PD6662:2010. A guide from Honeywell Security Group

Similar documents
Changes to UK alarm standards. PD6662:2010 April Honeywell Security

ALL YOU NEED TO KNOW ABOUT THE NEW STANDARDS IN ONE HANDY POCKET GUIDE. Updated for 2016 to include IA1501. Brought to you by: In association with:

Changes for EN50131 BS8243 PD6662

Galaxy Flex. What's new? Flexible control panel range for small to medium sized security installations. NEW GX Remote Control compatible

Technical Bulletin Bulletin Number: 2012_02 Released: 1 st May 2012

See the table on the following Page for full descriptions of each Pin Type.

Summary of changes between PD 6662:2010 and PD 6662:2017 a guide

Galaxy Flex. What's new? Flexible control panel range for small to medium sized security installations

Total Connect Box. User manual

A guide to the changes between BS 8418:2010 and BS 8418:2015

Wireless security products

TECHNICAL BULLETIN No: 0040

Galaxy Flex V3. User Guide. Honeywell Security. This user manual is located at

NEW GENERATION WIRELESS ALARM SYSTEMS

New generation wireless alarm systems

Professional Security Made Simple. The new CS Panel range

Wireless Keypads LKP(E)S8M Series

The complete wirefree security alarm solution

PowerMaster Security Solutions

CALL FOR A FREE SURVEY

Delta Monitoring Services Ltd. Looking After Your Point Of View

Wireless Keypad GKP-S8M

High-End Wireless Security

Easy Series Intrusion Control Panel. Selection Guide

A Smart & Integrated Security solution

Warning: Mains voltages are present inside control unit. No user serviceable parts inside.

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Catalogue. Security. systems

User Guide. Contents. About this guide. i-on Style Security System

3 User s settings. 3.3 Internal clock setting

EVO192 v3.0 Fire and Burglary What s New

TECHNICAL BULLETIN No. 0018

IRIS Touch Firmware Enhancements and Additions from Version to Version

A guide to the changes of Amendment 1 of BS

INTRUDER ALARM FOR BUSINESS SECURITY

Howler Go-Link Evacuation Alarm

GRADESHIFT UDL INSTRUCTION MANUAL 2.5 APPENDIX

A basic guide to BS 8418:2015 CCTV Systems for Installers

Made possible by an innovative licensing scheme, which allows individual hardware configuration, up to the maximum configuration:

Input Type: 42: Medical: This is a 24 Hr type input it will activate the external sounder and report a CID event 100.

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

Intruder alarm system Operating Instructions

JA-63 Profi User manual

VISTA 48DLCT HONEYWELL SECURITY

Accenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number:

Concord. Protection for everything you ve worked so hard to build. Concord security systems to safeguard your family and home.

Quick Programmer s Manual

SI120 Guarto Easy I. Alarm system. Fire & Security Products

Contents. Glossary

RVRC Training Manual Fast Trace Installer Menu

Intruder Alarm Advice for Domestic Properties

i on Compact Security System

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Important Notice This guide is delivered subject to the following conditions and restrictions:

PowerMaster. Expanding the Boundaries of Security. PowerG. Technology. with

IDS816 User Manual H Issued January 2009

Summit 3208GLD USER MANUAL. Electronics Line

Installation Manual Premier 412/816/832. Issue 10

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

LPS 1014 Scheme Requirements for certificated fire detection and alarm system firms. Presented by - Reg Grigg LPCB

Security Alarm Systems

All tested. Easy Series Intrusion Control Panel Making security easy featuring wlsn* * wireless Local SecurityNetwork

Watchguard WGAP864 User Manual

600 Range Dialer Installation Manual. Version 1.0

BURGLAR ALARM PANEL BS-468

a guide to the interpretation of

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

AMAX Intrusion Alarm Systems System overview

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

HARDWIRED CONTROL PANELS

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A

Your specialist partner for total electrical compliance. Electrical Testing

16 and 16 plus User s Guide

ANEP S-BOX EMERGENCY TELEPHONE FOR ELEVATORS.

