pump SMP60 Technical Data Sheet

Similar documents
Rugged dependability. DeLaval manure pumps. Clearing manure from barns. is vital for animal health, but. time consuming.

Profitable manure handling starts here. DeLaval manure solutions

Choose your DeLaval mixer

NEW. Tundra LTX Hydraulic Pump. Reliable liquid manure transfer system from Patz. Let Patz handle your manure so you don t have to!

DeLaval Optimat II gain more time and cut your biggest cost

Automation for feed efficiency

Safeguarding quality. Milk cooling solutions for VMS. Your solution every day

Hygiene cleaning equipment Keeping all equipment clean

Connecting you to herd management

CIRCULATORY AGITATION SYSTEMS FOR CONCRETE DAIRY MANURE STORAGE TANKS

Safe, comfortable, efficient DeLaval parallel parlour P2100

Dairy Housing Manure Handling Options for Robotic Milking Barns H. House, P.Eng.

Vertical Downstroke Baler. Designed For: * Warehouses * Retail Chains * Distribution Centers * Manufacturing Plants *

Simple steps to healthy hooves

EYS SEPARATOR EYS 01 G. USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G. User Manual for EYS 01G Screw-Press Separator

evac User Manual March 2014 Prepared by: Gareth Wilson and Sinethemba Mngomezulu

High Pressure Water - Descale Valves - VXXX Series. Quad-S TM Poppet Cartridge Zero Leakage, Media Piloted Raw Water Operation

Installation Instructions for. CattleMaster Series Fountains

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

Cold water compact class HD 1.8/13 C Ed

REVERSING DRUM MIXER

Vickers. Service Data. Piston Pumps. PVH57/63 Variable Displacement Piston Pump - 11 Design M-2206-S. Revised 11/01/97

PRO 2000i LOW LEVEL DEPOSITOR

Panel Fan Series Operators Manual (Galvanized and Polymer)

Colloidal. Grouting. Equipment. Featuring ChemGrout s TurboMix Colloidal mixer. Heavy Construction. Marine/ Offshore. Mining & Tunneling.

Freedom to choose. DeLaval voluntary milking system VMS

Installation Instructions for. OmniFount

INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE

Service Data Vickers. Piston Pumps. PVH98/106 Variable Displacement Piston Pump - 11 Design M-2208-S. Revised 05/01/97

PAVER BLOCK FIXING INSTRUCTIONS VYARA ROTATIONAL INTERLOCK

Panel Fan Series Operators Manual (Galvanized and Polymer)

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

MOUNTING INSTRUCTIONS

STAINLESS STEEL UNITS

568X, 587X, 588X Series

INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL)

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Service Data Vickers. Piston Pumps. PVH74/81 Variable Displacement Piston Pump - 11 Design M-2207-S. Revised 11/01/97

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

Cold water compact class HD 2.3/14 C Ed Food

Installation Instructions for. DairyFount Series Fountains

PUMPS AND PROP AGITATORS

Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series

! WARNING. Before using product, read and understand instructions.

Model LF-310 Air Operated

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions for. WaterMatic Fountains

Integrated Robotic Solutions. Your future is our why

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

Bid Specifications for Thermo-Lay model UD /4 yard truck mounted machine with hydraulic bins & roller DIMENSIONS: Body:

Goulds HSU, HSUL & JCU. Submersible Pumps

Installation Instructions for. OmniFount

INSTALLATION INSTRUCTIONS

Item # Modular Blast CaBinEt instructions

Installation Instructions for. OmniFount

PRE-INSTALLATION GUIDE

EXTREME HC-2 Reverse Osmosis System

Rif Cod i220-0

Underfloor Heating Control Pack

Progressive cavity pump FJ/FG.. S.. B

569, 570, 571, 572 Series

! WARNING. Before using product, read and understand instructions.

569, 570, 571, 572 Series

The Collection Chamber

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

Manual Pressure Pump Generators Standard Laboratory Models Operation and Seal Packing Instructions

Installation Instructions for. WaterMaster Series Fountains

! WARNING. Before using product, read and understand instructions.

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

Installation Instructions for. WaterMaster Series Fountains

OWNERS GUIDE TO INSTALLATION AND OPERATION

PRE-INSTALLATION GUIDE

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

SHREDDING OF PIPES AND PROFILES With granulators and shredders Pipes up to 3000 mm diameter One work process Low noise emissions

FB-310A. Removes Chips, Sludge & Solids with Minimal Downtime

Powers TM Controls Accessories for Installing TH 192, TH 194 or Free Energy Band TH 193 HC Room Thermostats

DeLaval activity meter system Instruction Book

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

E.2 series high efficiency circulator. Installation and operating instructions

1600 Series Rotating Suction Screen

Installation and operating instructions. E.2 Series high efficiency circulator

PRE-INSTALLATION GUIDE

DUPLEX CONDENSATE TANK SYSTEM

DRI-AIR INDUSTRIES, INC. AHM & HPHM 2-4 HOPPER MOUNT DRYERS OPERATING MANUAL

InService Protect your investment

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL

Operating Instructions for CRIMPING TOOL HP 95

OPERATOR S MANUAL. For BURLY ATTACHMENTS

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

EXTREME HP-1 Reverse Osmosis System

Installation & Service Manual

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

STEPP SRM 10x120(Asphalt Recycler) SPECIFICATIONS. SRM 10x120 Self Loading

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

OWNER S MANUAL VERSION 4.4 SERIAL # X-1 SINGLE LAYER PRESS. With EG-260 Variable Speed Grinder

