NicheVision Sole Source Justification STRmix Mixture Interpretation Software Justification for Non-Competitive Procurement

Similar documents
TrueAllele Technology Computer interpretation of DNA evidence

Virginia TrueAllele Validation Study: Casework Comparison. One person, one genotype. DNA data. Cybergenetics

Standard ECMA th Edition - December Declared Noise Emission Values of Information Technology and Telecommunications Equipment

Probabilis(c So9ware Workshop September 29, DNA Mixtures: A Separa(on Problem. Cybergene(cs TrueAllele Casework. Cybergene(cs

Reported Fires in High-Rise Structures in Selected Occupancies with and without Automatic Extinguishing Systems by Extent of Smoke Damage

Weigh In Motion (WIM) Wheel Impact Load Detector (WILD)

Lesson Objectives At the end of this lesson you should be able to

IN THE SUPERIOR COURT OF DECATUR COUNTY STATE OF GEORGIA ) ) ) ORDER. COMES NOW This Court, having read and considered all motions, responses, all

IN THE SUPERIOR COURT OF COWETA COUNTY STATE OF GEORGIA V. CASE NO CR-618 < ORDER

TESTS OF ADSIL COATING

White Paper: Video/Audio Analysis Technology. hanwhasecurity.com

Demand-Controlled Ventilation For Commercial Kitchens

Structure Fires in Hotels and Motels

EXECUTIVE SUMMARY Greater Milwaukee Watersheds Stormwater Report. Background and Significance

VISEUM UK PRESENTATION

Estimating the Level of Free Riders in the Refrigerator Buy-Back Program

Trait: characteristics to be passed from parent to offspring. Passed on from parent to offspring by the blood, in bloodlines.

Introducing New 96-Well Fast Plate Adapters for Applied Biosystems Capillary Electrophoresis Systems

U.S. Fire Department Profile 2015

DR Series Appliance Cleaner Best Practices. Technical Whitepaper

C-NRPP Quality Assurance Guidance for Radon Test Devices

TEXAS CHAPTER AMERICAN SOCIETY OF LANDSCAPE ARCHITECTS 2019 PROFESSIONAL AWARDS GUIDELINES

False Alarm Analysis of the CATM-CFAR in Presence of Clutter Edge

Supplementary Data. Chromosome 16q22 variants associated with low-density lipoprotein cholesterol levels correlate with

Marker-assisted backcrossing

Architectural and Engineering Specification for a. Flash / Flare

Thick-Film Heater achieves Superior Performance in Thermal Response, Uniformity and Efficiency.

[ [ ADMIN PANEL USER GUIDE

IN THE CIRCUIT COURT OF THE FIFTEENTH JUDICIAL CIRCUIT, CRIMINAL DIVISION IN AND FOR PALM BEACH COUNTY, FLORIDA CASE NO. 2015CF009320AMB DIVISION: "X"

SYNERGY IN LEAK DETECTION: COMBINING LEAK DETECTION TECHNOLOGIES THAT USE DIFFERENT PHYSICAL PRINCIPLES

Architectural and Engineering Specification for a Real-Time Locating System Flare

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

SUWANNEE RIVER WATER MANAGEMENT DISTRICT REQUEST FOR BID NO. 15/16-003AO FIRE ALARM SYSTEM INSTALLATION AND MONITORING.

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

DeltaV Analyze. Introduction. Benefits. Continuous automated DeltaV System alarm system performance monitoring

USER APPROVAL OF SAFETY INSTRUMENTED SYSTEM DEVICES

Evaluation of Strobe Lights in Red Lens of Traffic Signals

The European Commission s science and knowledge service. Building on core components of Technical Reachback

Implementing a Reliable Leak Detection System on a Crude Oil Pipeline

1 Introduction - The rating level. 3 Subjective or objective analysis? 2 Determination of the adjustment for annoying tones

garden\garden: A Comparison in Santa Monica

Micrel Case Study: Reducing Costs for Industrial Gas Cylinders Management 14 January 2008

Official Journal of the European Union. (Non-legislative acts) REGULATIONS

Improved Lifecycle Management for BI. David Brockington SAP Business Objects, Product Management June, 2009

Smart Defrost Control for Refrigeration System

U.S. FIRE DEPARTMENT PROFILE THROUGH 2009

Functional Safety: the Next Edition of IEC 61511

Mendel s Genetics. Johann Gregor Mendel. Born 1822 Occupations: -beekeeper Mendel entered Augustinian Abbey of St Thomas in Brno, Austria