"Pegaso" wireless alarm system

P Zone Expandable Hybrid Security System

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

Complete control. Being far, feeling close

Home Automation. Product info. Marketed By: BlueSilica Technologies For further details write to

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

User Manual. Alarm system: PhoneWatch TC

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II

Model: Ei450. Instruction Manual

How to Build Visonic PowerMaster Wireless Alarm Systems

Security Systems and Alarms Inspection Board. Code of Practice For Vacant / Void Property Alarm Systems

LS800S Intruder Alarm System. Engineering Manual

NetworX Series NX-1500E LED Keypad

WEBWA al Y arm 2 sig 4 nall2 in 4

ATS2000/3000/4000/4500 Control Panel. Programming guide

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications.

INSTRUCTION MANUAL PC255O

For business, corporate and public sector security. Protected premises, protected network

/10 Rev A

Construction Products Regulation (CPR) Update. Graham Simons Technical Manager, FIA

ACP10 & ACP50 Security Systems

Security Systems and Alarms Inspection Board. Code of Practice For Scaffold Alarm Systems

Electronic Fire and Security Systems: Intruder and Hold-Up Alarm Systems Installation (SCQF level 6)

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

NETWORX TM. User manual NX-4

Transcription:

PD6662:2010 A guide from Honeywell Security Group

Contents 1. Introduction 2. What is PD6662:2010? 3. When do the changes apply? 4. Key changes 4.1 - EN50131-x 4.2 - PD6662:2010 4.3 - BS8243 5. Honeywell product compliance status 6. Hold-up sequential confirmation - The facts 2

1. Introduction With the dual-running period of the old and new PD6662 schemes now at an end, it is important to ensure that your company is aware of the changes and the impact that the new scheme will have on your business. This booklet is intended to give an overview of these changes and give guidance on how Honeywell security products can be installed to satisfy these new standards. 2. What is PD6662:2010? PD6662:2010 is an update to the PD6662:2004 standard. This current update will: Call up the latest versions of the EN50131-x series standards. Key changes include: - EN50131-1:2006 General Requirements - EN50131-3:2009 Control and Indicating Equipment - EN50131-6:2006 Power Supplies - EN50131-7:2008 Installer Guidelines - EN50131-8:2009 Fog Device Systems Update the standards for confirmed alarms - BS8243: replaces DD243 - Incorporated EN standards where applicable - Address areas where DD243 did not fully meet the industry needs Tidy up inconsistencies in PD6662:2004 - Terminology, etc 3. When do these changes apply? From 1st June 2012 onwards all new installs and installs which require URN renewal must be fitted to PD6662:2010 if police response is required. 3

4. Key Changes 4.1 EN50131-x There are a number of changes required to ensure adherence to the latest EN50131-x standards. These are: Product labels must visibly state the applicable version* of the required standard eg. EN50131-3:2009. All technical literature pertaining to the security system must contain specific minimum information regarding power, environmental class and product type. It is the installer s responsibility to ensure systems are marked to the correct standard. All Grade 3 devices must have an off-wall tamper (removal from mounting detection) switch, including keypads and expanders. Every battery must have individual monitoring including two batteries in parallel All Grade 3 PIR/DUAL TEC sensors must have the capability to have the LED enabled remotely. 4.2 PD6662:2010 These requirements are for UK installations only and are over and above those required by EN50131-x. All systems must define the minimum grade for police response It is now permissible to use a plug for all power supplies if removal protection is in place BS8243:2010 replaces DD243 for alarm confirmation changes (please see below) An explanation of the selected combinations should be provided to the user/client to ensure the most appropriate confirmed technology is used. Unless agreed with the client in writing, sequential confirmation should be used only in conjunction with telephone confirmation. 4.3 BS8243:2010 The entry timer expiry and one detector off the entry route is now sufficient to activate a confirmed alarm. Previously, DD243 required two detectors off the entry route and did not recognise entry time expiry as contributing to a confirmed alarm. This will make installation easier in one-room premises (e.g. a small shop, open plan premises) as it does not require setting/unsetting outside of the premises. *If insufficient space is available for codes the component shall include a means of identification which allows cross reference to documentation providing the required info. 4

