Fan Performance and Selection. Overview

Similar documents
Introduction to Fans. The Basics of Fan Principles and Terminology

Ducted Propeller. Airflow Volume

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan

Selecting the Correct Fan

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

The Advantages of Choosing Centrifugal Fans

Rotodynamic Pumps INTRODUCTION:

Selecting Fans and Determining Airflow for Grain Drying and Storage

Water Pumps. turbo-hydraulic pumps, positive-displacement pumps.

DAE Systems. Fan Selection Guide. Section 1: Terminology

Fans: Features and Analysis

FAN ENGINEERING. Surge, Stall and Instabilities in Fans

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

COMMERCIAL HVAC AIR-HANDLING EQUIPMENT. Fans in VAV Systems

SSRG International Journal of Thermal Engineering (SSRG-IJTE) volume 1 Issue1 Jan to April 2015

FANS & BLOWERS ENERGY EFFICIENCY REFERENCE GUIDE TRAINING & SUPPORT

Fan Selection. and Energy Savings

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Twin City Fan & Blower

Agitation and Mixing

Impact of Minimum Fan Efficiency Grade. Dr. John Cermak Executive Vice President ACME Engineering and Manufacturing Corp.

FANS & BLOWERS. Energy Efficiency Reference Guide. Airflow Volume. Ducted Propeller

Analysis and Optimization of Centrifugal Blower Using CFD

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

Mechanical Engineering Laboratory

MECHANICAL VENTILATION

What is the correct type of fan: Axial, radial, diagonal?

Glossary of Terms Laboratory & Fume Exhaust Fans

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

INSTALLATION DO S AND DON TS

Twin City Fan & Blower

ARI 260 Standard: Sound Rating of Ducted Air Moving and Conditioning Equipment

Proposal Information Template Commercial and Industrial Fans and Blowers 2017 Appliance Efficiency Standards

Specially Designed Waste Water & Sewage Pumps

GreenJet Transfer Fans

Australian Journal of Basic and Applied Sciences

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Improving Air Handler Efficiency in Houses

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

Cooling Solutions for High Heat Flux in Dense Packed Servers. Dr. Walter Angelis R&D Manager Aerodynamics Helmut Sebisch Key Account Manager

Fans and Pumps I. Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong

AGN 088 Air Flow and Cooling

Fuji Electronic VFC 084P-5T

FAN WALL Technology. Product

Performance Analysis of Centrifugal Fan by CFD

PEMP RMD M.S. Ramaiah School of Advanced Studies

Effects of Volute Tongue Clearance and Rotational Speed on Performance of Centrifugal Blower Nitin S. Jadhav *, S. R. Patil

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP)

CUSTOM PRODUCTS AND SERVICES GUIDE

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

MAS AIR SYSTEMS, LLC (724) mas-fan.com PRODUCTS AND SERVICES GUIDE

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

A. Codes and Standards that are Standard at the University:

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

Duct Design and Installation

FAN PERFORMANCE AND UTILIZATION OF COMPRESSED AIR IN THERMALPOWERPLANT

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07

1900 Series In-Line Pump

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

HVAC Myths and Realities Trane Engineers Newsletter Live Series

GIVE A FAN A CHANCE Installation Dos & Don ts

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

an ISO 9001 Company Bulletin PR-112

7697 Snider Road, Mason, OH Telephone:

CASE HISTORY: RETROFIT OF COAL MILL EXHAUST FAN STUDY OF FAN PERFORMANCE AND EROSION

Understanding Fan System Effects

Qualification of Fan-Generated Duct Rumble Noise Part 1: Test Facility

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

In accordance with the Department of Labor and Industry s statute , Subd. 11,

Agenda and Objectives

Main Characteristics of Appliances for Transport and Compression of Air

EXPERIMENTAL ANALYSIS OF TIP CLEARANCE AND CHORD LENGTH FOR OPTIMUM DESIGN OF AXIAL FLOW FAN IN AIR COOLED HEAT EXCHANGER

Pharmaceutical Facility Design

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

PRODUCT GUIDE THE NEW YORK BLOWER COMPANY

CAP SERIES SEWAGE AND WASTE WATER PUMPS

Discover ebm-papst for buildings. Energy-efficient fans for a controlled room atmosphere.

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

STANDARD, QUIET AND SUPER QUIET THE MODELLING OF FLOW AND THE REDUCTION OF TURBULENCES

FLOW AND PERFORMANCE INVESTIGATIONS OF CENTRIFUGAL BLOWERS WITH AEROFOIL BLADED IMPELLERS

Calculator for Profit From Retained Product

A REVIEW OF LITERATURE ON DESIGN OF AXIAL FLOW FAN

Model 1750A/ 1770A Dehumidifier Installation Instructions

TYPE VSM/VSMS VERTICAL SPACE MISER PUMPS

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Momentum in Greenhouse Air Movement

Varofoil Controllable Pitch in Motion Fans Compared to Variable Frequency Controlled Fans

EHH SERIES DRAW THROUGH FAN COILS CFM

Design And Analysis Of Centrifugal Pump

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Product Data. Features/Benefits The Aero 39M air handler is the only unit on the market that practically installs itself.

