Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Similar documents
Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

The Potential of HFC-134a and HFC-152a to Replace CFC-12 in Medium Temperature Heat Pump Applications

Low GWP Refrigerants for Air Conditioning Applications

Purdue e-pubs. Purdue University

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Comparison of Performance of a Residential Air- Conditioning System Using Microchannel and Finand-Tube

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Air-Cooled Heat Exchanger Performance for R410A

Compressor Capacity Control: A New Direction

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Study of R161 Refrigerant for Residential Airconditioning

Performance Analysis of a Miniature-Scale Vapor Compression System for Electronics Cooling: Bread Board Setup

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

TEST REPORT #47. System Drop-in Test of R-32 and Refrigerant Blends ARM-71a, HPR2A, L-41-2 and DR-5A in a Five-Ton R-410A Rooftop Packaged Unit

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants

TEST REPORT #32. System Soft-Optimized Test of Refrigerant D2Y60 in Air Source Heat Pump

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Oil Return Measurements In A Unitary Split System Air Conditioner Using Different Refrigerant Mixtures

Efficiency of Non-Azeotropic Refrigerant Cycle

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Performance Measurement of R32 Vapor Injection Heat Pump System

Performance of CO2 Cycles with a Two-Stage Compressor

R32 Compressor for Air conditioning and Refrigeration applications in China

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

TEST REPORT #53. System Drop-in Test of Refrigerant Blend DR-55 in a Five-Ton R-410A Rooftop Packaged Unit

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

System Using Exhaust Heat from Residential GHPs

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

A Performance-Enhancing Additive for Vapor- Compression Heat Pumps: Additional Test Results

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

High Efficiency R-134a Compressor for Domestic Refrigerator

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Performance Evaluation of a Plug-In Refrigeration System Running Under the Simultaneous Control of Compressor Speed and Expansion Valve Opening

Effects of Oil on atranscritical Carbon Dioxide Air Conditioning Systems some experiences -

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Sub-Critical Operation of the CO2 Expander/ Compressor

Evaluation and Optimization of System Performance using HFO-mix Refrigerants for VRF and Mini-split Air-Conditioner

Dynamic Simulation of Liquid Chillers

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Steady and Cyclic Performance Testing of Packaged R-410A Units

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

Some Thermodynamic Performance Test Results of Refrigerant 134a

Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

Behavior of R410A Low GWP Alternative Refrigerants DR-55, DR-5A, and R32 in the Components of a 4-RT RTU

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

Performance Comparison of R32, R410A and R290 Refrigerant in Inverter Heat Pumps Application

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

TERNARY ZEOTROPIC MIXTURE WITH CO 2 COMPONENT FOR R-22 HEAT PUMP APPLICATION

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

Experimental Study on the Thermal Behavior of a Domestic Refrigeration Compressor during Transient Operation in a Small Capacity Cooling System

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Performance Evaluation of Heat pump System using R32 and HFO-mixed Refrigerant in High Ambient Temperature.

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

System Modeling of Gas Engine Driven Heat Pump

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

TEST REPORT #63. Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP)

Effects of Refrigerant-Lubricant Combinations on the Energy Efficiency of a Convertible Split-System Residential Air-Conditioner

Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

Experimental Study on the Performance of Twisted Capillary Tube

Development of an Open Drive Scroll Compressor for Transportation Refrigeration

Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â Summary of Phase II Testing Results

Refrigerant Mass and Oil Migration During Start-up Transient

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Alternative Refrigerants For Household Refrigerators

Performance Characteristic and Optimization of a Simultaneous Heating and Cooling Multi Heat Pump

Mini Vapour Cycle System For High Density Electronic Cooling Applications

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

TEST REPORT #34. Compressor Calorimeter Test of Refrigerant DR-7 in a R-404A Scroll Compressor

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2000 Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10 J. W. Linton National Research Council Canada W. K. Snelson National Research Council Canada P. F. Hearty National Research Council Canada Follow this and additional works at: http://docs.lib.purdue.edu/iracc Linton, J. W.; Snelson, W. K.; and Hearty, P. F., "Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10" (2000). International Refrigeration and Air Conditioning Conference. Paper 467. http://docs.lib.purdue.edu/iracc/467 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

