TECHNICAL SPECIFICATIONS

Similar documents
TECHNICAL SPECIFICATIONS

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

PROVIDING HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

AND WORRY-FREE PERFORMANCE

Condensing Units & Air Handlers

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

13 SEER CONDENSING UNITS & AIR HANDLERS

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

PRODUCT SPECIFICATIONS

TECHNICAL SPECIFICATIONS B6VMMX

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Commercial High-Efficiency Condensing Units

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

WCH5**4. Product Specifications

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

2 shp 13 lc 1 36 t - 1 a

AND WORRY-FREE PERFORMANCE

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

R4H4. Product Specifications

Table of Contents AIR CONDITIONING EQUIPMENT

AND WORRY-FREE PERFORMANCE

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

16 SEER TWO-STAGE AIR CONDITIONERS

R4H4. Product Specifications

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

MAC N-407 Air-Cooled Chiller

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL SPECIFICATIONS

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

MACH N-407 Heat Pump Air-Cooled Chiller

MERIT SERIES Up Flow / Horizontal

13 GEP A L P - 1 A

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Specifications and Performance S2H

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

13 SEER HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

MERIT Series R-410A - Upflow / Horizontal

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

MERIT Series R-410A - Upflow / Horizontal

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

13 SEER CONDENSING UNITS

N4H4. Product Specifications

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

PRODUCT SPECIFICATIONS

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

TECHNICAL SPECIFICATIONS

RTG Ultron. Up to 16 SEER. Specification Sheet. Split System Heat Pump

TECHNICAL SPECIFICATIONS

Commercial High-Efficiency Condensing Units

RSG16**S1M. Split System Air Conditioner 16 SEER

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

AND WORRY-FREE PERFORMANCE

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning


Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

WJH4 Product Specifications

Split System Cooling Product & Performance Data

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

RGE 13 A T - 1 A

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

PRODUCT SPECIFICATIONS

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

14 AC x

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Split System Cooling Product Data

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Split System Cooling Product Data

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Transcription:

TECHNICAL SPECIFICATIONS Model DT4BD Series M120 Product Line High Efficiency R-410A Heat Pump 13 SEER 1.5-5 Ton

12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace the unit if the compressor fails in the first year of operation, to the original owner. All split system products must be installed with a matched indoor air handler or indoor coil to qualify. Product registration required for 12-year All Parts Warranty and Dependability Promise within a limited period of time after the installation. See current warranty document for details. This can be viewed at www.maytaghvac.com or ask your sales representative. Maytag now offers the choice of a heat pump that uses a more efficient and environmentally friendly refrigerant designated R-410A. The DT4BD Series of heat pumps offers exceptional performance. The unit, when combined with our engineered coils or air handlers, offers a full line of quality, split system cooling equipment. Features and Benefits SmartCool TM 410 TM Refrigerant (R-410A) Earth friendly non-ozone depleting refrigerant. Designed using galvanized steel with a polyester urethane coat finish. The 950 hour salt spray finish resists corrosion 50% better than comparable units. Copper Tube / Aluminum Fin Coils Both indoor and outdoor coils are designed to optimize heat transfer, minimize size and cost, and increase durability and reliability. Permanently Lubricated Motor A heavy duty PSC motor for long lasting reliability and quiet operation. Requires no maintenance and is completely protected from rain and snow. Full Port Suction Valve Full port brass suction valve provides low pressure drop and ease of service. The valve is actuated by 1/4 turn full open to full close. Steel Guard TM Durable metal guard protects the coil from yard hazards and extreme weather. Removable Top Grille Assembly Allows ease of service from the top without disconnecting fan motor leads. High Pressure Switch Protects against abnormally high system pressures. Auto-reset feature prevents nuisance service visits. Liquid Line Filter Drier Included with unit, field installed. One Piece Top/Orifice Designed for maximum airflow and quiet operation. 2-1/2 Pedestal Base The sturdy base keeps the bottom of the coil out of harms way. Secondly, the base has weep holes along the edge to allow the water from rain to flow away from the unit. Easy Compressor and Control Access Designed to make servicing easier for the contractor, access panels are provided to all controls and the compressor from the side of the unit. 3

DIMENSIONS/OUTDOOR SECTION DT4BD 018K 024K 030K 036K 042K 048K 060K H 30 1/2 34 1/2 38 1/2 42 1/2 38 1/2 42 1/2 42 1/2 W 30 1/2 30 1/2 30 1/2 30 1/2 30 1/2 30 1/2 30 1/2 D 30 1/2 30 1/2 30 1/2 30 1/2 30 1/2 30 1/2 30 1/2 Air Discharge Allow Adequate Clearance for Airflow D W H IDENTIFICATION CODE EX: DT4BD-036K D T 4 B D - 036 K D = Steel Guard TM Product Identifier Nominal (000) BTU Electrical Code K = 208/230-60-1 T = Heat Pump Design Series BD = Braze 13 SEER 4

