Service Manual. DCXXXX, DEXXXX Model Compressor Refrigerators MODELS DC0040(K), DC0051(K) DE0040, DE0051 DE0240T, DE0251T DC0740(X), DE0740(X)

Similar documents
For Models: DE 441, DE461, DE451, DE490, DC440, DC451, DC490, MRFT415, MRFT440, MRFT460

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

Part 3 Troubleshooting

INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool Remote Condensing units & Cold plates.

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING

Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850

The breaker trips at once when it is set to ON. The breaker trips in few minutes when it is set to ON.

3.2 E1 Outdoor Unit PCB Abnormality E4 Actuation of Low Pressure Sensor E5 Compressor Motor Lock 3 52

User Manual & Operating Instructions

INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool AC/DC and DC only Refrigerators and Freezers.

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T53 Model

T-Series Air Conditioner T20 Model

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Aprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

TFFR01 MANUAL PORTABAL 12/24 VOLTS DC REFRIGERATOR / FREEZER.

CAUTION. No-Load Performance, Controls in Normal Position

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

KM-61BAH KM-101BAH KM-151BAH

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

CAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

USER GUIDE 30L 40L 50L. Instruction Manual. IFRIDGE30 (30L), IFRIDGE40 (40L) and IFRIDGE50 (50L) CAPACITY CAPACITY CAPACITY

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

Container Refrigeration

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

TECH SHEET DO NOT DISCARD PAGE 1. If unsuccessful entry into diagnostic mode, actions can be taken for specific indications:

TRAVELMATE. Instruction Manual

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

Hoshizaki America, Inc.

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

PRIMUS IMPORTANT. User Manual and Product Specifications. Portable Fridge/Freezer. Part No. PRI18LP - 18 Litre. Read instructions before operation.

12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker.

ART TEC Solar Differential Temperature Controller DTC-1 Manual

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

Samsung EHS Heat Pump Test

SEA FROST BD 12 OR 24-VOLT D.C. AIR-COOLED SYSTEM

Room Air Conditioner Service and Parts Manual

Operating & Maintenance Manual for Islandaire Packaged Terminal Thru-Wall Air Conditioners & Heat Pumps

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Fast Track Troubleshooting

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

SERVICE MANUAL REFRIGERATION

Instruction Manual. Please read this manual and the Safety Instructions carefully before using your refrigerator.

Service Manual Model 3163

SERVICE MANUAL FOR 6795B,C,D SERIES PACKAGED AIR CONDITIONERS

RSMSD Technical Guide

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

TECHNICAL DATA & SERVICE MANUAL

Installation, Operation, and Maintenance Information

This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified.

Service Manual Gas/Electric Refrigerators

TECHNICAL SERVICE GUIDE

FOR SERVICE TECHNICIAN S USE ONLY

M52 3-Phase INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

Service instruction Cold

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

Dishwasher Cycle Chart Condensation Dry System

CLOTHES DRYER Technical Information

DryAire DRYING CABINET

SERVICE MANUAL. Model 47L(50 qrt) 35L(37 qrt) 60L(63 qrt) 78L(82 qrt) Type

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Heat Pump Water Heater (Generation 4) Troubleshooting (Effective 1 Nov 2016)

INSTRUCTION MANUAL PORTABLE FRIDGE/FREEZER. Models: RVX-35 / RVX-45 / RVX-50 RVX-55 / RVX-65 / RVX-75

AC/DC PORTABLE FRIDGE/FREEZER

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL

Room Air Conditioner Service and Parts Manual

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R

SERVICE MANUAL PORTABLE AIR CONDITIONER WAP-237EB NEW WIDETECH V 50Hz

SunRotor Solar Pump Installation Guide

Fast Track Troubleshooting

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS

WFR 2460 Service Tips -- Test Program

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

FROST FREE REFRIGERATOR INSTRUCTION MANUAL

Northwest RV Supply Manual Compliments of Printed From 900 & 9100 Series

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

FOR SERVICE TECHNICIAN S USE ONLY

Operating & Maintenance Manual for Islandaire EZ Series WM/LM Water Source Heat Pump Packaged Terminal Air Conditioners.

Instruction Manual. By Evakool. Please read these instructions and the Safety section carefully before using your refrigerator.

