PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar abs) Press. (bar g) (kg)

Similar documents
TEMPERATURE-RESISTANT AND HEATED DIAPHRAGM GAS SAMPLING PUMPS

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar absolute) Press (bar g) (kg)

DIAPHRAGM VACUUM PUMPS FOR AUTOCLAVES

DIAPHRAGM VACUUM PUMPS

Vacuum Pumps for moist Gases. Self-drying Vacuum Pump for moist Gases. Series LABOPORT SD N FT Vacuum Pump. Spare parts.

6-2.1 ANKERSMID Diaphragm pump Application No contamination of the media AMP 510/518/530 due to oil-free operation Low maintenance

Laboport Chemically-resistant Laboratory Pumps and Systems

DIAPHRAGM VACUUM PUMP LABOPORT N FT.18

Vacuum Pump V-100 Technical data sheet

DIAPHRAGM PUMP OEM KNF /18 N TRANSLATION OF ORIGINAL OPERATING AND INSTALLATION INSTRUCTIONS ENGLISH

LABOPORT. Chemically-resistant Laboratory Pumps with Modular Accessories. Operating Instructions for Laboratory Pumps. and for LABOPORT Systems

Vacuum Controller with Control Unit VC 900

Vacuum pump systems. Operating Instructions Read and observe these Operating Instructions! SC 950 SEM 950 SH 950 SR 950

Diaphragm pump 4 - headed

THE NEW GENERATION VACUUM PUMP SYSTEM SC

High Output Vacuum/Pressure Pump

Operation Manual. Diaphragm pumps 2-headed. Types MP 101 Zp, MP 201 Ep MPC 101 Zp, MPC 201 Ep

Thermo Scientific Air Cadet

Chemistry diaphragm pumps

Rotary Evaporators. RE100-Pro. LCD Digital Rotary Evaporator. Features:

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

Safe, precise and cost-effective dosing with ProMinent Low-pressure dosing pumps up to 1,000 l/h

Laboratory Diaphragm Pumps for Air Gases Liquids

Heidolph Vacuum System. Heidolph Vacuum System. Vacuum pumps. Vacuum accessories. ROTAVAC valve control. VAC control automatic. ROTAVAC vario control

ROTATORY EVAPORATOR AND PUMPS

Vacuum in the laboratory. products and solutions

Operation Manual. Diaphragm pumps. MP 054 Zp, MPC 054 Zp MP 104 Ep, MPC 104 Ep

The Safest Connections...

Air operated diaphragm pumps. Catalogue 2011 rev 1

OPERATING MANUAL English Chemical Resistant Diaphragm Pump

KNF LABORATORY EQUIPMENT KNOWING WHAT COUNTS

Diaphragm pumps. Operation Manual. Models: 2019C-02 (230V / 50Hz) 2019B-01 (115V / 60Hz) 2019C-50 (230V / 50Hz)

User Manual. Single Diaphragm Dosing Pump SP-177. We set standards. Industriestrasse 56 FAX: FL-9491 Ruggell

MDA-Range of Modular Desiccant Compressed Air System

Rail vehicles without compressed air? Practically inconceivable!

Vacuum generators VADM/VADMI

Compact Gas Conditioning MAK10

Condensate drains WA/PWEA

Rotary evaporator RS 100 PRO

Hei-VAP Precision. for the highest level of accuracy. Vacuum Pumps. RPM Regulated Vacuum Pumps

transport handle gas ballast valve robust design for long life easy to clean integrated oil level window quiet running, minimized vibrations

MP 2401 E, MP 1801 Z, MP 1201 T

System Components and Accessories for Sample Gas Conditioning. Data Sheet 10/ EN June 2004

MULTI-STAGE, MULTI-FUNCTION AND MODULAR INTERMEDIATE VACUUM MODULES SERIES MI

productdatasheet Compressed Air Refrigeration Dryer Efficient compressed air treatment Rev 01_0317 Page 1

NEOTeCHA Reactor Sampling Type PV

vwr.com. L a b o r a t o r y P u m p s + S y s t e m s

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Vacuum Equipment. Manifolds. Traps. Pumps. Adapters. Easy to assemble Ace-Safe connector versions. O-Ring connections. Added safety and versatility

MEMBRAN-DIAPHRAGM LIQUID PUMPS

Mink MV. Claw Vacuum Pumps for Rough Vacuum Industrial Applications. Claw Vacuum Technology by Busch

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

SIHI Dry GD S Sizes S450, S650

WHAT ARE THE SPECIFICATIONS FOR THE VACUUM

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Adsorption Dryers for Compressed Air

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Excellent performance with low operating costs, Energy saving and environmentally friendly

Oil-Sealed Rotary Vane Pumps

TIMER CONTROLLED DRAINS

MVG. Modular Vacuum Grippers. US5

Verd_GB_ FH :22 Uhr Seite 1 C M Y CM MY CY CMY K Rotary Evaporators Probedruck

Vacuum Pump Vacuum Pump

Chemical resistant Vacuum Pumps

SIHI dry Dry running vacuum pumps

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

TIMER CONTROLLED DRAINS

Adsorption Air Dryers

Vacuum and Air Engineers Central Vacuum Systems. Dynavac VA C U U M & A I R S O L U T I O N S

Vacuum generators VAD/VAK

KONDRAIN KONDRAIN HP. Condensate Drains. Intelligent condensate drainage up to 350 bar. Rev 03_ EN

Environmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution.

