Installers Guide. Models: 7000TV 6000TVB

Similar documents
Heat-N-Glo. Installers Guide. Model: 8000TVC

Owner s Manual Installation and Operation

Heat-N-Glo Fireplace. Installers Guide. Model: AT-GRAND

Owner s Manual Installation and Operation

Owner s Manual DO NOT DISCARD WARNING CAUTION WARNING. Model: 6000PLUS

Installers Guide. Models: 7000XLS 6000XLSB

This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;

Heat-N-Glo Fireplace. Installers Guide. Model: BAYFYRE-TRS

Heat-N-Glo Fireplace. Installers Guide. Model: GRAND-50

Installers Guide. Model: BAY-38HV

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

Heat-N-Glo Fireplace. Installers Guide. Models: SL-36 SL-36GDV SL-32 SL-32GDV SL-32S. Underwriters Laboratories Listed.

Owner s Manual Installation and Operation

Installers Guide. Model: CFX-ZC

Owner s Manual Installation and Operation

Installers Guide. Model: CFX-DIAMOND

Installers Guide. Models: 6000TRI-IPI 6000TRI-SP

Owner s Manual. Models: 6000TR-OAK 6000TR-OAK-IPI

Owner s Manual. Model: 6000TRXI-IPI

INSTALLATION AND OPERATING INSTRUCTIONS

Quadra-Fire, a brand of Hearth & Home Technologies 1445 North Highway, Colville, WA 99114

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

Owner s Manual Installation and Operation

SOUTHWEST FIREBIRD MFG SONORAN UNVENTED Model 36/42/48

Owner s Manual Installation and Operation

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Installation/Operating Instructions

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION OPERATION AND SERVICE MANUAL

GAS -FIRED VENTED ROOM HEATERS MODEL 61TV

Models #CSK-31 #CSK-31-RF. CHASKA Direct Vent Gas Fireplace Insert INSTALLATION & OPERATING MANUAL

Models #CSK-335 #CSK-335-RF. CHASKA - XL Direct Vent Gas Fireplace Insert INSTALLATION & OPERATING MANUAL

Owner s Manual Installation and Operation

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL

Legend VENTED GAS FIREPLACE HEATERS

3000 SERIES DIRECT VENT GAS FIREPLACE INSTALLATION AND OPERATING INSTRUCTIONS WARNING

STONE RIVER. The White Mountain Log Collection: LSU24SF-2 Shown

Installation Instructions

f i r e - p a r t s. c o m

#CSK-31-RF. CHASKA Direct Vent Gas Fireplace Insert INSTALLATION & OPERATING MANUAL

The White Mountain Log Collection: ROCK CREEK

INSTALLATION AND OPERATING MANUAL

The White Mountain Log Collection BIRCH

INSTALLATION INSTRUCTIONS

INSTALLATION OPERATING, AND SERVICE INSTRUCTIONS FOR SUBURBAN DIRECT VENT SEALED COMBUSTION GAS HEATER MODEL GT-10D

UVST (SMOOTH FACE) UVCST (HEAT CIRCULATING) INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING MANUAL

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

INSTALLATION AND OPERATION INSTRUCTIONS MODEL: ATS-AU-D. AUSTRALIAN GAS ASSOCIATION APPROVED AGA Approval Number 5543 WARNING

INSTALLATION AND OPERATING MANUAL

UNVENTED (VENT-FREE) GAS LOG HEATER OWNER S OPERATION AND INSTALLATION MANUAL

Installation instructions for the T 9820 Gas Dryer

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

SURE HEAT MANUFACTURING

USERS INSTALLATION OPERATION and MAINTENANCE MANUAL. Installer: Please leave this manual with the appliance owner for future reference

INSTALLATION INSTRUCTIONS

CAUTION FOR YOUR SAFETY

PONDEROSA. The White Mountain Log Collection MODELS LS-18P-2 LS-24P-1 LS-30P-1 GAS-FIRED

Comfort UNVENTED (VENT-FREE) GAS LOG HEATER OWNER S OPERATION AND INSTALLATION MANUAL

USERS INSTALLATION OPERATION and MAINTENANCE MANUAL. Installer: Please leave this manual with the appliance owner for future reference

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

UNVENTED (VENT-FREE) GAS LOG HEATER

MODEL: SL-350TRSI-AUE

PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING AND

USER S INFORMATION MANUAL

NOTICE DO NOT DISCARD THIS MANUAL. Read, understand and follow these instructions for safe installation and operation.

