KIT NOTICE. These instructions are for replacing the two existing thermostats with a single new solid-state thermostat.

Similar documents
KIT NOTICE. These instructions are for replacing the three existing thermostats with a single new solid-state thermostat.

THERMOSTAT RETROFIT INSTRUCTIONS

AVENGER HT THERMOSTAT RETROFIT INSTRUCTIONS

DRAIN WATER TEMPERING INSTALL

WARNING. Failure to install this kit within the guidelines might adversely affect safety, performance, component life and warranty coverage.

DRAIN WATER TEMPERING INSTALL

WARNING DESCRIPTION PART NUMBER QTY PLUMBING, DYNATEMP DRAIN QUENCH BRACKET, THERMOSTAT DRAIN QUENCH

DRAIN WATER TEMPERING INSTALL

INSTALLATION INSTRUCTIONS

Service Manual 26 Self Trimming Fireplace with 3 Stage Remote

Installation Instructions

Summer Breeze Heater Service Manual

PO Box 827 Hawley, MN (218) Fax (218)

WARNING. Tighten strain relief screws to secure cable. Make sure screw heads are facing up when tightening conduit nut.

5800 Refrigerator Compressor Capacitor/Relay Kit

Hanson LED C e i l i n g F a n

Heat Exchanger Block Replacement Instructions

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Platinum Split 4000 & Platinum Split 4000 Fully Ducted COLD WEATHER START KIT Installation Manual

Owner s Manual FS-10/FreshSpa

Service Manual 26 Self Trimming Export Fireplace with 3 Stage On/Off Remote

No. Of Ignition Trials: No. Of Re-Ignition Attempts. Reset by interrupting power for 5.0 Seconds. Diagnostic Output. Re-Ignition Limit Exceeded

PWC 1800 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model PWC P/N man Copyright 2011 Vertex Water Products

Product Support Bulletin

Water Distiller Service Manual

Smart Water Heater Controller

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

BUNN H5E H5M H5X BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

Service Manual. Model Number VCX1525 VCX1525-WH. UL Part Number

5YK60XXX Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 5YK60XXX

Installation Instructions 30 French Door Built-in Wall Ovens

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Tempest Hot Air Drying System. Installation Instructions. Ryobi X /98 Rev-C

Service Manual. Model Number VCX1525 VCX1525-WH. UL Part Number

Nilfisk Inc Winnetka Avenue North Minneapolis, MN REV.03( ) VF80189

HEAT/ COOL/ DEFROST FORD THUNDERBIRD

EF3003 SF3003 DF3003

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

TECHNICAL INSTRUCTIONS

DELTA 1200/115 INSTALLATION, OPERATION, AND SERVICE MANUAL DELTA SERIES GLASSWASHER DISHMACHINES. Delta 1200/115 Manual S

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

Installation Instructions for Kay Chemical / Power Soak Dual Dispenser Pump (01/02/03)

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

Digital Control Module Replacement Manual

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

Installation Instructions for Med Touch Master Alarms - Wireless

BF5000NT BF5000 EF2604 SF2603 DF2603

ONBOARD BOOSTER INSTALL

D1/D2 Direct Vent Pilot Replacement Model #: D INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.

TK-5001, Pneumatic Room Thermostats General Instructions GENERAL INFORMATION INSTALLATION

Oscillating Ceiling Fan

Electric Dryer Installation Instructions

Installation Instructions

BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS

Ceiling Fan Installation Instructions

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

ELECTRIC DRYER INSTALLATION INSTRUCTIONS

21 TRV Blower Installation Instructions

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

PHASE CONVERSION INSTRUCTIONS

Service. Manual. Trash Compactor. Preferred Service FCU150

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

SERVICE MANUAL MULTI DECK 60 HOT MERCHANDISER MULTI DECK 100 HOT MERCHANDISER MULTI DECK 120 HOT MERCHANDISER CLASSIC DECK HOT MERCHANDISER

I<enmore Elite. instructions dlnstallation. Installation Guide Instrucciones de Instalaci6n. English / Espafiol/Frangais

Service Manual Trash Compactor Models 15XESSEXF A November 2010 Broan-NuTone LLC 926 West State Street Hartford, WI

SERVICE NUMBER: SERV-351

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHER PLASTIC TUB INSTRUCCIONES DE INSTALACIÓN LAVAVAJILLAS EMPOTRADA CON TINA PLÁSTICA

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

INSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D.

