TC-XX Series, TC-XX Series, TF- Series Two-Position Electric Duplex Room Thermostats These thermostats provide on-off control of heating/cooling systems. TC-XX Series, TC-XX Series, TF- Series Features: Separate units for C and F. All units except TC-4. - Parallel heat and/or cooling anticipation capability. - Dial stop pins to limit range. - Lock cover screw/sets available. - Agency approval. - Switch bases AT-2 and AT-3 available for custom applications. TC-8X and TC-9X. - Fan switch option standard. 0 5 5 59 0 5 59 20 C 68 F 20 25 25 77 68 77 88 F 30 C 30 88 TC-4 OFF LO HI HI MED OFF LO TC-86 TC-87 TC-88 TC-95 TC-99 * TC-9* TC-0X* TF- *Only TC-9 and TC -0X with factory-supplied metal cover are CSA approved. TC-9, TC-0X, TF- with Digital Thermometer Kit Installed Model Chart Application Setpoint Dial Range Differential Switch Refer to Ratings Table Connections Cover Dimensions In. (mm) H x W x D TC-4 TC-86 TC-87 TC-88 TC-87-6 TC-88-6 TC-95 TC-99 On/off control of unit heaters or motors. Sequenced onoff control of line voltage fan coil or zone valves on heating and cooling systems. On-off control of line voltage fan coil or zone valves on heating and cooling systems. to 86 F (0 to 30 C) Dual marked 55 to 85 F 3 to 29 C 55 to 85 F (3 to 29 C) Heat, 2 F (. C) Cool, 3 F (.7 C) Heat, 2 F Neutral, 2 F Cool, 2 F Heat,. C Neutral,. C Cool,. C.5 F (0.8 C) Heat, 2 (. C) Cool, 2 (. C) Neutral, 2 (. C) SPDT zero energy band SPDT zero energy band Color-coded Coded screw terminals and color-coded plastic with metal brushed bronze insert metal with metal brushed bronze insert 4-/2 x 2-3/4 x -/8 (4 x x 29) 4-3/8 x 2-3/4 x -5/8 ( x x 4) 38
TC-XX Series, TC-XX Series, TF- Series Model Chart (Continued) Application Setpoint Dial Range Differential a TC-0 55 to 85 F 2 F TC-0-6 3 to 29 C C TC-0-0 a Low or line 55 to 85 F 2 F TC-02 voltage on-off 45 to 75 F 2 F control of fan TC-02-6 coils, fans, motor 7 to 23 C C TC-02-0 a starters, contactors, twoposition electric 2 F 45 to 75 F TC-02-2 b TC-03 actuators. 75 to 05 F TC-03-6 2 to 39 C C TC-03-0 a 75 to 05 F 2 F TC-9 Low or line 55 to 85 F TC-9-6 TC-9-0 voltage on-off 3 to 29 C control of Heat, 2 (. C) heat/cool Cool, 2 (. C) systems such as 55 to 85 F Neutral, 2 (. C) TC-9-2 b 3 or 4 pipe unitary. Switch Refer to Ratings Table TF- 55 to 85 F 4 F SPDT Floating control floating off of one MF-233 TF--6 0. FLA @ series actuator. 3 to 29 C 2 C 24 Vac Connections Color-coded Cover plastic as standard Dimensions In. (mm) H x W x D 4-3/8 x 2-7/8 x -5/8 ( x 73 x 4) a b Heat anticipation model. Night depression model. with Standard Insert Insert Figure Standard Covers. F C TC-XXX-399 TC-XXX-398-400 -40-403 -43 5/64" Allen screw used to secure cover. -404-44 Figure 2 Options (for quantities of 24 or more each number) Add dash number (-XXX) suffix to base [part number of desired option]. For metal covers, specify TC2-XX. No cover option for TC-XX. 39