CBO-750 HYBRID-R OVEN Instructions Manual

MODEL 34 MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A ZERO CLEARANCE FIREPLACE OR WITH AN OPTIONAL SURROUND.

MODEL 36 MAY BE INSTALLED AS A ZERO CLEARANCE FIREPLACE OR WITH AN OPTIONAL WOODEN SURROUND

INSTALLATION & OPERATING MANUAL

ROYAL ENGLISH OAK AND WINCHESTER OAK UNVENTED (VENT-FREE) GAS LOG HEATER

Multi-Function Cooktop

USERS INSTALLATION OPERATION AND MAINTENANCE MANUAL

ULTRA FLAME DIRECT VENT "0" CLEARANCE GAS FIREPLACE INSTALLATION AND OPERATING INSTRUCTIONS

PRE-PLANNING GUIDE for the Linear Burner System

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

ROYAL ENGLISH OAK UNVENTED (VENT-FREE) GAS LOG HEATER OWNER S OPERATION AND INSTALLATION MANUAL

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

UNVENTED (VENT-FREE) GAS LOG HEATER OWNER S OPERATION AND INSTALLATION MANUAL

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Owner s Manual Installation and Operation

MODEL: SL-550TRSI-AUE

INSTALLATION OPERATION AND SERVICE MANUAL

PVK-80 Power Vent - Installation Instructions -

DANGER HOT GLASS WILL CAUSE BURNS. DANGER. ILDV Series Direct Vent Gas Fireplace Insert Installation and Operating Instructions

UNVENTED (VENT-FREE) GAS FIREPLACE INSERT OWNER S OPERATION AND INSTALLATION MANUAL For more information, visit

WARNING INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL

MODEL 42 MAY BE INSTALLED AS A ZERO CLEARANCE FIREPLACE OR WITH AN OPTIONAL WOODEN SURROUND

PFS VENT-FREE GAS SYSTEM OWNER'S OPERATION AND INSTALLATION MANUAL

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER ALSO DESIGN-CERTIFIED AS A VENTED DECORATIVE APPLIANCE

UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER

INSTALLATION AND OPERATING INSTRUCTIONS VENT FREE GAS LOGS

UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE

Repeat procedures for other side.

Transcription:

Models: 7000TV 6000TVB Installers Guide Underwriters Laboratories Listed WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUS- ING PROPERTY DAMAGE, PER- SONAL INJURY, OR DEATH. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - What to do if you smell gas Do not try to light any appliance. Do not touch any electrical switch. Do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency, or the gas supplier. READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE. THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE. WARNING: IMPROPER INSTALLA- TION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAM- AGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFOR- MATION CONSULT A QUALIFIED IN- STALLER, SERVICE AGENCY, OR THE GAS SUPPLIER. Please contact your Heat-N-Glo dealer for any questions or concerns. For the number of your nearest Heat-N-Glo dealer, please call 952-985-6000. Printed in U.S.A. Copyright 2000, Heat-N-Glo, a division of Hearth Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322; 4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia) 543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending. 1 522-902F 9/00

SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the installation. FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty. These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide. NO OTHER vent systems or components MAY BE USED. Prior to the first firing of the fireplace, READ the Using Your Fireplace section of the Owners Guide. DO NOT USE this appliance if any part has been under water. Immediately CALL a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water. THIS UNIT IS NOT FOR USE WITH SOLID FUEL. This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance MUST USE a separate vent system. Common vent systems are PROHIBITED. INSPECT the external vent cap on a regular basis to make sure that no debris is interfering with the air flow. Installation and repair should be PERFORMED by a qualified service person. The appliance and venting system should be INSPECTED before initial use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is IMPERATIVE that the unit s control compartment, burners, and circulating air passageways BE KEPT CLEAN to provide for adequate combustion and ventilation air. The glass door assembly MUST be in place and sealed, and the trim door assembly MUST be in place on the fireplace before the unit can be placed into safe operation. DO NOT OPERATE this appliance with the glass door removed, cracked, or broken. Replacement of the glass door should be performed by a licensed or qualified service person. DO NOT strike or slam the glass door. Always KEEP the appliance clear and free from combustible materials, gasoline, and other flammable vapors and liquids. NEVER OBSTRUCT the flow of combustion and ventilation air. Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operations. The glass door assembly SHALL ONLY be replaced as a complete unit, as supplied by the gas fireplace manufacturer. NO SUBSTITUTE material may be used. DO NOT USE abrasive cleaners on the glass door assembly. DO NOT ATTEMPT to clean the glass door when it is hot. Due to the high temperature, the appliance should be LOCATED out of traffic areas and away from furniture and draperies. Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance. Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition. Young children should be CAREFULLY SUPERVISED when they are in the same room as the appliance. Turn off the gas before servicing this appliance. It is recommended that a qualified service technician perform an appliance check-up at the beginning of each heating season. Any safety screen or guard removed for servicing must be replaced before operating this appliance. 2

