Passive Cooling Systems Air Conditioning Without the Need of Energy

Similar documents
Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Heat sinks for electronic cooling applications

Genie Heated Regulator Installation & Operation Instructions

Performance Data. curus Component Recognized; File No. E IP 20

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

ENCLOSURE COOLING. Glossary

Dräger Flame 2100 Flame Detection

Vortex Enclosure Coolers A/C ATEX

Laird Thermal Systems Application Note. Bi-directional Microcontrollers Monitor and Protect Medical Equipment

Dräger Flame 2500 Flame Detection

Be sustainable while protecting your business

OPENING AN ENCLOSURE and blowing a fan on heat sensitive components

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

Adelaide Homes Design Guide 4 - Winter warming

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Dräger X-am 7000 Multi-Gas Detection

Model 144H. Product Data Sheet , Rev DB February Content

SEALED ENCLOSURE COOLING

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

OPTIBAR DP 7060 Supplementary Instructions

Thermal management for your cabinets!

Model 144H. Product Data Sheet , Rev DB February Content

COOLING OF BIKER S HELMET USING PELTIER MODULE

Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Dräger PIR 7200 Toxic Gas Detection Transmitter

APS-Series 1500VDC OUTDOOR SOLAR INVERTER

PROCESS AUTOMATION APPLICATION AND SELECTION GUIDELINE FIELDCONNEX FIELDBUS INFRASTRUCTURE

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

HEAT PIPES

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

APS-Series 1000VDC OUTDOOR SOLAR INVERTER

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

The Art and Science of Being Cool

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

Cabinet Cooler Systems

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Tempco s process controllers provide integrated solutions to manage your thermal loop system.

Ultra-Thin Flexible Heaters

NEW GENERATION INTELLIGENT CHILLER BOOSTER, ADIABATIC PRE-COOLING SYSTEM

ClampOn DSP Pig Detector

Exp, pressurized systems

DTS Light fittings for explosive atmospheres

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Dräger Flame 2500 (IR3) Flame Detection

Advantages / Characteristics

Our. Heaters. for your Projects

Applications of Thermodynamics: Heat Pumps and Refrigerators

Cellular. Radio. Paging. Microwave/ Satellite Earth Station PCS. Utility Shelters. Mobile Medical Equipment Vehicles. Commercial Buildings CATV

GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

GasAlertMicroClip X3 Specifications

Technical Data. Dimensions

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

NEW GENERATION INTELLIGENT ADIABATIC PRE-COOLING SYSTEM

Dräger Polytron 7000 Fixed gas detector

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

Corporation , Soraji-ro, Paju-si, Gyeonggi-do, Republic of Korea (Postal Code: 10863)

Dräger Flame 2350 (UV&IR) Flame Detection

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

COMPACT FLAME CONTROLLER CFC 2000

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

Dräger Flame 2100 (UV) Flame Detection

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger PIR 3000 Detection of flammable gases and vapours

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Technical Data. Dimensions

Model D12-IR. Digital Gas Transmitter...

Liquid Cooling for HPAs

Gas cooler series TC-Standard+ X2

Dräger Flame 2370 (UV&IR) Flame Detection

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

Hazardous Area Ringers & Loudspeakers

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

Integrated Solutions Low Voltage Systems

Dependable Solutions for Gas Detection

standards: standards:

Application Note Heat Transfer Design Team 7 Compact Inverter Jack Grundemann

Fisher LCP100 Local Control Panel

INSTRUCTION & SERVICE MANUAL

RAWABI ELECTRIC

QUANTUM. Series and features of the energy-efficient chiller series

COMPACT FLAME CONTROLLER CFC 1000

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Downloaded from

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

Description. Applications

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

VERSAFLOW VORTEX Supplementary instructions

1. What are the scales of temperature? What are the formulas to convert among them? Fahrenheit, Celsius, Kelvin

Screw Compressors. HSD Series. Capacities from: 816 to 3044 cfm Pressures from: 80 to 217 psig

TRACENET TM TN SERIES

NJWEA TECH TRANSFER MARCH 1, 2016

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

Transcription:

Passive Cooling Systems Air Conditioning Without the Need of Energy 1 Introduction and Abstract Pipe Lines and Supply Networks often run through remote areas, like deserts, in which no safe power supply is always available. Measuring and supervision might be necessary in these areas too. SCADA systems have usually only small energy consumption and can be powered by solar cells with back-up batteries. PCS Shelter for ADCO SAS project in the UAE/Sahil and Shah The maximum temperatures in the shade can be as high as 58 C and the solar radiation adds additional heat. Without any cooling the temperatures in shelters and housings may exceed 80 C. In these conditions electronic equipment will not function reliably any longer. Active air conditioning systems, such as compressor and absorber air conditioners, require too much energy to function with solar cells. The solution is passive cooling. How does that function? Passive Cooling Systems use the high temperature differences ( T) between day and night, which arise in arid desert regions. The thermal capacity of heat distribution medium, e.g. water, stores the coolness of the night to keep the interior at a moderate temperature during the day. A Passive Cooled Shelter is an integral system consisting of housings with insulation, sun shade, external and internal heat exchangers, heat storage and conveyance of the medium, which must be designed for the specific application. INTERTEC engineered, built and supplied a number of passively cooled cabinets and shelters for projects of customers such as Saudi Aramco, ADCO, TR, Siemens, ABB or Cegelec with the self developed dynamic simulation tool INTERSIM.

2 Function principle Passive cooling systems function by a large heat storage. Water, having a large thermal capacity, is a very good medium for storing and distributing the coolness of the night. Passive Cooling System: Principle External Heat Exchangers Internal Heat Exchangers High Thermally Stratified Water Tank as Heat Storage Passive Cooling System: Day Outside hotter than inside: outside circuit switched off Cold water from the tank cools the interior CD200-2c-Brochure_Passive_Cooler 2

Passive Cooling System: Night The coolness of the night cools the tank: outside circuit active Cold water from the tank cools the interior The 'temperature peaks' are leveled off. Theoretically the cooled interior temperature to maintain is limited to the ambient temperature of the night before. 50 Environment Air in Shelter Tank Heat Exchanger outside Heat Exchanger inside 45 Temperature [ C] 40 35 30 25 6:00 12:00 18:00 0:00 6:00 12:00 18:00 0:00 6:00 Time CD200-2c-Brochure_Passive_Cooler 3

3 Lay Out of the Passive Cooling System with the dynamic simulation tool 'INTERSIM' INTERSIM is based on an electrical comparison model of a resistance network with resistances and capacities. The passive cooling system can be simulated and laid out exactly. INTERTEC has designed, built and performance tested a number of passive cooled shelters. At every project, the theoretical values could be adjusted to the measured values. Therefore the simulation is quite exact meanwhile. The simulation can be based on a simplified outside temperature gradient or, if known in the real, measured temperature trend. CD200-2c-Brochure_Passive_Cooler 4

4 Selection of the Right Type of Passive Cooler The most important parameters to lay out a passive cooler are: the heat dissipation of the equipment in the housing ( average over 24 h ) the night outside air temperature of the night before the hottest day. The max. allowed temperature inside the shelter. The difference between the mentioned temperatures (delta T) is the driving force to transport the heat out of the housing. The numbers mean the approx. cost for the passive cooling system (without housing etc.) CD200-2c-Brochure_Passive_Cooler 5

4.1 FC-PCS : Forced Circulation Passive Cooled Shelters SCADA Shelter for a drinking water pipeline in the UAE/Fujaihra The liquid circulation of this type of passive cooled shelters is operated by 12V DC pumps. The electrical energy consumption averages at only 10 W. totally. The required energy, if not available, can be provided by solar panels. This concept as a rule of thumb doubles the performance of the PCS Why? The performance of a passive cooler is limited by the sum of the temperature differences (delta T). The minimum practical delta T for a natural convection cycle is 3 K. A forced convection by small pumps needs practically no delta T, that saves 2 x 3 K = 6 K, the internal temperature can be 6 K lower at the same size of heat exchangers and tank. Delta T of the heat exchangers Delta T for the natural convection CD200-2c-Brochure_Passive_Cooler 6

Advantages of FC-PCS : Forced Circulation Passive Cooled Shelters heat exchanger position can be designed to practical needs, i.e. at walls => Outside heat exchangers are easy accessible for cleaning after a sand storm. Minimized over all dimensions: Makes it possible to ship the passive cooled shelter in one piece using the ISO container dimensions = moderate shipping cost. Enables Direct cooling of electronic components by conduction Thermal conduction is a much (approx. 10 times) more effective heat transfer mechanism than the convection of air. Heat exchanger, can be mounted directly to the objects that need to be cooled or heated. Redundant, very reliable brush less, magnetic coupled pumps 4.2 PCS : Natural Circulation Passive Cooled Shelter Without any energy supply 4.2.1 SCADA Shelters for 64 well head stations of the ADCO SAS project External Heat Exchanger and Sun Shade Internal Heat Exchangers 8000 l Tank CD200-2c-Brochure_Passive_Cooler 7

