General information and installation instructions for Metal Detectors

Similar documents
Operating Instructions SENSITY Control Unit

Operating Instructions. Boilermag XL Filter. High Intensity Magnetic Separator

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

Installation, Operation and Maintenance Instructions

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

Use and Maintenance Manual. WPA-E-N/Ex. II 2 G c Ex e II T3. ATEX marking: Explosion proof stand fans WPA-E-N/Ex

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

USER S MANUAL ATH WH220

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

TTV 4500 / TTV 4500 HP / TTV 7000

Flameproof Manual Call Points

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

Sanitary Water Tank INSTALLATION & SVC MANUAL

Instructions for: Tower III by Henry Kloss

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

SASE BULL 240C. Dust Collection System Manual

WPA-S-N/Ex. Use and Maintenance Manual. Explosion proof stationary fan. II 2 G c Ex e II T3. ATEX marking:

FlowJam Bulk Flow Detection

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

ATM Lighting sp. z o.o

INSTALLATION INSTRUCTIONS FOR. 230/240 VAC, 1ø, 50Hz 473X3 SERIES RV ROOF TOP AIR CONDITIONER

Flame detector FD 2011 / FD 2012

VEX250H with rotary heat exchanger and EXact control system

DWA2000. WAAS Annunciator. Installation and Operations Manual. Rev 1.0 August 2014

Service: to SLK Laboratory Hot Plates glass made of ideas

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

OPERATION AND MONTAGE MANUAL ROOF FANS

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

SWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

Alfa Laval Arctigo ID

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

Edition 8, From serial no Publ. no OM 5030, Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL)

OPERATION AND MONTAGE MANUAL ROOF FANS

Table of Content

WXHAP Washington Street Melrose, MA Phone Toll Free Visit us at

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

INSTALLATION AM

ATM Lighting sp. z o.o

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Underwood Heater Installation Manual

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

Operating Manual MS220DA

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

EHA Hoffmann International GmbH

ISCG90SS _03 ISCG90SS

The New EMC Directive 2004/108/EC

Bathroom Exhaust Fan

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

Operating Manual MS220KA and MSR220KA

Where Process Safety meets Machine Safety

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

RAYPAK REPLACEMENT INSTRUCTIONS

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

Staff Contact: William F. Mascaro Telephone (703) Item Description Class

VETO CLEANER 500 FLUE GAS CLEANER

Commercial backpack vacuum cleaner

HEAT RECOVERY AIR HANDLING UNIT

MOULD WITH ENTERING PUNCHES

Chef Base Refrigerators

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Snifter ATEX22 VERSION. User Manual. Distributor

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Fiber Optic Cable Fence Disturbance Sensor

Operating Instructions!

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

IMPORTANT SAFETY INSTRUCTIONS

Test Unit GTL 100 for Fire Detectors

MANUAL Overflow sensor NVF-104/34-PF

XB-EFA-8L-BK & XB-EFA-8R-BK

DWA2000. WAAS Annunciator. Installation and Operations Manual. Rev 1.1 December 2014

Register at

Audible warning devices for external alarm

GMA Panels with double busbar

Induction K heater

OPERATIONAL & MAINTENANCE MANUAL Model 7050P Old Style with Dual Troll Bin

Original instructions. Operation Manual & Cautions

www. ElectricalPartManuals. com INSTRUCTIONS DRY TYPE TRANSFORMERS OPERATION AND MAINTENANCE OF

Field Start-Up Sheet Direct Fired Gas Equipment

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

Parts and Service Manual BURNISHER MODEL: MR , MR , MR , MR

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

Installation Manual PS-225 & PS-275

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

INSTALLATION INSTRUCTION

Vertical Stack Fan Coil Units Models: TVA, TVE, TVS

HVAC Module Assembly Replacement. Tools Required. J A Halogen Leak Detector. Removal Procedure

FEC400 Series. Installation Manual

INSTALLATION AM ; AMC

RPI Industries, Inc.

