Eco-$mart, Inc. (888) LIQUID-AIR 1 (L-A 1) OPERATIONS MANUAL

Similar documents
Instruction Manual. Please read this manual carefully before operating this unit.

CONTENTS I. INTRODUCTION II. SAFETY NOTES III. PRECAUTIONS IV. MAINTENANCE V. HOW DOES YOUR ATMOSPHERIC WATER GENERATOR WORK VI. TROUBLE SHOOTING IX

AW250M. Operator s Manual. Atmospheric Water Generator. Another Great Product of Air Water Corporation, USA. July 2008

THE ULTRA SERIES USER MANUAL

A few simple steps to ensure perfect water, every time.

A few simple steps to ensure perfect water, every time.

Model 30/30S Atmospheric Water Generator TABLE OF CONTENTS

WHYNTER Eco Pure Air Purifier

OWNERS' GUIDE PRECISION WATER SYSTEMS WATER DISTILLER. Water Systems FOR MODELS: PWS MANUFACTURED BY:

TPP440. owner s guide. air purifier with uv light. air purifier with uv light TP

Arctic EVAPORATIVE COOLER USER MANUAL

EVAPORATIVE AIR COOLER SERVICE MANUAL

ANTIBACTERIAL HAND VAC WITH UV LIGHT

PWC-500/1000/1010/1500

Gallery Electric Fireplaces

A few simple steps to ensure perfect water, every time.

ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

OWNE R S MA N UA L. Made in USA. September 2015

Model CWA200 Owner s Manual

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

OPERATION MANUAL. Model: IC702/703 Ice Maker

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

MODEL 7000 SUCTION UNIT

A few simple steps to ensure perfect water, every time.

SAFETY AND OPERATING MANUAL

CONTENTS 1 SAFETY INSTRUCTIONS.. 2 FEATURES AND OPERATION... 3 PARTS LIST AND INSTALLATION. 4 CONTROL PANEL AND SETTINGS...

VAVIE ALKALINE WATER DISPENSER USER MANUAL

INFRARED SAUNA ROOM. Thank You for purchasing Our American Made Product! Proudly Made in the USA! PRECISION THERAPY 4 PERSON SAUNA USER MANUAL

ANTIBACTERIAL HAND VAC

ULTRASONIC HUMIDIFIER

Model DAC12004RC. Please read this manual carefully before use and keep it for future reference.

LOCK H M L REPLACE SLEEPING ANTI-POLLEN IONIZER UV-LAMP. User Manual

Dehumidifier. Instruction Manual. Model DH-320/A

SERIES OWNER MANUAL DP1000(B) Please read this manual carefully prior to operating your Drinkpod. Retain for future reference.

Steam Iron Instruction Manual MODEL: SG Ginnys.com

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

PROF. RANGE COOKER MODEL: EPRC-A6456GE(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

SimplyClear Pressurized Filter Product Manual

User Manual Manual del usuario Guide d utilisation. Blueair 400 Series

IMPORTANT INSTRUCTIONS OPERATING MANUAL

AllClear G2 Series Pressurized Filters Product Manual

MeacoClean CA-HEPA 119x5 Air Purifier

CA3500, BA3500, CH3500 New Comfort

HEPA Air Purifier with Ion Flow Technology

ISTRUZIONI PER L USO. Climatizzatore CT300 - CT300H

AIR PURIFIER WITH GERMICIDAL UV LIGHT

IMPORTANT SAFETY INSTRUCTIONS

OWNER S MANUAL. 4 GALLON OUTPUT PER DAY COOL MOISTURE HUMIDIFIER Model HCM-2051 Series. * Output dependent on room temperature and humidity.

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

ODE20: 20 LITRE DEHUIMIDIFIER

QUICK START GUIDE 04 WARNING 05 PACK CONTENTS 05 TECHNICAL SPECIFICATIONS 05 ELECTRICAL REQUIREMENTS 05 WIRING DIAGRAM 07 INSTALLATION OPTIONS

PWC 1800 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model PWC P/N man Copyright 2011 Vertex Water Products

Dehumidifier Owner s Manual Read and save these instructions before use

CONGRATULATIONS ON CHOOSING THE WATERLOGIC 4 FIREWALL YOUR WATERLOGIC WATER DISPENSER

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

BRITA. Water Filter & Chiller II. Chilled water filter. Instruction Booklet WF6100

M650-38A-OAK ELECTRIC FIREPLACE HEATER NDF-65NB-1 INSTRUCTION MANUAL

USER MANUAL HD SERIES. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704 HD5.

