Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

Similar documents
Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

Why steam trap survey?

Spiratec R16C Automatic Steam Trap Monitor

STEAM TRAPS

PRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control.

Chapter 2.3: Steam System

TESTING STEAM TRAPS TO KEEP YOUR SYSTEM OPERATING EFFECTIVELY AND EFFICIENTLY

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Steam Trap Inspection Methods And Steam Cost Analysis

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

MAXIFLO EJECTOR SYSTEM AN INNOVATIVE APPROACH TO STEAM CONSERVATION LEVEL 4 BEE ACCREDITED

Steam trapping overview STEAM & CONDENSATE MANAGEMENT SOLUTIONS

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

Steam Traps and Steam Specialties

PIP PNE00004 Steam Trap Guidelines

BASICS OF STEAM TRAPS BASICS OF STEAM TRAPS

MFP14 Automatic pumps. for condensate and other industrial fluids

Steam Site Guide. Steam Site Guide. Heat Exchange Applications - SI Units

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

GESTRA Information A 1.5

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

Bringing Energy Down to Earth

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

MFP14 Automatic pumps for condensate and other industrial fluids

Inverted Bucket Steam Traps

Bringing Energy Down to Earth

Spiratec Steam trap monitoring

spiraxsarco.com/global/us Product Overview A quick guide to products for steam and related industrial fluids

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

STEAM CONSERVATION GUIDELINES

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Inverted bucket steam traps Type OKZ PN6/PN16

FT14 Ball Float Steam Trap (Screwed)

KEEP YOUR TRAP SHUT OR GET THE CONDENSATE OUT

Product overview. the optimum components for every application

Operating and installation instructions

STEAM TRAP ANALYSIS AT PROCESS PLANTS

STAINLESS STEEL TRAP VALVE STATION

So far 2010 is proving to be

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

GESTRA. Product Overview. The optimum components for every application

Steam Conservation Guidelines for Condensate Drainage Steam Trap Sizing and Selection.

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

GESTRA. Product Overview. The optimum components for every application

STEAM TRAPS FOREST PRODUCTS LIBRARY FOREST RESEARCH LABORATORY OREGON STATE UNIVERSITY. Information Reviewed and Reaffirmed. August No.

Steam Conservation Guidelines for. Drainage. Mead O'Brien (800) LP Steam. Condensate. HP Steam RECEIVER TANK HEATER

Disc Type Steam Trap TSD-42

The right trap for the right application.

THERMODYNAMIC STEAM TRAPS

Steam Traps and Steam Trap Testing

How to Trap: Trap Selection and Safety Factors

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

LIQUIDATOR UMT-TD Series Thermodynamic

spiraxsarco.com/uk Condensate recovery in industrial steam systems

UFGS (May 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

PRESSURE MOTIVE PUMP (PMP) APPLICATIONS

Installation, Operating and Maintenance Guide

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Economical and simplified solutions that offer quality and optimum steam trap service.

THERMODYNAMIC STEAM TRAPS

NHS Sustainable Development: 14 th February Reduce Energy Consumption Through Steam System Modernisation. National Key Account Manager

Intelligent System Solutions Steam Air Hot Water

Hoffman Specialty General Catalog

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

Liquid Drainers LIQUID DRAINERS

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

Installation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50

Boiler Steam Supply Piping Basics November 18, ) Q: What kind of condensate traps should be used on vacuum condensate return systems?

Function of the FENIX Hydrodynamic Trap working on Variable Load Applications

Bringing Energy Down to Earth

How to Trap: Steam Tracer Lines

ESCO. Committed. Group of Companies. to help conserve Steam Energy

Steam Trap Selection

Silhouette. Feedwater Heater. Boiler Feedwater

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

Water Fuel + Air for combustion Blowdown

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

CRU-S Series Stainless Steel Condensate Recovery Unit

Installation and Testing of Inverted Bucket Steam Traps Manual

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

How to Trap: Process Air Heaters

Principles of Steam-In-Place

Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.)

