ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

Similar documents
GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

MODBUS RS485. » Technical instructions. Air Comfort. Housing ventilation

IPSUM OPTIMIZATION SYSTEM» DEMAND CONTROLLED VENTILATION OVERVIEW

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

recooler HP EQKR HEAT PUMP

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

CE-marked ESAD - Smoke Control Duct System Installation instructions 08/2013

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D

eq PRIME » ENERGY EFFICIENCY AND FLEXIBILITY STRAIGHT OUT OF THE BOX AIR COMFORT AIR TREATMENT AIR HANDLING UNITS

HOTEL CHILLED BEAM IQ STAR SILENCIA

Bevent Rasch BSKC6. - Fire /06/17

ROOFMASTER STEF-HT ROOF FAN

A COMPLETE RANGE OF CHILLED BEAMS FOR COMFORT AND FLEXIBILITY

TopMaster Air Handling Unit

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016

CHILLED BEAM CASSETTE IQ STAR LYRA

iq Star LYRA II chilled beam cassette

Bevent Rasch RABC-VAV. - Fire /03/2018

TopMaster Air Handling unit. Technical data

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

CONDOR. Supply air ceiling QUICK FACTS

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Type EK-EU FOR MECHANICAL SMOKE EXTRACT SYSTEMS AND AS AN ADDITIONAL SUPPLY AIR INLET, ALSO FOR NATURAL SMOKE AND HEAT EXHAUST SYSTEMS

Bevent Rasch. FIDm. - Fire /11/2018

Kezdőlap > Termékek > Tűz és füst elleni védelem > Füstmentesítő csappantyúk > Típus EK-EU. Típus EK-EU

TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Fire dampers. For diverse applications

Heat recovery unit RDKS

Smoke extract fan SMHA HATCH

MARINE APPLICATIONS MARINE» PRODUCTS AND SOLUTIONS FOR MARINE APPLICATIONS

KOMFORT EC DB Suspended heat recovery air handling units

Cleaning doors. Good indoor air also means cleanability of ductwork

TopMaster Air Handling unit. Installation instructions

iq Star LYRA II chilled beam cassette

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU

TURBO HOODS. Product Brochure

Bevent Rasch. FIDs. - Fire /05/18

VAV CHILLED BEAMS Pi FUNCTION DESIGN GUIDE

Circular Fire Damper Cartridge

Series VENTS VUT R WH ЕС

VL120. Multi blade smoke evacuation damper 120' C-NT-V24-A 01/2016

Built-on speed controller for GMPM plug fan with permanent magnet motor

PARASOL EX. Suspended comfort modules QUICK FACTS

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

lindab we simplify construction LindabIndoorClimateSolutions Product overview Airborne Solutions

Primo Hotel. General. Indoor climate units for hotel rooms

K*, R* Ventilation grilles

Orion-Opus LØV-R with Sirius

Multi-Denco. » Precision Climate Control. Air Conditioning & Heating. Multi-DENCO

Orion-PTV LØV-R with Sirius

Orion-LØV LØV-R with Sirius

Smoke Master SMIA Compact pressurisation and smoke exhaust system

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Orion-LØV LØV-R with Sirius

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

BSK-RPR Fire Damper. Additional operating instructions according to

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

External insulated volume. control damper

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Smoke Master SMPA Compact pressurisation system

Lonworks Damper Interface Catalogue

Ceiling diffusers. Type DLQL

European Technical Assessment ETA 17/1007 of 02/05/2018

Ceiling swirl diffusers

Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

Ceiling swirl diffusers

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

UV-TURBO HOODS. Product Brochure

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

COMPACT Air & Heat. Contents

Air distribution systems. Opticlean OC-Q...

PARAGON. Compact comfort module. Key figures

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

AEROFOIL AXIAL FLOW FANS

APPLICATION GUIDE FOR OPTIVENT ULTRA

TECHNICAL SPECIFICATION

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

APPLICATION GUIDE DUCTABLE FANCOIL ARIA 2. 1,3-6,6 kw ARIA2-AGU-1610-E.