Outdoor Beverage Center

Electric Hand dryer. Installation and operating manual

PRE INSTALLATION PROCEDURES

A few simple steps to ensure perfect water, every time.

WA A Aqua Sub Bottom-load Water Cooler

7. CARE AND MAINTENANCE

BEFORE OPERATING, READ ALL INSTRUCTIONS IN THIS MANUAL CAREFULLY.

Dehumidifier. SD-46 SD-46W: with Warm Air SD-46U: with UV Light SD-46UW: with UV Light and Warm Air. Instruction

MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL

Model: AW600. Triple Action Humidifier. Winix Inc. 120 Prairie Lake Road U nit E East Dundee, IL USA

QCM979D-38AGO ELECTRIC FIREPLACE HEATER NDF-65NB-3 INSTRUCTION MANUAL

USER OPERATING MANUAL

CLEAN MIST DUAL TANK SMART HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A

Installation & Operating Instructions

2 in 1 steam and blend

Water Distillation System Instruction Manual Nutriteam TC-501

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

AIR PURIFIER MODEL NO: APA240 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: GC1114

P O R T A B L E Air Conditioner

USER MANUAL AWLFSLCPJA

DK-11 Countertop Water System. Owner's Manual

CLEAN MIST SMART HUMIDIFIER Instruction Manual and Warranty Information IM0031B READ AND SAVE THESE INSTRUCTIONS

Connevans. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

I N S T R U C T I O N S

Contents. For your safety About your product Installing your appliance Using your appliance Care & cleaning...

557X-558X Comfort Care & Cozy Comfort, Premier Recliner 567X-5680 XL Cozy Comfort & XL Cozy Comfort Swing-Arm, Premier Recliner

R100 Oil-Less Refrigerant Recovery Unit

Ceiling Mount Air Purification System

humantouch.com use & care manual

TRIO Rx. Portable Ultra- High FAC Decanter Activator Set Instruction Manual

INSTALLATION GUIDELINES

PORTABLE AIR CONDITIONER WITH HEATER ... WA-9061 H" 9,000 BTU WA H" 10,000BTU

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

GENANO AIR PURIFICATION TECHNOLOGY

HOT TANK INSTALLATION INSTRUCTIONS

STEAM GENERATOR. Model: G-1030ST. Instruction Manual

This dehumidifier is both compact and lightweight. The casters on the bottom of the unit make it easy to move from room to room.

Using the Remote Control Unit

Portable Dehumidifier

Owners Manual - Incorporating Operation, Maintenance and Troubleshooting

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

Transcription:

Eco-$mart, Inc. (888)329-2705 info@eco-smart.com www.eco-smart.com LIQUID-AIR 1 (L-A 1) OPERATIONS MANUAL

TABLE OF CONTENT I. INTRODUCTION II. GETTING TO KNOW YOUR L-A 1 WATER GENERATOR 1. HOW DOES YOUR L-A 1 WORK? 2. WHAT KIND OF WATER DO I GET FROM THE L-A 1? III. OPERATING YOUR L-A 1 UNIT A. SETTING UP B. OPERATIONAL STAGE C. CLEANING AND REPLACING FILTERS IV. PRECAUTIONS V. MAINTENANCE VI. TROUBLESHOOTING VII. NOTES VIII. TECHNICAL SPECIFICATIONS

