Source Test and Characterization Program

Similar documents
IR IN MODERN TECHNOLOGY 1. Infrared Radiation in Modern Technology. Brian D. Dold. Brigham Young University - Idaho

WFC3. TV2 complete: working several solvable issues TV3 starts in February with flight detectors

How SWIR Imaging contributes to the optimization of automatic quality control in the food industry

Stand-off Detection of Trace Explosives by Infrared Photothermal Imaging. Trace Contamination

Broadening IR applications through using spectral filters

Equipment specifications (D6)

Development and setting up a calibration facility for UV sensors at high irradiance rates

An FT-NIR Primer. NR800-A-006

Technical specifications of FT-IR Spectrometer

Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

730NM LED ALTERNATIVES TO INCANDESCENT LAMPS FOR SUPPLEMENTARY FAR RED RADIATION IN GROWTH CHAMBERS

Understanding total measurement uncertainty in power meters and detectors

Diamond Windows & MCP Detectors for Synchrotron Applications

2018 New Infrared Technologies, S.L.

FEE Diagnostics and Commissioning. June 17, 2008

Development of a variable output LED-365 irradiance standard

6340(Print), ISSN (Online) Volume 4, Issue 2, March - April (2013) IAEME AND TECHNOLOGY (IJMET)

GOES-R ABI Emissive IR Bands Radiometric Performance Monitoring and Trending

Lighting Measurement Solutions

CCTV, HOW DOES IT WORK?

EMITTER TECHNICAL DATA

Dated 15-Dec-2000; J. Schilz, subject to change

Development of a Canadian Wildland Fire Monitoring Sensor (CWFMS)

Gemini Instrument Program Status Report. Gemini Science Committee October 12, 2009

Passive Standoff FTIR Detectors as Transducers. Background From radiation to information

The new generation Teledyne NIR detectors for the SNAP/JDEM mission spectrograph.

Chemistry Instrumental Analysis Lecture 4. Chem 4631

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

Construction of a Calibration System for Power Responsivity of Optical detectors Using Different Laser Sources

Wildland fire phenomenology experiments:

MULTI-FUNCTION InGaAs DETECTOR FOR SWIR IMAGING

Flame Simulator User Manual. Publication Rev. A

GOFC/GOLD Fire IT Strategic Planning. Day 1 - Break Out Group Discussion

Publication American Institute of Physics. Reprinted with permission.

Mark Farries. Gooch & Housego

for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications

The Growing Viability of UV LED for Wide Web Coating Applications. Tuesday, October 11, 2016

(PT-A1-AC ) Surface Mount Ambient Visible Light Sensor. Electronics Tech. Direct Electronics Industry Co., Ltd. Version: July 31, 2017

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

FPI Detectors Pyroelectric Detectors with Spectrometer Functionality

Smart Fire Prevention

R&D for the improvement of O&M in CSP plants. Dr. Marcelino Sánchez. - November,

University of Colorado Department of Aerospace Engineering Sciences ASEN Project Definition Document (PDD)

1.1. SYSTEM MODELING

Bernd Eichler Sales Manager

LEARNING SPECIAL HAZARD DETECTION TYPES

Low-Frequency Raman Spectroscopy Enabling Affordable Access to the Terahertz Regime

818 Series Low-Power Detectors

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

Infrared Business Tips & Insight

Verification and Validation of OOV-TET1 Multispectral Camera Observations within the FireBIRD Project

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

James Webb Space Telescope (JWST) Optical Telescope Element (OTE) Pathfinder Status and Plans

WHAT IS LASER ULTRASONIC TESTING?

Annexure-I. 1. Goniophotometer and Goniospectroradiometric measurement System

Defense Technical Information Center Compilation Part Notice

Fundamentals of Far-infrared

Gas Temperature Measurements with High Temporal Resolution

Black Body Calibration Source User Manual

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH

ELLA ID. High CRI, High lm/w OptoDrive LED-module

-smartgas- A new low cost infrared gas sensor for domestic and automotive applications

Establishing a Center of Excellence for. Security Science and Engineering

PG 990 Atomic Absorption

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Advantages / Characteristics

Instruction Manual. gray Housed Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

THE PLACE TO BE FOR AUVERGNE RHÔNE-ALPES COMMITTED FRENCH TECH MEMBER

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

LUXEON S. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON S Photobiological Safety Report