KNF LABORATORY EQUIPMENT KNOWING WHAT COUNTS

Order by phone Order on-line Order by fax Website

TURBO AND HIGH PRESSURE REGENERATIVE BLOWERS

multi-stage vacuum generators - general information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

TIMER CONTROLLED DRAINS

Vacuum generators VADM/VADMI

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

S-Series Screw. The nnovation. leader

Liquid Ring Vacuum Pumps, Compressors and Systems

DRYVAC SERIES A new idea for smart pumping

Rotary Evaporators designed

Shop. Item Information. Rotavapor R-300 B-305, SJ24/40, C, P+G, WB, 110V. Send item information. Show item in shop. Add item to cart.

Verd_GB_ :55 Uhr Seite 1 C M Y CM MY CY CMY K Rotary Evaporators Probedruck

BINDER Scientific Product Catalog

Operating Instructions

Air. Pressure. Motion. nnnnnnnn

Min Series. Modular Venturi Vacuum Pumps Min Series. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

ROTARY EVAPORATORS EVAPORATION SOLUTIONS

KNF LABORATORY EQUIPMENT KNOWING WHAT COUNTS

Technical data sheet. Lyovapor L-300

Operation Manual. Scroll pumps. Types scrollvac S 10 scrollvac S

Dry, oilfree Diaphragm Pumps

Vacuum generators. Festo core product range Covers 80% of your automation tasks

Shop. Item Information. Interface I-100 For V-100/V-7x0. Send item information. Show item in shop. Add item to cart.

Multi-User Vacuum Systems for up to ten Users LABOBASE

Dry, oilfree Diaphragm Pumps. Highlight NEW MPC 302 Z. 3 Diaphragm Pumps

Transcription:

MINI-DIAPHRAGM VACUUM PUMPS & COMPRESSORS N85, N85.3, N86 SECTION 41.23 N85.3KNI Concept The Mini-Diaphragm vacuum pumps from KNF are based on a simple principal - an elastic diaphragm, fixed on its edge, moves up and down its central point by means of an eccentric. In this way the medium is transferred using elastomeric valves. The pumps are equipped with the patented stress-optimized structured diaphragm, resulting in a high pneumatic performance, a durable product and compact size. Special valves ensure that the product can cope easily with vapor and condensation. Thanks to the KNF modular system, the parts used to transfer the gases can be made from materials with varying degrees of durability. The pumps can be driven by either AC or DC motors. N86KNDC Features Uncontaminated flow No contamination of the media due to oil-free operation Maintenance-free Compact size due to structured diaphragm High performance because of structured diaphragm High level of gas tightness Long product life thanks to structured diaphragm Very quiet and little vibration Copes well with vapor and condensation Cool running motor even when in constant use Ready for assembly Can operate in any installed position N86KNDCB Areas of use The Mini-Diaphragm vacuum pumps offer a high level of performance despite their small size, as well as an excellent price performance ratio. They are required especially in the fields of analysis, medicine and production technology. The pumps are used for pumping gases, taking samples (even liquids in a vacuum) and evacuating vessels. The AC models are suited for use in machinery which is permanent or mains-operated. Mini-Diaphragm pumps for portable and stand-alone equipment require DC power supplies. Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar abs) Press. (bar g) (kg) N 85.3 KNI 5 25 0.3 1.25 N 85.3 KNDC 5 25 0.3 0.72 N 86 KNI 6 100 2.4 1.1 N 86 KNDCB 6 100 2.4 0.56 N 86 KNDC 6.5 100 1.5 0.58

N85.3KNI N85.3KTI N85.3KNDC N85.3KTDC N 85.3 KNI 5 0.3 25 N 85.3 KTI 5 0.3 35 N 85.3 KNDC 5 0.3 25 N 85.3 KTDC 5.5 0.3 35 Protection class IP 00 Voltage/Frequencies (V/Hz) 115/60 Power P 1 (W) 65 Operating current (A) 1.2 DC Motor 6V 12V 24V Operating current (A) 2.8 1.4 0.7 N 85.3 KNI PPS 4) EPDM Neoprene N 85.3 KTI PPS 4) PTFE-coated FFPM 6) 2) See also MODEL CODES FOR EASY ORDERING 4) Phillips Petroleum, registered trade mark 6) Du Pont, registered trade mark N 85.3 KNDC PPS 4) EPDM Neoprene N 85.3 KTDC PPS 4) PTFE-coated FFPM 6) Dimensions 5) (mm) direction of rotation 49 24.5 direction of rotation G1/8 18 118 0.5 43 129 300±30 from motor body 89 104 5) All dimensional tolerances conform to DIN ISO 2768-1, Tolerance Class V N 85.3 KNI N 85.3 KNDC Vacuum atm. Press. Vacuum atm. Press. 48 60 M4 10 61 40 N 85.3 KTI N 85.3 KTDC Vacuum atm. Press. Vacuum atm. Press.