Emotron M10 Shaft Power Monitor. Instruction manual English

INSTRUCTIONS FOR USE

Swaging Machine Type H50-46ECO

Transcription:

General information and installation instructions for Metal Detectors 9-882 96 th Avenue Surrey, BC Canada, V4N 3R Tel: (00) 604 607-6028 Fax: (00) 604 607-6026 e-mail: service@metal-shark.com TecTronix-Metal Detectors-BA-EN-205.doc

Customer Name: Location: Date in Service d/m/y: We would like to take this opportunity to thank you for purchasing your Metal Detector from Tectronix. The confidence you have placed in our product is sincerely appreciated and we will endeavour to provide the best service and support possible. Please take the time to read the User Manual completely as this provides you with the expertise necessary to install and adjust the system according to your requirements. In addition to this, you will learn about the sophisticated options provided by the GENIUS or SENSITY electronics. If you have any problems in the set up and operation of your system, the Tectronix team are available to assist you. Tectronix Systems inc. 9 882 96th Avenue Surrey, British Columbia Canada, V4N 3R Telephone: (00) 604 607-6028 Fax: (00) 604 607-6026 E-mail: service@metal-shark.com 2 TecTronix-Metal Detectors-BA-EN-205.doc

Contents Contents Introduction 4. Fields of applications 4.2 Symbols used 4.3 Legal basis 4.4 Overall view 5 2 Technical data 5 3 Design and method operation 6 3. Functional principle 6 3.2 Combination scopes 7 4 Safety 8 4. Use to the intended purpose 8 4.2 Notifications of danger 8 4.3 Danger in case of non-observance of the maintenance 8 4.4 Safety notes for the operator 8 4.5 Safety notes during operating and maintenance 8 4.6 Consequences of unauthorized modification 8 4.7 Inadmissible operation 8 5 Commissioning 9 5. Mechanical installation 9 5.. OCTAGONAL 0 5..2 REGTANGULAR / SQUARE 0 5..3 FLAT 5..4 VT / ST 5.2 Connections 3 5.2. With Control Unit SENSITY 3 5.2.2 With Control Unit GENIUS 3 6 Maintenance 3 6. Periodic inspection of the coil 3 7 Spare parts / service 4 7. Spare parts drawing 4 7.2 Spare parts list 5 7.3 Service address 6 8 Shipping, transport, storing, preservation 7 3 TecTronix-Metal Detectors-BA-EN-205.doc

. Introduction Introduction. Fields of applications Product liability ISO 9000 TQM (Total Quality Management) Protection of consumers and machines.2 Symbols used = Important notes = Danger notes = Safety notes.3 Legal basis This equipment complies with EMC guideline 89/336/EC and 93/97/EC. This equipment complies with low-voltage guideline 73/23/EC and 93/68/EC. 4 TecTronix-Metal Detectors-BA-EN-205.doc

. Introduction / 2 Technical data.4 Overall view 2 Technical data Housing Weight Ambient temperature Stainless steel housing V2A Depending on dimensions -0 C to 65 C Type of protection Detector head IP 54, Control unit IP 65 Connecting cable Can be combined with (to the control unit) up to 8 m standard Control unit SENSITY or GENIUS Subject to changes due to technical innovation! 5 TecTronix-Metal Detectors-BA-EN-205.doc

3. Design and method of operation 3 Design and method operation 3. Functional principle The material to be inspected (bulk or lump material) passes the detector head (2) on a belt conveyor (). The lower part of the belt can be put also through the detector head (3). 2 3 The material is penetrated within the aperture of the detector head by a high frequent electro-magnetic field, which is generated by the control unit and the transmitter coil. Two identical voltages are induced into the receiver coils, and are subtracted to zero if the system is in balance. 2 4 E S E2 E S E2 A metallic impurity (4) causes an unbalanced condition and the receiver responds. The control unit generates a signal, which triggers an output relay (see operational manual). 6 TecTronix-Metal Detectors-BA-EN-205.doc

3. Design and method of operation 3.2 Combination scopes Different Control units can be used to control the detector head: SENSITY or GENIUS. 7 TecTronix-Metal Detectors-BA-EN-205.doc