Curing with Electric Infrared

Imaging detection of CO 2 using a bispectral type-ii superlattice infrared camera

Methane to Markets Oil and Natural Gas Technology Transfer Workshop

UV LED Measurement Status Update

Quality Manual of Optical Power Measurements

The FireBird mission - a scientific mission for Earth observation and hot spot detection

USER MANUAL MODEL UV MINDER 3D V2.0. Part Number: Revision Level: A

Corporate Overview. April

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

The FEL Facility Optical Diagnostics and FEL Characterization

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

CS744 Series: Carbon/Sulfur by Combustion

Smoke Detection in Low Gravity Results from the Smoke Aerosol Measurement Experiments (SAME) Conducted on the International Space Station

Presentation Title October 18, Physical Sciences Inc. 20 New England Business Center Andover, MA Outline

Office of Nonproliferation and Verification Research and Development University and Industry Technical Interchange (UITI2011) Review Meeting

The Art and Science of Being Cool

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

Advanced Monitoring and Characterisation of Combustion Flames

Model 5306 FAST. FOCUSED. CONTROLLED. Infrared Heaters For Controlled Concentrated Heating. Infrared Heat. Instantaneous Results.

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

International comparison of validation methods for dust concentration measurement

Surface Mount Ambient Light Sensor PTAS-P1F1708CH6. Features. Descriptions. Applications. Device Selection Guide

Communications. Sensing. Instrumentation. Delivering tomorrow s optical and photonic solutions today. BREAKTHROUGH PHOTONIC PRODUCTS

Transcription:

Source Test and Characterization Program Presented at the 24th Meeting on Characterization and Radiometric Calibration for Remote Sensing (CALCON Technical Meeting) 2015 The Aerospace Corporation Ray Russell, David Ardila, Richard Rudy, Daryl Kim, Kirk Crawford, and Edward Laag The Aerospace Corporation Contact: : ray.w.russell@aero.org 310-336-5528 Engineering and Technology Group/ Space Science Applications Laboratory/ Remote Sensing Department Aug 25, 2015

Motivation Stricter requirements for absolute and relative calibration drive the use of internal sources for EO sensors NASA s CLARREO program specifies <<1% from visible to LWIR The Spatial Infrared Imaging Telescope III (SPIRIT III) on MSX was one of the early examples of internal sources being used to trend sensor responsivity and thus calibration, resulting in ~6% absolute from stars and ~1% trending accuracy in the 4-28 micron spectral range Other programs have now joined in this robust calibration and sensor performance assessment and trending philosophy Provides insight into focal plane changes vs. optics changes Use ground surface (vicarious) calibration regions & stars for point targets to assess end-to-end response variations Can provide assessment of contamination, especially if multiple spectral filters are used Sources can be used for a variety of wavelengths and illumination levels Internal sources can improve knowledge and understanding of onorbit performance of sensitive, critical EO sensors 2

Statement of the Problem Basic requirements for such internal sources include: Most significant requirement is constancy or repeatability, typically better than 1%/year, and long lifetime (~10-15 years for current programs) Desirable to have flood illumination of the focal planes, preferably relatively uniform, but high uniformity is not required (better than a factor of 2 across the focal plane is usually good enough, ~25% is fine) Enables characterization of ALL pixels or detectors in the sensor A range of sources is needed to meet various sensor requirements Need to span dynamic range of the sensor 3 Need to span range of wavelengths typically about 0.4 13 microns Need continuum and narrowband sources Sources may be needed that operate at cold temperatures (down to 77K or even 10K) Not necessary to pass through the whole optical system In fact, direct illumination of the focal planes enables separation of effects, with external point and flood sources to characterize effects of optics Programs tend to only want to use known components that are already space-qualified, so the higher the TRL level, the better

Test and Characterization Plan (1/2): Procure a variety of sources (accomplished): Visible filament sources (e.g., Tungsten) Visible, Near IR and IR LEDs Narrowband and wideband Nichrome ribbon sources used in one space program already, but not fully characterized for spectral performance or performance at various temperatures Perform repeatability tests at ambient temperature Explore circuits/requirements for the driving power supplies, commandable controllers, detector stability and temperature control requirements Perform lifetime tests at ambient temperature and pressure to start plan to begin with ~50,000 cycles under automated computer control Automation will be key to collecting adequate data from many sensors spanning visible to IR 4

