SVF-8DC. Manual No. BLWR007 Rev. 3 February 2014

Similar documents
OPERATING MANUAL 12 AXIAL FANS

SVB-E8EXP SVB-A8 SVB-G8 SVB-G8P SVB-E8-2. Manual No. BLWR001 Rev. 7 April 2013

OPERATING INSTRUCTIONS AND REPLACEMENT PARTS

Models: 50-ALM, 50-ALMAA, 50-ALMH, 50-ALMP, 50-ALMST 50-ALMSTAA, 50-ALMSTH, 50ALMSTHAA, 50-ST, 50-ALM-2J

The Saddle Vent. & Ventilation Kits. Confined Space Entry Do it Right The First Time. Leading The Safety Industry Since 1984

& Ventilation Kits. Confined Space Entry Do it Right The First Time. Leading The Safety Industry Since 1984

Models: CO-91IS and CO-91ISLA

Quest Power Electric Heat EHS 31 Pro

Quest PowerHeat HFC 100 Pro

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

Owner s Manual Phoenix FireBird

Quest Power Electric Heat EHS 62 Pro

1 HP Air Mover. Owner s Manual

Owner s Manual Phoenix Aquadry TX 200

UB20 12V DC. Owner s Manual

XC Portable Air Conditioning

Industrial Dehumidifier Operating Instructions. Model: VG 1500

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

RP, GP, XP Pro Series Installation Instructions

Remote Relay Module (RRM)

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

GALE FORCE VAF-16R. Ventilation Manual

Operating Instructions & Parts Manual Models 99533, 99532

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

IN020 Rev F Page 1 of 8

HotPoly Tote Tank / IBC Heaters (TTH Series)

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

VENTILATION FAN / LED LIGHT

HUMIDITY SENSING BATH FAN

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

(HSTAT Series) Instruction Manual

Owner s Manual Hydro-X Vacuum Pac

USER S MANUAL for AXIAL BLOWERS

OmniDry 2.9 Amp Centrifugal Air Mover

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

40E ELECTRIC FAN HEATER

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

Please Read and Save These Instructions.

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

IN014 Rev P Saber Way, Ward Hill, MA radonaway.com

Air Pump Up to 800 gallons

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

PNEUMATIC VACUUMS ATEX Certified For Hazardous Locations OPERATING MANUAL

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

MaxLite LED Round Pendant Highbay Series

ion Genesis Pump Controller

e Bath Fan with Light User s Guide

Installation & Maintenance Instructions

MODEL CDB8 INSTALLATION INSTRUCTIONS

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

Gen-Air Air Mover. Gen-Air Air Mover. Safety, Operation and Maintenance Manual with Parts List Please read before use! 1/2 HP, 3-Speed Motor

C-Box 100, H-Box 200 & H-Box 500

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

breeze easytm model # F100-1W

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Confined Space Ventilation equipment

MaxLite LED Vapor Tight Linear Fixture

40E ELECTRIC FAN HEATER

IMPORTANT SAFETY INFORMATION:

IMPORTANT SAFETY INFORMATION:

e Heater/Exhaust Fan/Light User s Guide

LINEAR AIR PUMPS INSTRUCTION MANUAL SERIES PRO TM

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

e Bath Fan with Light User s Guide

Please Read And Save These Instructions.

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

IMPORTANT SAFETY INFORMATION:

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Phoenix AirMAX - Radial Air Mover

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

ELECTRIC FIREPLACE OWNER S MANUAL

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SF180 Installation Instructions

Installation and Maintenance Manual Please retain this manual for future reference.

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

Industrial LGR Dehumidifier Operating Instructions. Model: VG LGR 3000

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

5-Gallon Pail Mixer OWNERS MANUAL M-2000 SERIES MIXERS. Contents: Page: Safety, General & Receiving... 2 Operation... 3 Parts List...

VENTILATION FAN WITH LIGHT AND HEATER

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

e Bath Fan with Light User s Guide

Installation & Maintenance Instructions

User s Manual and Operating Instructions

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Series: MBC1-TC Mini Benchtop Temperature Controller

24 & 30 Quiet Design Oscillating Wall Mount Fan

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

High-Velocity Floor Fan

Transcription:

Manual No. BLWR007 Rev. 3 February 2014 OPERATING MANUAL SVF-8AC SVF-6ACAN SVF-15ACAN SVF-25ACAN MODELS: SVF-8DC SVF-6DCAN SVF-15DCAN SVF-25DCAN Air Systems International, Inc. 829 Juniper Crescent, Chesapeake, Va, 23320 Telephone (757) 424-3967 Toll Free 1-800-866-8100 Fax No. (757) 424-5348 http://www.airsystems.com e-mail: sales@airsystems.com