4.2.2 SCADA Shelter of an oil pipeline in the Sudan/Muglad A 'classical' passive cooling with liquid cycle by natural convection. With 500 W, very massive pipes are necessary to minimize the flow resistance. The top part with the outside heat exchangers was transported separately and installed on site. CD200-2c-Brochure_Passive_Cooler 8

4.2.3 Analyzer station in a power plant in the Middle East A Classic cabinet with a passive cooling system that does not need any energy. The utilizable volume amounts to approx. 150x100x50cm (HxBxD). Depending on climate conditions an inside temperature can be held by 40 C with an energy dissipation from 30 W to 100 W. The Passive Cooler concept is a simple and competitive alternative for very expensive Exproof airconditioning units. CD200-2c-Brochure_Passive_Cooler 9

4.3 Passive Cooling solutions without heat exchangers 4.3.1 PCM passive cooler Designed for installation of small devices (transmitters or electronic modules) with heat dissipation of 10 W or less to maintain the temperature of the electronics 10 K below the peak ambient temperature. Advantages No energy or power supply required Cost effective Maintenance free IP65 up to IP68, no fan or louvers to reduce the IP rating Very rugged design Solid state, no moving parts PCM Material Mounting Plate Device All components are designed for optimal performance: Arctic PP enclosures with excellent insulation properties and no heat sinks PCM ( phase change material ), a material that melts and freezes at 93 F/ 34 C and stores the resulting energy at this level Optimal installation: no heat sinks to ambient conditions, Good heat transfer between instrument and PCM due to heat conduction. Sun shade, not only on top of the enclosure, but along sides, if necessary CD200-2c-Brochure_Passive_Cooler 10

4.3.2 passive cooled enclosure for the satellite SCADA system of a gas distribution network In this case for a satellite SCADA system of a gas distribution network the electronics had to be proteded against temperature peaks of only few hours. Due to the precisiely defined thermal insulation of the enclosure and the sun shade, the thermal capacity of the leadacid battery is enough, to limit the temperatuer of the SCADA controller to 60 C at a heat dissipation of 5 W. Testing in a climate chamber CD200-2c-Brochure_Passive_Cooler 11

5 Guide Lines for Optimal Specification 5.1 To optimize the temperatures and power means to minimize the cost The temperature differences (delta Ts) in a Passive Cooling System are much smaller than in an active air conditioner. That means that every C, Kelvin or Fahrenheit is very valuable. Example: In a typical application +50 C day / +30 C night the size of heat exchangers and tank to maintain 40 C inside is more than double the size to maintain 45 C. At the other hand it is important to specify the right Wattage of the heat loss of the electrical equipment. Every Watt of heat energy has to be stored during the day and transported to the outside during the night. Please see also the INTERTEC document Every C counts.pdf 5.2 Size Passive cooled shelters should not been oversized. Good thermal insulation is mandatory because the passive cooling system gets very big and expensive when the necessary cooling power is high. Every m² of outside surface causes additional heat ingress. 5.3 Thermal Insulation Very good thermal insulation is the base of the function of a passive cooled shelter. The whole structure has to be designed avoiding thermal short-cuts. At the usual shelter design heat sinks like steel beams, door frames and cable ducts cause a huge loss of cooling energy. 5.4 Transportation To design the shelter layout to a maximum width of 2.28 m (which is the ISO sea container s inside width) can save a lot of transportation and packing cost. It makes sense to pack the completely installed shelter inside an open top ISO container. So it can be transported from the place of manufacturing to the final destination at moderate cost without the danger of being damaged. Seaworthy packing is not necessary because the GRP shelter itself has a high degree of ingress protection and is corrosion resistant. 5.5 Sun Shade To avoid a high additional heat power by sun radiation it is absolutely necessary to place the shelter in the shade. INTERTEC usually ships shelters with an integrated sun shade. It is removable and stored inside shelter during transportation. Ladder for roof access not necessary and useless unless equipment like the solar panels are installed on the roof. Solar panels can be used as sun shade. It is important that the panels are easily accessible to remove the dust after a sand storm. 5.6 Explosion proof requirements Ex Zone: if necessary, the passive cooled shelter has to meet the requirements of IEC 60079-0 ff. (Antistatic, installations etc.) Battery room: if the batteries produce hydrogen during charging, the battery room might be Ex- Zone 2 or 1. CD200-2c-Brochure_Passive_Cooler 12