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

FACT SHEET 3. Efficient Compressed Air Treatment. How to save energy, reduce costs and help the environment

How to Trap: Troubleshooting

Installation & Maintenance Manual

Pump & Trap Combinations

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

Spirax-Sarco Industrial Thermostatic Steam Traps

Transcription:

STEAM TRAP CHECKING

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

Steam Traps Review - Mechanical Traps Float Inverted bucket - Thermodynamic - Thermostatic

Float trap with thermostatic air vent Air vent Pivot

Ball Float Trap Operation 1 2 3 On start up, thermostatic air vent allows air to bypass main valve. Otherwise air could not escape and the trap would air bind. Condensate reaches trap. Float raises and lever mechanism opens main valve. Hot condensate closes air vent. Condensate discharged at steam saturation temperature. When steam arrives float drops and main valve closes. Main valve is always below water level, preventing leakage of live steam.

Inverted Bucket Trap

Inverted Bucket Trap Operation 1 2 3 4 Vent hole Condensate reaches trap and forms a waterseal inside. The weight of the bucket keeps the valve off its seat. Condensate flows around bottom of bucket and out of the trap. Steam enters the underside and the bucket rises. This raises the lever mechanism and the main valve snaps shut. The enclosed steam condenses and steam escapes through the vent hole.the weight of the bucket pulls the valve off its seat and the cycle repeats. The vent hole in the bucket will bleed air into the top of the trap. The vent hole is small and will vent air slowly. A separate air vent may be required.

Balanced Pressure Thermostatic Trap

Balanced Pressure Thermostatic Trap Operation 1 2 3 On start up, cold air and condensate enter the trap and are freely discharged because the capsule is also cold and the valve is open. As condensate approaches steam temp. capsule warms up. Liquid fill boils, causing vapour pressure, which acts on the diaphragms, to overcome the external pressure within the trap and pushes the valve towards its seat before steam is lost. Valve closes under dynamic effect of condensate flow and flow ceases. The condensate cools. The vapour pressure in the capsule reduces and valve begins to open. Condensate is discharged and cycle continues.

Simple Bimetallic Trap

Bimetallic Plates

Bimetallic Trap Operation 1 2 3 On start up, the bimetallic element is relaxed, and the valve is open. Cooled condensate & air are discharged. Hot condensate flowing through the trap heats the element, and it pulls the valve towards the seat. As discharging condensate approaches steam saturation temperature, the element closes the valve. Condensate surrounds the element, which relaxes & upstream pressure opens the valve. The cycle repeats.

Operation of thermodynamic steam trap

Themodynamic Trap Operation On start up, incoming pressure acts on underside of disc, raising it and allowing air and cool condensate to be immediately discharged. Simultaneously flash steam pressure building up above the disc forces it to seat and close the inlet. The disc also seats on the outer ring, trapping pressure in the chamber. 1 2 3 4 When hot condensate flows up inlet passage into control chamber, it drops in pressure producing flash steam. The high velocity flash steam creates low pressure under the disc and pulls it towards its seat. The pressure in the chamber lowers via condensing of the flash steam above the disc, normally caused by heat loss from the top cap. The disc is raised and the cycle repeats.

Discharge Temperatures of Steam Traps Temp Steam Saturation Curve FT and IB TD BP SM 100 Liquid expansion set at 60C 0 Pressure

TRAP FAILED CLOSED Plant will waterlog Reduced plant output Spoilt product Complaints of underheating Safety hazard - waterhammer Freezing Easy to identify

TRAP FAILED OPEN Waste of energy/money Increases production costs Plumes of steam visible from vents Can cause problems in pipes Plant will still operate Leaking traps can be difficult to identify

The consequences of steam leaks From a 3mm orifice in a trap operating at 10 bar approx 25 kg/h of steam will be lost Over a year of 8400 hours this represents a waste of 19,250 litres of fuel oil

