Two-Position Electric Duplex Room Thermostats

Similar documents
PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Schneider Electric Erie T155 Series

TC-5231 Series, TC-5232, & TC-5241 Series

CP CP

59T, 66T Series Electric Water Heater Controls

I N STALL AT ION & O PERATIO N MANUAL TA 1/ TA 2 CONTROLLER. Redefine your comfort zone.

59T, 66T Series Electric Water Heater Controls

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

TEMPERATURE & PRESSURE CONTROLS

Evaporative Cooling Controls... 1F51 / 8A18Z / 21D Thermostat Guards, Plastic... F Thermostat Guards, Metal... F29...

TK-1801, TK-1811 TK-1801, TKR-1811

Powers Controls ET 134 Low Temperature Detection Thermostat

Powers TM Controls ET 134 Line Voltage Room Thermostats

Pump-Down Controller MODEL 4052

T834C Heating-Cooling Thermostat

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

Pump-Up Controller MODEL 4062

INSTALLATION AND OPERATION MANUAL ANALOG ELECTRONIC CONTROLS VAV TERMINAL UNITS

features Overview Powerstar Room Thermostats Description Applications Selection Guide Thermostats & Hygrostats A-3

Heat Link. Technical Guide

T4398A,B Precision Electric Heating Thermostat

THERMOSTAT i-basic 3 USER MANUAL Rev.100

W43A Humidistat. Features and Benefits

T170 Thermostat. Installation and Maintenance Manual. 24 VAC/ VAC 3-Speed Fan Control (Continuous or Cycling) or Staged Fan Control

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

water source / fan coils

UNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Gate Operator. Modfications

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

ULTRA-SAFE Explosion-proof Duct Heaters

Fluid Cooler Fan and Pump control panel

Variable Area Flowmeters Ratosight TM Flow Rate Indicators with Optional Ratolarm - 10A2235

TB-200 CD-TB PRODUCT OVERVIEW. Product. Description. Specifications SKU: TB-200. Wiring. Battery Powered Thermostat

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

B24 SERVICE UNIT INFORMATION B24 SERIES ADD-ON BLOWER ECB24 SERIES ELECTRIC HEAT

Powers Controls Low Temperature Detection Thermostat

THERMOSTAT series TM10

THERMOSTATS & CONTROLS

TC-9102 Applications

TEC Controller Unit Conditioner - Two-Pipe Fan Coil Cooling or Heating, Application Application Note Building Technologies

LOW VOLTAGE CONTROL CIRCUIT WIRING

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Cedarbrook Sauna + Steam Family owned and operated since 1971

Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0

Table of Contents. Protective Relays

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Installation Manual for Hot Yoga Studio Electric Radiant Heating

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:

B SERIES ELECTRIC FURNACE

INTRODUCTION / TABLE OF CONTENTS

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

TM Series. Induced Draft, Counter Flow Optional Accessories

JDB4000AWB JDB4000AWQ JDB4000AWS JDB4000AWW MDB5600AWB MDB5600AWQ MDB5600AWS MDB5600AWW

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX (951) Growmate Growmate Plus

ULTRA-SAFE Explosion-proof Duct Heaters

PART NO. COMBUSTION AIR CAP

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Technical Information- Dishwasher MDB8750AWB MDB8750AWQ MDB8750AWS MDB8750AWW MDB9750AWB MDB9750AWQ MDB9750AWS MDB9750AWW

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-315(C)

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

CAUTION. No-Load Performance, Controls in Normal Position

Commercial and Light Industrial Fire Alarm Control Panel

CAUTION. To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing. MDBTT50AW*

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing.

