Service Parts for RMR Wall-Mount Enclosures

Similar documents
SPECTRACOOL Indoor & Outdoor Air Conditioners

Thermal management of electrical enclosures. Stronger than the elements. Pfannenberg units for outdoor thermal management.

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners

Top-Mount Air Conditioners

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

Thermal Management and Signaling Technology

RMR Fixed Wall-Mount Enclosure

PROAIR Harsh Environment/Wash Down Air Conditioners

SPECTRACOOL INDOOR/OUTDOOR

SPECTRACOOL Indoor & Outdoor Air Conditioners

revolutionary new way to cool your electrical enclosures

5736 N. Michigan Road Indianapolis, IN 46228

5736 N. Michigan Road Indianapolis, IN 46228

GENESIS Indoor Air Conditioners

N Volt 1800 BTU/Hr. 527 Watt

N Volt 1800 BTU/Hr. 527 Watt

G /6000 BTU/Hr. 1172/1758 Watt

G /6000 BTU/Hr. 1172/1758 Watt

AIR TO AIR HEAT EXCHANGERS

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes

VA G 052 S

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

T-Series Air Conditioner T20 Model

Thermal Management INDEX. Management. Thermal TM-1

Everyone talks about the future, but Rittal helps shape it and that includes. Modern cooling units with excellent efficiency and perfect interface

T-Series Air Conditioner T53 Model

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic

Quality Enclosures. Service Excellence.

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

Construction. Electrical. Enclosure Protection IS19 - Industry Standards UL Recognized Type 3, 3R, 4 & 12 IEC IP56

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

ENCLOSURE COOLING. Glossary

CHAPTER12. Thermal Management. Featured Products in this Chapter. Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P.

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Installation and Operation Guide For

Direct Gas-Fired Make-Up Air Models DG and DGX

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

NQ Series Portable Chillers

Thermal Management and Signaling Technology

Guardian/GuardianX Series NEMA 4 or 4X Rated Air Conditioners. Air Conditioners:

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

Evaporator EM-1. Features. V.1. Ceiling Mount Evaporators

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ USA Phone: web:

T-Series Air Conditioner T15 Model

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

MultiPlex INNOVATIVE COMPRESSED AIR SOLUTIONS LARGE CAPACITY TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS

Installation and Operation Guide For MCF-49FD, MCF-23FD MCR-49FD, MCR-23FD

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers

Executive Summary 4G WiMax Radio Access Cabinet

KNHX32 SERIES NEMA 4/4X AIR-TO-AIR HEAT EXCHANGERS

GRF Series Non-Cycling Refrigeration Dryers ANDARD ELECTRONIC DRAIN STANDARD ELEC SS EXPANSION VALVE F PRESSURE DEWPOINT

FIGURE 1 Forced Convection Method. Filter & Grille Required. Ambient Air. Filter & Grille Required

PerfectCool Bottom Mount Refrigerator KFNS ide

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

next p dw next p dw rcgroupairconditioning

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

Central Chillers TS Series

Roof Top Packaged Unit (RTU-1) Specification

RACK-MOUNT Air Conditioners

Featured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

Quality Products. Service Excellence.

AIR CONDITIONER OPERATOR'S MANUAL

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES K2NA6C14DP50L

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner K2A3C8P36LFHN-1

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner NPT SERIES K_A6C_NPT47L

CHILLER. Operator s & Installation Manual

COOLflow 4E PRODUCT RANGE

The ultimate fresh air solution.

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Environmental Specifications for Kaleidescape Components Engineering Bulletin

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner DP SERIES K2A3C14DP50L

Refrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner ADVANTAGE RP55 SERIES

Transcription:

Door Kits for RMR Wall-Mount Enclosures Replacement doors for RMR Wall-Mount Enclosures are removable and can be easily replaced if a door is damaged. Order latch separately. Several options are available: Solid Metal Door Metal Door with Window Single Tempered Glass Door for RMR Wall-Mount Enclosures 23.6 (600) 27.6 (700) Enclosure Height U 37060-X01 37060-X31 19.1 (486) 9 19 (8.7) 37060-X02 37060-X32 20.9 (530) 10 20 (9.1) 37060-X03 37060-X33 22.6 (575) 11 22 (10.0) 37060-X04 37060-X34 24.4 (619) 12 23 (10.5) 37060-X05 37060-X35 26.1 (664) 13 24 (10.9) 37060-X06 37060-X36 27.9 (708) 14 25 (11.4) 37060-X07 37060-X37 29.7 (753) 15 26 (11.8) 37060-X08 37060-X38 31.4 (797) 16 27 (12.3) 37060-X09 37060-X39 33.1 (841) 17 29 (13.2) 37060-X10 37060-X40 34.9 (886) 18 30 (13.7) 37060-X11 37060-X41 36.6 (930) 19 31 (14.1) 37060-X12 37060-X42 38.4 (975) 20 32 (14.6) 37060-X13 37060-X43 40.1 (1019) 21 33 (15.0) 37060-X14 37060-X44 41.9 (1064) 22 34 (15.5) 37060-X15 37060-X45 43.6 (1108) 23 36 (16.4) 37060-X16 37060-X46 45.4 (1153) 24 37 (16.8) 37060-X17 37060-X47 47.1 (1197) 25 38 (17.3) 37060-X18 37060-X48 48.9 (1241) 26 39 (17.7) X= Color; C=Black, G= Hammer Gray. weights are for 27.6 in (700 mm) wide models. For more information on RMR Industrial Enclosures, visit www./industrial-enclosures.co.cn