TABLE OF CONTENTS Safety and Warning Information.... 2 Service Parts Lists.... 4 Section 1: Approvals and Codes.... 8 Approval Listings and Codes... 8 Appliance Certification... 8 Installation Codes... 8 High Altitude Installations... 8 Section 2: Getting Started... 9 Introducing the Heat-N-Glo Gas Fireplaces... 9 Pre-installation Preparation... 9 Section 3: Installing the Fireplace.... 11 Step 1 Locating the Fireplace... 11 Step 2 Framing the Fireplace... 11 Step 3 Negative Pressure Make-up Air... 12 Step 4 Installing the Vent System... 13 A. Vent System Approvals... 13 B. System Components... 13 C. Bedroom Installation in Canada... 14 D. Vent Termination... 14 Step 5 Positioning, Leveling, and Securing the Fireplace... 14 Step 6 The Gas Control Systems... 14 ustep 7 The Gas Supply Line... 15 Step 8 Gas Pressure Requirements... 15 Step 9 Wiring the Fireplace... 16 Step 10 Finishing... 18 Step 11 Installing Trim, Logs, and Ember Material... 18 Installing the Trim... 18 Positioning the Logs... 18 Placing the Ember Material... 18 Step 12 Before Lighting the Fireplace... 19 Step 13 Lighting the Fireplace... 19 After the Installation... 19 Section 4: Maintaining and Servicing Your Fireplace.... 20 u = Contains updated information. 3

1Approvals and Codes Appliance Certification The Heat-N-Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories. Certification MODELS: 7000TV, 6000TVB LABORATORY: Underwriters Laboratories TYPE: Direct Vent Gas Fireplace STANDARD: ANSI Z21.50 CGA2.2 Installation Codes The fireplace installation must conform to local codes. Before installing the fireplace, consult the local building code agency to ensure that you are in compliance with all applicable codes, including permits and inspections. In the absence of local codes, the fireplace installation must conform to the National Fuel Gas Code ANSI Z223.1 (in the United States) or the CAN/CGA-B149 Installation Codes (in Canada). The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes with the National Electric Code ANSI/NFPA No. 70 (in the United States), or to the CSA C22.1 Canadian Electric Code (in Canada). These models (natural gas and propane) can be installed in a bedroom (in the United States) which has a total volume of unconfined space appropriate to the particular installation. Refer to the National Fuel Gas Code ANSI Z223.1/NFPA54 (current edition). The Uniform Mechanical Code - (current edition), and local Building Officials for the options allowed in obtaining an effective bedroom volume of unconfined space. These models (natural gas and propane) can be installed in a bedroom (in Canada) if a thermostat (Model WH-STAT) is installed with the unit. Consult local code authorities. Detailed installation instructions for Model WH-STAT are included with the kit. High Altitude Installations U.L. Listed gas fireplaces are tested and approved for elevations from 0 to 2,000 feet in the U.S.A. and from 0 to 4,500 feet in Canada. When installing this fireplace at an elevation above 2,000 feet (in the United States), it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input should be reduced four percent (4%) for each 1,000 feet above sea level, unless the heating value of the gas has been reduced, in which case this general rule will not apply. To identify the proper orifice size, check with the local gas utility. When installing this fireplace at an elevation between 2,000 and 4,500 feet (in Canada), the input rating must be reduced by ten percent (10%). When installing this fireplace at an elevation above 4,500 feet (in Canada), check with local authorities. Consult your local gas utility for assistance in determining the proper orifice for your location. Heat-N-Glo Quality Systems registered by SGS ICS 8