Driven by The Association of Chief Police Officers (ACPO) due to the increase in false alarms, a new requirement has been introduced which requires Hold-up alarms to be confirmed for police response. Confirmation can be done in a number of ways: - Video confirmation: alarm supplemented with video images - Audio confirmation: alarm supplemented by audio data - Sequential confirmation: two or more alarm activations within a single period - Alarm Receiving Centre (ARC) Call Back to site Any of the above methods can be used for full compliance to PD6662:2010. 5. Honeywell Product Compliance Status Product PD6662: 2010 Status Galaxy Flex Galaxy Dimension G2 MK8 Keypad/prox TouchCenter/prox MK7 Keypads/prox RIOs Power RIOs Wired Grade 2 motion sensors Wired Grade 3 motion sensors Wired seismic sensors Wired shock sensors Wireless motion sensors Wireless magnetic contacts Wired and wireless glassbreak detectors Not Applicable Wired and wireless smoke sensors Not Applicable Wired sirens check catalogue reference September 2012 Wireless sirens 5

Honeywell Product Changes Peripherals (Keypads, RIOs etc...): labelling changes only product is functionally identical and fully interchangeable G2 control panels: Firmware update (V1.52) and above plus labelling changes, which are identified by software revision label on carton. Galaxy Flex control panels: no changes - compliant since September 2011 Galaxy Dimension control panels: A hardware configuration change an off-wall tamper (removal from mounting detection) is required for every panel. A part number change has been introduced which includes this tamper switch. Also, a new dual-battery monitor module (A079) is available as an option, as well as a firmware update (V6.78) and above plus labelling changes to show the new part numbers and product labels must visibly state the applicable version of the required standard. Old Part Number New Part Number Product Description C048-C-E1 C048-D-E1 Galaxy Dimension GD-48 control panel with PSTN Dialler C096-C-E1 C096-D-E1 Galaxy Dimension GD-96 control panel with PSTN Dialler C264-C-E1 C264-D-E1 Galaxy Dimension GD-264 control panel with PSTN Dialler C520-C-E1 C520-D-E1 Galaxy Dimension GD-520 control panel with PSTN Dialler 6. Hold Up Sequential Confirmation The Facts The concept of sequentially confirmed Hold-up alarms is new to the intruder industry. Below is a summary of the required operation detailed in BS8243: 2010: A Hold-up alarm is considered to be a confirmed alarm if any of the below sequence of events occurs within 8-20 hrs: - Two separate PA zones, each with standard twin-push activation - One PA zone with a multi-action switch activating two separate PA alarms - One PA + one PA zone tamper Signalling: - New SIA/Contact ID events have been defined for confirmed Hold-up (SIA HV event, Contact ID code 129 ). If using these formats your Alarm Receiving Centre (ARC) must be equipped to receive these events. - ARC receives current Hold-up/PA event followed by new confirmed Hold-up/PA event 6

- Fast Format/RedCare/DualComm etc there is an extension of use of the current Confirm channel - Panel activates via PA output, on first PA event followed by confirmed alarm output, channel on sequential activation. Portable Hold-up devices - Wireless PA - Must meet the requirements of BS8243: 2010 - Dual button, dedicated device, or two separate devices activated - Allowed in a Grade 3 system without reducing the overall grade of the system, providing that the wireless PA is on its own sub-section BS8243:2010 Galaxy Compliance to BS8243: 2010 Hold-up alarm verification Honeywell Galaxy systems are compatible with call-back confirmation Separate video and audio systems can be used to offer video and audio confirmation A lower-cost Image Sequence Video Confirmation system is being developed by Honeywell and is expected to be available in 2013 Sequential confirmation has been added to G2 and Galaxy Dimension systems 7

For more information visit our dedicated web page: www.honeywell.com/security/uk/pd6662 Or email: securityuk@honeywell.com HSG-PD6662:2010-01-EN(0712)-SB-E July 2012 2012 Honeywell International Inc.