Automatic Infrared Tap TAPIFR. Instruction Manual

Similar documents
Handyflow Undersink HF05MVC

Zen Boiling Tap Range

TH01B, TH02B, TH03B, TH04B

HS&S Alert No: 103 Date: 9 March 2017

Product Instruction Manual. Jetstream JET1600 (white) & JET1600BSS (brushed stainless steel) 1.6 kw automatic hand dryer V15.

SC2000Y, SC2000YST, SC2000YM

Speedflow Undersink Unvented Water Heater. Models SF05K, SF10K and SF15K. Instruction Manual

Powerflow Unvented water heater

AC500T, AC1000T, AC1500T, AC2000T

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

ascent Installation & maintenance instructions Customer/technical services Guarantee Mono basin filler with infrared sensor GUARANTEE REGISTRATION

Infra Red Basin Tap IR120CP.1 & IR121CP.1

Eco IR Basin Tap. Installation and Maintenance Guide. A basin mounted tap with pre-programmed infra-red sensor; mains or battery supply.

Installation & Operating Instructions

Single Lever Pull out Kitchen Tap

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

Installation Manual SEIHTP1, SEIHTM1. Issue SEIHTM1 Model Shown STROM- LIMITED.

INSTALLATION MANUAL Wolfen Hob Mounted Sensor Tap with Internal Solenoid. Installation Details Warranty

POWER SHOWERS Models 4500M 5002M 4500T 5002T

Beautifully Traditional

HEAVY DUTY BRASS SHOWER PUMPS

INSTANTANEOUS ELECTRIC SHOWER

PARTS WASHER Model: CW2D Part No:

Beautifully Traditional

X62 Tap Range. Please keep these instructions for future reference

SEIH7KTS1,SEIH9KTS1 SEIH11KTS1. Installation Manual. Issue STROM- ELECTRICAL.

PARTS WASHER Model: CW1D Part No:

SHOWER WATER HEATER MODEL X-SLIM 35 EC / X-SLIM 45 EC OPERATION AND INSTALLATION INSTRUCTIONS

Monza Easyfit Kitchen Sink Mixer

INSTRUCTION MANUAL Model: SU3022

TH100 Three in One Instant Hot Water Tap

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

PREMIUM KITCHEN MIXER TAP. PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

Aqua & Instantaneous Electric Shower Installation Instructions SERVICE POLICY

Beautifully Traditional

Installation Instructions Flute Tap Range

MW401 Integrated Dishwasher

MW402 Integrated Dishwasher

SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar

Manual for installation, use and maintenance MW200. Integrated Slimline Dishwasher. year. parts + 1 year labour guarantee.

Refresh & Clean Carpet Washer

Blueberry Kitchen Sink Tap

Cinnamon Kitchen Sink Tap

Beautifully Traditional

Your GardenMate Easy Dial Automatic Tap Timer

OPERATING & MAINTENANCE INSTRUCTIONS

Zip Chilltap Extra. Affix Model Number Label Here UK. Installation and Operating Instructions

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

MODEL NO: CW2D PART NO: OPERATING & MAINTENANCE INSTRUCTIONS

Self-help Temperature Adjustment

Installation guide Nordic mixer taps. Before installing read this guide first

EDEN. Installation Instructions. Bath shower manual mixer tap INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Single Lever Pull Out Kitchen Faucet

USER MANUAL. 80 cm 2 burners, glass hob AKC 820C/BLM

UBGHFF60W 60cm Gas on Glass Gas Hob

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Electronic Instantaneous Water Heaters Models: ES3, ES4 & ES6

Trouble Shooting and Help Guide TT / TTB 1840

ART cm Island Curved Glass

Nachi Series TM Z6957-XL

Thermostatic bar mixer valve with adjustable head Installation guide

EXPOSED BATH SHOWER MIXER INSTRUCTION MANUAL W INST 300. Please note: Tap heads shown is for illustration purposes only.