2 The Saddle Vent Ventilation System Typical Saddle Vent Setup Procedure Place fan or blower a minimum of 5 ft. (1.6m) from manhole opening Blower or Fan Manhole Lid 90 Elbow Manhole Opening Select a blower or fan based on environmental conditions and the size of the confined space. For information or guidance in selecting the proper set-up, please contact Customer Service. Universal Mount Saddle Vent STEP 1) Install 6 ft. (1.8m) duct on blower or fan STEP 2) Install 90 elbow on top of Saddle Vent STEP 3) Install duct on bottom of Saddle Vent STEP 4) Install universal mount on Saddle Vent and set in place with manhole lid for support STEP 5) Install duct from blower to 90 elbow STEP 6) Turn on blower or fan Warning: For explosive environments, follow ANSI/API 2015 and 2016 procedures WArninG: HAZArDoUS location operations Use an explosion-proof or intrinsically safe blower or fan, conductive ducting, and the conductive Saddle Vent system. Attach all grounding wires and assure a complete circuit to the blower or fan in order to remove static charges. The Saddle Vent is a registered trademark of Air Systems International, Inc. The Conductive Saddle Vent is covered by U.S. and Foreign Patents

3 SAFety PrecAUtionS read AnD FolloW All instructions BeloW All ventilation procedures should comply with federal, state, and local regulations. Air quality should be tested prior to ventilating a confined space. A purge chart is provided in this manual help assist in estimating the approximate time needed to ventilate confined spaces. Air quality should be tested continuously during confined space occupancy to ensure a stable atmosphere and worker safety as atmospheric conditions can change rapidly. Additional procedures and recommendations are available from federal, state, and local agencies. Do not operate these fan units in a vertical position or with the flange or guards removed. WArninG Fan and blower models with the EX or X designation are the only models approved for use in hazardous locations. If volatile or explosive vapors are suspected, use Air Systems explosion proof electric blower, Model SVB-E8EXP, explosion proof in-line fan, Model SVF-10EXP, explosion proof contractors fan, Model CVF-8EXP or Air Systems intrinsically safe pneumatic blower, Model SVB-A8. Note: For confined space ventilation in non-hazardous locations, use Air Systems confined space ventilation kit, Model SV-CUP. For hazardous locations use ventilation kit, Model SV- CUPCND along with one of the above explosion proof blowers or fans.

GENERAL SET-UP AND OPERATION FOR SVF-8AC AND SVF-8DC MODELS 1) Place fan in a clean, fresh air environment. 2) Air quality of the confined space should be tested prior to ventilation. If air quality of the confined space is unacceptable, consult a trained professional. 3) Inspect fan for damaged or worn parts, and inspect ducting for air leaks prior to fan operation. 4) Install duct cuff to exhaust flange and secure. Keep bends and kinks in ducting to a minimum to maximimize air flow. If canister model is used, secure canister with connect straps, open lid and pull out ducting. Inspect for air leaks. Note: Maximum recommended duct hose length is 25 ft. 5) Set fan upwind from the work location and a minimum of 5 ft. from the manhole opening. 6) Connect fan to power source. DC versions require 12 VDC. Attach the red connector to the positive (+) terminal and the black conector to the negative (-) terminal. This unit must be run in the positive pressure mode as this model is not approved for extracting (sucking) air. DO NOT REVERSE WIRING. WARNING: Vehicle electrical systems must be able to handle 15 amp service or electrical damage may occur. AC versions require 115 VAC/60Hz, 15 amp service or 220 VAC/50Hz. Note: If an extension cord is required, the minimum recommended size is 14 AWG up to 25 ft. For further information refer to the National Electric Code Tables, Article 400. 7) Push on/off switch to I position. 4 ProBlem PoSSiBle cause SolUtion Air intake blocked Turn fan off and clear debris from intake. Turn off and inspect fan blades, shaft, and housing for debris, damage, and loose screws. Possible internal damage Excessive vibration Note: Never run fan for extended periods without installing duct on the exhaust flange. Possible external damage Turn fan off and inspect for loose guards, broken welds, etc. Voltage output insufficient Test outlet with volt meter. Circuit breaker trips Extension cord improperly sized Use 14 AWG extension cord up to 25 ft. SVF-8AC series only Faulty Capacitor Check and Replace with P/N MTRA089 Fan will not run SVF-8DC only troubleshooting Blown fuse (DC version only) Battery connection Check and replace. Use only a 20A/32 VDC slow blow fuse. Ensure proper connection from battery clips to battery terminal posts. On battery pack units, recharge battery.

