To register your fixture, please visit our website: MonteCarloFans.com NEED HELP? NECESITA AYUDA? AVEZ-VOUS BESOIN D AIDE?

Similar documents
To register your fixture, please visit our website: MonteCarloFans.com NEED HELP? NECESITA AYUDA? AVEZ-VOUS BESOIN D AIDE?

Ceiling Fan Installation Instructions

Ceiling Fan Installation Instructions

Owner s Guide and Installation Manual

5SLR52XXD-B Series Fan UL Model No. : 5SLR52. Owner s Guide and Installation Manual

Ceiling Fan Installation Instructions

Ceiling Fan Installation Instructions

Ceiling Fan Installation Instructions

Ceiling Fan Installation Instructions

Owner s Manual Ceiling Fan Installation Instructions

5DI52XXD/5DI52XXD-L Series Fan UL Model No. : 5DI52. Owner s Guide and Installation Manual

5CO52XX Series Fan UL Model No. : 5CO52. Owner s Guide and Installation Manual. Attach sales receipt to this card and retain as your proof of purchase

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

5WF42XX Series Fan UL Model No. : AC-542OD. Owner s Guide and Installation Manual

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

5GFR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5GFR52XXD

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

8TNR56XXXD-V1 Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 8TNR56XXXD-V1

5YK60XXX Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 5YK60XXX

3VNR52/42XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3VNR52XXD / 3VNR42XXD

Ceiling Fan Installation Instructions

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

5AZR56XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5AZR56XX

3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

CELEBRITY DELUXE 52" indoor fans

LONG BEACH 52" outdoor fans

5LCM52XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : AC-552AL

3SKYR56XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 3SKYR56(XXXXX)

3CLMR56XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3CLMR56XXD

3AVOR56XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 3AVOR56XXXXX

14PRR62XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 14PRR62(X)

LIMITED LIFETIME WARRANTY

FOR AMD SAVE THESE INSTRUCTIONS OWNER'S INSTRUCTION MANUAL CAUTION. Intertek. Note: Approximate time of assembly is 30 min to 1 hour.

LIMITED LIFETIME WARRANTY

Gunnar Ceiling Fan. model no OWNER S MANUAL

LIMITED LIFETIME WARRANTY

Hanson LED C e i l i n g F a n

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

LIMITED LIFETIME WARRANTY

CEILING FAN OWNER'S MANUAL

54" Skye. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

52 SAN LUCAS CEILING FAN

CircoloTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

LIMITED LIFETIME WARRANTY

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

Sunburst. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

Highland ManorTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

CEILING FAN OWNER'S MANUAL

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

#ADENCE4- $ESIGNED )NCLUDES #OOL4OUCH4- +ICHLER )NSTRUCTION #USTOMER KHA

KimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

52 BARSTOW CEILING FAN

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

52 BERKSHIRE CEILING FAN

52 STRATHMERE CEILING FAN

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

READ AND SAVE THESE INSTRUCTIONS

CEILING FAN OWNER S MANUAL

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

CEILING FAN OWNER'S MANUAL

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

52 CEILING FAN. Owner s Manual Models #50336, 50337

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

CEILING FAN OWNER'S MANUAL

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

Innes. Instruction Manual A Kichler Decor ceiling fan. Includes our new TM

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

LED. 60 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

CEILING FAN OWNER'S MANUAL

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

CEILING FAN OWNER'S MANUAL

48 TAYLOR CEILING FAN

62" LED SPYRA. Product images may vary slightly from actual product. INSTRUCTION MANUAL

MACBAY CEILING FAN. welcoming sophisticated inspiring ITEM # MODEL #L1405 Español p. 19 ATTACH YOUR RECEIPT HERE

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Torrena 42 Ceiling Fan

CEILING FAN OWNER S MANUAL

Camarillo 52 Ceiling Fan

FerronTM. Instruction Manual A Kichler Decor ceiling fan

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

30-YEAR LIMITED WARRANTY

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

LaceyTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

Table of Contents. What to Expect with. Mounting Options. Tools Needed

52 BAYTOWNE CEILING FAN

Essex 42 Ceiling Fan TOOLS AND MATERIALS REQUIRED Mounting options : Hugger & Drop mount

Table of Contents What to Expect with. Mounting Options. Tools Needed. Downrod. Blades

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

Transcription:

5MFR52XXD Series Fan UL Model No. : M52-5B/3L R MonteCarloFans.com shown with MFSCROLLRB To register your fixture, please visit our website: MonteCarloFans.com STOP NEED HELP? NECESITA AYUDA? AVEZ-VOUS BESOIN D AIDE? Please do not return this product to the store. Por favor no devulva este producto a la tienda. Prière de ne pas retourner ce produit au magasin. ALTO If you need installation assistance, replacement parts, or have questions regarding our warranty, please call our customer care center: Si necesita asistencia en la instalación, piezas de repuesto, o tiene preguntas acerca de nuestra garantía, por favor llame a nuestro centro de servicio al cliente: 1-800-519-4092 MonteCarloFans.com Si vous avez besoin d'aide pour l'installation, des pièces de remplacement, ou si vous avez des questions concernant notre garantie, veuillez contacter notre service après-vente: Total fan weight with light kit READ AND SAVE THESE INSTRUCTIONS