NON-SUBMERSIBLE WATER PUMP

Operating and assembly manual: Electric instantaneous flow heater Admiral

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

WF140 Freestanding Dishwasher

USER MANUAL. 60cm, 3 burners, Hob AKC 630

Thermostatic Bar Valves

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

WC370 Integrated Intelligent dishwasher Manual for Installation, Use and Maintenance

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

MIDAS. Installation instructions 110/220

WC600 Integrated Dishwasher Installation, Use and Maintenance

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

900 Quadrant Steam Shower Cabin with 6 Body Jets

Infra Red Thermostatic Wall Mixer

UB110DNC/L/U/B BASIN MONOBLOC WITH NO POP-UP WASTE BASIN MONOBLOC TALL WITH NO POP-UP WASTE UB112DNC/L/U/B INSTALLATION INSTRUCTIONS

IN00333 (rev C) Quadrant Shower Cabin with Monsoon Head

Turboboost SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar

ISCG90SS _03 ISCG90SS

USER INSTRUCTION MANUAL. Autofill Water Boiler

wc431 Slimline Integrated Dishwasher Manual for Installation, Use and Maintenance

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill

MHG201 Gas Hob Manual for Installation, Use and Maintenance

Installation, Operating and Servicing Instructions

REVE ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS 现代型分体座便器 CONTEMPORARY TWO-PIECE TOILET K-17178T-S/K-17178T-SP

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

Pegler Yorkshire reserve the right to change specifications. 10 Year Guarantee Luxury Taps and Mixers

PERFORMANCE SHOWER PRODUCTS

SP-RANGE INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR SP12 & SP25 SERIES 4

OPEN OUTLET TAPSETS. Fitting Instructions and User Guide

Mix Boiler & Font Range ( #, #, #, , )

Franke Specialist Range Pilatus Tap

WC2 & WC3 Installation & Maintenance Instructions

ZIP InLine. Models: ES3, ES4 & ES6. Electronic Instantaneous Water Heaters. ES3, ES4 & ES6 Instructions. V1.09 Page 1 November / 2015

Transcription:

Automatic Infrared Tap TAPIFR Instruction Manual Version 1.0 Jan 015

PLEASE READ THESE INSTRUCTIONS BEFORE COMMENCING INSTALLATION. UPON COMPLETION OF INSTALLATION ENSURE THE INSTRUCTIONS ARE LEFT WITH THE USER/MAINTAINER OF THE PRODUCT. Automatic Infrared Tap 1. INTRODUCTION Thank you for purchasing the Hyco Infrared TAPIFR. The automatic Infrared tap can be connected to mains power supply or can be battery operated. Ideal for use with the Hyco Rho and Aquila Instantaneous water heaters, the tap is supplied with a standard aerator. If the tap is to be used with an instantaneous water heater there is also a choice of 3 tap spray nozzles -.0,.5 or 3.0 litres/min.. IMPORTANT SAFETY POINTS INSTALLATION SHOULD BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON. IF THE TAP IS TO BE CONNECTED TO MAINS POWER SUPPLY THEN INSTALLATION SHOULD BE CARRIED OUT IN ACCORDANCE WITH THE LATEST EDITION OF THE IEE WIRING REGULATIONS. ENSURE MAINS WATER SUPPLY FEEDS ARE ISOLATED BEFORE REMOVING ANY EXISTING TAP AND YOU BEGIN THE INFRARED TAP INSTALLATION PROCESS. ENSURE THAT THE WATER PRESSURE IS WITHIN THE REQUIRED RANGE AS STATED IN THE TECHNICAL SPECIFICATION SECTION. DO NOT INSTALL TOO CLOSE TO REFLECTIVE SURFACES AS THE INFRARED SENSOR MAY BE AFFECTED.

Parts list 1 Aerator 8 Transformer Sensor 9 Fixing screw 3 Tap main body 10 Power Cable 4 Rubber washer 11 Fixing nut 5 Brass washer 1 Battery holder 6 Flexible hose (Cold) 13 Battery holder mounting plate 7 Flexible hose (Hot) 14 Battery holder lid 1 8 3 4 5 6 9 10 11 7 1 13 14 140mm 60mm 50mm 3

