GEBRAUCHS- UND MONTAGEANLEITUNG OPERATING AND INSTALLATION INSTRUCTIONS NOTICE D UTILISATION ET DE MONTAGE GEBRUIKS- EN MONTAGEAANWIJZING

Similar documents
OPERATION General information 16 safety instructions 16 Other symbols in this documentation 17 Units of measurement 17. general safety instructions 19

Instantaneous water heater - Operation and installation instructions

SHOWER WATER HEATER MODEL X-SLIM 35 EC / X-SLIM 45 EC OPERATION AND INSTALLATION INSTRUCTIONS

Instructions for use and installation Cooker Hood. Istruzioni per l uso e l installazione Cappa. Mode d emploi et installation Hotte de Cuisine

INDICE CONSIGLI E SUGGERIMENTI... 5 CARATTERISTICHE... 6 INSTALLAZIONE... 7 USO... 9 MANUTENZIONE... 10

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

Flow Factor ~

Libretto di Istruzioni Instructions Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instruções

Instructions for use and installation Cooker Hood. Istruzioni per l uso e l installazione Cappa. Mode d emploi et installation Hotte de Cuisine

Instructions for use and installation Cooker Hood. Istruzioni per l uso e l installazione Cappa. Mode d emploi et installation Hotte de Cuisine

Instructions for use and installation Cooker Hood. Istruzioni per l uso e l installazione Cappa. Mode d emploi et installation Hotte de Cuisine

Instructions for use and installation Cooker Hood. Istruzioni per l uso e l installazione Cappa. Mode d emploi et installation Hotte de Cuisine

OPERATING AND INSTALLATION MANUAL

OPERATING AND INSTALLATION MANUAL

Installation guide VAQ E. Before installing read this guide first

Instructions Manual Manuel d Instructions Bedienungsanleitung Manual de instrucciones Εγχειρίδιο οδηγιών Руководство по эксплуатации

ЭКСПЛУАТАЦИЯ И МОНТАЖ ПРОТОЧНЫЕ ВОДОНАГРЕВАТЕЛИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ

Installation guide COMBI E. Before installing read this guide first

GY11. Dachentlüfter mit Motor Montage- und Bedienungsanleitung. 6. Roof vent with motor Installation and Operating Manual.. 13

Downloaded from

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

The Classeq under counter range

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

4 liter Solo and 8 liter Combi

INSTANTANEOUS ELECTRIC SHOWER

Installation guide COMBI. Before installing read this guide first

Installation guide PRO7-VAQ E. Before installing read this guide first

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Zen Boiling Tap Range

DEUTSCH Gebrauchsanweisung Seite 4 ENGLISH Instructions for use Page 11 FRANÇAIS Mode d emploi Page 18 NEDERLANDS Gebruiksaanwijzing Pagina 25

The Classeq pass Through range

Diamond Cut 360 Cordless Jug Kettle Cool Touch Plastic

Installation & Operators Manual

Hot water wherever and whenever you need it

Händetrockner Hand dryer Sèche-mains Handendroger Osoučeč rukou Suszarka do rąk Сушилки для рук Kézi szárító

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Autofill counter top water boiler

TECHNICAL PROPERTIES OF THE APPLIANCE

GB24 & GB30. User Manual

UPUTE ZA UGRADNJU I UPORABU

Unvented Electric Water Heater 10/15 litre Undersink

DA

OPERATION AND INSTALLATION

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

ELECTRIC CENTRAL HEATING FLOW BOILER

Aqua & Instantaneous Electric Shower Installation Instructions SERVICE POLICY

Mira Atom ERD Thermostatic Bar Valve

CONTENT PAGE INFORMATION INSTALLATION BREWER SETUP BREWING CLEANING KEY BREWER GRINDER MANUAL MODE DILUTION GRINDER MODE PACKS MODE

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

HOT WASHER MODEL NO: KING150

ACCESS.

ULTRAGLISS

REPLACING THE BRITA MEMO

TH100 Three in One Instant Hot Water Tap

Please read and keep these instructions for future use

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

DIGITAL MODULATING BOILERS

User Instruction Manual

FV26XX UK_110x154 19/01/16 11:27 Page1 EN ULTRAGLIDE Anti-Calc

User Instruction Manual

Installation, Operating and Servicing Instructions

Installation guide PRO3-VAQ. Before installing read this guide first

One Cup. Please read and keep these instructions for future use

INSTRUCTION MANUAL (English version) Water still

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

VIESMANN. Installation and service instructions. EHE immersion heater. for contractors. EHE immersion heater

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

AQUA PREMIER ELECTRONIC ELECTRIC SHOWER. Installation and User Guide

Friwa Compact. Operating instructions EN

USER INSTRUCTION MANUAL. Autofill Wall Mount Boilers /12/14

T550i power shower pump Installation and operating instructions

The guarantee on this appliance is valid for 12 months from the first day of installation.