6 Alternative Solutions for Outdoor Thermal Management Please contact the INTERTEC engineering department to select the optimal solution for you application. 6.1 The Use of Colder Media If cooling water is available, which must be only colder 2-3 K than the required interior temperature, there might not be a need for a water tank. The heat exchanger can be designed accordingly, which simplifies the Passive Cooler. Other Options: filter fan air-to-air heat exchangers instrument air Vortex - cooler Peltier - cooler Electrical heating for condensation protection The silver bullet solution: Avoid cooling by intelligent combination of well insulated enclosure and equipment condensation protection Water Cooled Gas Chromatograph for a Gas Plant in the Gulf area 6.2 Hybrid : Combination of Active and Passive Cooler In this case the active cooler can be laid out small without reserves and redundancy. The passive cooler ( e.g. PCM passive cooler ) acts as a Booster for the hottest hours of the hottest days back-up for some hours until the active cooler is repaired CD200-2c-Brochure_Passive_Cooler 13

6.3 ATEX- Air Conditioning Unit The air conditioning unit has been designed for installation on the external wall of the protective cabinet or shelter. It is suitable for application in the open at ambient temperatures ranging from 35 C to + 55 C. Ex-approval allows for application up to zone 1. The components of the air conditioning unit are accommodated in a corrosion-proof housing made of the same material as the INTERTEC protective cabinets. For custom applications, INTERTEC can supply complete units consisting of an air conditioning unit and a protective cabinet or Explosion Protection ATEX Examination Certificate TÜV 06 ATEX 2958 ATEX Type of protection (Gas) II 2G Ex px mb e IIC T3 (Suitable for Zone 1) CSA Certificate CSA File # 1913298 CSA Type of Protection Class 1, Div. 2, Class 1, Zone 1, Groups A, B, C and D shelter. Protective cabinets can also be supplied in Ex p design. 6.4 ATEX Ex p Purged and Active Cooled Video Surveillance System for a Refinery in Algeria Cold air from an very well insulated INTERTEC GRP shelter for the concentrator with INTERTEC ATEX air conditioner is conducted to very well insulated INTERTEC GRP sandwich camera boxes by hoses. This solves several problems: ATEX Zone 1 certified ( equipment inside non Ex ) Equipment kept cool ( ambient temperature up to 100 C ) Environmental protection ( sand, corrosion ) Theft and vandalism protection CD200-2c-Brochure_Passive_Cooler 14

6.5 ATEX Water Chiller and Analyzer Cabinet For Saudi Aramco Haradh Al Crude Increment III Gas and Oil Separator Plant in Saudi Arabia. A closed loop water/glycol circulation cools the sample and the cabinet of an oil in water analyzer. ATEX 10 kw water chiller Analyzer Cabinet 6.6 Water Cooled Cabinet for Yokogawa GC in Syria Cabinet and process air for the Gas Chromatograph is cooled with cooling water. An explosion proof control system with thermostats and solenoid valves controls the temperature. Air Cooler CD200-2c-Brochure_Passive_Cooler 15

7.1 www.intertec.info 7 Advantages of INTERTEC Passive Cooling Systems No or very small (< 10 W) auxiliary energy needs. high reliability, no or almost no moving parts closed loop system=>no evaporation=>no maintenance Custom designs according for the application and needs. No transition through the roof that could leak Options High wind loads Explosion proof Fire rating ( i.e. F30 ) Earth quake proof Many more No water above electronic panels External Heat Exchangers: Integrated in the sun shade panel Internal Heat Exchangers at sandwich walls don t need much space High thermally stratified storage tank Tank stands solid on the floor GRP sandwich Shelter High IP rating (e.g. IP65) Insulation ensures good K-value and limits required cooling. Optimized design avoids thermal short-cuts and heat sinks Flexible and modular system Chemical and corrosion resistant No maintenance cost Light weights (transport), high stability Complete integration and configuration from one hand INTERTEC can offer in house : Engineering, Lay out Production, Assembly Testing and Documentation Of Shelter Passive Cooling System electrical (power distribution, lighting) and mechanical installations CD200-2c-Brochure_Passive_Cooler 16