Test and Characterization Plan (2/2): Perform repeatability tests over a range of lower temperatures typical of orbiting sensors Using 1 m 3 TVAC chamber with internal LN2 piping for vacuum cold testing down to 77K. May perform lifetime tests at cold temperatures (TBD) Characterize spectral energy distributions At ambient and cold temperatures Narrowband and broadband Look for aging effects in those spectral energy distributions May add effects of vibe testing and thermal cycling on parts (TBD) Propose characterizing sources and then to fly some of them on Aerocube sats to raise TRL in a relevant environment 5

Specific sources (already procured) to be tested include: Blue (0.39 to 0.46 um) LEDs Custom LEDs white light by combining phosphor LEDs with blue LEDs Carley Incandescent bulbs (replace Welch-Allyn halogen bulbs found bad on Hubble Space Telescope cameras) Energetique characterization already begun not small internal sources! OD 800 W LEDs 810 nm Chicago Miniature Lamp (CML - model CM 7220) grain of wheat bulbs, tungsten filaments, ~1800K, ~18V at ~25 ma (SPIRIT III - MSX legacy Duane Miles thesis work in IR), expanded to visible to IR IR LEDs in 7 10 um range Ion Optics Nichrome strips Wide variety to start may redirect testing or add sources during the program, based on interactions with various programs 6

Examples of data taken to date Used Aerospace Visible Near-IR Imaging Spectrograph VNIRIS -.4 2.5 microns to characterize repeatability and spectral energy distributions at ambient conditions Welch-Allyn bulbs Energetique bulbs 7

Welch-Allyn Bulbs used on HST initial cameras later rejected for second round of cameras due to nonrepeatability Setting Voltage (V) Current (A) Power (W) 1 4 0.87 3.47 2 5 0.97 4.85 3 6 1.06 6.38 4 7 1.14 8.14 5 8 1.22 9.77 Beyond setting 4, spectra start to deform. Bulb failed at input power 14 W, aging effects have been noted in testing by other groups 8

Spectra are only approximately blackbodies, and vary with drive current, as expected Emitted flux is linear with power for input power<6 W and nonlinear beyond that. Suggested operational levels would only be below 6 W. 9

Energetique sources EQ-99 Measured spectra for EQ-99Cal compared to company-provided data and data on a Tungsten Lamp 10

Expanded wavelength coverage into Near IR for this source Spectrum of the EQ-99CAL source from 0.4 to 2.1 microns. The dotted line corresponds to a blackbody at 1000 C. Note the precipitous drop beyond 2.1 microns, limiting usefulness in Near IR, and Xe I features 0.8-1.0 um 11

Summary Goal of the program is to provide characterization of a wide range of potential internal sources at ambient pressure and vacuum conditions Repeatability Lifetime Temperature effects Spectral effects visible to thermal IR Raise TRL by flying on Aerocubes Customer-driven program already influencing several programs 12

References Blackborow, Paul, and Energetiq Technology Inc. Ceo. Statement of Energetiq Technology, Inc. For the Committee on Small Business Of The U.S. House of Representatives On Large and Small Businesses: How Partnerships Can Promote Job Growth 28 Mar. 2012; Web. 25 Nov. 2014. "LDLS EQ-99CAL." ENERGETIQ. ENERGETIQ, n.d. Web. 25 Nov. 2014. <http://www.energetiq.com/calibrated-laser-driven-light-source-ldls-99cal-highbrightness-broadband.php>. "Energetiq - Application Note - PEEM." Energetiq - Application Note - PEEM. Energetiq, n.d. Web. 25 Nov. 2014. <http://www.energetiq.com/techlibrary/application_notes/faqs/faqs.html> "NIST Atomic Spectra Database." NIST Physical Measurement Laboratory. Web. 16 Dec. 2014. <http://www.nist.gov/pml/data/asd.cfm>. Rudy, R. J, and Gutierrez, D. J., Focus and Tip-Tilt Alignment Procedure for the Enhanced Aerospace Near-Infrared Imaging Spectrograph. (TR- 2004(8570)-8, The Aerospace Corporation, 2004). Laag, E. et al., A Custom LED Calibration Source for Visible Sensors. (ATR- 2012(8940)-1, The Aerospace Corporation, 2012). 13