4. Safety 4 Safety 4. Use to the intended purpose This equipment is determined to be used with conveyor hoses (-tubes) only in connection with the appropriate control unit (SENSITY, SENSITY-D or GENIUS). 4.2 Notifications of danger People with cardiac pacemaker should not permanently stay in the area of the detection coil. 4.3 Danger in case of non-observance of the maintenance There are no known risks or side effects emanating from the detection coil, if the equipment is not used to its intended purpose. 4.4 Safety notes for the operator If potentially explosive materials are examined, the pertinent regulations must be observed. 4.5 Safety notes during operating and maintenance Safe operation is only guaranteed with closed covers of the connection box. 4.6 Consequences of unauthorized modification In case of unauthorized modification or repair work all the declarations and guarantees given by the manufacturer will become void. 4.7 Inadmissible operation Operation out of the specifications given in the technical data. Operation under high mechanical static or dynamic loads (e.g. heavy system parts or strong vibrations). 8 TecTronix-Metal Detectors-BA-EN-205.doc

5. Commissioning 5 Commissioning 5. Mechanical installation Use only enough stable lifting harnesses for big and heavy detector heads. Take care for a stable and vibration proof mounting! Metal-free zone must be strictly observed! Within the metal-free zone no metallic parts must be situated. For moving metal parts (pusher) the metal-free zone extends. The dimensions of the metal-free zone are given in the attached data sheet. A non metallic slide (plastics or wood) must be used within the aperture as a belt support. The sliding board and also the run back belt underneath should not touch the shaft walls inside of the detector head opening. The recommended gap between slide and detector is min. 0 mm. Do not mount or operate the detector near sources of interferences (electric motors, frequency and current converters). The required distance depends on the aperture size of the detector head and the power of the source of interference. Control unit mounted apart of the detector head: Changes of the connection cables between the detector head and the control unit must be reconfirmed by Tectronix. Only original cables must be used otherwise the CE-certification become un valid. The connections cable must be installed separate from other power and control lines and carefully fixed or laid into a cable duct. Installation of more then one coil: In case that two or more coils are working in adjacent lines interferences can occur. Therefore you need to reconfirm Tectronix. 9 TecTronix-Metal Detectors-BA-EN-205.doc

5. Commissioning 5.. OCTAGONAL Pay attention to the following order when mounting the OCTAGONAL to conveyor: Do not remove the two 6 mm insulation shims or replace them by other materials. This parts are used as electrical insulators.. Disconnect the connection cable (2) (see also 5.2) if necessary when equipped with SENSITY Control Unit. 2. Put the belt and sliding board through the detector opening. Fasten the board and make sure that neither the sliding board nor the belt touches the shaft walls inside of the detector opening. 3. For mounting the detector head use only the insulation shims. 4. Connect connector cable (2) according to picture 5.2. 5..2 REGTANGULAR / SQUARE Pay attention to the following order when mounting the coil to conveyor: Do not remove the plastic bars or replace them by other materials. This parts are not only used as fastening elements but also as an electrical insulator.. If necessary disconnect the connection cable (3) (see also 5.2). 2. Put the belt and sliding board through the detector opening. Fasten the board and make sure that neither the sliding board nor the belt touches the shaft walls inside of the detector opening. 3. For mounting the detector head use only the plastic bars. 4. Connect connector cable (3) according to picture 5.2. 0 TecTronix-Metal Detectors-BA-EN-205.doc

5. Commissioning 2 3 5..3 FLAT Pay attention to the following order when mounting the coil to conveyor: Do not remove the plastic bars or replace them by other materials. This parts are not only used as fastening elements but also as an electrical insulator.. If necessary disconnect the connection cable (3) (see also 5.2). 2. Fasten the sliding board and make sure that neither the sliding board nor the belt touches the surface of the detector opening. 3. For mounting the detector head use only the plastic bars. 4. Connect connector cable (3) according to picture 5.2. 3 2 5..4 VT / ST Pay attention to the following order when mounting the coil to conveyor chute:. If necessary disconnect the connection cable () (see also 5.2). 2. Mount / Install the detector head into the conveyor chute. 3. Connect connector cable () according to picture 5.2. TecTronix-Metal Detectors-BA-EN-205.doc