Problems Caused by Leaking Traps IF A TRAP FAILS OPEN Wasted Steam = Wasted Fuel If the orifice in the TRAP is.. 3mm Diameter! Pressure is 10 barg! 25kg/h wasted!=(210,000 kg/yr) At least JD 13,000 Fuel (Oil) 25

Problems Caused by Leaking Traps Energy Calcs. Leaking Steam at 10 barg With ø 3mm orifice leaks 25kg/h Based on 24 hrs/day 7 days per week 50 weeks per year (25x24x7x50)= 210,000 kg/yr At least JD13,000 Fuel (Oil) But how is this calculated? 25

Problems Caused by Leaking Traps Energy Calcs. If condensate is returned at 90 C Steam generation pressure 10 barg Energy cost in the leaking steam (hg 10 bar ) = 2781.7 KJ/Kg If calorific value of fuel is 44,000 KJ/Kg 2781.7 / 44,000 = 0.063 kg net fuel/kg of steam If Boiler efficiency = 80% then 0.063/80% = 0.079 kg gross fuel/kg steam DEN = MASS / VOL VOL = 0.0687 kg / 0.86 ( sden Oil ) VOL = 0.092 L of Fuel to raise 1 kg of steam@10 bar 1 kg of Steam uses 0.092 L Oil @ (0.68 JD/L) = 0.0625 JD 210,000 kg Steam per year = 13137.6 JD per year (Fuel Oil)

Payback? Payback? If cost of trap = JD 160 JD 160 Cost / JD 13000 Oil Saving/year Payback 0.0123 Year = 1 week

Why do Steam Traps Fail? Normal wear and tear Carryover creates scale which can block the trap Poor strainer maintenance - small trap orifices and parts can block or jam due to scale or rust. Acidic condensate can cause corrosion Waterhammer Freezing Incorrect sizing and selection Incorrect installation Inadequate maintenance

To Boiler House Condensate Return Unit Plant 1 Plant 2 Plant 3

How can we locate traps which have failed open or closed?

Single and Double Window Sight Glass Single window Double window

Sight Check

Typical Installation Sight glass NB Fit at least 1 m downstream of blast action traps

Screwdriver Stethoscope Ultrasonic

Sensor Chamber Flow Indicator Connection

Sensor Chamber Flow Balance hole Sensor Condensate flows under the weir

Steam Trap Working Correctly Inlet Sensor Chamber Hole Sensor submerged Weir Condensate

Steam Trap Leaking Steam Inlet Sensor Chamber Sensor Exposed Hole Weir condensate 8 1 10 3 11 5 13 6 15 16

Spiratec Steam Trap Monitoring System

Chamber or integral sensor options R1C automatic trap monitor R16C automatic trap monitor Steam trap with separate sensor chamber Type 30 hand held indicator Steam trap with integral sensor

Hand-held Indicator (Conductivity Only) Indicator cable plugs into sensor chamber or remote test point Red light indicates trap passing live steam Green light indicates trap passing no live steam

Indicator cable connection Single and multi remote test points (Conductivity Only) 11 12 1 10 2 Spiratec R1 Spirax Sarco Limited 9 8 7 6 3 4 5 Spiratec R12

Automatic Multi Trap Monitor (Conductivity and Temperature Sensor) Orange lights indicate trap blockage or waterlogging Set point indicator Red lights indicate trap leaking steam 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 R16C Multi function programming buttons Red light: a trap problem Green light: all traps working normally

R16C cascade installation The R16C can be installed on a cascade basis. One master box will monitor up to 16 x R16C boxes. A red light on the master box will indicate which local box is registering a faulty trap. The local box will identify the specific trap.

TO RECAP Open discharge - needs little experience, but condensate usually into closed system. Sight glass - Useful, needs experience but becomes obscure. Temperature - only shows failed closed. Sound - needs a lot of experience. Conductivity - simple red or green light, hand held indicator shows leaking traps only, electronic versions - single and multi monitors, shows failed open or closed.