2Getting Started Introducing the Heat-N-Glo Gas Fireplaces Heat-N-Glo B-type vent gas fireplaces are designed to operate with all exhaust gases expelled to the outside of the building. The information contained in this Installers Guide, unless noted otherwise, applies to all models and gas control systems. Gas fireplace diagrams, including the dimensions, are shown in this section. Pre-install Preparation This gas fireplace and its components are tested and safe when installed in accordance with this Installers Guide. Report to your dealer any parts damaged in shipment, particularly the condition of the glass. Do not install any unit with damaged, incomplete, or substitute parts. The vent system components, gas logs and trim doors are shipped in separate packages. Log installation instructions are provided in the manual bag assembly shipped with the unit. Read all of the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety and benefit. Failure to follow these instructions will void the owner s warranty and may present a fire hazard. The Heat-N-Glo Warranty will be voided by, and Heat-N-Glo disclaims any responsibility for, the following actions: Installation of any damaged fireplace or vent system component. Modification of the fireplace or direct vent system. Installation other than as instructed by Heat-N-Glo. Improper positioning of the gas logs or the glass door. Installation and/or use of any component part not manufactured and approved by Heat-N-Glo, not withstanding any independent testing laboratory or other party approval of such component part or accessory. ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE HAZARD. When planning a fireplace installation, it s necessary to determine: Where the unit is to be installed. The vent system configuration to be used. Gas supply piping. Electrical wiring. Framing and finishing details. Whether optional accessories devices such as a fan, wall switch, or remote control are desired. If the fireplace is to be installed on carpeting or tile, or on any combustible material other than wood flooring, the fireplace should be installed on a metal or wood panel that extends the full width and depth of the fireplace. 9

VENT COLLARS STANDOFFS HOOD BOTTOM GRILLE COVER RATING PLATES & LABELS OUTSIDE AIR GAS ACCESS GAS CONTROLS ELECTRICAL ACCESS Figure 1. Diagram of the 7000TV and 6000TVB 10

Minimum Clearances from the Fireplace to Combustible Materials 3Installing the Fireplace Step 1. Locating the Fireplace The diagram below shows space and clearance requirements for locating a fireplace within a room. Inches mm Glass Front... 36... 914 Floor... 0... 0 Rear...1/2... 13 Sides...1/2... 13 Top... 3 1/2... 89 Ceiling*... 31... 787 * The clearance to the ceiling is measured from the top of the unit, excluding the standoffs (see Figure 13). Minimum Clearances from the B-Type Vent Pipe to Combustible Materials is 1 inch (25mm) all around the pipe. Step 2. Framing the Fireplace Fireplace framing can be built before or after the fireplace is set in place. Framing should be positioned to accommodate wall coverings and fireplace facing material. The diagram below shows framing reference dimensions. CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING. A B C D E 42 22 36 51 72 Framing should be constructed of 2 X 4 lumber or heavier. Figure 2. Fireplace Dimensions, Locations, and Space Requirements Clearance Requirements The top, back, and sides of the fireplace are defined by stand-offs. The minimum clearance to a perpendicular wall extending past the face of the fireplace is one inch (25 mm). The back of the fireplace may be recessed 21 1/2 inches (546 mm) into combustible construction. The minimum clearance from the top face of the fireplace to combustible finishing materials such as drywall, is one inch (25mm). WARNING: To ensure proper clearances the front framing header must be installed on its narrow edge and to the front of the frame. The distance from the unit to combustible construction is to be measured from the unit outer wrap surface to the combustible construction, NOT from the screw heads that secure the unit together. A. 42 B. 38 1/2 C. 22 Figure 3. Framing Dimensions 11

Step 3. Negative Pressure Make-up Air Negative Pressure warning: When negative pressure is present, an atmospherically vented fireplace (with a draft hood) may not function properly and it may down draft. In the case of a gas appliance, spillage of the combustion gases may occur. This may create a dangerous carbon monoxide situation in the house. The causes of negative pressure to a house can include the following: Stack effect in the building. Exhaust only appliances (mechanically and atmospherically vented). Inadequate make-up air (which is increasingly more prevalent in new construction). NOTE: This fireplace will operate correctly only if adequate ventilation is provided to allow proper draft to the fireplace system. Heat-N-Glo assumes no responsibility for the improper performance of the fireplace system caused by inadequate draft due to environmental conditions, down drafts, tight sealing construction of the structure, or mechanical exhausting devices which create a negative air pressure within the structure where the fireplace is located. It is recommended that all natural venting non-air tight gas fireplaces have outside air connected to them. It is also recommended that the building be mechanically or passively balanced to allow atmospherically vented appliances, such as top vented gas fireplaces with draft hoods, to draft properly. If the home experiences negative pressure or is likely to experience negative pressure, connection to an outside air source is mandatory. Installing Optional Outside Make-up Air: This unit is equipped to accept outside air. By using outside make-up air, the amount of room air used for combustion will be reduced. It is recommended that an AK-TV air kit be used with this appliance. WARNING: IN A NEGATIVE PRESSURE CON- DITION (LIKELY TO OCCUR IN NEW HOMES THAT DO NOT HAVE ADEQUATE MAKE-UP AIR) THE OUTSIDE AIR KIT MUST BE IN- STALLED TO OBTAIN PROPER PERFOR- MANCE AND TO HELP PREVENT SPILLAGE OF COMBUSTION GASES. A 4-inch side collar/damper (found in AK-TV Kit) must be installed on the fireplace by attaching the side collar to the outer wrap of the fireplace at the right-hand rear corner using sheetmetal screws. See Figure 4. Attach one end of a 4- inch flexible air duct (not provided in the AK-TV Kit) to the side collar and the other end of the duct to the make-up air termination cap. Use plastic tie straps to secure the ends of the flex duct to each collar. Air Damper Before lighting the burner, open the damper. Close the damper when the burner is off. Detailed installation instructions for Model AK-TV Outside Air kit are found in the kit. Figure 4. Make-up Air 12