Door Kits for RMR Wall-Mount Enclosures Replacement doors for RMR Wall-Mount Enclosures are removable and can be easily replaced if a door is damaged. Order latch separately. Several options are available: Solid Metal Door Metal Door with Window Single Solid Metal Door for RMR Wall-Mount Enclosures 23.6 (600) 27.6 (700) Enclosure Height U 37070-X01 37070-X31 19.1 (486) 9 15 (6.9) 37070-X02 37070-X32 20.9 (530) 10 16 (7.3) 37070-X03 37070-X33 22.6 (575) 11 17 (7.8) 37070-X04 37070-X34 24.4 (619) 12 17 (7.8) 37070-X05 37070-X35 26.1 (664) 13 18 (8.2) 37070-X06 37070-X36 27.9 (708) 14 19 (8.7) 37070-X07 37070-X37 29.7 (753) 15 20 (9.1) 37070-X08 37070-X38 31.4 (797) 16 22 (10) 37070-X09 37070-X39 33.1 (841) 17 23 (10.5) 37070-X10 37070-X40 34.9 (886) 18 24 (10.9) 37070-X11 37070-X41 36.6 (930) 19 24 (10.9) 37070-X12 37070-X42 38.4 (975) 20 25 (11.4) 37070-X13 37070-X43 40.1 (1019) 21 26 (11.8) 37070-X14 37070-X44 41.9 (1064) 22 27 (12.3) 37070-X15 37070-X45 43.6 (1108) 23 28 (12.8) 37070-X16 37070-X46 45.4 (1153) 24 29 (13.2) 37070-X17 37070-X47 47.1 (1197) 25 30 (13.7) 37070-X18 37070-X48 48.9 (1241) 26 31 (14.1) X= Color; C=Black, G= Hammer Gray. weights are for 27.6 in (700 mm) wide models. For more information on RMR Industrial Enclosures, visit www./industrial-enclosures.co.cn

Door Latch Kit for RMR Wall-Mount Enclosures Replacement Door Latch Kit for RMR Wall-Mount Enclosures. Order latch separately. Part Number Door Latch Kit for RMR Wall-Mount Enclosure Enclosure Depth 37043-001 20.0 (510) 2 (0.9) 37043-002 24.0 (610) 2 (0.9) 37043-003 29.9 (760) 2 (0.9) For more information on RMR Industrial Enclosures, visit www./industrial-enclosures.co.cn

Filter Fans Replacement Filter Fans for wall-mount enclosures. Use Filter Fans in nonhazardous environments with outside temperature range that is lower than the temperature required in the enclosure. Side-mounting Supports side-to-side airflow Easy, tool-less installation Maintains NEMA Type 12 protection ratings Hinged grill for easy filter replacement Optimized airflow and reduced energy consumption Fluted filter mat allows 300% longer service time Standard size is: Side mounted, 38 CFM (65 CMH) unimpeded airflow, 115V, with filter for 6" x 6" (153 mm x 153 mm) cutout Consult Thermal Management Accessories for RMR Enclosure Systems data sheet for more detailed specifications. RMR Thermal Accessories Cutout Size Airflow Fan Configuration Intake Exhaust CFM (CMH) Voltage Color 37101-001 37101-002 6 (153) 38 (65) 115 Hammer Gray 5 (2.3) 37101-003 37101-004 6 (153) 38 (65) 230 Hammer Gray 5 (2.3) 37101-005 37101-006 6 (153) 38 (65) 115 Black 5 (2.3) 37101-007 37101-008 6 (153) 38 (65) 230 Black 5 (2.3) RMR Enclosure Power Cord for Filer Fan Voltage Cord Type 37902-001 125 NEMA 5-15P 2 (0.9) 37902-002 250 NEMA 6-15P 2 (0.9) 37902-003 250 IEC C14 2 (0.9) Color is Black. RMR Wall-Mount Enclosure Filter Kit Filter Cutout 37102-00X 6 (153) 4 (1.9) X= Color; C=Black, G= Hammer Gray. For more information on RMR Industrial Enclosures, visit www./industrial-enclosures.co.cn

Cooling Unit by Pfannenberg for RMR Wall-Mount Enclosure Systems Replacement cooling unit for RMR Wall-Mount Enclosures. Closed-loop cooling is required when the ambient temperature is greater than the target internal temperature of the enclosure, or when higher ingress protection (NEMA Type 12 rating) is necessary. Side-mounting Able to perform efficiently in high temperature areas Uses environmentally friendly HFC-free R134a refrigerant Backward curve impeller fan optimizes airflow and extends service life Condenser coils are coated with corrosion protection to extend service life Wide condenser fin spacing reduces particulate clogging while balancing performance Hermetically sealed compressors prevent refrigerant loss Condensate drain port to remove moisture Closed-Loop Cooling isolates the external ambient air from the internally conditioned air, eliminating the risk of contaminants entering the enclosure Standard size is: - Side mounted, 900-1,300 Btu/hr (263-381 W), 115V RMR Wall-Mount Enclosure Indoor NEMA Type 12 Cooling Units (900-1300 Btu/hr (263-381 W) Capacity Voltage Color 37103-001 115 Hammer Gray 35 (15.9) 37103-002 230 Hammer Gray 35 (15.9) 37103-003 115 Black 35 (15.9) 37103-004 230 Black 35 (15.9) Gland Plates for RMR Wall-Mount Enclosure Systems Replacement gland plates feature allows pre-existing wiring or equipment to be installed in the cabinet. RMR Wall-Mount Enclosure Gland Plates in (m) 37080-X01 23.7 (600) 6 (2.8) 37080-X02 24.7 (625) 7 (3.2) 37080-X03 25.6 (650) 7 (3.2) 37080-X04 26.6 (675) 7 (3.2) 37080-X05 27.6 (700) 7 (3.2) X= Color; C=Black, G= Hammer Gray. For more information on RMR Industrial Enclosures, visit www./industrial-enclosures.co.cn