5 REPLACEMENT PARTS - AC VOLTAGE FANS An optional GFI (Ground Fault Interrupter) cord/plug can be supplied to comply with the 1996 NEC Code requirement: Section 305-6. Order P/N ELCB013. ITEM # DESCRIPTION PART # 1 INTAKE GUARD MGDAXFAN1 2 FAN SV-FAN-8MM 3 HANDLE HDWR056 4 ELECTRIC MOTOR WITH CAPACITOR SVF-8AC-MA 5 DISCHARGE GUARD MGDAXFAN2 6 ON/OFF SWITCH ELSW038R 7 POWER CORD ELCB012 8 CAPACITOR MTR043CNC 9 RUBBER FOOT HDWR026 10A 8 DIA.X 6 LONG DUCT SVF-H6 10B 8 DIA. X 15 LONG DUCT SVF-H15 10C 8 DIA. X 25 LONG DUCT SVF-H25 11 DUCT CANISTER SVF-CAN SPECIFICATIONS MOTOR TYPE OUTLET SIZE FLOW RATES 1/3 HP (.23 kw) electric, 115 VAC/60 Hz, 2.6 amps, Capacitor Start, Single Speed, 3200 RPM, CSA Approved 8 Diameter (203mm) Free Air: 1395 cfm 15 ft. duct with one 90 bend: 840 cfm 15 ft. duct with two 90 bends: 750 cfm

6 REPLACEMENT PARTS - DC VOLTAGE FANS ITEM # DESCRIPTION PART # 1 INTAKE GUARD MGDAXFAN1 2 FAN SV-FAN-8MM 3 HANDLE HDWR056 4 12 VDC ELECTRIC MOTOR WITH INLINE FUSE/FUSE HOLDER MTR044CN 5 20A 32 VDC IN-LINE FUSE ELF022 6 DISCHARGE GUARD MGDAXFAN2 7 ON/OFF SWITCH ELSW038R 8 POWER CORD ELCB045 9 RED BATTERY CLAMP ELA083R 10 BLACK BATTERY CLAMP ELA083B 11A BATTERY CONNECTOR FOR OPTIONAL BATTERY PACK (P/N BP-950) ELA127 11B 1 PAIR OF CONTACTS FOR ELA127 ELA126 12 RUBBER FOOT HDWR026 13A 8 DIA.X 6 LONG DUCT SVF-H6 13B 8 DIA. X 15 LONG DUCT SVF-H15 13C 8 DIA. X 25 LONG DUCT SVF-H25 14 DUCT CANISTER SVF-CAN MOTOR TYPE OUTLET SIZE FLOW RATES SPECIFICATIONS 1/6 HP, 13.5 VDC, 15 amps, Single Speed, 4200 RPM, 20 amp/32 VDC Slow Blow Fuse 8 Diameter (203mm) Free Air: 1170 cfm 15 ft. duct with one 90 bend: 815 cfm 15 ft. duct with two 90 bends: 796 cfm

7 WIRING SCHEMATIC - SVF-8AC-MA

WArrAnty DiSclAimer Air Systems manufactured equipment is warranted to the original user against defects in workmanship or materials under normal use for one year from the date of purchase. Any part which is determined by Air Systems to be defective in material or workmanship will be, as the exclusive remedy, repaired or replaced at Air Systems option. This warranty does not apply to electrical systems or electronic components. Electrical parts are warranted, to the original user, for 90 days from the date of sale. During the warranty period, electrical components will be repaired or replaced at Air Systems option. no other WArrAnty, expressed or implied, AS to DeScriPtion, QUAlity, merchantability, FitneSS For A PArticUlAr PUrPoSe, or Any other matter is GiVen By Air SyStemS in connection Here- WitH. UnDer no circumstances SHAll the Seller Be liable For loss of ProFitS, Any other Direct or indirect costs, expenses, losses, or DAmAGeS AriSinG out of DeFectS in, or FAilUre of the ProDUct or Any PArt thereof. The purchaser shall be solely responsible for compliance with all applicable Federal, State and Local OSHA and/ or MSHA requirements. Although Air Systems International believes that its products, if operated and maintained as shipped from the factory and in accordance with our operations manual, conform to OSHA and/or MSHA requirements, there are no implied or expressed warranties of such compliance extending beyond the limited warranty described herein. Product designs and specifications are subject to change without notice. rev. 2, 12/98 Air leaks are not covered under warranty except when they result from a defective system component, i.e. an on/off valve or regulator or upon initial delivery due to poor workmanship. Air leaks due to poor delivery or damage will be covered under delivery claims. Minor air leaks are part of routine service and maintenance and are the responsibility of the customer just as are filters and oil changes.