Step 4. Installing the Vent System A. Vent System Approvals Models 7000TV and 6000TVB are approved to use 6-inch (152mm) diameter B-type vent. B-type vent must be used when the vent system is within combustible construction. These models may also use single wall rigid or flexible gas vent IF and ONLY IF the vent system is installed within non-combustible construction such as a masonry chimney. The same diameter noted above for B-type vent must be used for single-wall vent. See Figure 5. For B-type vent the clearance to combustibles is 1-inch. Follow vent manufacturers REQUIRED clearances. The flame and ember appearance may vary based on the type of fuel burned and the venting configuration used. B. System Components. Vent System Configuration RISE TO RUN RATIO = 2:1 MAXIMUM TOTAL HORIZONTAL RUN = 15 FT. MINIMUM TOTAL VERTICAL RISE = 9 FT. MAXIMUM NO. Of ELBOWS: 2-90 o or 4-45 o Plan and install the vent system using the parameters shown above. WARNING: YOU MUST NOT EXCEED THESE PARAMETERS. Connect a B-Type vent component to the flue outlet collar. Look at the vent pipe through the holes in the 10 5/8 ring to check that the vent pipe is attached. NOTE: It is always better to first attach a straight section of vent to the unit before attaching an elbow. Avoid using elbows in the vent system if possible. A 90-degree elbow can be attached directly to the unit. If it is, it can be followed by a MAXIMUM 15-feet horizontal run, a second 90-degree elbow ending in a minimum 30 foot vertical. A minimum of 9 foot vertical rise ending in a listed termination cap is required for the unit. Continue to add vent components, until the vent run is completed. WARNING: YOU MUST NOT EXCEED A TOTAL MAXIMUM HORIZONTAL RUN OF 15 FEET FOR THE ENTIRE VENT SYSTEM. B-TYPE VENT MINIMUM VERTICAL RISE = 9FT MAXIMUM HORIZONTAL RUN = 15FT V:H = 2:1 Figure 5. Vent System Attachment LISTED TERMINATION CAP LISTED SINGLE-WALL GAS VENT NON-COMBUSTIBLE CONSTRUCTION NOTE: The vent termination must be in a vertical position and the termination cap must be listed for the vent pipe used. Consult Local Building Code Officials and Codes for proper vent system installations. WARNING: THIS GAS FIREPLACE MUST NEV- ER BE VENTED BY CONNECTING TO A CHIM- NEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. 13