TC-XX Series, TC-XX Series, TF- Series Specifications Thermostats mounted on concrete walls or surfaces that change temperature slowly, have reduced response to changes in air temperature. Response is further delayed by guards that restrict air flow Anticipators to the thermostat. Anticipators are required (parallel for cooling, series or parallel for heating) for any of these conditions and in spaces intended for continuous occupancy; i.e., hotel guest rooms and offices. TC-8X Series Cooling is fixed. TF- Series Heating and cooling; factory-installed resistors are sized for 0.6 FLA @ 24 Vac maximum. Fan switch TC-8X Series Marking: Low-Off a -Med-High. Marking: Off-Lo-Hi TC-9X Series a. Construction: Integral two-pole three-position. Sensing element Bimetal. Mounting Flush or 2 x 4 wall box. Locations NEMA Type. a Off position de-energizes thermostat and fan. Ratings. Volts (AC) Fan Switch Full Load Locked Volts (AC) Full Load Thermostat Contacts Locked Rotor Pilot Duty (VA) Non-Inductive TC-4 TC-4-7 20/240 9.8/8 58.8/48 25/25 TC-86 24 24 40 TC-87 TC-87-6 TC-87-7 TC-88 TC-88-6 TC-88-7 TC-95 TC-95-7 TC-99 TC-99-7 TC-0 TC-0-6 TC-0-0 TC-0-0 TC-02 TC-02-6 TC-02-0 TC-02-2 TC-02-7 TC-03 TC-03-6 TC-03-0 TC-03-7 6 36 20 20 4.4 26 240 3 8 240 3 8 20/240 6/3 36/8 20/240 24/20/240 3/.5 8/9 25.0/0.5 6/3 40 Heat, 4.4/4.4/2.2 Cool, 3.0/3.0/.5 Heat 26.4/26.4/3.2 Cool, 8/8/9 40/20/20 320
TC-XX Series, TC-XX Series, TF- Series Ratings (Continued). TC-9 TC-9-6 TC-9-0 TC-9-2 TC-9-7 TF- TF--6 TF--7 Volts (AC) Fan Switch Full Load Locked Volts (AC) 24/20/240 Full Load Heat, 4.4/4.4/2.2 Cool, 3.0/3.0/.5 Thermostat Contacts Locked Rotor Heat 26.4/26.4/3.2 Cool, 8/8/9 Pilot Duty (VA) 40/20/20 24 0.6 at 24 Vac Non-Inductive Accessories AT-6 Series AT-0 AT-04 AT-4 AT-5 AT-546 AT-2 AT-3 AT-03 AT-04 AT-05 AT-55 AT-65 TOOL- TOOL-3 Description Brushed bronze cover plates. Lock cover kit. Dial stop pins (pins included with each unit). Plaster hole cover kit (small). Surface mounting base. Auxiliary mounting plate. Selector switch sub-base DP4T. Selector switch sub-base one DP4T, one DPDT. Wire guard. Cast aluminum guard. Calibration wrench. Contact burnishing tool. Typical Applications (Orange) Common Black makes ON temp. drop. Figure 3 TC-4 Switch Action and Lead Identification. (Orange) Common L Heat makes ON temp. drop. Black/ Night Depression Black/ Figure 4 TC-0X Series Switch Action and Lead Identification. 32
TC-XX Series, TC-XX Series, TF- Series Cooling Anticipator C Hi Med Off Low B 2 R Cooling () Heating () High (Yellow) Medium (Black) Low (Blue) L (Orange) Ground (Green) Thermostat. makes ON temp. drop. 2 Fan switch shown in off position. To Fan Motor Figure 5 TC-8X Series Switch Action and Terminal Identification. (Orange) L Heat makes ON temp. drop. Black/ Night Depression Black/ Figure 6 TC-9 Switch Action and Lead Identification. (Purple) Jumper B R 2 Thermostat. makes ON temp. drop. 2 Fan switch shown in low position. (Black) L Hi Low To Fan Motor Off Figure 7 TC-9X Series Switch Action and Terminal/Lead Identification. Orange TF- Heat Anticipator (Heat) CCW 3 MF-233 Actuator 24 Vac Max Draw 0.6 Amp Black/ Black/ Cool Anticipator (Cool) CW 2 COM Figure 8 TF- Switch Action and Typical Wiring. 322