PERFORMANCE OF R-22, R-407C AND R-410A AT CONSTANT COOLING CAPACITY IN A 10.0 SEER 10.5 kw RESIDENTIAL CENTRAL HEAT PUMP J.W. Linton, W.K. Snelson and P.F. Hearty Thermal Technology Centre National Research Council Canada M-17, Montreal Road Ottawa, Ontario, Canada, K1 A OR6 ABSTRACT The performance of two long-term replacements R-407C (HFC-32/125/134a (23%/25%/52%)) and R-410A (HFC-32/125 (50%/50%)) was compared to R-22 on a constant compressor capacity basis in a 10.5 kw residential central heat pump. The performance evaluations were carried out in a calorimetric test facility using the Canadian Standards Association (GSA) I Air-Conditioning and Refrigeration Institute (ARI) rating conditions. The hermetic reciprocating compressor that was supplied with the heat pump was replaced with an open drive-reciprocating compressor connected to a variable speed motor. The performance of R-22, R-407C, and R-41 OA was measured using the same open drive-reciprocating compressor. The compressor speed was adjusted for each of the two HFC refrigerants to provide the same cooling capacity as the R-22 base case at the 'A' test condition. Additional air-conditioning performance testing was completed on all the refrigerants at an extreme outdoor ambient temperature of 45 C to determine if the cooling capacity and EER of R-41 OA deteriorate at these temperatures compared to R-407C. Performance characteristics were measured including system operating conditions, compressor shaft power, cooling and heating capacity, cooling energy efficiency ratio (EER) and heating coefficient of performance (COP). INTRODUCTION Previous studies of R-22 and long-term replacements R-407C and R-41 OA have used different types and sizes of compressor to directly compare the capacity and performance differences of these refrigerants (Linton 1996). The objective of this investigation is the comparison of these three refrigerants using the same compressor operating at different speeds (supplying the same cooling capacity) to provide a more accurate indication of the system differences of the long term replacements. The comparison of R-407C and R-41 OA was completed in a 10.5 kw Carrier residential central heat pump with the base case R-22 at the standard Air-Conditioning and Refrigeration Institute (ARI) I Canadian Standards Association (GSA) rating points (GSA 1991). The air-conditioning performance Eighth International Refrigeration Conference at 71

at a high outdoor ambient temperature (approximately 45 C DB) was also evaluated to determine if the cooling capacity and EER of R-410A deteriorate at these temperatures compared to R-407C. TEST DESCRIPTION The performance evaluation was completed in the Calorimetric Test Facility located at the Thermal Technology Centre, National Research Council. The Calorimeter consists of two environmentally controlled test chambers that simulate indoor and outdoor conditions with precise control of the air dry bulb and wet bulb temperatures. In order to compare the performance of R-407C and R-41 OA with R-22, a series of tests was performed on a standard 10.0 SEER Carrier 10.5 kw cooling capacity air-to-air residential heat pump. The original hermetic reciprocating compressor that came with the heat pump was changed to an external two cylinder-reciprocating compressor driven by a 1 0 HP variable speed electric motor. Original equipment on the heat pump also included fixed orifice type expansion devices on the indoor and outdoor coil. The indoor coil consisted of a single sloped fin and tube coil with three tube rows and five refrigerant circuits. The indoor coil was mounted in the original position as received from the factory. The indoor coil was in a cross-parallel flow configuration for the air-conditioning tests and in a cross-counter flow configuration for the heating tests. The outdoor coil was a single row fin and tube type coil with three refrigerant circuits. Table 1 lists the five standard CSA indoor and outdoor test conditions (plus the extreme operating condition) for a split system air-to-air heat pump. Type of Test Indoor Conditions Outdoor Conditions "A" Steady State Wet-Coil 2rC DB I 19 C WB 35 C DB "B" Steady State Wet-Coil 27 C DB I 19 C WB 27.8oC DB Maximum Oper. Cond. (AC) 2rC DB I 19 C WB 40 C DB Extreme Oper. Cond. (AC) 2rC DB I 19oC WB 45 C DB High Temperature Heating 21 C DB /16 C WB 8.3 C DB I 6.1 oc WB Low Temperature Heating 21oC DB /16 C WB -8.3 C DB /-9.4 C WB Table 1: CSA I ARI cooling test conditions for split system residential air-to-air heat pumps The heat pump was extensively instrumented, and the air enthalpy and refrigerant mass flow rate methods were used to determine the unit's indoor coil steady state cooling and heating capacity. Energy balances between the air and refrigerant side were within 1% to 2% for R-22 and within 2% to 3% for R-407C and R-41 OA. It is believed that the larger discrepancies in the energy balance for R-407C and R-41 OA are related to uncertainties of the refrigerant properties. The cooling and heating capacities reported in this paper were from the air side measurement data. Refrigerant temperatures were recorded using type T (copper-constantan) thermocouples soldered to the refrigerant Eighth International Refrigeration Conference at 72