CPD COOKER HOOD TECHNICAL DATA

GOLDTM. Air Handling Units with Built-in Control Equipment that offer Economical Operation.

Unit heater with accessories

JSI-UV canopy - Ultraviolet and cyclonic filters, and supply air JSI-UV hoods Product Description Lights and filters

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

Air distribution systems. Opticlean OC-Q... DS 4136 E /1

Installation Smoke Detector ELQZ , GOLD

SINGLE-ROOM VENTILATION. for schools and public spaces

HEAT RECOVERY UNITS TSEK. Mech-Elec, 41, Hawthorn Road, Western Ind. Est., Dublin 12 Tel:

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

Transcription:

FIRE SAFETY AIR TREATMENT FIRE DAMPERS ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

2 ESAR Smoke control damper Technical catalogue Circular smoke control damper ESAR is specially designed to use in single fire compartment applications as a closing or as an opening damper for smoke extract purposes. ESAR is fulfilling the new european product standard EN 12101-8 requirements for single compartment applications and it is CE marked. The product has been tested according to EN 1366-10 fulfilling fire class E 120 S with pressure class 1000 Pa and temperature class 600 C. ESAR dampers are suitable both for automatically by a fire alarm activated systems (AA) and manually, after the fire has started, by fire fighter activated systems (MA), 25 min open / close. ESAR smoke control damper is designed so, that opening or closing can be made even 25 minutes after the fire has started, in 600 C. Factory mounted electrical actuator is placed inside fire resistant calcium-silicate box. By design phase and installation work it is very important to notice, that all cable system with connection boxes has to be done by fire resistant products. Electrical actuator changes the damper position from open or close with transfer time not more than 60 s. If the electricity is cut off, damper blade will remain in its position. Smoke control damper has two safety positions open or closed Smoke control damper is activated to transfer to safety position automatically by smoke detection or manually by switch used by fire fighters. Electrical actuator has 2 free auxiliary switches for open / close position indication Flow direction has no affect to the function of the damper PRODUCT DATA Sizes Ø100 - Ø630 mm (rectangular ESAS dampers with round connection pieces are used for bigger sizes) CE marking ESAR MPA No. 0761-CPD-0278 Fire class according to EN 13501-4 E600 120 (ve i <-> o) S1000C300MAsingle The fire damper fulfills the requirements of leakage class 3 according to EN 1751. The damper casing fulfills the requirements of leakage class C according to EN 1751. Pressure drop across a closed damper may amount to 2500 Pa. PRODUCT CODE EXAMPLE Smoke control damper ESAR-315-54-1 Smoke control damper ESAR is always delivered with factory mounted elctrical actuator 24 V or 230 V. Actuator is placed inside calcium-silicate box.

Technical catalogue ESAR Smoke control damper 3 TECHNICAL DATA - PRESSURE DROP, SOUND DATA PRESSURE DROP Pressure drop, when the damper is fully open 100 125 160 200 250 315 400 100 500 50 630 20 p t, Pa 10 5 2 1 L p10a, db(a) 30 50 100 200 500 1000 2000 5000 10000 q v, l/s 35 40 SOUND POWER LEVEL CORRECTION BY OCTAVE BANDS Octave band (Hz) 125 250 500 1000 2000 4000 8000 Correction K oct 16 10 5 0-7 -13-18 Tolerance +/- 6 3 3 3 3 3 3 L woct = L p10a + K oct DEFINITIONS q v Air flow l/s L Woct Sound power level in kanal db L p10a Sound pressure level with 4 db room attenuation (10 m 2 sab) db(a) K oct Correction db p s Pressure drop Pa

4 ESAR Smoke control damper Technical catalogue DIMENSIONS AND WEIGHTS Li 318 E C ØD 175 515 Size ØD C E Li Weight (kg) 100 * 160 159 220 35 10,7 125 * 160 159 220 35 10,7 160 160 159 220 35 10,3 200 200 203 260 35 10,8 250 250 237 310 40 11,2 315 315 281 380 40 13,3 400 400 390 470 60 14,7 500 500 480 570 60 17,2 630 630 600 740 60 21,6 * Delivered with extension piece BDED, when the total length is 495 mm (Ø100) or 465 mm (Ø125).