5. Commissioning 2 2 TecTronix-Metal Detectors-BA-EN-205.doc

5. Commissioning / 6. Maintenance 5.2 Connections If the connection cable between detector head and control unit has been removed reconnect it according to the sketch: 5.2. With Control Unit SENSITY Detection coil Coil connection boxes Receiver 2 3 4 wh gn ye br 2 3 4 Shield outside Housing Sensity Shield outside PCB Sensity Solder gr 7wire EMC-cable Transmitter bl 5 6 7 8 Core bl 6 7 Shield inside gn ye br Core Receiver Shield outside Triax-cable Shield inside Shield outside Transmitter 5.2.2 With Control Unit GENIUS Coil connection boxes Housing GENIUS PCB GENIUS AWE Receiver 2 3 4 wh gn ye br 2 3 4 Solder gr Shield outside 7wire EMC-cable R Detection coil Shield outside wh gn ye br - + Receiver 5V Transmitter bl 5 6 7 8 Core bl 6 7 Shield outside Shield inside Triax-cable gr bl Shield inside Core Shield outside o i T CableCheck Transmitter green = gn blue = bl gray = gr brown = br yellow = ye white = wh 6 Maintenance 6. Periodic inspection of the coil Although the coil is maintenance-free, it is useful to check the equipment periodically: Check for loose bolts or nuts at the plastic bars. Are there any objects laying on the detector head? Are there any objects in the detector passage between slide and detector (remains of bulky goods or accumulated dust)? 3 TecTronix-Metal Detectors-BA-EN-205.doc

7. Spare parts / service 7 Spare parts / service If you should have any questions please state equipment type and serial number! 7. Spare parts drawing OCTAGONAL REGTANGULAR / SQUARE 2 2 FLAT VT / ST 4 TecTronix-Metal Detectors-BA-EN-205.doc

7. Spare parts / service 7.2 Spare parts list POS.NO. ARTICLE ART.NO. REMARKS OCTAGONAL Remathan isulation shims with screws 2 Control unit Electronic connection cable ) (not shown) See appropriate operating instructions REGTANGULAR / SQUARE Mounting elements with screws 2 Control unit FLAT Mounting elements with screws Control unit (not shown) Electronic connection cable ) (not shown) VT / ST Control unit (not shown) Electronic connection cable ) (not shown) See appropriate operating instructions See appropriate operating instructions See appropriate operating instructions ) Please state the cable length when ordering! 5 TecTronix-Metal Detectors-BA-EN-205.doc

7. Spare parts / service 7.3 Service address Manufacturer s: Tectronix Systems inc. 9-882 96th Avenue Surrey, British Columbia Canada, V4N 3R Telephone: (00) 604 607-6028 Fax: (00) 604 607-6026 E-mail: service@metal-shark.com Representative: 6 TecTronix-Metal Detectors-BA-EN-205.doc

8. Shipping, transport, storing, preservation 8 Shipping, transport, storing, preservation. Choose packing that is suitable for type and size of the shipment for export, sea or airfreight, national or international road transport. The packing must be chosen such that under normal transport conditions the goods cannot be damaged. 2. Depending on the size, weight and nature of the goods shipments are only packed suitable for road transport in cartons, carton pallets, etc.. As filling and protection material in the packing reinforced carton, corrugated cardboard, air cushion foil and paper chips are used. Electrostatic sensitive components (electronic boards, electr. modules, etc.) must be packed in antistatic foil or bags prior to packing! ( t h i s i s e s s e n t i a l! ). On the outside of the packing additional warning labels such as: "Attention, electronic equipment, do not throw", etc., must be applied. The packing is sealed with adhesive tape and, in case of weights of more than 50 kg, additionally with wrapping tape. 2a. International road transport shipments are packed in accordance with point 2, larger and heavier shipments depending on the protection they require, are also protected against corrosion inside the packing. Easily corroding parts must be packed in oil-paper or corrosion-protection foil prior to packing. Care must be taken that inside the packing the packed components are protected against slipping. 2b. International air-freight shipments must be packed in wooden crates or in export paltainers. Care must be taken that the goods are well fixed and protected inside the packing. Susceptible parts must be protected against corrosion (oil-paper, protective foil, corrosion spray, etc.). 2c. Sea-freight shipments must be packed in seaworthy export crates. These special crates may be obtained from special manufacturers. The crates must be lined with oil-paper to make them resistant to sea-water and corrosion. In addition the goods must be protected against corrosion by spray or protective foil. Care must be taken that inside the crate the goods are protected against slipping. After packing the sea-freight crates must be properly closed. During loading care must be taken that the shipments are protected. Proper acceptance and loading of the shipment must be certified by the carrier on the bill of loading, loading list, etc.. 7 TecTronix-Metal Detectors-BA-EN-205.doc