wall Controls (cont d) 4.1 Basic and Venta Controls Purpose: To adjust air supply and select desired indoor humidity level. ADJUSTING AIR SUPPLY CONTROL 1) Select speed MIN. or MAX. using slide switch. When MIN. (minimum speed) is selected, if the knob is set above the click, the unit will exchange in low speed with the outside and if it is set below the click, the unit will exchange on high speed with the outside until the desired humidity level has been reached. When MAX. (maximum speed) is selected, the unit will exchange on high speed with the outside either if the knob is set below or above the click. 2) To turn off the unit, slide the switch at the OFF position. ADJUSTING HUMIDITY CONTROL Setting during the summer months: During this period, unless being afflicted with breathing problems, using the humidity control is unnecessary. Set the slide switch to OFF. (Do not exchange in day time; exchange at night time, if cool outside, or if it is not raining.) Setting during the fall, winter and spring months: (When condensation appears on windows) 1) Determine the humidity level in your house (bring the knob counterclockwise to its maximum position, then bring it back clockwise slowly until you hear a click ). 2) Set the knob to one line under this temperature level or click. CAUTION Do not select a temperature below -20 C (-4 F). This could lead to excessive dryness in the air causing discomfort for the occupants. It is possible (and normal) to experience condensation on your windows when drastic changes in temperature happen (for example: -5 C (23 F) to -20 C (-4 F)). In that case, we suggest waiting a few days to allow the situation to stabilize. 8

4.0 Operating the Wall Controls (cont d) 4.2 Electro and Supra Controls Purpose: To adjust air supply and select desired indoor humidity level. ADJUSTING AIR SUPPLY CONTROL 1) Select speed MIN., MAX. or INTERMITTENT using the push button. When MIN. (minimum speed) is selected, if the knob is set above the click, the unit will exchange in low speed with the outside and if it is set below the click, the unit will exchange on high speed with the outside until the desired humidity level has been reached. When MAX. (maximum speed) is selected, the unit will exchange on high speed with the outside either if the knob is set below or above the click. When INTERMITTENT is selected, the unit will exchange with the outside on low speed (or on high speed if the knob is set below the click), during 20 minutes per hour. NOTE: When INTERMITTENT signal is flashing, this means you have to clean your filters. 2) To turn off the unit, activate the push button once again. ADJUSTING HUMIDITY CONTROL Setting during the summer months: During this period, unless being afflicted with breathing problems, using the humidity control is unnecessary; turn off the unit. (Do not exchange in day time; exchange at night time, if cool outside, or if it is not raining.) Setting during the fall, winter and spring months: (When condensation appears on windows) 1) Determine the humidity level in your house (bring the knob counterclockwise to its maximum position, then bring it back clockwise slowly until you hear a click ). 2) Set the knob to one line under this temperature level or click. CAUTION Do not select a temperature below -20 C (-4 F). This could lead to excessive dryness in the air causing discomfort for the occupants. It is possible (and normal) to experience condensation on your windows when drastic changes in temperature happen (for example: -5 C (23 F) to -20 C (-4 F)). In that case, we suggest waiting a few days to allow the situation to stabilize. 9

4.0 Operating the Wall Controls (cont d) 4.3 Detector Control Purpose: To adjust air supply and detect indoor pollutants. ADJUSTING AIR SUPPLY CONTROL 1) Select speed MIN., MAX. or INTERMITTENT using the push button. When MIN. (minimum speed) is selected, if the knob is set above the click, the unit will exchange in low speed with the outside and if it is set below the click, the unit will exchange on high speed with the outside until the detected pollutants has been exhausted. When MAX. (maximum speed) is selected, the unit will exchange on high speed with the outside either if the knob is set below or above the click. When INTERMITTENT is selected, the unit will exchange with the outside on low speed (or on high speed if the knob is set below the click), during 20 minutes per hour. NOTE: When INTERMITTENT signal is flashing, this means you have to clean your filters. 2) To turn off the unit, activate the push button once again. ADJUSTING POLLUTANT CONTROL 1. Set the sensitivity knob at the maximum position. 2. Plug in the unit and set the AIR SUPPLY CONTROL to MIN. 3. Wait 5 minutes. 4. Put a pollution source (cigarette smoke, perfume or other strong vapors) near the control. Wait one minute. The unit should switch to high speed. 5. Unplug the unit, wait 30 seconds and plug back in. Set the knob to medium (normal) sensitivity before leaving the house. You should wait up to 48 hours before attempting any adjustments to your DETECTOR control. (This waiting period will allow the control to restabilize after the test.) NOTE: If the pollution level of the surrounding air is very high, this procedure (5 steps) might not provoke high speed operation. If this is the case, allow the polluted air to clear by operating the unit at MAX. for several hours. Then, unplug the unit, wait 30 seconds, plug back in, and redo the procedure. 10