Fast Track Troubleshooting

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

INSTRUCTIONS! DO NOT DISCARD!

Hoshizaki America, Inc.

Fast Track Troubleshooting

USER MANUAL. Adventure Kings 50L Refrigerator

Room Air Conditioner EP08 & EP12. Chill 115 Volts-EP Volts-EP12. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

Transcription:

Service Manual DCXXXX, DEXXXX Model Refrigerators MODELS DC0040(K), DC0051(K) DE0040, DE0051 DE0240T, DE0251T DC0740(X), DE0740(X) DC0751(X), DE0751(X) Please note that the "X" at the end of certain model numbers indicates the equipment color; where "X" can be "B" (black), "S" (stainless steel, or "W" (wrapped door - stainless steel). 2007 NORCOLD, INC. All rights reserved. Part No. 631842A (08-08-07)

Table of Contents Troubleshooting - Procedure A Doesn't Run with Thermostat "On"...3 Troubleshooting - Procedure B Resistance...4 Measuring the Resistance...4 Troubleshooting - Procedure C Output Voltage...5 Troubleshooting- Procedure D Measuring Amp Draw...6 Troubleshooting - Procedure E Verifying Thermistor Operation...7 Troubleshooting - Procedure F Insufficient Cooling...8 Troubleshooting - Procedures G Refrigerator is Too Cold...8 Troubleshooting - Procedure H Auto Shut-Off Device...8 Operating the Shut-Off Device...8 Troubleshooting - Procedure I Proper Ventilation...9 Wiring Schematic...9 Troubleshooting - Quick Reference Quick Reference Troubleshooting Steps...10! WARNING! Perform all tests using a fully charged 12V DC battery. Using other equipment that supplies DC voltage may cause permanent refrigerator component failure. 2 DC0040(K), DC0051(K), DE0040, DE0051, DE0240T, DE0251T, Refrigerator Service Manual

Troubleshooting - Procedure A Doesn't Run with Thermostat "On" Thermostat ON Does Not Run Is Temperature Control LED on? NO YES Measure Terminal Voltage Of Temperature Control Between TP1 & TP2. (See Figure 1) DC 0V DC 2V DC 5V DC OPERATION AC OPERATION Check AC (37 45V DC) (See Figure 5) Normal BAD GOOD Short Circuit Short Circuit See Procedure B Change AC Check Supply Voltage (10.5 32V DC) (85 132V AC) CORRECT INCORRECT Correct Voltage Runs NO YES OK ART01945 Power Source AC DC Measure Terminal Voltage of Temperature Control Between TP2 & TP3. (See Figure 1) Check Both DC Fuses BLOWN OK DC 0V DC 12 to 32V DC OPERATION AC OPERATION Check DC Polarity OK Replace 10A Fuse (See Figure 2) Normal INCORRECT See Procedure B Reverse Polarity & Check Operation (Red + / Black -) Runs NO YES Check AC (37 45V DC) (See Figure 5) BAD Replace 10A Fuse (See Figure 2) OK GOOD Runs NO YES OK Change AC Note: Measurements taken with 12.8V DC or 120V AC power supply. Black Red ART01944 Brown ART01946 Figure 1. Temperature Control Figure 2. Fuse Locations NOTE: If 10 Amp fuse is blown, check the vehicle's wiring. Refrigerator Service Manual DC0040(K), DC0051(K), DE0040, DE0051, DE0240T, DE0251T, 3

Troubleshooting - Procedure B Resistance Resistance Measure Resistance. See Figure 3. 0 Internal Failure Change Cooling Unit ART01947 1.4 3.5 Normal Note: Perform procedure at room temperature. See Procedure C Measuring the Resistance 1. Turn the temperature control to the "Off" position. 2. Remove the black wire to the compressor. 3. Measure the resistance of the compressor between point A and point B. Refer to Figure 3. B A ART01958 Figure 3. Measuring Resistance 4 DC0040(K), DC0051(K), DE0040, DE0051, DE0240T, DE0251T, Refrigerator Service Manual