C. Bedroom Installation in Canada This model MUST NOT be vented into a vent system installed exterior to a building. The part of the vent system above the roof line can be exterior to the building. D. Vent Termination WARNING: MAJOR U.S. BUILDING CODES SPECIFY MINIMUM CHIMNEY AND/OR VENT HEIGHT ABOVE THE ROOF TOP. THESE MIN- IMUM HEIGHTS ARE NECESSARY IN THE IN- TEREST OF SAFETY. FIGURE 6 AND TABLE SHOW MINIMUM HEIGHTS, PROVIDED THE TERMINATION CAP IS AT LEAST 8-FEET FROM A VERTICAL WALL. Step 5. Positioning, Leveling, and Securing the Fireplace To properly position, level, and secure the fireplace: Place the fireplace into position (see Figure 7). Level the fireplace from side to side and from front to back. Shim the fireplace with non-combustible material, such as sheet metal, as necessary. Secure the fireplace to the framing by nailing or screwing. WARNING: To ensure proper clearances the front framing header must be installed on its narrow edge and to the front of the frame. TERMINATION CAP LOWEST DISCHARGE OPENING 12 X ROOF PITCH IS X/ 12 H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Figure 7. Proper Positioning, Leveling, and Securing of a Fireplace ROOF PITCH H (MIN.) FT. FLAT TO 6/12 1.0 6/12 TO 7/12 1.25 OVER 7/12 TO 8/12 1.5 OVER 8/12 TO 9/12 2.0 OVER 9/12 TO 10/12 2.5 OVER 10/12 TO 11/12 3.25 OVER 11/12 TO 12/12 4.0 OVER 12/12 TO 14/12 5.0 OVER 14/12 TO 16/12 6.0 OVER 16/12 TO 18/12 7.0 OVER 18/12 TO 20/12 7.5 OVER 20/12 TO 21/12 8.0 Figure 6. Vent Termination Step 6. The Gas Control Systems WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL. Two types of gas control systems are used with these models: Standing Pilot Ignition and Direct Spark Ignition (DSI). Standing Pilot Ignition System This system includes millivolt control valve, standing pilot, thermopile/thermocouple flame sensor, and piezo ignitor. WARNING: 110-120 VAC MUST NEVER BE CONNECTED TO A CONTROL VALVE IN A MILLIVOLT SYSTEM. Direct Spark Ignition (DSI) System The DSI system includes a 120V control valve, electronic module, and spark ignitor/flame sensor. WARNING: CONTINUOUS 110-120 VAC SER- VICE MUST BE WIRED TO THE FIREPLACE JUNCTION BOX IN A DSI SYSTEM. 14

STANDING PILOT Open the fireplace lower grille, insert the gas supply line through the gas line hole, and connect it to the shut-off valve. When attaching the pipe, support the control so that the lines are not bent or torn. After the gas line installation is complete, use a soap solution to carefully check all gas connections for leaks. WARNING: DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS. NOTE: FLAMES TOO CLOSE TO THE CERAMIC INSULATORS CAN CAUSE NUISANCE LOCKOUTS AND ELECTRODE FAILURE. DSI IGNITION IGNITOR 3/8 (10mm) Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing. At the gas line access hole the gap between the supply piping and gas access hole can be plugged with noncombustible insulation to prevent cold air infiltration. CERAMIC INSULATOR 6000TVB 1/4" (6mm) USE A WRENCH ON SHUT-OFF VALVE WHEN TIGHTENING GAS LINE MANUAL SHUT-OFF VALVE IGNITOR GAS VALVE 7000TV FLEX CONNECTOR 1/4 (6.4mm) Figure 8. Gas Control Systems Step 7. The Gas Supply Line NOTE: Have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or licensed as required by the locality. NOTE: Before the first firing of the fireplace, the gas supply line should be purged of any trapped air. NOTE: Consult local building codes to properly size the gas supply line leading to the 1/2 inch (13 mm) hook-up at the unit. This gas fireplace is designed to accept a 1/2 inch (13 mm) gas supply line. To install the gas supply line: A listed (and State of Massachusetts approved) 1/2 inch (13mm) tee-handle manual shut-off valve and a listed flexible gas connector are connected to the 1/2 inch (13mm) inlet of the control valve. NOTE: If substituting for these components, please consult local codes for compliance. Locate the gas line access hole in the outer casing of the fireplace. The gas line may be run from either side of the fireplace provided the hole in the outer wrap does not exceed 2 in diameter and it does not penetrate the actual firebox. 15 Figure 9. Gas Supply Line Step 8. Gas Pressure Requirements Pressure requirements for Heat-N-Glo gas fireplaces are shown in the table below. Pressure Natural Gas Propane Minimum 5.0 inches 11.0 inches Inlet Pressure w.c. w.c. Maximum Inlet 14.0 inches 14.0 inches Gas Pressure w.c. w.c. Manifold 3.5 inches 10.0 inches Pressure w.c. w.c. A one-eighth (1/8) inch (3 mm) N.P.T. plugged tapping is provided on the inlet and outlet side of the gas control for a test gauge connection to measure the manifold pressure. The fireplace and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of one-half (1/2) psig (3.5 kpa). The fireplace must be isolated from the gas supply piping system by closing its individual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than one-half (1/2) psig (3.5 kpa).