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Destratification Fan Units DRF-VK & DRF-VKM & DRF-OV

CML Northem Blower Inc. Air Movement Equipment

Industrial Fans & Blowers

Transcription:

Fan Performance and Selection References Burmeister, L.C., Elements of Thermal-Fluid System Design, Prentice Hall, 1998. ASHRAE Handbook: HVAC Systems and Equipment, 1992. Overview Common fan types: centrifugal ( squirrel cage ), axial, special designs (including radial) Fan rotation direction (clockwise or counterclockwise) is important because the blades and housing are designed to direct flow only in one direction Pressure drop through the system must be known to choose a fan. Fans are quietest when they operate near peak efficiency; efficiencies are often provided on fan curves. 1

Centrifugal Fans Source: ASHRAE Handbook Centrifugal Fan Operation Fans cause a pressure increase through two methods Centrifugal force is created by the rotation of the column of air trapped between two blades. Kinetic energy is supplied to the air through the impeller Total pressure = velocity head + static pressure Blades are airfoil-type, backward-curved, forwardcurved, or radial (straight) Airfoil-types are complex and expensive but very efficient; they re used for large systems where the cost is justified. 2

Backward-Curved Fan Blades Have a self-limiting power characteristic, so if sized correctly the motor won t overheat or burn out even if conditions change. High efficiency and stable operation make this blade type popular. Choose the operating point to be just to the right of the peak pressure flow rate to achieve both high efficiency and a stable flow rate. This type of fan operates stably because the pressure difference provided by the fan drops if the flow rate goes up. If the opposite were true, increased an increased flow rate would cause increase fan power, which is unstable. Fan Curve, Backward-Curved Centrifugal Blade TP=total pressure SP=static pressure TE=total efficiency=q P total /W shaft SE=static efficiency HP=horsepower Source: Burmeister 3

Radial Blades Similar performance to a backward-curved except that it s easier to overheat because as flow rate goes up, so does power. Easier to maintain, so it s used in dirty situations (easy to clean straight blades, and they don t collect as much) Blades are stronger than other types. Source: Burmeister 4

Forward-Curved Blades Have problems with instability because a specified pressure rise can fit three different flow rates. Burnout can also be a problem because fan power increases with flow rate. Quieter than other fans; used for most furnace blowers Source: Burmeister 5

Axial Flow Fans Common types: propeller, tubeaxial, vaneaxial Tubeaxial: impeller is inside a tube to guide airflow and improve performance Vaneaxial: like a tubeaxial except vanes either up or downstream of the impeller are used to reduce swirl and improve performance Used to deliver large flow rates but small increase in pressure Examples include fans used for ventilation without ductwork, mobile room fans, and fans used to cool computers Tubeaxial fan for computer cooling Tubeaxial fan for ventilation Vaneaxial fan for high air resistance electronics cooling Straightening vanes are located inside tube 6

Vaneaxial Flow Fan Source: ASHRAE Handbook System Pressure Effects Fan curves are typically given in terms of total pressure vs. volumetric flow rate A typical fan running at a fixed speed can provide a greater volumetric flow rate for systems with smaller total pressure drops (if we re to the right of the peak in the fan curve). Total pressure loss=static pressure loss+dynamic pressure loss 1 2 2 Ptotal = ( Pin, static Pout, static ) + ρ ( Vin Vout ) 2 If exit and inlet area of a duct are about the same, the dynamic pressure loss (or gain) may be minimal. 7

Fan Curves Manufacturer will provide a fan curve for each fan he or she produces. The fan curves predict the pressure-flow rate performance of each fan. Choose a fan that gives you the volumetric flow rate you need for your system pressure drop. Choose a fan that has its peak efficiency at or near your operating point. Sometimes will provide data in a table rather than in a graph. Fan Curves Source: ASHRAE Handbook 8

Generalized Fan Curves These kinds of curves can be used to help choose a fan. Source: Burmeister Fan Laws Fan data for geometrically similar fans can be collapsed onto a single curve using dimensionless numbers Q dimensionless flow rate Π 1 = 3 DN dimensionless pressure rise Π = dimensionless power Π = 3 5 3 P ρd N 2 2 2 W ρdn Q=volumetric flow rate D=fan diameter N=fan rotational speed W=fan power ρ=fluid density P=fan pressure rise 9

Fan Laws The laws only apply to aerodynamically similar fans at the same point of rating on the performance curve. Under these conditions, the dimensionless parameters will be constants. For example, if fan operation moves from point 1 to point 2, the values of the dimensionless parameters will not change and thus can be used to estimate system effects. Be careful about using the fan laws to determine the effect of fan speed change you may move to a very different spot on the performance curve, which will invalidate your results. Fan Laws It may be easier to see how these work in a Source: ASHRAE Handbook different form: 10

Fan Laws Law 1 relates to effect of changing size, speed, or density on volume flow, pressure, and power level Law 2 relates to effect of changing size, pressure, or density on volume flow rate, speed, and power Law 3 shows effect of changing size, volume flow, or density on speed, pressure, and power This example applies the fan laws to a case where the fan speed N is changed from 600 to 650 RPM for a fan of a given size. Fan Law Example Source: ASHRAE Handbook 11

Fan Law Example At point D Q 2 =6000 cfm and P t2 =1.13 in of water From Fan Law 1a, at point E Q 1 =6000x650/600=6500 cfm From Fan Law 1b, at point E P t1 =1.13x(650/600) 2 =1.33 in of water Two Fans in Parallel or Series For two identical fans in parallel, you can make your own fan curve by taking the original fan curve and doubling the volumetric flow rate for a given pressure. For two identical fans in series, you can make your own fan curve by doubling the pressure drop for a given volumetric flow rate. Which would be better for cooling computer chasses? 12

Fans in Series and Parallel Fans in series Fans in parallel 13