I. INTRODUCTION Thank you for purchasing the Liquid-Air 1. The Liquid-Air 1 (L-A1) is a new, stateof-the-art water-generating machine, which uses some of the latest and most sophisticated technology available in the industry today. We have designed your Liquid-Air 1 with one objective in mind i.e. to produce the most maximum amount of high quality drinking water while using only minimum amount of electricity. In addition to having undergone total redevelopment and redesign, your Liquid Air 1 also comes fully loaded with state-of-the-art features to reflect on the modern era and satisfy the technologically hungry consumers of the 21 st century. Liquid Air 1 boasts many new and exciting features such as: a. Microcomputer The unit is fitted with a microcomputer, which ensures proper working of internal parts, to regulate, supervise and control the functionality of individual parts inside the unit. b. Smaller and Lighter body The Liquid-Air 1 has a smaller and sleeker design compared to other generators in the market. The unit is more compact and versatile. Structural modifications and reinforcements were made to strengthen the unit, yet reducing the overall weight of the machine, keeping the total weight to minimum. c. Electronic sensors Various electronic sensors are attached to parts such as compressors, water pump, and UV light, heating mechanism and storage tanks. These sensors ensure that all parts are working properly and warn you should a breakdown or performance irregularities occur in the machine. d. Energy saving features To conserve electricity, electronic sensors have been placed in the storage tank to automatically stop the machine from making more water when the tank is full. e. Venturi fan Newly designed Venturi-type fan increases production efficiency and greatly reduce the noise during operation. f. New PVC Coated condensing coils Condensers designed especially so the unit will produce more water even in region with lower humidity. The coils are specially dipped in FDA approved PVC coating to prevent any metal parts from touching the water. g. Electrostatic Air Filter The first filter that air passes through before being condensed and converted to water; our electrostatic filter effectively prevents micro particles and dust from entering the machine.

h. Double Pass Ultra Violet Filter treatment Liquid Air s proprietary double pass ultra violet, not only treat the water to ultra violet light once, but twice to ensure that all bacteria and microorganism are eliminated. i. Taste and Odor Remover Carbon Filter Our dedication to providing high-quality, great tasting water to our consumers is seen in a brand new filter added to the machine. The MATRIKX +1 filter from KX is well known as the best taste and odor remover solid block carbon filter. This ensures that besides having pure, high-quality water, but our water also tastes great! j. Mineral Pack (Optional) Some of your machines may come with a mineral pack placed on the back of the machine. k. Overheating protection sensor The further protect the unit, your unit is fitted an overheating protection sensor, which automatically shuts off the machine should the problem occurs. l. Added insulation To enhance and add to the smoothness and ensures quiet operation of the unit. The noise level of the unit is reduced to less than 35 db at full operating level. m. Water re-circulation process Water inside the storage tank is completely recycled once every hour. This ensures that the water you store in the unit s tank is always fresh and sterilized even after it has been stored for a long time. n. Anti Bacterial Tank and tubing All plastic tanks and tubing are molded with FDA approved anti-bacterial chemical to further prevent any bacterial growth in the tanks and tubing. o. Humidity control (optional) To further save on energy cost, some machines may include a humidistat to control the machine s operation based on the humidity level in your area. The humidistat lets you set the machine to work at a certain humidity level and when it falls below the set level, the machine will simply shut off to save electricity. p. Tap Water inlet During times of low humidity and cold temperature, your machine may not produce enough water for the family. Simply hook the machine to your tap/city water lines and still obtain pure quality drinking water from your machine.

II. GETTING TO KNOW YOUR LIQUID-AIR 1 WATER GENERATOR 1. HOW DOES YOUR L-A1 UNIT WORK? It is important to be aware that your Liquid-Air 1 water generator is a humidity and temperature driven machine. This means the machine totally depends on the level of humidity in the air and the temperature to produce water. Ideally, the humidity level should be at least 65% - 70% to achieve the machine s optimum performance. Naturally, the more humidity that exists in the area, the more water the machine will produce. In terms of temperature, the machine would be at its most optimum level of production when placed in warmer temperature areas. The machine will still produce water in lower humidity region but not as quickly, nor as much as in places with high level of humidity. Before placing the machine in a certain part of the house or office, you would do well to use the Humidity and Temperature Gauge provided when you purchase the machine and carefully check the level of humidity. In the house environment, higher level of humidity tends to be around the kitchen area, near an open window or in larger, more spacious rooms. The machine also depends on the temperature to operate at its optimum level. The ideal temperature is around 75º to 85º F. This does not mean that your machine will not work in temperature below or above the ideal range. But the machine will produce more water faster and quicker when placed within the ideal temperature range. You would also do well to use the Humidity and Temperature Gauge to check the temperature in the room prior to placing the machine in a certain room. Because your Liquid-Air 1 works by converting the humidity in the air to water, this unit also acts as an effective dehumidifier. Do not operate the unit in a room where a certain level of humidity is required for health or other reason. Alternatively you can open the window to exchange the air inside and outside the room, and then the unit is operational. 2. WHAT KIND OF WATER DO I GET FROM THE LIQUID-AIR 1? Through our numerous filtration processes, the LA-1 produces the purest, high quality drinking water available today. The water produced is not only pure and free of any water contaminants, but also beneficial to your health. Water from Liquid-Air 1 generators provides the following overall benefits to the consumers: A. Avoid environmental pollution and provide pure water free of bacteria and fertilizer B. Increase mineral beneficial for health to better athletic performance C. Rich of oxygen to make better delivery of nutrients to all the cells, tissues and organs through blood