Troubleshooting - Procedure C Output Voltage Output Voltage DC OPERATION Less than 15V AC AC OPERATION Check AC Power Supply. (37-45V DC) (See Figure 5) GOOD BAD Measure Voltage Between A & B At the (See Figure 4) 0V AC Go to Procedure E Change Thermistor FAULTY THERMISTOR GOOD THERMISTOR Power Source AC Check AC Power Supply. (37-45V DC) (See Figure 5) DC GOOD BAD ART01948 15-25V AC Note: Measurements taken with 12.8V DC or 120V AC power supply. Normal See Procedure D A B ART01949 ART01950 Figure 4. Measuring Output Voltage Figure 5. Measuring AC Output Refrigerator Service Manual DC0040(K), DC0051(K), DE0040, DE0051, DE0240T, DE0251T, 5

Troubleshooting- Procedure D Measuring Amp Draw Amp Draw 40Watt < 1.6Amps 60Watt < 2.7Amps Failure Change Cooling Unit Measure Amperage at A on the (See Figure 6) 40Watt = 1.6 2.0Amps 60Watt = 2.7 3.3Amps Normal ART01952 40Watt > 2.0Amps 60Watt > 3.3Amps Note: Measurements taken with 12.8V DC power supply. Failure Change Cooling Unit A ART01953 Figure 6. Measuring Amp Draw 6 DC0040(K), DC0051(K), DE0040, DE0051, DE0240T, DE0251T, Refrigerator Service Manual

Troubleshooting - Procedure E Verifying Thermistor Operation To measure the resistance of the evaporator thermistor, complete the following procedure. 1. Turn the temperature control to the "Off" position. 2. Disconnect the 3-pole connector. Refer to Figure 7. 3. Measure the resistance across the two pins. Refer to Figure 8. 4. Check the evaporator thermistor by measuring the temperature and resistance of the thermistor. NOTE: In general, 1.6K - 29KΩ = good thermistor. Ω = defective thermistor. An open thermistor will stop normal compressor operation. Replace the defective thermistor. ART01955 Refer to Table 1 for a listing of acceptable resistance ranges. ART01954 Figure 8. Measure Resistance Across Pins Figure 7. Evaporator Thermistor Connection (Inside ) Evaporator Thermistor Resistance Thermistor Temperature ( F) ( C) Resistance Allowable Resistance Range 0-18 9.7 KΩ 8.7-10.7 KΩ 10-12 7.8 KΩ 7.0-8.6 KΩ 20-7 6.4 KΩ 5.7-7.0 KΩ 30-1 5.3 KΩ 4.8-5.7 KΩ 40 4 4.5 KΩ 4.0-4.9 KΩ 50 10 3.6 KΩ 3.2-4.0 KΩ 60 16 2.8 KΩ 2.5-3.1 KΩ 70 21 2.1 KΩ 1.9-2.3 KΩ 80 27 1.9 KΩ 1.7-2.0 KΩ 90 32 1.8 KΩ 1.6-1.9 KΩ Table 1. Evaporator Thermistor Resistance Refrigerator Service Manual DC0040(K), DC0051(K), DE0040, DE0051, DE0240T, DE0251T, 7

Troubleshooting - Procedure F Insufficient Cooling NOTE: Check input voltage before proceeding. Refer to Procedure A. If the compressor runs continuously, do the following:! Check the voltage across the fan leads. There will be a slight voltage reading even if the fan isn't operational. The fan will only operate when the compressor is running, and the ambient temperature is sufficient to engage the fan. The operational voltage of the fan is between 17 and 22VDC. If this is present at the leads and the fan is not running, replace the fan. CAUTION: When servicing the fan, do not short the wires. Shorting the wires will damage the power supply. Make sure that the ventilation vents are not blocked. Refer to Procedure I. Make sure that the auto shut-off device is operational. Refer to Procedure H. If the reason for insufficient cooling is not found, start with Procedure B. Replace the cooling unit if: The compressor is hot to the touch and not vibrating. The compressor vibrates but there is no cooling. Troubleshooting - Procedure G Refrigerator is Too Cold If the refrigerator is too cold, do the following: Adjust the temperature control to a lower setting. Number 1 is the warmest setting; number 5 is the coldest. Make sure that the thermistor is securely mounted to the evaporator plate. If you cannot determine a cause, refer to Procedure E. Troubleshooting - Procedure H Auto Shut-Off Device NOTE: Only the 12/24V DC and DE/Truck models are equipped with the auto shut-off device within the power supply. Operating the Shut-Off Device To protect the cooling unit from overheating, the refrigerator will automatically shut-off when the ambient air temperature is approximately 110 F (43 C). If shut-off occurs, the refrigerator will sound an intermittent alarm tone. To stop the alarm, the refrigerator must be restarted using the following procedure: 1. 2. Turn the temperature control counterclockwise to the "Off" position. Turn the temperature control to the desired setting. NOTE: The refrigerator will not restart until the ambient conditions allow for normal operation. NOTE: To test the shut-off device's functionality, heat the device with a heat gun. Refer to Figure 9. ART01956 Figure 9. High Temperature Shut-off Device 8 DC0040(K), DC0051(K), DE0040, DE0051, DE0240T, DE0251T, Refrigerator Service Manual