FI-DL. SpectraMax Paradigm Fluorescence Intensity Dual Label (FI-DL) (MultiTox-Fluor) Detection Cartridge. User Guide

City of Norwich Policy Regarding Monuments on City Property

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Introduction to Horticulture, 5th Edition 2009, (Schroeder et al.) Correlated to: North Carolina VoCATS Course Blueprint - Horticulture I

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

Sensor Placement Algorithm for Rapid Theatre Assessment (SPARTA)

Conductive Heating Technologies for Medical Diagnostic Equipment. Russell Strehlow, Manager of Research and Development, Minco

Abu Dhabi Conformity Assessment Scheme for Fire Pumps

Remote Monitoring of Offshore Structures using Acoustic Emission.

Datasheet Crowd Management

propagation whose distinguishable characters are of agricultural significance.

Polaris Sensor Technologies, Inc. Visible - Limited Detection Thermal - No Detection Polarization - Robust Detection etherm - Ultimate Detection

Universal modular MWD platform adapted for your needs

OREM CITY OREM UTOPIA SURVEY 2018

AN ANALYSIS OF THE PERFORMANCE OF RESIDENTIAL SMOKE DETECTION TECHNOLOGIES UTILIZING THE CONCEPT OF RELATIVE TIME

Fiber Optic Cable Fence Disturbance Sensor

Measure Lifetime Derived from a Field Study of Age at Replacement

ACHIEVEMENT LEVEL DESCRIPTORS

Real Time Pipeline Leak Detection on Shell s North Western Ethylene Pipeline

Strategic Environmental Assessment Screening Report. Dublin Port Masterplan Review 2017

LAUDA TecInfo Viscometry No 3

Presented by: Remy Norbert DUHUZE Director/ER&PC REMA

Communication and Coordination Failures in the Process Industries

HazLoc Essential Guides:

Segment design & and Bus Diagnostics

Recognizing excellence in landscape architectural design, planning and analysis, communications, and research.

Oracle Communications Performance Intelligence Center

Avigilon Control Center 5 System Integration Guide

D Implementation of a DEMO system related to Smart Fault Management in LV network (normal/storm conditions)

CERBERUS: A NEW MODEL TO ESTIMATE SIZE AND SPREAD FOR FIRES IN TUNNELS WITH LONGITUDINAL VENTILATION

MIRA Black Start User Guide. Monitoring Analytics, LLC. Version 1.0: April 18, Monitoring Analytics

The New EMC Directive 2004/108/EC

AGRICULTURAL RESEARCH FOUNDATION FINAL REPORT FUNDING CYCLE

New requirements for IEC best practice compliance

Alarm Hot Backup Manager can use InTouch, Galaxy, or Galaxy_ as alarm providers when configuring an alarm Hot Backup Pair.

Glenborough at Easton Land Use Master Plan

Welcome. Challenges in Multi-Site Environmental Monitoring. Balancing Standardization and Localization for Costs, Risks, and Best Fit

Temperature Data Logging

How the People Counter Works. Enhanced Safety, Security and Building Automation, and Improved Marketing Intelligence. 3D MLI Sensor Technology

Benefits of Enhanced Event Analysis in. Mark Miller

1.1 DESCRIPTION A. The purpose of this section is to specify Division 23 responsibilities in the commissioning (Cx) process.

SCS311 / SCS317 Installation Instructions

Project Leaders Curt R. Rom University of Arkansas Dept of Horticulture 316 PTSC, Fayetteville AR

IEC PRODUCT APPROVALS VEERING OFF COURSE

Davis Soil Moisture and Temperature Station Protocol

Course Catalogue. An evolution of excellence. Welcome to the UTC Fire and Security EMEA Lenel OnGuard Training Catalogue for Value Added Resellers

* A person would be visible from a greater distance at nighttime than during daytime. At nighttime their heat / IR signature would be greater than

Household Appliance Replacement Program - Impact and Tradeoffs

Sensor Evaluation for Human Presence Detection

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

Airbus 380 Evacuation Demonstration

Supervisor Standard Edition

Transcription:

NicheVision Sole Source Justification STRmix Mixture Interpretation Software Justification for Non-Competitive Procurement Award Number: Is the award open? Type of Procurement Does the budget include purchases with a single vendor that totals over $ 100,000? Are there vendors in the budget which may cumulatively reach $ look? 20 13-DN-BX-0074 Yes Non-competitive bid (Sole Source) Yes Yes Brief description The objective of the Bureau of Forensic Services Laboratories (CA 001) funded by award number 20 13-DN-BX-0074 is to handle, screen, and analyze backlogged forensic DNA casework and databank samples and to improve DNA laboratory infrastructure and analysis capacity so that forensic DNA samples can be processed efficiently and cost effectively, and so that future backlogs can be prevented. One specific goal is improving mixture interpretation capabilities within the casework section. CA 001 has developed rapidprocessing programs for sexual assault evidence that require assault-to-codis search turnaround times ofless than a month, and sometimes as short as two weeks. Manual mixture interpretation can be a laborious, time consuming process that is not amenable to such rapid processing. To that end, CA 001 previously implemented an in-house mixture interpretation tool that applies our current binary, threshold based protocol to two-person mixtures. The field offorensic DNA testing in the United States, however, is starting to move beyond binary approaches, and complex mixtures with more than two contributors are an everpresent challenge. This sole source relates to the purchase of mixture interpretation software that will integrate well into the current suite of kits, instrumentation, and data processing software already in use at CA 001 and familiar to our criminalists. The CA 001 Bureau of Forensic Services has evaluated two mixture interpretation software packages, TrueAllele and STRmix. Since the beginning of our evaluation oftrueallele, the STRmix software has become commercially available. STRmix, developed by ESR and Award No. 20 I 3-0N-8X-0074 Niche Vision So le Source 08/25 /2014 Page I of7 epic.org EPIC-16-02-02-CalDOJ-FOIA-20160219-Procurement-Justification-STRmix 000001

Explanation of dollar amounts of the sole source request: distributed in the United States by NicheVision, uses the same fundamental statistical concepts as TrueAllele. After extensive testing over the course of a year, STRmix was found to be a better fit to our needs and goals. Under this project, the laboratory will make expenditures with Niche Vision in the equipment, training, and maintenance categories. The contracts/purchases are anticipated to total over $100,000. NicheVision is the only vendor that can provide the required items and services in order for the laboratory to meet project goals and continue to be in compliance with the guidelines defined in the grant solicitation. 2013 Budget # Define Instrum ent or Equipment Item Cost per Unit line No Units Unit 430 STRmix user licenses $ 15,000.00 20 each 2013 Bud get # Define Instrument or Equipment Item Cost per Unit Line No Units Unit 3 days of training 432 STRmix Training $ 45,000.00 1 for up to 20 people 20 13 Budget # Defi ne Instrument or Equi pment Item Cost per Unit Line No Units Unit 80 hours of 431 STRmix Support package $ 16,000.00 1 software and scientific support Vendor Niche Vision Vendor Niche Vision Vendor Niche Vision Cost $300,000.00 Cost $45,000.00 Cost $16,000.00 Explanation of why it is necessary to purchase noncompetitively. Award No. 20 13-DN-8X-0074 Niche Vi sion Sale Source 08/25/20 14 As with any crime laboratory, the Bureau of Forensic Services finds that many of the samples we test consist of complex mixtures (e.g., degraded and/or with more than two contributors.) The previous decision to pursue TrueAlIele Casework, and not other available software, as an interpretation assistant was made with the hope that such challenging samples could be interpreted with precision and sensitivity. However, after comparing TrueAlIele to STRmix, we determined that STRmix was better suited to our goals. Three key factors in this decision are I) increased sensitivity, especially with degraded samples; 2) increased precision when maintaining a set number of runs; and 3) decreased Page 2 of7 epic.org EPIC-16-02-02-CalDOJ-FOIA-20160219-Procurement-Justification-STRmix 000002