Electric Heater Technical Bulletin No. 19

Commercial Electric Energy Saver Water Heater IMMERSION AND SURFACE MOUNTED THERMOSTAT MODELS

Parts and Service Manual

FIREPLACE INSTALLATION

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

HX Field Replacement Kit

3CLMR56XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3CLMR56XXD

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Heater Upgrade Instructions

Click here for a labelled version of above

FCT-CE SERIES ELECTRIC TILTING KETTLE W/HAND CRANK PARTS AND SERVICE MANUAL

Component Replacement Guidelines. For AIRSYS Wall Packaged Units. Models

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

Installation Manual Mopar Engine Compartment Upgrade Kit

WATT R TWIN Energy-Efficient Home Water System

MEIKO Undercounter Dish and Glass Washing Machine. Spare Parts List 208V/230V 1/3-PHASE 60 HZ

Installation Instructions for the PITCO Self-Cleaning Burner System

Service Manual. Model Number: BF362SD BF392SD. UL Part Number

INSTALLATION & OPERATION MANUAL

Installation. Leveling

T874 Multistage Thermostat and Q674 Subbase

Tripod Ceiling Fans. Installation Instructions Models: CT52, D52, FR52, ME52 & OL52 (800) BETTER BY DESIGN MEJOR DISEÑO BETTER BY DESIGN

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

Service Manual. Model Number: DF2024. UL Part Number

Service Manual. Model Number: Compact Fireplace DF203A DF2006. UL Part Number to 800

Transcription:

KIT 06401-004-22-16 5 1 2 NOTICE 3 (3 PLC'S) These instructions are for replacing the two existing thermostats with a single new solid-state thermostat. 4 PREPARATION PARTS INCLUDED 6 1 7 5 8 2 4 (4 PLC'S) 3 (3 PLC'S) Disconnect electrical power at the breaker or disconnect switch and lockout/tagout in accordance with procedures and codes. (4 PLC'S) 8 7 6 9 10 11 12 13 14 Some parts in this kit are only for the HH model. These parts 15 will not be used in these instructions. Remove the strainer and drain stopper and completely drain the wash tank. 9 10 11 12 13 14 15 17 HIGH HOOD KIT 20 19 HIGH HOOD KIT 18 11 21 TOOLS REQUIRED Adjustable Wrench Phillips Screwdriver Small Bucket (~1 gallon) 5/16 Nut Driver Wire Crimper Flathead Screwdriver Step Stool Wire Stripper Needle Nose Pliers 3/8 Wrench 7/16 Wrench 5/8 Wrench ITEM QTY DESCRIPTION PART NUMBER 1 1 Cover, Wash Tank Heater 05700-004-22-15 2 1 Decal, Warning-Disconnect Power 09905-100-75-93 17 3 3 Terminal, Female 05940-200-58-00 19 4 1 18 Thermostat, Elan Electric 21 06685-004-17-27 11 5 2 Screw, 6-32 x 5/8 05305-011-39-85 6 1 Thermostat Mounting Bracket Assembly 05700-004-22-17 7 1 Harness, 4-Pin, 4-Wire 05700-004-22-18 8 4 Terminal, Male 05940-200-74-00 9 2 Fitting, 1/4 Brass Nut/Sleeve 05310-924-02-05 10 1 Grommet, 7/8 05975-200-40-00 11 3 Zip-tie, 4 05975-602-01-16 12 1 Harness, 5-Pin Connector, 4-Wire 05700-004-22-19 13 1 Harness, 7-Conductor, 6-Wire 05700-004-22-29 14 2 Thermistor Probe, 4 06685-004-17-26 15 1 Schematic (Not Shown) 09905-004-22-10 16 1 Instructions, Thermostat Retrofit (Not Shown) 07610-004-22-11 17 1 Harness, 2-Pin Connector, 2-Wire 05700-004-23-19 18 1 Harness, Control Relay to 6-Conductor Cable 1 05700-004-23-30 19 1 Harness, Control Relay to 6-Conductor Cable 2 05700-004-23-31 20 1 Plug, Brass 05700-011-73-73 21 3 Wire Nut, Blue Metal 05945-111-01-00 22 1 Instructions, HH Thermostat Retrofit (Not Shown) 07610-004-22-18 1 of 12 20