PHYSICAL AND ELECTRICAL SPECIFICATIONS / OUTDOOR UNITS 13 SEER High Efficiency Single Phase DT4BD Electrical Data Condenser Data Weight Approximate (lbs.) Volts-Cycles-Phase (1) Total Amps Delay Fuse Max. (2) Min. Circuit Ampacity Coil Fan Motor Fan Blade Compressor Data Refrigerant suction line O.D.(all length of liquid line are 3/8" O.D.) Refrigerant charge (R-410A) in ounces for outdoor unit, indoor unit and 15' lineset. (1) Operating Voltage Range: 187v min. 253v max. (2) HACR Type Circuit Breakers may be used. (3) Requires 7/8" to 1-1/8" adapter from unit to line. 018K 024K 030K 036K 042K 048K 060K 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 9.96 14.44 15.08 17.64 19.32 23.16 27.64 20 30 30 35 40 45 50 12.2 17.8 18.6 21.8 23.8 28.6 34.2 Area 17.5 20.3 22.8 25.4 22.8 25.4 25.4 Rows-FPI 1-20 1-20 1-20 1-20 2-16 2-16 2-16 Tube Dia 3/8" O.D. 3/8" O.D. 3/8" O.D. 3/8" O.D. 3/8" O.D. 3/8" O.D. 3/8" O.D. Type PSC PSC PSC PSC PSC PSC PSC Amps 1.0 1.0 1.0 1.0 1.4 1.4 1.4 Watts-HP 0.25 0.25 0.25 0.25 0.25 0.25 0.25 Dia-# Blades 24"- 2 24"- 2 24"- 2 24"- 2 24"- 2 24"- 2 24"- 2 SCFM 3000 3200 3300 3400 3700 3800 3800 RLA 10 15 15.7 18.6 20 24.3 29.3 LRA 48 58.3 73 79 112 117 134 0-24 ft. 3/4" 3/4" 3/4" 7/8" 7/8" 7/8" 7/8" 25-39 ft. 3/4" 3/4" 3/4" 7/8" 7/8" 7/8" 1-1/8" (3) 40-75 ft. 3/4" 3/4" 3/4" 7/8" 7/8" 7/8" 1-1/8" (3) 112 138 145 168 243 248 248 Net 166 171 176 181 247 280 290 Ship 175 180 185 190 260 295 305 COPPER WIRE SIZE AWG (1% Voltage Drop) Supply Wire Length-Feet Supply Circuit 200 150 100 50 Ampacity 6 8 10 14 15 4 6 8 12 20 4 6 8 10 25 4 4 6 10 30 3 4 6 8 35 3 4 6 8 40 2 3 4 6 45 2 3 4 6 50 Wire Size based on N.E.C. for 60 type copper conductors. 5

SYSTEM COOLING CAPACITIES 13 SEER High Efficiency Single Phase Outdoor Unit Indoor Unit Cooling Heating Nominal DT4BD- C6B(A,H)- Btuh SEER EER BTUH @ 47 F HSPF SCFM 024K X24(C,U)-A + MB6BM 23,800 13 12.5 23,800 8.0 750 024K X24(C,U)-B + MB6BM 23,800 13 12.5 23,800 8.0 750 030K X30(C,U)-A + MB6BM 28,400 13 12.0 29,400 7.8 800 030K X30(C,U)-B + MB6BM 28,400 13 12.0 29,400 7.8 800 036K X36(C,U)-A + MB6BM 35,600 13 12.0 36,000 8.0 1100 036K X36(C,U)-B + MB6BM 35,600 13 12.0 36,000 8.0 1100 042K X42(C,U)-B + MB6BM 42,000 13 13.0 42,000 8.0 1325 042K X42(C,U)-C + MB6BM 42,000 13 13.0 42,000 8.0 1325 048K X48(C,U)-C + MB6BM 48,000 13 11.7 47,000 8.0 1675 048K X48(C,U)-D + MB6BM 48,000 13 11.7 47,000 8.0 1675 060K X60(C,U)-C + MB6EM 57,000 13 12.0 55,000 8.0 1850 060K X60(C,U)-D + MB6EM 57,000 13 12.0 55,000 8.0 1850 Outdoor Unit Indoor Unit Cooling Heating Nominal Indoor DT4BD- C5B(A,H)- Btuh SEER EER BTUH @ 47 F HSPF SCFM Orifice 018K (0,X)24(U,C)-A 18,000 13.0 11.0 18,000 8.0 650.050 024K (0,X)24(U,C)-(A,B) 23,600 13.0 12.6 23,600 8.0 750.055 030K (0,X)30(U,C)-(A,B) 29,400 13.0 12.0 30,000 8.0 850.065 036K (0,X)36(U,C)-B 35,400 13.0 11.8 36,000 8.0 1200.073 042K (0,X)42(U,C)-B 39,600 13.0 11.7 41,000 8.0 1400.077 048K (0,X)48/49(U,C)-(B,C) 48,000 13.0 12.0 48,000 8.0 1600.080 060K (0,X)60(U,C)-C 59,500 13.0 11.7 58,000 8.0 1750.089 Outdoor Unit Indoor Unit Cooling Heating Nominal Indoor DT4BD- B5B(M,V)- Btuh SEER EER BTUH @ 47 F HSPF SCFM Orifice 018K (0,X)24K-A 18,000 13.0 11.0 18,000 8.0 650.050 024K (0,X)24K-(A,B) 23,600 13.0 12.6 23,600 8.0 750.055 030K (0,X)30K-(A,B) 29,400 13.0 12.0 30,000 8.0 850.065 036K (0,X)36K-B 35,400 13.0 11.8 36,000 8.0 1200.073 042K (0,X)42K-B 39,600 13.0 11.7 41,000 8.0 1400.077 048K (0,X)48/49K-C 48,000 13.0 12.0 48,000 8.0 1600.080 060K (0,X)60K-C 59,500 13.5 11.7 58,000 8.0 1750.089 See current ARI Directory for certified combinations and ratings. 6