EC Series Wall Unit Humidifier

FLT93 Installation, Operation and Troubleshooting Guide

POWERS Pneumatic Thermostat Covers

SmartZone TM System Manual

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

ESSEX ENGINEERING CORPORATION

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Transcription:

TC-XX Series, TC-XX Series, TF- Series Two-Position Electric Duplex Room Thermostats These thermostats provide on-off control of heating/cooling systems. TC-XX Series, TC-XX Series, TF- Series Features: Separate units for C and F. All units except TC-4. - Parallel heat and/or cooling anticipation capability. - Dial stop pins to limit range. - Lock cover screw/sets available. - Agency approval. - Switch bases AT-2 and AT-3 available for custom applications. TC-8X and TC-9X. - Fan switch option standard. 0 5 5 59 0 5 59 20 C 68 F 20 25 25 77 68 77 88 F 30 C 30 88 TC-4 OFF LO HI HI MED OFF LO TC-86 TC-87 TC-88 TC-95 TC-99 * TC-9* TC-0X* TF- *Only TC-9 and TC -0X with factory-supplied metal cover are CSA approved. TC-9, TC-0X, TF- with Digital Thermometer Kit Installed Model Chart Application Setpoint Dial Range Differential Switch Refer to Ratings Table Connections Cover Dimensions In. (mm) H x W x D TC-4 TC-86 TC-87 TC-88 TC-87-6 TC-88-6 TC-95 TC-99 On/off control of unit heaters or motors. Sequenced onoff control of line voltage fan coil or zone valves on heating and cooling systems. On-off control of line voltage fan coil or zone valves on heating and cooling systems. to 86 F (0 to 30 C) Dual marked 55 to 85 F 3 to 29 C 55 to 85 F (3 to 29 C) Heat, 2 F (. C) Cool, 3 F (.7 C) Heat, 2 F Neutral, 2 F Cool, 2 F Heat,. C Neutral,. C Cool,. C.5 F (0.8 C) Heat, 2 (. C) Cool, 2 (. C) Neutral, 2 (. C) SPDT zero energy band SPDT zero energy band Color-coded Coded screw terminals and color-coded plastic with metal brushed bronze insert metal with metal brushed bronze insert 4-/2 x 2-3/4 x -/8 (4 x x 29) 4-3/8 x 2-3/4 x -5/8 ( x x 4) 38

TC-XX Series, TC-XX Series, TF- Series Model Chart (Continued) Application Setpoint Dial Range Differential a TC-0 55 to 85 F 2 F TC-0-6 3 to 29 C C TC-0-0 a Low or line 55 to 85 F 2 F TC-02 voltage on-off 45 to 75 F 2 F control of fan TC-02-6 coils, fans, motor 7 to 23 C C TC-02-0 a starters, contactors, twoposition electric 2 F 45 to 75 F TC-02-2 b TC-03 actuators. 75 to 05 F TC-03-6 2 to 39 C C TC-03-0 a 75 to 05 F 2 F TC-9 Low or line 55 to 85 F TC-9-6 TC-9-0 voltage on-off 3 to 29 C control of Heat, 2 (. C) heat/cool Cool, 2 (. C) systems such as 55 to 85 F Neutral, 2 (. C) TC-9-2 b 3 or 4 pipe unitary. Switch Refer to Ratings Table TF- 55 to 85 F 4 F SPDT Floating control floating off of one MF-233 TF--6 0. FLA @ series actuator. 3 to 29 C 2 C 24 Vac Connections Color-coded Cover plastic as standard Dimensions In. (mm) H x W x D 4-3/8 x 2-7/8 x -5/8 ( x 73 x 4) a b Heat anticipation model. Night depression model. with Standard Insert Insert Figure Standard Covers. F C TC-XXX-399 TC-XXX-398-400 -40-403 -43 5/64" Allen screw used to secure cover. -404-44 Figure 2 Options (for quantities of 24 or more each number) Add dash number (-XXX) suffix to base [part number of desired option]. For metal covers, specify TC2-XX. No cover option for TC-XX. 39