PANEL & COVERS 1. Lift up the front dress panel and pull out gently to remove. Set the panel to the side and keep the hardware. It will be re-installed later. Set the rinse heater cover to the side and keep the hardware. It will be re-installed later. 2. Remove both wash and rinse heater covers using a 3/8 wrench. Discard the wash heater cover but keep the hardware. A new cover will be installed later. Rinse Heater Cover Wash Heater Cover CONTROL BOX 3. Remove the top of the control box using a phillips screwdriver. See page 12 for a layout of control box components. 4. Get the gray 6-conductor cable from the kit. Cut the orange and blue wires off at the edge of the gray sheath and discard. Notice that one end has all female terminals (this is the bottom portion) and the other end has one male and three females (this is the top portion). Keep the strain relief near the bottom portion of the cable. 6-conductor cable from the kit is Grommet from the kit is 5. Route the cable from the top of the machine and trail it down to the wash heater area. 6. Pop-out a black blank on the back of the control box and insert a new grommet from the kit. 2 of 12

CONTROL BOX 7. Insert the top portion of the cable (with the male and female terminals) through the grommet inserted in the previous step (leave ~12 in the control box). 8. Run the cable down the back of the machine. Make sure to run the wire under the bar and bracket in the back so it s not hanging loose. 9. Route the cable between the wash tank and rinse booster, underneath the machine. 10. Once the cable is in the wash tank heater area, route the cable over the highlimit switch. 11. In the control box, attach the red wire from the 6-conductor cable to open tab on the L2 side of the wash motor contactor (R3). See page 12 for a layout of control box components. 12. Locate and remove the two white wires in the single terminal on the water level controller (WL) at the #1 position. Cut the terminals off of the two white wires. See page 12 for a layout of control box components. 3 of 12

CONTROL BOX 13. Trace the two white wires to the back of the control box. On the white wire that enters the wash conduit (from the front of the box, it is the conduit on the far right), strip and crimp a female terminal onto the end of it and then connect it back to the water level controller (WL) at the #1 position where it was removed in Step 12. Rinse Conduit Wash Conduit See page 12 for a layout of control box components. Terminal from the kit is 14. Trace the other white wire that was removed in Step 12 to the rinse conduit (from the front, it is the conduit to the immediate left of the wash conduit). Strip and crimp a male terminal onto the white wire and then connect it to the white wire from the 6-conductor cable. Terminal from the kit is 15. Locate the orange/white wire coming out of the rinse conduit (same conduit as in Step 14) and note it ends with a termination into the rinse heater contactor (R1). Strip and crimp a male terminal on the end that goes to the rinse conduit and a female terminal on the end that goes to the rinse heater contactor. See page 12 for a layout of control box components. 16. Connect the orange/white wire from the rinse conduit to the black wire from the 6-conductor cable. 4 of 12

CONTROL BOX 17. Connect the orange/white wire from the rinse heater contactor to the brown wire from the 6-conductor cable. 18. Replace the control box top using a phillips screwdriver. RINSE BOOSTER! WARNING WARNING! To prevent burns, make sure the machine has been off long enough for the water to cool before draining the booster tank! 19. Place a bucket under the booster. 20. Find the thermostat on the booster tank. Disconnect the orange/white and white wires from the thermostat. 21. Cut the ring terminals off of the orange/white and white wires. Strip and crimp each with a male terminal. Terminals from the kit are NOTICE If Steps 22 and 23 are done rapidly, minimal water will drain from the booster tank. 22. Use a 7/16 wrench on the fitting behind the thermostat. After the fitting is loosened, pull out on the thermostat until the probe is removed from the wash tank. 5 of 12

RINSE BOOSTER Brass fitting from the kit is 23. Slide a 1/4 brass fitting from the kit onto the new rinse probe from the kit. Slide the probe into the hole the same way the rinse thermostat came out. Tighten the fitting on the probe with a 7/16 wrench, making sure to leave 1/4 of the probe exposed. Thermistor Probe Brass Fitting Thermistor probe from the kit is 24. Connect the orange/white wire to the black/white wire from the rinse probe. Connect the white wire to the black wire from the rinse probe. Use a zip-tie to gather the wires. Zip-tie from the kit is used in this step. Use cover and hardware removed in Step 2. 25. Re-attach the rinse heater cover with a 3/8 wrench. WASH TANK! WARNING WARNING! Make sure the drain stopper has been removed and the wash tank drained before proceeding! 26. Disconnect the white/red wire from the wash thermostat as well as from the high-limit switch. Remove the wire completely and discard. 27. Disconnect the white/yellow wire from the wash thermostat. Terminal from the kit is 28. Cut the ring terminal off of the white/yellow wire. Strip and crimp a female terminal to the white/yellow wire. 6 of 12