Troubleshooting - Procedure I Proper Ventilation Ventilation is necessary for the correct operation of the refrigerator. Good ventilation also increases the life of the refrigerator's cooling system. The current models are equipped with built-in ventilation systems that draw cooler air through the lower intake vent. This air is then circulated over the cooling unit to remove excess heat from the cooling system. The heated air is then rejected through the upper vent. If this airflow is blocked or decreased, the refrigerator will not cool correctly. Reducing the vent area can cause the following: Shortened life of the refrigeration-cooling unit. Poor cooling performance of the refrigerator. Continuous operation of the refrigerator. Fast battery discharge. Voiding the refrigerator warranty.! CAUTION: Do not block the vents by closet or cabinet doors. Wiring Schematic FAN MOTOR 24V DC ORANGE AC IN(L) ~ WHITE B3P-VH AC IN(N) AC 85~132V + AC/DC converter - AC/DC PART DC OUT + RED DC OUT - BLACK DC INPUT CN1 B2P-VH RED BLACK XHP-2 B2B-XH-A BATTERY IN + DC 12~32V RED BLACK BATTERY IN - FUSE FUSE BATTERY MONITOR (OPTIONAL) DC/DC converter INPUT HIGH VOLTAGE PROTECTOR DC 39V FOR 40W DC 41V FOR 60W INVERTER + CONDENSOR COUPLING CN2 B3P-VH VHR-3N SK515-N HIGH TEMPERATURE ELECTRONIC PROTECTER THERMOSTAT BUZZER (OPTIONAL) LOW TEMPERATURE PROTECTER AMBIENT ELECTRONIC CURRENT THERMISTOR PROTECTOR ART01957 CN4 B2B-EH EHR-2 BLACK AMBIENT THERMISTOR BLACK DC/AC PART EVAPORATOR THERMISTOR Refrigerator Service Manual DC0040(K), DC0051(K), DE0040, DE0051, DE0240T, DE0251T, 9

Troubleshooting - Quick Reference Quick Reference Troubleshooting Steps 1. 2. 3. 4. 5. Check for supply voltage at the rear of the refrigerator. Turn the temperature control to the "On" position. The operating voltage should be between 10.5V and 32V DC. There will be some variation in these readings depending on the supply voltage. Check the compressor voltage between points A and B. Voltage should be between 15V - 25V AC. Refer to Figure 10. If voltage is not within range, refer to Procedure C. With the refrigerator power on, take an Ohm reading (1.4-3.5Ω) at the compressor between points A and B. Refer to Figure 11. If the Ohm reading is not within range, refer to Procedure B. With the refrigerator power off, and the lead removed from point "A", take an Amp reading (1.6-3.3 Amps) at the black wire with the rubber boot. Refer to Figure 12. If amperage is not within range, refer to Procedure D. ART01958 B A Figure 11. Taking an Ohm Reading A B A ART01949 ART01953 Figure 10. Checking Voltage Figure 12. Measuring the Amp Draw 10 DC0040(K), DC0051(K), DE0040, DE0051, DE0240T, DE0251T, Refrigerator Service Manual

This Page Intentionally Left Blank.

NORCOLD, Inc. P. O. Box 4248 Sidney, OH 45365 NORCOLD, Inc. Customer Support Dept. Telephone: 800-543-1219 Fax: 937-497-3183 www.norcold.com DCXXXX, DEXXXX Refrigerator Service Manual Part No 631842A (08-08-07)