Technical catalogue ESAR Smoke control damper 5 PRODUCT CODE AND ACCESSORIES PRODUCT CODE EXTENSION PIECE FLD-AAA-1 Smoke control damper ESAR-aaa-bb-c A Size (aaa) 100, 125, 160, 200, 250, 315, 400, 500, 630 Actuator (bb) 54 = 24 V AC/DC 56 = 230 V AC Actuator model (c) 1 = Standard ACCESSORIES Ø D B C Size ØD A B C 100 80 35 10 125 80 35 10 160 80 35 10 200 80 35 10 250 100 45 10 315 100 45 10 400 162 75 12 500 162 75 12 630 130 75 12 Extension piece FLD-aaa-1 GRILLE FND-AAAA-1-1 Size (diameter mm) 100, 125, 160, 200, 250, 315, 400, 500, 630 Grille FND-aaaa-1-1 Size (diameter mm) 0100, 0125, 0160, 0200, 0250, 0315, 0400, 0500, 0630 ØD

6 ESAR Smoke control damper Technical catalogue DAMPER MOTOR WIRING DIAGRAM FOR DAMPER MOTOR Wiring of the actuator has to be done inside the fire resistant calcium-silicate box, since the cable delivered with the actuator is non fire resistant. The wiring of ESAS smoke control damper must always be done using fire resistant cables and switch boxes in order to guarantee the damper s operation in case of fire. ACTUATOR ELECTRICAL DATA Toimilaitteen jännite Maksimi teho pito / ajo Tehontarpeen mitoitus 24V AC/DC 0,5 W / 12 W 18 VA 230V AC 0,5 W / 8 W 15 VA L1-L2 open (90 ) L1-L3 closed (0 ) N L1~ + T AC 230 V AC 24 V DC 24 V Closed (<3 ) Open (>87 ) Contact between Contact between S1-S2 S4-S6 1 2 3 S1 S2 S3 S4 S5 S6 <3 <87

Technical catalogue ESAR Smoke control damper 7 DESCRIPTION AND INSTALLATION DESCRIPTION Smoke contol damper ESAR Fläkt Woods Smoke Control Damper ESAR for Single Compartment smoke control systems With factory mounted safety actuator, which is placed inside fire resistant calcium-silicate box Opening and closing with electrically driven actuator 24 V or 230 V Fire tested and CE marked according the harmonised product standard EN 12101-8 Fire class according to EN 13501-4; E600 120 (ve i <-> o) S1000C300MAsingle Fläkt Woods ESAR fullfills the requirements for MA class for opening / closing (25 min, 600 C) Suitable both for AA and MA smoke control systems INSTALLATION Installation instructions from Fläkt Woods has to be followed to be able to fulfill fire classification. The duct outlet must be placed so that the extraction damper is protected from water coming from outside as well as ice and snow that could hinder the opening of the damper. The ductwork section between the smoke extraction damper and duct outlet must be designed and insulated so that the fire resistance and tightness requirements are met. Also take account of possible condensation.

FWG-Fire damper-esar-technical data-en-2017.03.15 9417EN Copyright 2017 Fläkt Woods Group WE BRING BETTER AIR TO LIFE WWW.FLAKTWOODS.COM ESAR 9417EN 20170315 With over a century of innovation and expertise to share with our customers, Fläkt Woods is a global leader in Air Technology products and solutions. We specialize in the design and manufacturing of a wide range of products and solutions for Air Movement, Air Treatment, Air Distribution, Air Management and Air Diffusion with focus on two major benefits Air Comfort and Fire Safety. With market presence in 65 countries we are in a unique position to be a local supplier and an international partner in our customer s projects. Our product brands such as SEMCO, eq, eq Prime, JM Aerofoil, Econet, Veloduct, Optivent, Optimix, Econovent and Cleanvent are well-known and trusted by customers all over the world to deliver high quality and energy efficient solutions.» To learn more about our offering and get in contact with your nearest sales representative please visit www.flaktwoods.com