tubing. The uncertainty of the thermocouple temperature measurements was ±0.6 C. Refrigerant pressures were measured using pressure transducers connected to static pressure taps located at strategic points in the system. The pressure transducers were calibrated to ±3 kpa. Refrigerant mass flow was measured directly with a Coriolis effect mass flowmeter mounted in the liquid line leaving the condenser. The mass flow meter was calibrated to provide an accuracy of ±0.5% of measurement. Shaft power input to the reciprocating compressor was measured with a torque and speed sensor that was mounted between the drive shaft and the electric motor. The torque sensor is a strain gauge type with an accuracy of ±5.6x1 o- 2 Nm. The indoor and outdoor fan power was measured with watw AR transducers with an accuracy of ± 1.0% of reading, and the supply voltage to the compressor and indoor and outdoor fans was regulated at 230 volts. The energy efficiency ratio (EER) and coefficient of performance (COP) figures reported in the paper were based on the shaft power consumption of the compressor and the electrical power consumption of the indoor and outdoor fans. The indoor air quantity was set so that a minimum external resistance of 37.5 Pa was maintained at the outlet of the unit by adjusting an auxiliary fan located on the outlet of the test section ductwork. For the R-22, R-41 OA and R-407C performance tests the only changes made to the heat pump were to substitute an external variable speed reciprocating compressor for the hermetic compressor and the installation of electronic expansion valves (EEV) and bypass check valves in place of the factory supplied combination fixed orifice and check valves. The EEV allowed accurate setting of the superheat for each refrigerant. To achieve a fair comparison of azeotrope to a single refrigerant or near azeotrope, the refrigerant cycle operating conditions need to be defined. The evaporating temperature was defined as the mean of the evaporator outlet pressure dew point and the evaporator inlet temperature. The condensing temperature was defined as the mean of the dew point and bubble point at the average condensing pressure. The superheat was measured from the compressor inlet pressure dew point and the subcooling temperature from the expansion valve inlet pressure bubble point respectively. The source of thermodynamic properties for R-22, R-407C, and R-41 OA was REFPROP version 4.0. TEST METHOD The compressor speed, refrigerant charge and EEV orifice setting was adjusted for each refrigerant at the "A" air-conditioning test conditions to achieve a 10.5 kw capacity and maximum EER. For the other three air-conditioning operating test conditions the compressor speed and refrigerant charge were not adjusted. The expansion valve was set in a manual operating mode at the same orifice setting that was used for the "A" test condition to simulate the air-conditioner operating with a fixed orifice expansion device. The same compressor speed and refrigerant charge were used for the heat pump in the heating mode. The EEV orifice setting was set to obtain the maximum cooling capacity at the high temperature heating test condition. The same orifice setting was used for the low temperature heating test condition. Setting the EEVs in this way closely duplicates the Eighth International Refrigeration Conference at 73 Purdue University, West Lafayette, IN, USA- July 25-28, 2000

operation of the heat pump with the fixed orifices that the heat pump was originally equipped with. Using the established refrigerant operating charge and fixed orifice setting for the evaporator superheat at the "A" test condition, the performance of the heat pump was evaluated for the specified indoor and outdoor test conditions. The baseline performance tests were completed for R-22 using a polyol ester (POE) lubricant with a viscosity of 32 mm 2 /s at 40 C. The performance tests were then repeated with R-407C and R-41 OA and the same POE lubricant used in the R-22 tests. Finally, the compressor was operated in a vacuum at the same compressor speed that was used for each.refrigerant and the same POE lubricant to measure the mechanical losses of the compressor. TEST RESULTS AND DISCUSSION Effect of Compressor Speed on Performance The heat pump constant cooling capacity tests was run using the same variable speedreciprocating compressor for all the test refrigerants. Table 2 shows the compressor RPM required to maintain the same cooling capacity for each refrigerant at the "A" test condition. The Table shows that R-410A required a 43% lower compressor speed than R-22 for the same cooling capacity. The Table also shows the required shaft power (mechanical losses) of the compressor when it was operated in a vacuum at the test operating speeds that were used for each refrigerant. By factoring in these mechanical losses it is estimated that the energy consumption of R-41 OA would be about 3% higher at the "A" test condition if the compressor speed was similar to the two other refrigerants. R-22 R-410A R-407C Compressor speed for tests (RPM) 1683 948 1725 Compressor power in a vacuum at test speed (watts) Table 2: Compressor operating speed and power in a vacuum 147 65 155 The lower compressor speed used for R-41 OA will also have an effect on the compressor volumetric and isentropic efficiency. Work on reciprocating compressors by Villadsen (1985) showed that volumetric efficiency would be higher at lower compressor speeds. More importantly for compressor power the lower compressor speed could provide a significant improvement in the isentropic efficiency. The lower compressor operating speed required by R-41 OA therefore provided it with an unfair efficiency advantage over R-22 and R-407C. However, no correction factor was applied to the performance test results shown for R-41 OA. Eighth International Refrigeration Conference at 74