D. Improve blood circulation enhance removal of waste, efficiently converts nutrients into energy and transports all the waste resulting from burnt energy out of the cells E. Improves overall metabolism and provide more energy, build up the body resistance and helps to improve physical condition making one less prone to diseases III. OPERATING YOUR LIQUID-AIR 1 WATER GENERATOR By following these simple instructions and simple maintenance procedures, your Liquid-Air water generator should give you years of trouble-free operation while producing the most maximum amount of pure, high-quality, drinking water that is not only healthy, but also beneficial to your health. Please read this operation manual carefully before you start the machine. By reading and following the simple manual, you will familiarize yourself with your new water machine and all its functions, ensuring yourself of a machine constantly operating at its optimum level. Operational Indicators Hot water spout Cold water spout Ventilation panel Front panel/door OPERATIONAL INDICATORS

COOL The above is what you will see on the right hand corner of the Operational Indicators label. Please pay attention to these as they constantly indicate how your machine operates at the time: a. WARNING when lit up, a beeping noise is emitted from your machine. When this happens, first check the ultra-violet (UV) bulb to ensure that it is working. Check that all electrical and water connections are secure. Also follow the trouble-shooting procedure. If you have done all these and the warning light still comes on when you turn on the machine, please call an authorized service facility to have this problem remedied. b. COOL when lit, your machine is cooling the water in the cold water tank. c. HOT when lit up, your machine is heating the water in the hot water tank. d. POWER indicating that your machine is on. When your machine is full, the compressor will switch off but the red power light will still be lit to indicate that your machine is still operational. e. PUMP when your machine is pumping water from the bottom storage tank to the upper tank, the pump indicator will be lit. f. RUN is indicated by a green light, which indicates that the machine s compressor is running and making water. For more trouble-shooting, tips and other techniques, please refer to our website at: http://www.liquidairinc.com

a. SETTING UP 1. Before setting up to operate, choose a location in the house/office with the highest temperature and humidity, and the unit should remain on a standing position before plugging into the electrical socket. Note: Just like any appliance with Freon, you should let the machine in a standing position for at least 6 hours before turning it on. 2. The unit should be placed on solid and level ground, no less than 20 cm from the wall. 3. Before inserting the electrical cable into the socket, make sure the power switch on the back panel is in the OFF (0) position. 4. Insert into electrical socket capable of handling no less than 12A. Power supply is A/C 120V/60Hz. 5. Turn the power on using the RED SWITCH (I). The power light should immediately come on accompanied by a single beep b. OPERATIONAL STAGE 6. When the unit starts to operate, you should be able to hear the fan and the compressor running after one minute. The light (RUN) on the front upper panel should also be lit. If you do not see or hear any of the above, refer to the troubleshooting manual. 7. A Water Production Chart is provided on the side of the machine to let you gauge how much water your machine should produce on a daily level. Do not be alarmed if your machine does not produce as much water as the Production Chart indicated in the first few days. Upon initial operation, your machine takes up to 3-4 days to acclimatize itself to its new surrounding or environment. Full water production should be easily obtained within one week of operation. 8. Do not be alarmed when you do not obtain hot or cold water during the first few days of operation. We have designed the heating and cooling mechanism to be triggered on when the machine is full. When the heating/cooling mechanism is triggered both the HOT and COOL indicator lights would be lit. Thereafter, your water should remain hot and cold 24 hours a day even when your machine is full and the compressor has been turned off. 9. Do not be alarmed when the HOT and COOL indicator lights on the front panel turns on and off after a few minutes. The unit has been fitted with a temperature sensor, which automatically turns the heating/cooling mechanism on and off depending on the temperature and amount of water stored in the hot and cold tanks.