TC-XX Series, TC-XX Series, TF- Series Specifications Thermostats mounted on concrete walls or surfaces that change temperature slowly, have reduced response to changes in air temperature. Response is further delayed by guards that restrict air flow Anticipators to the thermostat. Anticipators are required (parallel for cooling, series or parallel for heating) for any of these conditions and in spaces intended for continuous occupancy; i.e., hotel guest rooms and offices. TC-8X Series Cooling is fixed. TF- Series Heating and cooling; factory-installed resistors are sized for 0.6 FLA @ 24 Vac maximum. Fan switch TC-8X Series Marking: Low-Off a -Med-High. Marking: Off-Lo-Hi TC-9X Series a. Construction: Integral two-pole three-position. Sensing element Bimetal. Mounting Flush or 2 x 4 wall box. Locations NEMA Type. a Off position de-energizes thermostat and fan. Ratings. Volts (AC) Fan Switch Full Load Locked Volts (AC) Full Load Thermostat Contacts Locked Rotor Pilot Duty (VA) Non-Inductive TC-4 TC-4-7 20/240 9.8/8 58.8/48 25/25 TC-86 24 24 40 TC-87 TC-87-6 TC-87-7 TC-88 TC-88-6 TC-88-7 TC-95 TC-95-7 TC-99 TC-99-7 TC-0 TC-0-6 TC-0-0 TC-0-0 TC-02 TC-02-6 TC-02-0 TC-02-2 TC-02-7 TC-03 TC-03-6 TC-03-0 TC-03-7 6 36 20 20 4.4 26 240 3 8 240 3 8 20/240 6/3 36/8 20/240 24/20/240 3/.5 8/9 25.0/0.5 6/3 40 Heat, 4.4/4.4/2.2 Cool, 3.0/3.0/.5 Heat 26.4/26.4/3.2 Cool, 8/8/9 40/20/20 320

TC-XX Series, TC-XX Series, TF- Series Ratings (Continued). TC-9 TC-9-6 TC-9-0 TC-9-2 TC-9-7 TF- TF--6 TF--7 Volts (AC) Fan Switch Full Load Locked Volts (AC) 24/20/240 Full Load Heat, 4.4/4.4/2.2 Cool, 3.0/3.0/.5 Thermostat Contacts Locked Rotor Heat 26.4/26.4/3.2 Cool, 8/8/9 Pilot Duty (VA) 40/20/20 24 0.6 at 24 Vac Non-Inductive Accessories AT-6 Series AT-0 AT-04 AT-4 AT-5 AT-546 AT-2 AT-3 AT-03 AT-04 AT-05 AT-55 AT-65 TOOL- TOOL-3 Description Brushed bronze cover plates. Lock cover kit. Dial stop pins (pins included with each unit). Plaster hole cover kit (small). Surface mounting base. Auxiliary mounting plate. Selector switch sub-base DP4T. Selector switch sub-base one DP4T, one DPDT. Wire guard. Cast aluminum guard. Calibration wrench. Contact burnishing tool. Typical Applications (Orange) Common Black makes ON temp. drop. Figure 3 TC-4 Switch Action and Lead Identification. (Orange) Common L Heat makes ON temp. drop. Black/ Night Depression Black/ Figure 4 TC-0X Series Switch Action and Lead Identification. 32

TC-XX Series, TC-XX Series, TF- Series Cooling Anticipator C Hi Med Off Low B 2 R Cooling () Heating () High (Yellow) Medium (Black) Low (Blue) L (Orange) Ground (Green) Thermostat. makes ON temp. drop. 2 Fan switch shown in off position. To Fan Motor Figure 5 TC-8X Series Switch Action and Terminal Identification. (Orange) L Heat makes ON temp. drop. Black/ Night Depression Black/ Figure 6 TC-9 Switch Action and Lead Identification. (Purple) Jumper B R 2 Thermostat. makes ON temp. drop. 2 Fan switch shown in low position. (Black) L Hi Low To Fan Motor Off Figure 7 TC-9X Series Switch Action and Terminal/Lead Identification. Orange TF- Heat Anticipator (Heat) CCW 3 MF-233 Actuator 24 Vac Max Draw 0.6 Amp Black/ Black/ Cool Anticipator (Cool) CW 2 COM Figure 8 TF- Switch Action and Typical Wiring. 322