Figure 10. Standing Pilot Ignition Wiring Diagram Step 9. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE- VENT ACCIDENTAL FIREPLACE OPERATION. For Standing Pilot Ignition Wiring Appliance Requirements This appliance DOES NOT require 110-120 VAC to operate. WARNING: DO NOT CONNECT 110-120 VAC TO THE GAS CONTROL VALVE OR THE AP- PLIANCE WILL MALFUNCTION AND THE VALVE WILL BE DESTROYED. Optional Accessories Optional fan and remote control kits require that 110-120 VAC be wired to the factory installed junction box before the fireplace is permanently installed. NOTE: When installing a blower, remove the glass and remove the two screws holding the air chute in place. Remove the air chute and install the blower. YOU MUST REPLACE THE AIR CHUTE AFTER INSTALLATION Remote Wall Switch Position the remote wall switch in the desired position on a wall. Run a maximum of 25 feet (7.8 m) or less length of 18 A.W.G. minimum wire and connect it to the fireplace ON/ OFF switch pigtails. WARNING: DO NOT CONNECT 110-120 VAC TO THE REMOTE WALL SWITCH OR THE CONTROL VALVE WILL BE DESTROYED. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC- TION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING. FAN WIRING DIAGRAM VARIABLE SPEED CONTROL JUNCTION BOX NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105 DEGREE C RATED WIRE. BLOWER RECEPTACLE WHT WHT GROUND TEMPERATURE SENSOR SWITCH GRN BLOWER WHT 110-120 VAC Figure 11. Fan Wiring Diagram 16

For Direct Spark Ignition (DSI) Wiring Appliance Requirements This appliance requires that 110-120 VAC be wired to the junction box included in the manual bag assembly. Maintain correct polarity when wiring the junction box. The junction box is installed by sliding one tab of the box through the slot on the lower right side of the outer wrap and driving a screw through the other tab into the pilot hole on the outer wrap. Optional Accessories Optional fan and remote control kits require that 110-120 VAC be wired to the fireplace junction box. Remote Wall Switch Position the remote wall switch in the desired position on a wall. Run a maximum of 25 feet (7.8 m) or less of 16 A.W.G. minimum wire and connect it to the fireplace ON/OFF switch pigtails. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC- TION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERA- TION. VERIFY PROPER OPERATION AFTER SERVICING. Figure 12. Direct Spark Ignition (DSI) Wiring Diagram 17

Step 10. Finishing Figure 13 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace. See Figures 2 and 3 for other fireplace clearances. Only non-combustible materials may be used to cover the black fireplace front. WARNING: WHEN FINISHING THE FIREPLACE, NEVER OBSTRUCT OR MODIFY THE AIR IN- LET/OUTLET GRILLES IN ANY MANNER. Figure 13. Minimum Vertical and Maximum Horizontal Dimensions of Combustibles above Fireplace CAUTION: IF JOINTS BETWEEN THE FINISHED WALLS AND THE FIREPLACE SURROUND (TOP AND SIDES) ARE SEALED, A 300 F. MINIMUM SEALANT MATE- RIAL MUST BE USED. THESE JOINTS ARE NOT RE- QUIRED TO BE SEALED. ONLY NON-COMBUSTIBLE MATERIAL (USING 300 F. MINIMUM ADHESIVE, IF NEEDED) CAN BE APPLIED AS FACING TO THE FIRE- PLACE SURROUND. SEE THE DIAGRAM BELOW. 12" TOP FRONT EDGE OF FIREPLACE 12 CEILING 31 Step 11. Installing Trim, Logs, and Ember Material Installing the Trim Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace, but MUST NEVER overlap onto the front face. The joints between the finished wall and the fireplace top and sides can only be sealed with a 300 F (149 C) minimum sealant. WARNING: WHEN FINISHING THE FIREPLACE, NEVER OBSTRUCT OR MODIFY THE AIR INLET/ OUTLET GRILLES IN ANY MANNER. Install optional marble and brass trim surround kits as desired. Marble, brass, brick, tile, or other non-combustible materials can be used to cover up the gap between the sheet rock and the fireplace. Do not obstruct or modify the air inlet/outlet grilles. When overlapping on both sides, leave enough space so that the bottom grille can be lowered and the trim door removed. Positioning the Logs If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately, refer to the instructions that accompany the logs. Save the log instructions with this manual. If sooting occurs, the logs might need to be repositioned slightly to avoid excessive flame impingement. Placing the Ember Material Ember material is shipped with this gas fireplace. The bag labeled Glowing Ember (050-721) is standard glowing ember material. To place the ember material: Pull the four glass latches out of the groove on the glass frame. Remove glass door from the unit (see Figure 30). Place dime size pieces of ember material about 1/2 inch apart near port holes in burner top. Do NOT press embers into burner ports. Cover the top of the burner with a single layer of ember material. For best performance do NOT place embers on the ports at the rear of the burner. Save the remaining ember materials for use during fireplace servicing. The bag of embers provided is sufficient for 3 to 5 applications. Replace the glass door and a front trim door on the unit. Pull out and latch the glass clips into the groove on the glass frame. Figure 14. Sealant Material Hearth Extensions A hearth extension may be desirable for aesthetic reasons. However, ANSI or CAN/CGA testing standards do not require hearth extensions for gas fireplace appliances. 18