Comparison of Operating Conditions Evaporator Outlet Pressure Cooling mode During testing at the cooling mode operating conditions R-22 and R-407C had similar evaporator outlet pressures, with R-407C having a slightly lower evaporator pressure. R-41 OA is a higher-pressure refrigerant than R-22 and it had evaporator outlet pressure that was about 64% higher that R-22. Heating mode R-407C had a slightly higher evaporator outlet pressure than R-22 for the two heating mode test conditions. R-41 OA had evaporator outlet pressures that ranged from 71% - 76% higher than R-22. Condenser Inlet Pressure Cooling mode The condenser inlet pressure of R-407C was 12% to 15% higher than R-22 for the four cooling test conditions. R-41 OA had a condenser inlet pressure that ranged from 54% to 58% higher than R-22. Heating mode The condenser inlet pressure of R-407C was 5.4% to 21% higher than R-22 for the two heating mode test conditions. R-41 OA had a condenser inlet pressure that ranged from 56% to 69% higher than R-22 Compressor Pressure Ratio Cooling mode The compressor pressure ratio of R-407C ranged from 12% to 14% higher than R-22 for the air-conditioning conditions. R-410A had the lowest compressor pressure ratio of the refrigerants tested, ranging from 9% to 12% lower than R-22. The measured evaporating and condensing temperatures of all the refrigerants were similar. Heating mode The compressor pressure ratio of R-407C was 0.7% to 9.3% higher than R-22 for the two heating mode test conditions. R-41 OA had the lowest compressor pressure ratio of the refrigerants tested ranging from 3.4% to 11.7% lower than R-22. The measured evaporating and condensing temperatures of all the refrigerants were also similar in the heat pump heating mode, with R-407C having the highest evaporating temperature and R-22 the lowest. Compressor Discharge Temperature Cooling mode The compressor discharge temperature was measured at the outlet of the compressor. For air-conditioning test conditions R-407C had a 3 C to soc lower discharge temperature than R-22. R-41 OA had compressor discharge temperatures that were 9 C to 11 oc lower than R-22. Heating mode R-407C had compressor discharge temperatures that were 1 octo 12 C lower than R-22 for the heat pump test conditions, R-41 OA's discharge temperature was about i oc to soc lower than R-22. The lower discharge temperatures of the R-22 replacements could provide an advantage to compressor and lubricant long-term operation when at extreme operating conditions. Eighth International Refrigeration Conference at 75

Eighth International Refrigeration Conference at 76 Figure 2 shows the heat pump heating capacity for the high and low temperature test conditions. The experimental values of heating capacities were also obtained from air Heating Capacity Figure 1 shows the heat pump cooling capacity for the four air-conditioning test conditions. The experimental values of cooling capacities were obtained from air enthalpy measurements between the inlet and outlet of the indoor unit. Figure 1 shows that at the "A" test condition all the cooling capacities are about the same (compressor speed was changed to provide the same cooling capacity at this condition). R-407C had the same cooling capacity as R-22 at the "8" test condition, the capacity then decreased relative to R-22 to be about 5% lower at the extreme operating condition. R-41 OA had a 3% higher cooling capacity at the "8" test condition and then the capacity decreased to 5% lower than R-22 at the maximum operating condition and 10% lower at the extreme operating condition. Cooling Capacity Figure 3. Energy Efficiency Ratio Figure 4. Coefficient of Performance A Test 8 Test Max Extreme High Temp Low Temp I m R-22 o R-41 oa m R-4o7c I jlir-22 rn R-410A m R-4o7c I Figure 1. Cooling Capacity Figure 2. Heating Capacity A Test 8 Test Max Extreme High Temp Low Temp I~R-22 or-410a mr-4o7c 1 lmr-22 or-410a mr-407c 1