10. Do not be alarmed when your machine turns off automatically. To conserve energy, your machine has been fitted with an electronic sensor, which automatically switches the machine off when the storage tank is full. 13. It is best to switch off the unit or unplug the power cord during long period of inactivity or during a long-term power failure. 14. During period of long inactivity, you can keep your machine in optimum shape, by following these simple procedures: Drain out all remaining water in storage tank by opening the spout located on the bottom right corner of the storage tank. Open the front panel of the machine and wipe off remaining condensation on condensing coils and all internal mechanism with a sponge until dry. 15. In some areas, your machine may be equipped with a Humidity Control. The Humidity Control or Humidistat is placed inside the machine. To access it, open the front panel and you will see a dial with various humidity levels. The humidistat works by turning off the machine if the humidity level falls below the set humidity level and turns the machine on again when the humidity level has increased above the set level. The humidistat is set at 30% at our factory but if you prefer to set it at a different level, please feel free to do so. For example, if you set the humidistat at 60%, the machine will shut off if the humidity level falls below 60% and the machine will turn on again when the humidity level is above 60%. c. REPLACEMENT OF FILTERS 16. With regular usage, we recommend that you replace the filters once a year. This is to ensure that your unit will always produce the cleanest and purest drinking water. The unit is designed for easy access and simple replacement procedures. Please remember to dispose these filters properly. LF 2 Carbon Filter Replacement Procedure a. Switch off the unit and unplug power cable from socket before replacing. b. Remove front door/panel by gently pulling it away from the unit c. Depress red lever at the bottom of storage tank and gently slide the tank ¾ of the way out

d. Turn the mineral filter (LF2) canister counter-clockwise to unlock and lift out to remove. e. Insert new mineral filter canister by inserting into the storage tank and lock by turning the canister clockwise. f. Depress red lever and slide storage tank back to its original position. g. Replace front panel by lining up the mounting pins to the holes and push panel tight against the machine. LF3 Carbon Filter Replacement Procedure a. Switch off the unit and unplug power cable from socket before replacing. b. Remove front door/panel by gently pulling it away from the unit c. Twist off the carbon filter canister (LF3) from its mounting bracket d. Take the filter out of its canister and replace with a new filter. e. Do not forget to flush the new filter with water for at least 15 minutes prior to installation e. Replace front panel by lining up the mounting pins to the holes and push panel tight against the machine. 17. The ultraviolet (UV) lamp (LF1) may become invalid over a lengthy period of operation time. When this unit is not working properly or damaged, an alarm will sound and the machine shuts off automatically. When this happens, make sure that the UV lamp is replaced immediately. UV lamp (LF1) replacement procedure: a. Switch off the unit and unplug power cable from socket before replacing. b. Remove front door/panel by gently pulling it away from the unit c. Pull out electric connecters from the bulb d. Slide one hand behind the aluminum canister and push out with finger while using the other hand to grab the bulb. e. Twist and pull the bulb out of the aluminum canister f. Take new UV bulb of the same specification and insert into the canister, using one hand to line up the hole on the other side the canister g. Replace connectors to the bulb. h. Replace front panel by lining up the mounting pins to the holes and push panel tight against the machine. 18. Depending on how polluted the air is in your area, the air filter must be cleaned often to ensure proper airflow. To clean the air filter: Use the tool-kit provided in your unit, and loosen the screws on the left ventilation panel Pull panel out.

Take the air filter and rinse with water until clean Replace both filter and ventilation panel back onto the machine 19. Mineral Pack Replacement Procedure (Optional) If your machine comes with the Mineral Pack, then it would be best to replace the Mineral once per-year to ensure optimum mineral content in your drinking water. a. Unscrew the top part of the back panel of the machine. b. You will see the Mineral Pack on the upper left-hand corner of the back of the machine. c. Disconnect the water lines from the top and bottom of the mineral pack d. Replace with new Mineral Pack e. Connect the water lines to the top and bottom of the pack.