Step 12. Before Lighting the Fireplace Figure 15. Glass Assembly Glass Specifications: 24 1/2 X 35 1/2 TEMPERED 7000TV 6000TVB Before lighting the fireplace, be sure to do the following: Remove all paperwork from underneath the fireplace. Review safety warnings and cautions Read the Safety and Warning Information section at the beginning of this Installers Guide. Double-check for gas leaks Before lighting the fireplace, double-check the unit for possible gas leaks. Double-check vent terminations and front grilles for obstructions. Before lighting the fireplace, double-check the unit for possible obstructions that could be blocking the vent terminations or the front grilles. Double-check for faulty components Any component that is found to be faulty MUST BE replaced with an approved component. Tampering with the fireplace components is DANGEROUS and voids all warranties. A small amount of air will be in the gas supply lines. When first lighting the fireplace, it will take a few minutes for the lines to purge themselves of this air. Once the purging is complete, the fireplace will light and will operate normally. Subsequent lightings of the fireplace will not require this purging of air from the gas supply lines, unless the gas valve has been turned to the OFF position, in which case the air would have to be purged. NOTE: The fireplace should be run for 8 hours on the initial start-up. This will help to cure the chemicals used in the paint and logs. Step 13. Lighting the Fireplace You ve reviewed all safety warnings, you ve checked the fireplace for gas leaks, you know the vent system is unobstructed, and you ve checked for faulty components. Now you re ready to light the fireplace. Figure 16. Placement of the Ember Material CAUTION: IT IS STRONGLY RECOMMENDED THAT TRIM DOORS WITH OPTIONAL MESH SCREENS BE IN- STALLED ON PROPANE MODELS. WARNING: PLEASE REFER TO THE USER S MANUAL FOR ALL CAUTIONS, SAFETY, AND WARNING INFORMATION PERTAINING TO THE LIGHTING AND OPERATION OF THE FIREPLACE. After the Installation LEAVE THIS INSTALLATION MANUAL WITH THE APPLIANCE FOR FUTURE REFERENCE. 19

4Maintaining and Servicing Your Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and maintenance will depend on use and the type of installation, you should have a qualified service technician perform an appliance check-up at the beginning of each heating season. See the table below for specific guidelines regarding each fireplace maintenance task. IMPORTANT: TURN OFF THE GAS BEFORE SERVICING YOUR FIREPLACE. Replacing old ember material Frequency: Once annually, during the checkup. By: Qualified service technician. Task: Brush away loose ember material near the burner. Replace old ember material with new dime-size and shape pieces of Golden Ember (DE-93) and Glowing Ember (050-721). New ember material should be placed alternately on top of the burner - a layer of Golden Ember, a layer of Glowing Ember, and so on. Save the remaining ember material and repeat this procedure at your next servicing. For more information, see Placing Ember Material. 7000TV 6000TVB Cleaning Burner and Controls Frequency: Once annually. By: Qualified service technician. Task: Brush or vacuum the control compartment, fireplace logs and burner areas surrounding the logs. Checking Flame Patterns, Flame Height Frequency: Periodically. By: Qualified service technician/home owner. Task: Make a visual check of your fireplace s flame patterns. Make sure the flames are steady - not lifting or floating. See Figure 17. The flame sensor (DSI) or thermopile/ thermocouple (standing pilot) tips should be covered with flame. See Figure 8. Figure 17. Burner Flame Patterns MAKE SURE THE FLAMES ARE STEADY NOT LIFTING OR FLOATING. Checking Vent System Frequency: Before initial use and at least annually thereafter, more frequently if possible. By: Qualified service technician/home owner. Task: Inspect the external vent cap on a regular basis to ensure that no debris is interfering with the flow of air. Inspect entire vent system for proper function. Cleaning Glass Door Frequency: As necessary By: Home owner. Task: Clean as necessary, particularly after adding new ember (flame colorant) material. Film deposits on the inside of the glass door should be cleaned off using a household glass cleaner. NOTE: DO NOT handle or attempt to clean the door when it is hot and DO NOT use abrasive cleaners. 20