4.0 Operating the Wall Controls (cont d) 4.4 Ultima Control Purpose: To adjust air supply and select desired indoor humidity level. ADJUSTING AIR SUPPLY CONTROL 1) Select speed MIN., MAX. or INTERMITTENT using the push button. When MIN. (minimum speed) is selected, if the knob is set above the click, the unit will exchange in low speed with the outside and if it is set below the click, the unit will exchange on high speed with the outside until the desired humidity level has been reached. (Green indicator is for exchange at low speed and red indicator is for circulation at low speed). When MAX. (maximum speed) is selected, the unit will exchange on high speed with the outside either if the knob is set below or above the click. (Green indicator is for exchange at high speed and red indicator is for circulation at high speed) When INTERMITTENT is selected, the unit will exchange with the outside on low speed (or on high speed if the knob is set below the click), during 20 minutes per hour. (Green indicator is for 20 min. exchange at low speed and 40 min. OFF and red indicator is for 20 min. exchange at low speed and 40 min. of circulation at high speed) NOTE: When INTERMITTENT signal is flashing, this means you have to clean your filters. 2) To turn off the unit, activate the push button once again. ADJUSTING HUMIDITY CONTROL Setting during the summer months: During this period, unless being afflicted with breathing problems, using the humidity control is unnecessary; turn off the unit. (Do not exchange in day time; exchange at night time, if cool outside, or if it is not raining.) Setting during the fall, winter and spring months: (When condensation appears on windows) 1) Determine the humidity level in your house (bring the knob counterclockwise to its maximum position, then bring it back clockwise slowly until you hear a click ). 2) Set the knob to one line under this temperature level or click. CAUTION Do not select a temperature below -20 C (-4 F). This could lead to excessive dryness in the air causing discomfort for the occupants. It is possible (and normal) to experience condensation on your windows when drastic changes in temperature happen (for example: -5 C (23 F) to -20 C (-4 F)). In that case, we suggest waiting a few days to allow the situation to stabilize. 11

5.0 Maintenance 5.1 Regular Maintenance WARNING! Risk of electric shock. Before performing any maintenance or servicing, always disconnect the unit from its power source. 1) The motors are factory lubricated for life. Lubricating the bearings is not recommended. CAUTION Because the unit is suspended, two people are recommended to remove or install the heat recovery core. Do not hold the heat recovery core using its plastic extrusions as handles. 2) The heat recovery core must be handled with care. We recommend that it be washed once a year, following the season of most intense use, in order to insure maximum efficiency of the plastic partitions. Allow the heat recovery core to soak for 3 hours in a solution of warm water and mild soap. Rinse under a heavy stream of water. CAUTION Hot water and a strong detergent will damage the heat recovery core. 3) The air filters are washable. Under normal conditions, we recommend that they be washed every 3 months. - Use a vacuum cleaner to remove the heaviest portion of accumulated dust. Then wash in hot water. 4) Regularly check the screen on the exterior intake hood and clean when necessary. Also check during very cold weather because ice may grow on the screen located at the exterior intake hood. 5.2 Annual Maintenance NOTE: Ask your installer for an annual service contract. Annual service should include: 1) Cleaning filters, heat recovery core and the exterior air intake/exhaust hood. 2) Cleaning the wheels and the blower blades. 3) Cleaning the condensation tray with soapy water (make sure that the drain is not clogged). 4) Running the system and checking the different operating modes. 5) Measuring and calibrating rates of flow. 12

6.0 Troubleshooting TYPES OF PROBLEM TRY THIS... 1 Nothing works. Check if the unit is plugged in. Check if the unit is receiving power from the house circuit breaker. 2 Condensation on windows. Adjust the humidity control knob as per instructions (see Section 4). Operate the unit at maximum speed during activities generating excess humidity (family gatherings, extra cooking, etc.). Leave curtains half-open to allow air circulation on windows. Store wood in a closed room with a dehumidifier or have the room well ventilated with outside air or store the wood outside. Do not adjust the thermostat of your heating system below 18 C (64 F). 3 Air too dry Do not adjust your humidity control below -20 C (-4 F). Operate the unit at low speed. Temporarily stop air exchange. Temporarily use a humidifier. 4 Air too cold at the air supply grille Make sure the stale air exhaust hood, outside the house, is not blocked. Operate the unit at low speed. Have the system balancing checked. Have the unit defrosting system checked. Install a duct heater. 13