SYSTEM COOLING CAPACITIES (Continued) 14 SEER High Efficiency Single Phase Cooling See current ARI Directory for certified combinations and ratings. Heating BTUH @ 47 F Nominal Indoor Btuh SEER EER HSPF SCFM Orifice 018K (0,X)24(C,U)-B+VSB-B 18,400 14 12.9 18,000 8.0 600 0.050 024K (0,X)24(C,U)-B+VSB-B 24,000 14 13.4 23,200 8.5 750 0.055 030K (0,X)30(C,U)-B+VSB-B 29,600 14 12.9 29,600 8.5 900 0.065 036K (0,X)36(C,U)-B+VSB-B 35,800 14 12.6 37,800 8.5 1180 0.073 042K (0,X)48/49(C,U)-C+VSB-C 41,500 14 13.5 41,500 8.5 1400 0.077 048K (0,X)48/49(C,U)-C+VSB-C 48,500 14 13.0 47,500 8.5 1600 0.080 060K (0,X)60(C,U)-C+VSB-C 59,500 13.5 12 57,500 8.5 1700 0.089 Cooling Heating BTUH @ 47 F Nominal Indoor Btuh SEER EER HSPF SCFM Orifice 018K (0,X)24KB+VSB-B 18,400 14 12.9 18,000 8.0 600 0.050 024K (0,X)24KB)+VSB-B 24,000 14 13.4 23,200 8.5 750 0.055 030K (0,X)30KB+VSB-B 29,600 14 12.9 29,600 8.5 900 0.065 036K (0,X)36KB+VSB-B 35,800 14 12.6 37,800 8.5 1180 0.073 042K (0,X)48/49KC+VSB-C 41,500 14 13.5 41,500 8.5 1400 0.077 048K (0,X)48/49KC+VSB-C 48,500 14 13.0 47,500 8.5 1600 0.080 060K (0,X)60KC+VSB-C 59,500 13.5 12 57,500 8.5 1700 0.089 Outdoor Unit DT4BD- Indoor Unit C5B(A,H)- Outdoor Unit DT4BD- Indoor Unit B5B(M,V)- Outdoor Unit DT4BD- Indoor Unit B5VM- Cooling Heating BTUH @ 47 F Nominal Indoor Btuh SEER EER HSPF SCFM Orifice 018K (0,X)24K-B 18,400 14 12.9 18,000 8.0 600 0.050 024K (0,X)24K-B 24,000 14 13.4 23,200 8.5 750 0.055 030K (0,X)30K-B 29,600 14 12.9 29,600 8.5 900 0.065 036K (0,X)36K-B 35,800 14 12.6 37,800 8.5 1180 0.073 042K (0,X)48/49K-C 41,500 14 13.5 41,500 8.5 1400 0.077 048K (0,X)48/49K-C 48,500 14 13.0 47,500 8.5 1600 0.080 060K (0,X)60K-C 59,500 13.5 12 57,500 8.5 1700 0.089 ACCESSORIES - CONDENSING UNIT Start Assist Kit - 912933 Provides additional starting torque for the compressor motor when operating with low line voltage or high operating temperatures.

Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Manufactured under license by NORDYNE, O Fallon, MO. Registered Trademark/ TM Trademark of Maytag Corporation or its related companies. 2008. All rights reserved. 049C-0708 (Replaces 049C-1007) Printed in U.S.A. (07/08)