USER INSTRUCTION MANUAL. Autofill Water Boiler

Installation & Operators Manual

Mira Advance THERMOSTATIC ELECTRIC SHOWER. 8.7 and 9.8 kw. These instructions must be left with the user. User Guide W5-A

Safety and Instruction Manual

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

Logic+ Combi

Instructions for use

MEGAFLO HE Iss 1

Installation guide PRO3. Before installing read this guide first

USER GUIDE LOGIC HEAT H

product safety Please read these instructions before operating the appliance and retain them for future use.

Exclusions. Disclaimer

4L Instant Water Boiler Instructions for Use

illuminated filter kettle

Mira Sport Max with Airboost

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - HW

ZIP InLine. Models: ES3, ES4 & ES6. Electronic Instantaneous Water Heaters. ES3, ES4 & ES6 Instructions. V1.09 Page 1 November / 2015

HINTS AND TIPS Cleaning and maintenance HELPLINE

Calomax Limited Lupton Avenue, Leeds LS9 7DD Tel Fax

USERS GUIDE 24, 30. For installation guide see reverse of book

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

IMPORTANT SAFEGUARDS Ensure that your mains supply voltage is the same as that marked on the underside of your kettle.

TCH 2000 E OPERATING MANUAL DESIGNER GLASS CONVECTOR TRT-BA-TCH2000E-TC-001-EN

Transcription:

GEBRAUCHS- UND MONTAGEANLEITUNG OPERATING AND INSTALLATION INSTRUCTIONS NOTICE D UTILISATION ET DE MONTAGE GEBRUIKS- EN MONTAGEAANWIJZING KEZELÉSI ÉS SZERELÉSI UTASÍTÁS GESCHLOSSENER (DRUCKFESTER) WARMWASSERSPEICHER CLOSED (PRESSURIZED) WATER STORAGE HEATER BALLON D EAU CHAUDE FERMÉ (À ÉCOULEMENT LIBRE) GESLOTEN (DRUKBESTENDIGE) WARMWATERBOILER WODY ZÁRT (NYOMÁSOS) MELEGVÍZTÁROLÓ» SH 0 SL comfort» i comfort 7987