WASH TANK 29. Use a 7/16 wrench on the fitting behind the wash thermostat. After fitting is loosened, pull out on the thermostat until the probe is removed from the wash tank. Wash Thermostat Wrench on Fitting Thermostat Removed 30. Slide a 1/4 brass fitting from the kit onto the new wash probe from the kit. Brass fitting from the kit is Thermistor probe from the kit is 31. Slide the probe into the hole the same way the wash thermostat came out. 32. Tighten 1/4 brass fitting on probe with a 7/16 wrench, making sure to leave 1/4 of the probe exposed. 1/4 Brass Fitting 33. Using a 5/16 nut driver, remove the two nuts securing the high-limit switch bracket (keep the nuts to re-attach later). Be careful with the thin tubing coiled behind the high-limit switch as you remove the bracket and switch from the studs. Keep hardware! 7 of 12

WASH TANK 34. Place the new thermostat mounting bracket from the kit onto the two studs where the high-limit switch was removed. Thermostat mounting bracket from the kit is 35. Reposition the coil of thin tubing on top of the mounting bracket. 36. Fasten the high-limit switch (with the nuts from Step 33) on top of the mounting bracket to the open studs from Step 33. Use hardware from Step 33. 37. Install the new thermostat onto the mounting bracket using the 6-32 screws from the kit. Make sure the thermostat is configured so the 5-pin connector is at the bottom. Elan electric thermostat from the kit is Screws from the kit are Elan Electric Thermostat 5-pin Connector 38. Connect the 2-pin, 4-pin, and 5-pin connectors to the thermostat. 39. Connect the white/yellow wire removed in Step 27 to the white/yellow wire in slot 3 of the 4-pin connector. 8 of 12

WASH TANK 40. Locate the white wire in slot 4 of the 4-pin connector. It has a blue female terminal and is attached to a white jumper. Plug the blue female terminal into the L1 tab on the thermostat. 41. Locate the white wire in slot 2 of the 4-pin connector. It has a blue female terminal and is attached to the same jumper described in Step 40. Plug the blue female terminal into the top position (normally-closed) on the high-limit switch. 42. Locate the white/red wire in slot 1 of the 4-pin connector. Connect it to the brown wire from the 6-conductor cable. 43. Connect the red wire from the 6-conductor cable to the L2 tab on the thermostat. 44. Connect the black wire from the 6-conductor cable to the orange/white wire in slot 5 of the 5-pin connector. 9 of 12

WASH TANK 45. Connect the white wire from the 6-conductor cable to the white wire in slot 4 of the 5-pin connector. 46. Connect the black wire from the probe to the black wire in slot 2 of the 5-pin connector. 47. Connect the black/white wire from the probe to the black/white wire in slot 1 of the 5-pin connector. 48. Using a zip-tie, coil and secure the black and black/white wires from the 5-pin connector and probe. Zip-tie from the kit is used in this step. 10 of 12

WASH TANK The switches can be moved through the protective film with either a fingernail or flathead screwdriver. 49. Adjust the settings for the thermostat as follows: Set dip switch #1 (rinse) to the 1 position (1 set closest to the numbers and 2, 3, and 4 set away from the numbers). Set dip switch #2 (wash) to the 3 position (3 set closest to the numbers and 1, 2, and 4 set away from the numbers). Set the blue dials as shown below (or mid-position between the two stops). 50. Replace the drain stopper and strainer. 51. Reconnect electrical power at the breaker or disconnect switch. Turn the power switch to the ON position and wait until tanks are heated to setpoints. Run the machine three cycles and check rinse and wash temperatures. 52. Adjust the blue dial on the left until the desired rinse temperature is achieved (between 180 F and 195 F) for the entire rinse cycle. Turning the dial clockwise increases the temperature. Rinse Dial Total adjustment range is ±10 F. 53. Adjust the blue dial on the right until 150 F wash temperature is achieved. Turning the dial clockwise increases the temperature. Wash Dial Total adjustment range is ±10 F. 54. Adjust the strain relief and tighten once in position. Install the new wash tank heater cover from the kit. Replace the front dress panel. Wash tank heater cover from the kit is used in this step. Use hardware removed in Step 2. Use panel and hardware removed in Step 1. 11 of 12

Front CONTROL BOX LAYOUT 12 of 12