IV. PRECAUTIONS 1. Do not place the unit too close to the wall. Best performance is obtained when the unit is placed at least 8 inches from the wall. 2. Avoid exposure to heat 3. Avoid prolonged exposure to direct sunlight 4. Avoid placing valuable articles on the machine 5. Operating voltage must not drop below AC 90V. When the unit operates below this level, the unit becomes noisy with the possibility of overheating. When this occurs, immediately switch the unit off until the voltage returns to normal. 6. If the heat temperature sensor is out of order, the overheat protection mechanism will automatically switch off the heating mechanism to protect the unit. Note that the overheat protection sensor must be reset manually. Please call a service agent when this occurs. 7. Avoid opening the front door/panel when the unit is operating. 8. Avoid prolonged direct eye exposure to ultraviolet device as it may damage the eye.

V. MAINTENANCE Always keep the unit clean. Wipe the outer casing with soft, damp fabric to clean. Use water to clean, avoid using harsh cleaning agent. Do not use cleaning agent to clean storage tanks. Clean internal parts and mechanism often, keeping free of dust and dirt. Replace all filters (LF1, LF2 and LF3) once a year Clean air filters often to ensure proper air flow Always drain remaining water from the tanks before a period of long inactivity. Even though the storage tanks are made with anti-bacterial agent but we highly recommend that you regularly wash your tanks. To do so, simply slide out the bottom storage tank by unhooking all the water lines and rinse the inside of the storage tank with clean or distilled water and regular dishwashing liquid. Please remember to rinse the tank thoroughly with warm water after washing so that no residues are left in the tank.

VI. TROUBLESHOOTING Before proceeding on the following, please make sure that the unit is not plugged in and the power switch is in the OFF position. Problem: The WARNING light comes on and the machine does not work Solution: Check the ultraviolet device. Make sure the unit is working properly and all the cables are properly connected. If the ultraviolet lamp is not working, replace it immediately following the steps above. The machine is designed to stop functioning when the ultraviolet lamp is not working to prevent consumers from drinking impure water. Problem: The machine does not work even after the power cord is plugged in. Solution: Check for proper power voltage and ensure that it is in the correct range for operation. Check that the power switch (RED) is turned ON. Make sure that the connection to the wall socket is tight and secure. Problem: The machine makes water at a slow rate even after prolonged period of operation. Solutions: Make sure the temperature level is at the correct range. Check the humidity level in the room. Low humidity level results in less water production. Make sure that the hot/cold waterspouts are not blocked. Make sure that the ingoing and outgoing air ventilation is not blocked. Check that the distance between the machine and the wall is not too close. Make sure that the power voltage is not too low or too high. Make sure that the internal water pump is operational. Make sure that the air filter net is cleaned regularly to ensure the free air flow.

VII. NOTES Once all the above procedures have been performed and your machine still does not work or does not work correctly, please do not try to perform other repair procedures yourself. Liquid-Air Inc is not responsible for any damages incurred during self-reparation of the machine. Always call a qualified service technician to look at the machine and perform the repair procedures. Liquid-Air Inc is not responsible for any damages incurred during self-reparation and voids all warranty. When calling a service technician, please have your name, address and unit serial number (which can be found on the yellow sticker on the right upper panel) ready. For other trouble-shooting tips and techniques, you can also log into our web-site at: http:www.liquidairinc.com For other questions or comments, please call our office or send your mails to: LIQUID-AIR INC. 249 East Ocean Boulevard Suite 1010 Long Beach, CA 90802 Tel: (562) 983-6388 Fax: (562) 983-5098 Contact us at: http://www.liquidairinc.com

VIII. TECHNICAL SPECIFICATIONS FRONT VIEW SIDE VIEW REAR VIEW a. DIMENSIONS: Height 43 Width 15.7 Depth 15.4 Net Weight 93.5 lb Noise level less than 35 db b. POWER: Voltage 120 VAC Current 9.5 A Frequency 60 HZ Power consumption 650 W. Heater consumption 500 W.

c. WATER PRODUCTION (24 HOUR PERIOD) (in Gallons) d. COEFFICIENT OF WATER QUALITY ITEM DATA Degree of turbidity < 5 Total hardness 450 mg/l Color 15 PH value 7 Temperature of hot water > 95 C Temperature of cold water < 9 C Water storage capacity 4.3 gallons