Deutsch Seite 4-8 Inhaltsverzeichnis. Gebrauchsanleitung 4. Gerätebeschreibung 4. Das Wichtigste in Kürze 4.3 Bedienung 4.0 Wichtige Hinweise 4. Pflege und Wartung 4.6 Was tun wenn...? 4.7 Sonderzubehör 4. Montageanleitung. Geräteaufbau. Gerätebeschreibung.3 Technische Daten.4 Vorschriften und Bestimmungen. Wichtige Hinweise.6 Montageort.7 Gerätemontage.8 Erstinbetriebnahme.9 Servicehinweise 3. Störungsbeseitigung 7 4. Umwelt und Recycling 7. Kundendienst und Garantie 8 Nederlands bladzijde 8- Inhoudsopgave. Gebruiksaanwijzing 8. Beschrijving van het toestel 8. In kort bestek 8.3 Bediening 8.4 Belangrijke instructies 8. Reiniging en onderhoud 8.6 Wat te doen, indien...? 8.7 Speciale accessoires 8. Montageaanwijzing 9. Opbouw van het toestel 9. Beschrijving van het toestel 9.3 Technische gegevens 9.4 Voorschriften en bepalingen 9. Belangrijke instructies 9.6 Plaats van montage 9.7 Montage van het toestel 9.8 Eerste inbedrijfsname 9.9 Service-instructies 9 3. Verhelpen van storingen 4. Millieu en recycling. Garantie Magyar oldal 30-33 Tartalomjegyzék. Kezelési utasítás 30. Készülék leírása 30. A legfontosabbak röviden 30.3 Kezelés 30.4 Fontos utasítások 30. Tisztítás és karbantartás 30.6 Mit tegyenek, ha 30.7 Zvláštní příslušenství 30. Szerelési utasítás 3. A készülék felépítése 3. A készülék leírása 3.3 Műszaki adatok 3.4 Előírások és meghatározások 3. Fontos figyelmeztetések 3.6 A felszerelés helye 3.7 A készülék felszerelés 3.8 Első üzembe helyezés 3.9 Szervízelőírások 3 3. Hibaelhárítás 33 4. Környezet és újrahasznosítás 33. Garancia 33 English page 0-3 List of contents. Operating Instructions 0. Description of Unit 0. The most important points in brief 0.3 Operation 0.4 Important Note 0. Care and Maintenance 0.6 What to do if... 0.7 Sonderzubehör 0. Installation Instructions. Unit Type. Description of Unit.3 Technical Data.4 Regulations and Conditions. Important Notes.6 Installation Site.7 Unit Installation.8 Initial Use.9 Service Notes 3. Defect Rectification 3 4. Environment and recycling 3. Guarantee 3 Polski strona - Spis treści. Instrukcja obsługi. Opis urządzenia. Ważne wskazówki w skrócie.3 Obsługa.4 Ważna wskazówka. Konserwacja i czyszczenie.6 Co robić, gdy...?.7 Osprzęt dodatkowy. Instrukcja montażu 3. Budowa urządzenia 3. Opis urządzenia 3.3 Dane techniczne 3.4 Przepisy i zalecenia 3. Ważne wskazówki 3.6 Miejsce montażu urządzenia 3.7 Montaż urządzenia 3.8 Pierwsze uruchomienie 3.9 Wskazówki serwisowe 4 3. Usuwanie usterek 4. Środowisko naturalne i recykling. Gwarancja 34 34 34 34 34 34 34 34. 3 3 3 3 3 3 3 3 3 36 37 37 37 Français page 4-7 Sommaire. Instructions d utilisation à l usage 4. Description de l appareil 4. Sommaire des informations essentielles 4.3 Utilisation 4.4 Observations importantes 4. Entretien et maintenance 4.6 Que faire si? 4.7 Accessoires spécifiques 4. Instructions de montage. Composants de l appareil. Description de l appareil.3 Caractéristiques techniques.4 Normes et réglementations. Remarque importante.6 Lieu de montage.7 Montage de l appareil.8 Première mise en service.9 Instructions de maintenance 3. Dépannage 7 4. Environment et recyclage 7. Garantie 7 Česky strana 6-9 Obsah. Návod k použití 6. Popis přístroje 6. Nejdůležitější informace ve zkratce 6.3 Obsluha 6.4 Důležité pokyny 6. Ošetřování a údržba 6.6 Co dělat, když...? 6.7 Zvláštní příslušenství 6. Instrukce k montáži 7. Konstrukce přístroje 7. Popis přístroje 7.3 Technická data 7.4 Předpisy a ustanovení 7. Důležité pokyny 7.6 Montážní místo 7.7 Montáž přístroje 7.8 První uvedení do provozu 7.9 Pokyny pro servis 7 3. Odstraňování závad 9 4. Ekologie a recyklace 9. Záruční podmínky 9

A 8 Typ SH 0 SL i a 7 mm 9 mm b 9 mm 36 mm 6 7 d 00 mm e 387 mm h 03 mm i 6 mm 00 mm 49 mm 60 mm 06 mm 4 3 C6_0_06_00 B C I. II. 6_0_06_0008 D E L L L L SH 0 SL 60 mm 0 mm i -,0 kw 00 mm 30 mm i - 3,3 kw 00 mm 30 mm 6_0_06_0 C486.0 C487.0 F G b a c 6_0_06_06 d 6_0_06_07 3