TC-710 RECYCLING BALER

Transcription:

DeLaval semisolid manure pump SMP60 Technical Data Sheet

DeLaval semi-solid manure pump SMP60 Lockout valves Hopper Access port Inlet tube Bolted outlet

Unique features found only on SMP60 Features Hopper choices Hopper Inlet tube Hydraulic lockout valves Advantages It is important that the incoming bedded manure is deposited directly into the inlet tube. SMP60 is offered with a variety of hopper sizes and shapes to suit different layouts so that the incoming flow can always be directed to the ideal position. The bolt-on hopper on SMP60 pumps may be replaced when they are corroded. The SMP60 has a large diameter, round inlet tube compared to competitive pumps with rectangular inlet tube. Bedded manure does not conform well to the rectangular shape, allowing air to travel down the corners of the rectangular tube. This will prevent the manure from advancing into the pump during the suction stroke. The round inlet tube allows the pump and hopper to be oriented in different directions. The pump may be rotated up to 20º to the left or right of the hopper centerline. This may allow for less elbows in the pipe. The hydraulic cylinders on both guillotine gates are equipped with lockout valves. These may be used to lock a guillotine gate in position. This is very useful in the event that the hopper or pipe becomes blocked. The gate nearest the blockage can be locked open and the opposite gate closed, so when the piston is operated it will agitate the blockage and loosen it. Outlet access port In case of a severely blocked pipe, this port offers access for a pipe cleaning service. Bolted outlet Allows a selection of outlet sizes to suit the available pipe in different areas. This bolt flange also makes it possible to detach the pump from the pipe for eventual replacement.

Technical data Weight: SMP60 1 360 kg (3 000lb) Dimensions: 3702.05 mm x 762 mm x 2 705, 1 mm (145.3/4" x 30" x 2 705.½") (A) With third guillotine Pumping Capacity: The following table givves important data regarding the design of the system. Manure consistency affects these values. They are given as a rough guide only. Manure Type Average Flow Rate Maximum output pressure Maximum length of 40.6 mm (16") pipe Semi-liquid manure, free stall 3.28 l/s (52 GPM) 586 kpa (85 PSI) 100 m (350") barn, small amount of bedding. Solid manure, tied stall barn, large amount of bedding. (Maximum 2 kg straw/cow and day.) 2.65 l/s (42 GPM) 586 kpa (85 PSI) 60 m (200 ) DeLaval semi-solid manure pump SMP60 is a heavy duty hydraulic piston pump designed to transfer manure from the barn to a storage pit. The maximum use of bedding material, straw, is 2 kg/cow and day. The SMP60 is capable of transferring solid or semisolid bedded manure long distances with low power requirements. The 7.5HP hydraulic power unit makes the SMP60 an excellent choice for use with single phase electricity or anywhere that power availability may be limited. Limitations: Requires enough water to allow suction seal to work Long and large amounts of bedding require more added water Always mix very dry materials with wetter materials (pen manure should be mixed with dairy cow manure) Not for use with sand bedding

Principle of operation The SMP60 is a heavy duty hydraulic piston pump designed to transfer manure from the barn to a storage pit. It is activated by hydraulic pressure from Delaval Power Pack. When activated, the sequence is controlled by hydraulic control valves and a mechanical reversing switch. The outlet guillotine valve closes and the inlet guillotine opens. The piston then goes up and siphons the manure from the hopper. When the piston reaches the reversing switch, the inlet guillotine valve closes and the outlet guillotine valve opens. The piston then starts going down and pushes the manure to the storage pit.

Planning Installation layout Full Pit Installation The SMP60 is typically installed below ground level with the hopper at barn cleaner height. From that position, the underground pipe should start straight from the outlet of the piston. The barn cleaners usually reach inside the hopper to drop in the manure. It is also possible to install the hopper below a grid to bring the manure to it with a shovel or a tractor. There are some elements to consider when designing a SMP60 layout. First, the hopper must conform to the barn cleaner configuration. Second, an angle of 30 must be made in the concrete to prevent premature barn cleaner chain and paddle wear. A: Top of hopper at the height of barn cleaner B: Barn cleaner C: Chamfer edge 50 mm (2'') height with 30º slope.

Different hopper configurations There are different hopper configurations depending on the number of barn cleaners and their relative positions. Below there just some examples: Hopper configuration Example Suggested pit dimensions Single Clockwise Barn Cleaner Single Clockwise Barn Cleaner Double Clockwise Barn Cleaner Double Barn Cleaner

www.delaval.com Country 1 Address line 1 Address line 2 Address line 3 Tel XX XXX XX XX Fax XX XXX XX XX e-mail address web address Country 2 Address line 1 Address line 2 Address line 3 Tel XX XXX XX XX Fax XX XXX XX XX e-mail address web address Your DeLaval dealer is a registered trademark of Tetra Laval Holdings & Finance S.A. and DeLaval is a registered trade/service mark of DeLaval Holding AB. The manufacturer reserves the right to make design changes. 53571045-200905