interpretation time due to reduced run time and fewer re-runs. I) Increased sensitivity, especially with degraded samples Degraded samples are a common observation in forensic DNA testing. Especially challenging instances involve what is sometimes referred to as differential degradation where the different contributors' DNA are each degraded to a different extent. This can happen when the biological material consists of different tissue types and/or the various contributors' biological material was deposited at different times. In some circumstances, the result can be a DNA profile in which an individual might be a majority contributor to the results in one molecular weight range, but a minority contributor in another molecular weight range. This phenomenon can be difficult or impossible for an examiner to discern without the assumption of one or more of the contributors' genotypes. Both STRmix and TrueAllele can incorporate an assessment of degradation and differential degradation into their process. For STRmix, it is automatic. For TrueAllele, it is an optional setting. Testing a series of two-person mixtures with differential degradation as described above, STRmix was clearly better at detecting and adjusting for this. STRmix had 0 Type I errors, here defined as likelihood ratios (LR) below 1.0, while TrueAllele had Type I errors in 18% of the contributor-to-mixture comparisons. Additionally, a number of TrueAllele interpretations did not include the true contributors' genotypes. This was masked in the reporting statistic by TrueAllele's minimum locus LR threshold of 0.01. Overriding the LR threshold, Type I errors increased to 60% with 56% of the comparisons being complete exclusions (LR = 0.) Similar results were observed for a 3-person, 6:3:1 mixture with the middle contributor degraded. Type I errors occurred in 3.7% of the STRmix comparisons, the one error being a complete exclusion for the degraded donor. TrueAllele had no Type I errors under the standard settings, but 56% of the comparisons were Type I errors (all complete exclusions) when overriding the LR threshold. Our current process has been shown to be relatively robust and effective for interpreting 2-person mixtures, albeit without the benefits that come with a probabilistic assessment of peak height ratios, stutter, and drop-out. However, we remain severely limited in how we can address 3-person mixtures. For the validation at hand, multiple sets of3-person mixtures were created using four different ratios (l: I: I, 8: I: I, 6:3: I, and 4.5:4.5: 1) at three different total template quantities (1.5 ng, 0.75 ng, and 0.375 ng.) Replicate interpretations were performed on each mixture using STRmix and Award No. 20 I 3-DN-8X-0074 Niche Vision Sale Source 08/25 /2014 Page 3 of? epic.org EPIC-16-02-02-CalDOJ-FOIA-20160219-Procurement-Justification-STRmix 000003

TrueAllele, with the goal of comparing precision and sensitivity. In this study, 3.4% of the overall STRmix comparisons were Type [ errors. The two interpretations that lead to complete exclusions were due to a limitation in the Java programming environment, and a clear diagnostic was discovered with which to evaluate and prevent that issue. The remaining Type I errors occurred in the low template samples (0.375 ng amplifications), primarily with minor donors that contributed approximately 6 diploid cells worth of DNA to the mixture. 5.1% of TrueAllele comparisons were Type I errors under standard settings, which is similar to the levels observed for STRmix. However, overriding the LR threshold increased TrueAllele Type T errors to 9.2%, with 5.6% of comparisons being complete exclusions. 2) Increased precision Randomness is one of the hallmarks of the Markov Chain Monte Carlo (MCMC) process at the heart of both STRmix and TrueAllele. Because of that, it is expected that successive MCMC runs using the same starting profile will give somewhat different results. The magnitude of these differences, however, is ideally kept as low as possible. Comparing 10g(LR) values between replicates, precision was measured as the proportion of replicate pairs that differed by less than 1 log unit (i.e., a factor of 10 difference in the LRs.) The data from the differential degradation and 3-person mixture studies were used for this purpose. With the differential degradation samples, 1.6% of STRmix pairs differed by more than one log unit, while 46% of TrueAllele pairs differed by more than one log unit. Overriding TrueAllele's LR threshold decreased this to 38%, but that was due at least in part to replicates that were both now complete exclusions (i.e., both replicates were LR = 0.) 3) Decreased interpretation time due to reduced run time and fewer re-runs. Both STRmix and TrueAllele were tested using settings designated as appropriate for challenging samples, under the theory that an evidence sample may appear to be simpler than it truly is. With these settings, TrueAllele required significantly longer analysis times when compared to STRmix. The mixture interpretation phase for a 2-person mixture using TrueAllele typically required an overnight analysis (8+ hours), while STRmix would be complete within minutes. For 3-person mixtures, TrueAllele's analysis time increased to 3-4 days, while STRmix run times ranged from minutes to less than 1 day. TrueAllele has the capability to Award No. 2013-0N-BX-0074 Niche Vision Sale Source 08/25 /2014 Page 4 of? epic.org EPIC-16-02-02-CalDOJ-FOIA-20160219-Procurement-Justification-STRmix 000004