. Operating Instructions for the user and engineer. Description of Unit The closed (pressurized) water storage heater keeps the water content permanently ready at the pre-selected temperature. Only tap fittings in conjunction with the KV 307 or KV 40 safety group may be used.. The most important points in brief Set the desired hot water temperature using the temperature selector () An illuminated display () indicates that the unit is heating up. C6_0_06_009.3 Operation Temperature setting C = cold. At this setting the unit, but not the fitting or water pipe, is protected from frost Eco = At this setting the unit is protected from frost, although this does not protect the fitting or the water pipe. 8 = max. temperature setting. Note: On request, the engineer can set a temperature limit on the unit (see.8 First Use ) so that the temperature is fully adjustable up to this limit. Heat up time: If the entire water content is used, the heat up time is as indicated in the graph. [min] 40 3 30 0 0 0 3 C C E 6 C 8 C i kw SH 0 SL kw 3,3 kw i Example SH 0 SL : Temperature setting: 6 C Heat up time: approx. 8 minutes Mixing water quantity: Using the temperature, you set a mixed water quantity for e.g. 40 C. [ l ] 4 40 3 30 0 0 0 40 C C E 6 C 8 C Example SH 0 SL : Temperature setting: 6 C Cold water feed: C Mixed water quantity: approx. 0 l.4 Important Note i SH 0 SL The water storage heater is under mains water pressure. During heating up, water will drip out of the safety valve. If water continues to drip out of the safety valve after heating up has been completed, the device must be switched off and depressurized, and a qualified installer called. The blow-out line of the safety valve must not be closed. With temperature settings over 4 C, water at a high temperature may start flowing immediately. If it is intended that children or people with restricted physical, sensory or mental capabilities are to operate the appliance, they must only be permitted to do so after appropriate instruction has been provided by the person responsible for their safety. Children should be supervised to ensure that they do not play with the device. Risk of scalding! To avoid risk of accidental resetting of the protective temperature restrictor in the event of a fault, the unit must not be connected via a timer switch. Limescale can block the outlet and cause pressure to build up in the heater. Signs of limescale are boiling sounds and reduced water flow. In such a case, the unit and fitting must be descaled by an engineer. The thermostat knob may only be removed by an engineer. All information in these Operating and Installation Instructions must be observed. The instructions contain important information for safety, operation and maintenance of the unit.. Care and Maintenance To clean the unit, simply wipe with a damp cloth. Do not use abrasive or aggressive cleaning agents. Maintenance work should only be performed by an engineer..6 What to do if...... there is no hot water: Check the thermostat, plug and fuse....there is a boiling sound from the unit: Have the unit and fitting descaled by an engineer.... see also 3. Defect rectification for the user and engineer. If an engineer is called out for a problem, to help him resolve this problem quickly and efficiently, please give him the information on the unit rating plate, as shown below (8):....7 Sonderzubehör Stiebel Eltron Bestell-Nummern: safety group KV 307 (0.7 MPa) 00 07 7 KV 40 (0.6 MPa) 00 08 8 C6_0_06_004 installation kit "Permanent electrical connection" installation kit 3 9 0