Helpful Tools Safety instructions 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70-1999), including fire-rated construction. Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer. After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be turned upward and pushed carefully up into the outlet box. WARNING: Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade. WARNING: To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked acceptable for fan support and use mounting screws provided with the outlet box (Mounting must support at least 35 lbs.) WARNING: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades. Attach the mounting bracket using only the hardware supplied with the outlet box. WARNING: To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch. WARNING: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. UC7067RYL manufactured by Rhine Electronic Co., Ltd. WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application. Never place a switch where it can be reached from a tub or shower. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit s operation. Follow the heating equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. CAUTION: To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit. All set screws must be checked and tightened where necessary before installation. 1 2 3 Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Before installing this fan make sure the outlet box is properly installed to the house structure. To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support. (Mounting must support at least 35 lbs.) Use metal outlet box suitable for fan support and use only the screws provided with the outlet box (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a structural ceiling member ( a loose box will cause the fan to wobble). Remove the two outlet box screws provided with the box, aligning the holes of the mounting bracket with the holes of the outlet box. Re-install the 2 outlet box screws securely. 4 5 6 Loosen 2 screws on yoke to allow down rod to slip into yoke. Remove keeper pin and cross pin from downrod, and save for later use. Place canopy over downrod.

7 8 9 P l a c e y o k e c o v e r o v e r downrod as shown. 10 Thread the leadwires and safety cable through the downrod. 11 Insert downrod into the yoke on top of fan body. Align the hole in the downrod with the hole in the yoke. Insert cross pin through yoke and downrod until point appears on the other side. 12 Install keeper pin. Tighten the 2 set screws on the yoke, once the down rod is in place. M a k e s u r e t h e s t u d s protruding from the bottom of the Mounting bracket are installed with threads all the way through the bracket. 13 14 Safety cable installation 15 Remote transmitter dip switch Safety cable Lag screw Lag screw Hang assembled fan from the mounting bracket installed to ceiling in previous step. Make sure the fan is hanging straight. Rotate fan until the tab on the Mounting bracket engages the slot on the Downrod Ball. This must be done to prevent the fan body from rotating when the blades are in motion. Safety cable Washer Lock washer For Canadian installation and for USA fan and light kit combinations over 35 lbs, in both flush and downrod mode the safety cable must be installed into the house structure beams using the 3 lag screws,washers, and lock washers. provided. Make sure that when the safety cable is fully extended the leadwires are longer than the cable and no stress is placed on the leadwires. Remote receiver dip switch Set dip switches on the Remote Transmitter and Remote Receiver to the same settings. T h i s m u s t b e d o n e s o t h e u n i t s w i l l communcate properly. If you have other fans you can set to control from one transmitter by setting both receivers the same as the transmitter. If you have more than one fan with remote. You can set the dip switches to different positiosns to have seperate control. 16 17 Grounded/ Green Black White Receiver Black White Blue 18 Install remote receiver into the mounting bracket. Make wiring connections as indicated above. White from fan to white from remote marked N. Blue from fan to blue from remote marked light. Black from fan to Black from remote marked L. White from house to white from remote marked AC N. Black from house to Black from remote marked AC L. Connect all green ground wires to Grounded wire from House. Make wire connections to power source using wire nuts provided. Make sure that no filiments are outside of the wirenut. After making the wire connections, the wires should be spread apart with the grounded conductor and the equipmentgrounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices after being made should be turned upward and pushed carefully up into the outlet box.

19 20 21 Lift Conopy allowing the 2 studs to protrude through the canopy and install knurled nuts as shown. Tighten the knurled nuts securely. The canopy should adjust for any irregularity in the ceiling or Outlet box. For fan without scene, go to step 22. For fan with scene, go to step 28. Insert blade into the slot on flywheel and install blade screws and fiber washers aligning each of the holes as shown (screws and washers provided). Tighten screws securely. Repeat this process for remaining blades. Note: Make sure the side with a label This side up is installed upward. 22 Connect white wire from fan to white wire from light fixture, then connect blue wire from fan to black wire from light fixture. L o o s e n t w o a n d r e m o v e o n e preassembled screw from the plate on motor assembly. Keep screw for later use. 23 Align keyhole slots of the light fixture with the screws on light pan and twist counterclockwise till tight. Re-nstall the screw which removed in step 21. Tighten all screws securely. 24 25 26 Install 3 x 40-watt G9 base bulbs. Bulbs included. WARNING: Over lamping the fan will result in the fan lights shutting down until the proper wattage of bulbs are installed.reset the lights by turning off, replace bulbs with the correct wattage bulbs, turn the power on. Note: Do not replace bulb until it cools down. Remove finial and then remove rubber washer and hex nut from light fixture. Save parts for later use. Attached glass onto light fixture and secure it by rubber washer and hex nut removed in step 25. 27 28 29 Install finial to secure the glass. Place scene over light fixture, aligning the holes with screw holes on light fixture as shown. Install 3 screws to secure the scene with light fixture. Screws provided.