3. INSTALLATION ALL SUPPLY PIPEWORK SHOULD BE THOROUGHLY FLUSHED BEFORE CONNECTING TO THE TAP, THIS IS TO REMOVE ANY DEBRIS. Fig 1 Before fitting to the sink, connect the flexible hoses (1) supplied to the connections at the base of the tap and tighten firmly. The hot and cold connections are marked with the letters H and C. Feed the flexible hoses and power cable through the hole in the sink or worktop and secure the tap in place using the shaped rubber and brass washers () and tightening the fixing nut (3). 1 1 3 Fig Connect the flexible hoses to the Hot and Cold mains water feed and check for leaks before isolating the supply. OFF ON Fig 3 & 4 (Battery operation) Remove the battery holder lid and fit 4 AA Alkaline batteries ensuring that they are fitted in the correct orientation. This can now be connected directly to the tap power cable at the base of the tap. 3 1 4 4 Fig 5 If you choose to power the tap with a mains power supply, ensure that the supply voltage is correct and is wired as follows: Live - Brown Wire Neutral - Blue Wire Connect the tap power cable to the battery holder / transformer. 5 Transformer output Sensor connector Battery box connector

Fig 6 Fix the battery holder mounting plate to the wall securely as shown using the fixings provided. 6 7 Fig 7 Slide the battery holder onto the mounting plate to secure in place. Fig 8 Turn on the hot and cold mains supply. 8 HOT Turn on Turn on COLD Use with Instantaneous water heaters The tap is supplied with a standard aerator but for use with instantaneous water heaters a tap spray nozzle is recommended (3 options supplied). Turn on mains water supply. Remove the aerator and flush through by opening the tap. Select the correct tap spray nozzle using the table below and fit into the tap. Tap spray nozzle Max flowrate Best Suited to Colour code (litres/min) water heater identification IN-TSN-.0.0 4.4kW Rho White/Black IN-TSN-.5.5 6.0kW Rho White/Green IN-TSN-3.0 3.0 9.6kW Aquila White/Lilac 5

4. OPERATION To operate, place your hands under the tap to activate the sensor. The flow will stop when you remove your hands. It will automatically stop after 30 seconds of continuous flow. Wait 3 seconds before next use. 5. CARE AND MAINTAINANCE Keep the surface of the Infrared tap clean and dry. Clean with a damp cloth only - Do not use abrasives. Changing batteries If using battery operation, the batteries (4 x AA Alkaline) can be replaced by removing the battery holder lid. A small pozi-screwdriver is required to remove the lid. 6. TECHNICAL SPECIFICATION MODEL NO POWER INPUT SENSOR DETECTION ZONE WATER PRESSURE POWER CONSUMPTION INLET / OUTLET DIAMETER WATER TEMPERATURE REACTION TIME TAPIFR DC:6V (4X1.5V AA Alkaline battery) AC:0-40V (50/60Hz) 10-35cm 0.05-0.7Mpa AC: <0.5mw; DC: <0.3mw G1/ 1-50 C <1 Second 6

7.TECHNICAL SHOOTING SYMPTOM POSSIBLE CAUSE SOLUTION No water flowing from the tap Batteries require Change the batteries replacing No mains water supply Check water supply Water pressure too low Increase water Pressure Dirt in the filter Clean filter Water will not turn off IR Sensor dirty Clean IR sensor with a damp cloth Flowrate too low Reduced flowrate Increase flowrate Blocked filter Clean filter Water pressure too low Increase water pressure Flowrate too high Water pressure too high Reduce water pressure Short battery life Incorrect batteries fitted Change to 4AA Alkaline batteries The Indicator light is not on The light is broken Change the light or circuit board The circuit board is wet Dry out The batteries have expired Change the battery Poor battery connection Check battery connections 8. GUARANTEE AND SERVICE POLICY This product is guaranteed against faulty materials and manufacture for a period of one year from the date of purchase. Hyco will in its sole discretion replace, repair or refund any faulty unit. Incorrect installation, frost damage, and the consequences of limescale deposits are excluded. Consequential costs such as labour charges or damage to fittings and surroundings are expressly excluded. 7

INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH THE EUROPEAN DIRECTIVE 00/96/E. At the end of its working life this equipment must not be disposed of as household waste. It must be taken to a local authority waste collection centre or to a dealer providing this service. Disposing of electrical and electronic equipment separately enables its components to be recovered and recycled to obtain significant savings in energy and resources. In order to underline the duty to dispose of this equipment separately, the product is marked with a crossed out dustbin. Hyco Manufacturing Ltd Normandy Court, Express Way Castleford, WF10 5NR Sales: 0194 5 00 Fax: 0194 5 10 Switchboard: 0194 5 15 Email: sales@hyco.co.uk www.hyco.co.uk WATER HEATING SPACE HEATING HAND DRYERS