. Installation Instructions for the engineer Installation and electrical connection may only be carried out by an engineer in accordance with these instructions.. Unit Type A Temperature selection knob Indicator light 3 Cold water connection (blue) 4 Hot water connection (red) Electrical cable 6 Suspension rail 7 Electric heating element with protective pipe for thermostat and temperature limiter 8 Rating plate. Description of Unit Closed (pressurized) hot water heater for oversink mounting for supplying one or more taps, for the heating of cold water in accordance with EN 806. Operation is only permissible with tap fittings in conjunction with the KV 307 or KV 40 safety group..3 Technical Data Current data on the rating plate. Type SH 0 SL i i Nominal capacity 0 l l l Type of construction closed Permissible 0.7 MPa operating overpressure Test pressure.4 MPa (untreated tank) Weight 7.6 kg 0. kg 0.8 kg Heating capacity kw kw 3,3 kw Voltage 30 V Flow rate, max. 0 l/min l/min Protection to IP 4 D EN 609 Electrical cable 60 mm with plug approx. Temperature setting range approx. 3 C - 8 C (fully adjustable) Table.4 Regulations and Conditions Perfect function and operating safety can only be guaranteed with the original Stiebel Eltron accessories and spare parts designed for the unit. The fitting outlet serves for ventilation. Do not block the outlet connector or fitting swivel arm. Do not use a perlator or hose with jet regulator. Electrical connection - Plug connection: An earthed socket is required. This must be freely accessible after the device has been installed. If country-specific plugs and sockets are used, they must be fitted with an earthing contact and must conform to the individual national standards. - Fixed connection: If the appliance is instended to be connected to the AC mains (appliance connection socket), it must be capable of all-pole disconnection from the mains by means of a circuit sever of at least 3 mm. SH 0 SL : Installation with a direct (fixed) electrical cable is not permitted. and i: Installation with a fixed connection cable is only permitted in conjunction with the installation kit "Permanent electrical connection" (Stiebel Eltron order no. 3 9). Only with this installation kit is protection class IP 4 D retained. The conditions of the local electricity supply company and competent water supply authority must be observed.. Important Notes If the water connections on the unit are transposed, the unit will not function and the components may be damaged. The operating over-pressure of 0.7 MPa must not be exceeded. Install the KV 307Hsafety group in the cold water connection, up to max. 0.6 MPa at the appliance connection. The KV 40 I safety group (with pressure reducer) can be set up to MPa; setting of max. 0.48 MPa at the appliance connection. The blow-out line of the safety group must be laid with a fall gradient. Regular maintenance and actuation of the safety device is required (see Instruction leaflet for the safety group)..6 Installation Site B The storage tank must be installed in a frostfree place, upright, with the water connections at the bottom, close to the tap from which hot water will most frequently be drawn..7 Unit Installation B Fit the hanging bracket, determining the position with the aid of the mounting template provided. Select fixing materials according to the strength of the wall. Surplus cable can be stored in the cable holder provided. Suspend the unit. Fit water connections with surface sealing. Connections to the heater: right blue = cold water connection (3) left red = hot water connection (4). Set the flow volume at the valve of the KV 307 / KV 40 safety group at max. 0 l/min. for the SH 0 SL(i), and l/min. with the (i). Provide the hot water pipe with thermal insulation (concealed). Pipe material: Cold water pipe Hot water pipe Copper pipe Copper pipe Steel pipe Copper pipe Note regarding plastic pipe systems: Operating temperatures of up to max. 8 C can be set for the heaters. The maximum temperature can be set to 6 C. In the event of a fault, temperatures of up to 0 C may occur. The plastic pipe system used must be designed for these conditions..8 Initial Use C (May only be performed by the engineer!) I. Open the hot water tap or set the onehand mixer tap to warm until the water runs freely with no air bubbles. II. Check the safety valve. During bleeding, a full jet of water must run out. III. Connect the electrical plug and select the temperature. Risk of running dry! If the sequence is confused, the temperature limiter will actuate. In such a case, the thermostat must be replaced and the limiter must be made ready for operation again by pressing the reset button. IV. Temperature setting restrictor F : Only if the restricted temperature setting is required is the max. temperature set via the restrictor ring. To do this, pull off the thermostat knob and restrictor ring. Set the restrictor ring to the desired max. setting and push the thermostat knob back on. V. Remove protective film from controls. Unit hand-over: Explain to the user how the unit works and how to operate it. Point out any possible dangers (scalding). Give the user these Installation and Operating Instructions for safe keeping..9 Service Notes Open unit G : a Pull off thermostat and temperature restrictor ring. Remove screw. b Lower locking bolt c Swivel housing cover aside and remove. d Open clamp band (protection against tilting). Replace electrical cable: To replace the connecting cable, use Stiebel Eltron. kw: Order no. 0 06 7, or with an H0VV-F3x.0 cable 3.3 kw: Order no. 0 39 7, or use an H0VV-F3x. cable. Lay the connecting line in the channelg()! Circuit diagramd Positioning the thermostat/temperature limiter sensor in the protection pipe: When replacing or dismantling the temperature regulator/limiter, the sensors must be introduced into the protection pipe. Drain unit: The unit is drained via the connector. English

Descaling: Remove heating flange, remove coarse scale by careful tapping, immerse heating element in limescale remover up to the flange plate. Checking earth conductor in accordance: Disconnect the plug and remove the thermostat. Test at the thermostat fixing screw and earth contact of the connection cable. H 6 KV 307 3 4 Safety valve Non-return valve 3 Check valve 4 Throttle 6 Connection point for manometer 7 Funnel with odour trap C6_0_06_0 6 3 / 4 7 C6_0_06_04 I 6 KV 40 3 4 Safety valve Non-return valve 3 Check valve 4 Throttle Pressure reducing valve 6 Connection point for manometer 7 Funnel with odour trap C6_0_06_03 6 3 / 4 7 C6_0_06_0

3. Defect Rectification for the user and engineer Defect Cause Solution No hot water despite hot water tap being fully open. No power. User / Engineer: Check fuses on domestic system. Limescale on jet regulator. User / Engineer: Clean or replace jet regulator on fitting. Temperature limiter (STB) has actuated. Engineer: Boiling sound in heater. Limescale in heater. Engineer: Descale unit. Table Rectify the cause of the fault (replace thermostat) and make the limiter ready for operation again by pressing the reset button. 4. Environment and recycling English. Guarantee For guarantees please refer to the pespective terms and conditions of supply for your country. The installation, electrical connection and initial operation of this appliance should be carried out by a qualified installer. The company does not accept liability for failure of any goods supplied which accor-dance with the manufacturer s instructions. 3