30 31 32 Connect white wire from fan to white wire from light fixture and then connect blue wire from fan to black wire from light fixture. 33 Lift light fixture assembly up, aligning its keyhole slots with the screws on the plate and re-install the screw removed in step 21. Tighten all screws securely. 34 Install 3 x 40-watt G9 base bulbs. Bulbs included. WARNING: Over lamping the fan will result in the fan lights shutting down until the proper wattage of bulbs are installed.reset the lights by turning off, replace bulbs with the correct wattage bulbs, turn the power on. Note: Do not replace bulb until it cools down. 35 Remove finial and then remove rubber washer and hex nut from light fixture. Save parts for later use. Attached glass onto light fixture assembly and secure it by rubber washer and hex nut removed in step 33. Hang-tighten finial to secure the glass. 36 37 38 HAND HELD INSTALL Reverse feature of this fan is controlled by a switch located on top of the fan body. Turn off the fan, and reverse the fan by slipping the switch. This will reverse the direction of the fan blades. Remove battery cover. Install 12V battery into wall remote. Duracell MN21 / Eveready A23 / GP 23A all 12V.Attach cover of remote by placing over buttons and snap the battery cover in place. Place face plate over battery compartment and buttons. Place remote over 2 pins on front cover. Attach cover of remote by placing over 4 pins and snapping into place. 39 WALL MOUNT INSTALL Install wall control unit to outlet box using machine screws provided. 40 Attach front cover to wall control with screws provided. Snap battery cover in place. Note: If you want to add a scene on an installed fan (fan w/o scene), carefully remove the glass and light fixture from fan. Install scene with the light fixture as installation 28 and 29, then re-install the light fixture assembly and glass.

Remote Control Transmitter Features: MEDIUM SPEED LED LIGHT LOW SPEED HIGH SPEED F A N O F F S E T T I N G (Turns fan off only) LIGHT ON/OFF SETTING A N D D I M M E R ( P r e s s a n d h o l d t o d i m l i g h t infinitively) FAN SPEED Depress l dot for low speed, 2 dots for medium or 3 dots for high. To turn fan off press square. LIGHT DIMMER To turn light on, press light dimmer once quickly. To turn off press once quickly while light is on. To dim light hold down button light dimmer. The light will cycle from bright to dim to bright until button is released. Light will maintain last setting if turned off.

Trouble Shooting If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty in installation, please call our Customer Service Center at the number printed on your parts list insert sheet. Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Trouble Suggested Remedy 1. If fan does not start: 2. If fan sounds noisy: 3. If fan wobbles: 1.Check main and branch circuit fuses or circuit breakers. 2.Check line wire connections to fan and switch wire connections in switch housing. CAUTION: Make sure main power is turned off. 3.If this fan uses manual forward/reverse switch, make sure the switch is pushed firmly either way. Fan will not operate when switch is in the middle. 4.If this fan uses remote controller, make sure dip switches are setting properly and make sure battery is effective. 1.Check to make sure all screws in motor housing are snug (not over tightened). 2.Check to make sure the screws which attach the fan blade holder to the motor are tight. 3.Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing. CAUTION: Make sure main power is turned off before entering switch housing. 4.Check to be sure light bulb is tight in socket and not touching the glass shade. 5.Some fan motors are sensitive to signals from Solid State variable speed controls. 6.Allow "break-in" period of 24 hours. Most noises associated with a new fan will disappear after this period. 1.If this is a downrod mount fan, make sure that the ridge of the canopy engages the notch in the downrod ball. 2.Make sure that canopy, mounting bracket or mounting plate are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist. 3.Check that all blades are screwed firmly into blade holders. 4.Check that all blade holders are tightened securely to motor. 5.Most fan wobble problems are caused when blade levels are unequal. Check this level by selecting a point on the ceiling above the tip of one of the blades. Measure this distance from blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade is positioned for measurement. Repeat for each blade. If all blade levels are not equal, you can adjust blade levels by the following procedure. To adjust a blade tip down, insert a washer (not supplied) between the blade and blade holder at the screw closest to the motor. To adjust a blade tip up, insert washer (not supplied) between the blade and blade holder at the two screws farthest from the motor. Reverse the position of the washer if blades mount from top of blade. 6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute the weight and possibly result in smoother operation. 4. If light does not work: 1.Check blue wire from fan to make sure it is connected to hot wire from house. 2.Check for loose or disconnected wires in fan switch housing. 3.Check for loose or disconnected wires in light kit. 4.Check for faulty light bulb and make sure bulb is tight in socket. 5.Remove light kit and check the plug connections if it is connected with plugs. 6.If this fan uses remote controller, make sure dip switches are setting properly and make sure battery is effective. CAUTION: Make sure main power is turned off before entering switch housing and/or canopy. WARNING: Over lamping the fan will result in the fan lights shutting down until the proper wattage of bulbs are installed. Reset the lights by turning off, replace bulbs with the correct wattage bulbs, Turn power on.

Aug.2010