N86KNI N86KTI N86KNDCB N86KTDCB N 86 KNI 6 2.4 100 N 86 KTI 5.5 2.5 160 VERSION WITH BRUSHLESS DC MOTOR N 86 KNDCB 6 2,4 100 N 86 KTDCB 5.5 2.5 160 Protection class IP 00 Voltage/Frequencies (V/Hz) 115/60 Power P 1 (W) 60 Operating current (A) 0.65 DC Motor 12 V 24 V Operating current a) (A) 1.1 0.65 Operating current b) (A) 1.0 0.6 a) for Type N 86 KNDCB b) for Type N 86 KTDCB N 86 KNI PPS 4) EPDM FPM N 86 KTI PPS 4) PTFE-coated FFPM 6) N 86 KNDCB PPS 4) EPDM FPM N 86 KTDCB PPS 4) PTFE-coated FFPM 6) To comply with CE standards (EMC guideliness to EN 55014-1), attention must be paid to the specifications in the operating instructions. direction of rotation N 86 KNI N 86 KNDCB N 86 KTI N 86 KTDCB

N86KNDC N86KTDC (l/min) 1) (bar g) 3) (mbar abs.) N 86 KNDC 6.5 1.5 100 N 86 KTDC 6 1.5 160 3 ) continuous running M4 max. 7 deep DC Motor 6 V 12 V 24 V Operating current a) (A) 2.6 1.3 A 0.65 A Operating current b) (A) 3 1.5 A 0.75 A a) for Type N 86 KNDC b) for Type N 86 KTDC 300±30 from motor body direction of rotation N 86 KNDC PPS 4) EPDM FPM N 86 KTDC PPS 4) PTFE-coated FFPM 6) N 86 KNDC N 86 KTDC - - - - - - - for short periods only

Pump down time for 5L receiver MODEL CODE FOR EASY ORDERING The model code is identical to the order number. It is made up as follows: N 85.3 KN I DC 115 V/60 Hz, IP 00 or 12 V Base model Head connections Head materials OEM Versions with ac (E) or dc motor (DC) Other motor data eg.: In addition the motor data must be given in the purchase order (voltage, frequency, and protection class). In our extensive program you are sure to find the pump you need for your particular application. TECHNICAL DETAILS Maximum permissible gas and ambient temperature 40 C. Motors with other voltages, frequencies and protection classes on request. Head connections N 85.3 Heads in series (2-stage) Accessories Description Order No. Details Silencer 000345 Filter 000346 Hose connector 001936 PA Hose connector 025671 PVDF Rubber foot 024435 for N 85.3/N 86 E

TIPS ON FUNCTION, INSTALLATION AND SERVICE FUNCTION OF KNF DIAPHRAGM VACUUM PUMPS AND COM- PRESSORS An elastic diaphragm is moved up and down by an eccentric (see illustration). On the down-stroke it draws the air or gas being handled through the inlet valve. On the up-stroke the diaphragm forces the medium through the exhaust valve and out of the head. The compression chamber is hermetically separated from the drive mechanism by the diaphragm. The pumps transfer, evacuate and compress completely oil-free. Diaphragm pump INSTALLATION AND OPERATION Range of use: Transferring air and gases at temperatures between +5 C and +40 C Use chemically resistant version for aggressive gases and vapours Permissible ambient temperature: between +5 C and +40 C The standard pumps are not suitable for use in areas where there is a risk of explosion. In these cases there are other products in the KNF program - please ask us for details The pumps are not designed to start against pressure or vacuum; when a pump is switched on the pressure in the suction and pressure lines must be atmospheric. Pumps that start against pressure or vacuum are available on request To prevent the maximum operating pressure being exceeded, restriction or regulation of the air flow should only be carried out in the suction line Components connected to the pump must be designed to withstand the pneumatic performance of the pump Install the pump so that the fan can draw in sufficient cooling air Fit the pump at the highest point in the system, so that condensate cannot collect in the head of the pump - that prolongs working-life. SERVICE The diaphragm and valve plates are the only parts of the KNF diaphragm pumps subject to wear. They are easy to change, as no special tools are needed. If you have any questions, please call our application engineers (see below for contact telephone number). KNF NEUBERGER, INC. Two Black Forest Road Trenton, New Jersey 08691-1810 Phone: 609-890-8600 Fax: 609-890-8323 Web: http://www.knfusa.com KNF reserves the right to make changes. SECTION 41.23 (0913)H