interpret multiple samples at the same time, but the purchase of multiple STRmix licenses yields the same result. During the studies of sensitivity and precision, the diagnostic tools available in TrueAllele suggested, albeit on a somewhat subjective level, that the MCMC process had not always proceeded in an ideal manner, and reruns could be in order. These questionable results at times contributed to poor precision between replicates. Other times, it led to replicates that were very precise but' with poor sensitivity. Examples were also observed of identical results occurring in sample types where that would not be expected, despite the randomness associated with MCMC. As a counterpoint, STRmix results rarely warranted re-runs. Where they were called for in this study, the diagnostic was objective, and the time required to complete the reanalysis was lower than with TrueAllele. Overall, we found that STRmix will give more reproducible and sensitive results with fewer reanalyses. Timeliness The project period for award 20 13-DN-BX-0074 is set to end on March 31, 2015. The purchases will be made very soon after the Sole Source GAN is approved. Implementation of STRmix should be more rapid than with TrueAllele. TrueAllele requires the use of its own data analysis software. Raw files from genetic analyzers are imported into TrueAllele for fragment sizing and comparisons to allelic ladders. In contrast, STRmix would simply replace our existing mixture interpretation software, stepping in at the same point of our well established process, while maintaining all other components. As with our current system, data created by our genetic analyzers would be processed through GeneMapper ID or ID-X, and peak tables would be exported for import into the mixture interpretation software. By maintaining much of our current work flow, we anticipate both a reduction in required training and an increase in initial comfort level with the process. Without the ability to purchase the STRmix within the project period, the goals of the project would not be met. Uniqueness There are still only two mixture interpretation systems commercially available from US distributors that allow for more than three contributors, automatically consider stutter artifacts as possible alleles, use fully probabilistic interpretation approaches, and automatically account for degraded DNA. Regarding the number of contributors allowed, TrueAllele Casework will allow for up to 6 unknowns, while STRmix will test Award No. 2013-DN-BX-0074 Niche Vision Sole Source 08/25 /2014 Page 5 of7 epic.org EPIC-16-02-02-CalDOJ-FOIA-20160219-Procurement-Justification-STRmix 000005

up to a 4-person mixture. We feel it is clearly a benefit to be able to test mixtures with more than three contributors, but the general consensus among criminalists within our bureau is that there is less of a desire to interpret mixtures of 5+ individuals. Beyond the results of our comparison studies, one additional factor distinguishes STRmix: STRmix is a standalone piece of software that can be loaded on to any of our agencies current laptops or desktops. Should the computer cease to function, all that is required to continue operations is to load the STRmix onto another computer and acquire a new license file from NicheVision. With multiple copies of STRmix in each of our DNA testing laboratories, this process should not interfere with casework processing. TrueAllele is server based, and the server and software are purchased as a unit from Cybergenetics. Should a server crash, interpretation of new mixtures would cease to happen until the server could be repaired or replaced. Other Concerns were raised about the sizing and allele calling approach in TrueAllele. The data analysis component of that system is such that capillary data is converted into a virtual gel, and the sizing algorithm takes adjacent lanes into account. Despite the data being from a capillary, the size of fragments can vary depending upon the other samples imported into this virtual gel. Similarly, heights and allele designations were seen to occasionally change from the values listed prior to upload to the server and those listed after processing in the server. This was mostly limited to low RFU peaks, but in a system that examines peaks down to a 10 RFU threshold, this remains a concern. In contrast, the source of size and allele designations for STRmix is GeneMapper, and our experience has shown this software package to be completely uniform when analyses are performed under identical settings. As with other crime laboratories throughout the country, our agency is anticipating a transition to a new autosomal STR multiplex. However, it is not yet decided which one we will use. New multiplexes can be added to STRmix in-house, without the assistance of Niche Vision or ESR. TrueAllele, on the contrary, is the source of all software updates for new typing systems, both multiplexes and capillary electrophoresis systems. We favor the ability to add systems at our discretion. We acknowledge that there are free software systems for the interpretation of complex mixtures, but to date these are limited to systems that apply very rough approximations to complex issues. The shift from our current approach to one involving probabilistic genotyping will require a significant commitment from our caseworkers. It is in our best interest to make such a change to a Award No. 20 I 3-DN-8X-0074 Niche Vi sion Sole Source 08125 /2014 Page 6 of7 epic.org EPIC-16-02-02-CalDOJ-FOIA-20160219-Procurement-Justification-STRmix 000006

package that is leading the movement. Declaration that this action is in the best interest of the agency This expenditure is in the best interest of the Bureau of Forensic Services CA 001. Our current approaches are both time consuming and highly limiting as to the amount of information that can be obtained from complex DNA mixtures. The STRmix software will greatly increase our capacity and capabilities. Award No. 2013-0N-BX-0074 Niche Vi sion Sole Source 08125/2014 Page 7 of? epic.org EPIC-16-02-02-CalDOJ-FOIA-20160219-Procurement-Justification-STRmix 000007