enthalpy measurements between the inlet and outlet of the indoor unit. The Figure shows that R-407C had a heating capacity that was 5% higher than R-22 at the high temperature test condition and was 12% higher than R-22 at the low temperature test condition. The heating capacity of R-41 OA ranged from 1% to 2% lower than R-22. Energy Efficiency Ratio (EER) The heat pump energy efficiency ratio (EER) is shown for the four cooling test conditions in Figure 3. The EER was derived by dividing the cooling capacity (measured on the airside) by the shaft power input to the compressor plus the indoor and outdoor fan power. R-407C had an EER that ranged from 5. 7% to 11% lower than R-22. The EER of R-41 OA ranged from 4.3% to 21.4% higher than R-22. Compared to the other two refrigerants the EER of R-41 OA also decreased much more rapidly at the high and extreme operating temperature test conditions. This is due to the lower critical temperature of R-41 OA. The EER values shown for R-41 OA do not include any correction factor to compensate for the improved compressor efficiencies at the lower operating speeds. Coefficient of Performance (COP) The heat pump coefficient of performance (COP) for the two heating test conditions is shown in Figure 4. The COP was derived by dividing the heating capacity (measured on the airside) by the shaft power input to the compressor plus the indoor and outdoor fan power. R-407C had a COP that ranged from the same as R-22 at the high temperature test condition to 1.6% lower at the low temperature test condition. The COP of R-41 OA ranged from 7% to 8.4% higher than R-22. The COP values shown for R-410A do not include any correction factor to compensate for the improved compressor efficiencies at the lower operating speeds. CONCLUSIONS A comparison was made of the performance of long term replacements R-407C and R-41 OA with the reference case R-22 in a 10.5 kw (3.0 TR) residential size central heat pump. The performance was measured using the same open drive-reciprocating compressor. The compressor speed was adjusted for each of the two refrigerants to provide the same cooling capacity as the R-22 base case at the "A" test condition. For the R-22 and R-407C performance tests the only other change made to the heat pump was the installation of electronic expansion valves in place of the factory supplied fixed orifice. R-407C had the same cooling capacity as R-22 at the "8" test condition, the capacity then decreased relative to R-22 to be about 5% lower at the extreme operating condition. R-41 OA had a 3% higher cooling capacity at the "8" test condition and then the capacity decreased to 5% lower than R-22 at the maximum operating condition and 10% lower at the extreme operating condition. Eighth International Refrigeration Conference at 77

R-407C had a heating capacity that was 5% higher than R-22 at the high temperature test condition and was 12% higher than R-22 at the low temperature test condition. The heating capacity of R-41 OA ranged from 1% to 3% lower than R-22. The heat pump cooling energy efficiency ratio (EER) of R-407C ranged from 5.7% to 11% lower than R-22. The EER of R-41 OA ranged from 21.4% to 4.3% higher than R-22. Compared to the other two refrigerants the EER of R-41 OA also decreased much more rapidly at the high and extreme operating temperature test conditions. This is due to the lower critical temperature of R-41 OA The heat pump heating coefficient of performance (COP) for R-407C ranged from the same as R-22 at the high temperature test condition to 1.6% lower at the low temperature test condition. The COP of R-410A ranged from 7% to 8.4% higher than R-22. The EER and COP values shown for R-41 OA do not include any correction factor to compensate for the improved compressor efficiencies at the lower operating speeds. REFERENCES Canadian Standards Association 1991. Performance Standard for Split-System Central Air-Conditioners and Heat Pumps. Standard CAN/CSA-C273.3-M91 (revised January 1993), Rexdale, Ontario, Canada Linton, J.W., Snelson, W.K., Hearty, P.F., Triebe, A.R. Murphy, F.T., Low, R.E. and Gilbert, B. E., 1996. Comparison of R-407C and R-41 OA with R-22 in a 10.5 kw {3.0 TR) Residential Central Heat Pump. 1996 International Refrigerants Conference at Purdue, July 21-26, Purdue University, West Lafayette, Indiana, pp. 1-6. Villadsen, V., 1985. Reciprocating Compressors for Refrigeration and Heat Pump Application. International Journal of Refrigeration, 1985, VoL 8, September. Eighth International Refrigeration Conference at 78 Purdue University, West Lafayette, IN, USA- July 25-28, 2000