USER MANUAL Digital CO Monitor Model CO30

Similar documents
Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

Indoor/Outdoor Temperature Alert

USER GUIDE. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester. Model VFM200

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

USER GUIDE Heat Index Psychrometer

USER MANUAL USB Multi-Function Datalogger Model RHT35

Wet Bulb Thermo-Hygrometer Datalogger

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

User's Guide. Pinless Moisture Meter. Model MO257

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

User's Guide. CO 2 Monitor. Model CO200

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

User's Guide. Pinless Moisture Meter. Model MO257

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

Dual Laser InfraRed (IR) Thermometer

User Manual. Humidity-Temperature Chart Recorder. Model RH520

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

ExStik DO600 USER GUIDE. Dissolved Oxygen Meter. 99 Washington Street Melrose, MA Phone Toll Free

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

High Temperature InfraRed Thermometer with Laser Pointer

Dual Laser InfraRed (IR) Thermometer

4-in-1 Humidity, Temperature Airflow and Light Meter

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

Analog Room Pressure Monitor RPC Series

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Wöhler CM 220. Carbon Monoxide Meter. The Measure of Technology. Contents. 1. Important information Specification... 13

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

Introduction. OM-THA2

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

Manual Vane Anemometer PCE-VA 20

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Wireless Humidity/ Temperature Monitor Remote Wireless Sensor

HV2R ROTARY LASER INSTRUCTION MANUAL

INSTRUCTION MANUAL TRC-1490 Wireless Indoor and Outdoor Weather Station

T-32-TS Touchscreen Thermostat. Installation Manual

CDL 210. Operating manual. CO2 Logger. Best.-Nr

Safe Operation Manual. Honeywell IQ Force Gas Detector

Water Tank Level Monitor

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Bacharach Bodyguard 4 User's Guide

A3G Green Rotary Laser SPECIAL EDITION INSTRUCTION MANUAL

SENSIT HXG-2d Combustible Gas Detector

Specifications Minimum Typical Maximum Unit

Digital Cooking Thermometer models / 00282

Carbon Monoxide Transmitter

IPhone: 219/

UltraRAE 3000 Basic Operation Pocket Reference

Model ST-128M Moisture Detector

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Portable Oxygen Monitor OX-07. (Type A) Operating Manual

Interscan Corporation. Instruction Manual Series Compact Portable Analyzer

4-IN-1 PIN/PAD RH MOISTURE METER


Ambient Weather RC-8419 ClearView Radio Controlled Projection Alarm Clock with Indoor Temperature User Manual

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

WBGT Heat Stress Meter

Ambient Weather RC-8461 ClearView Jumbo Atomic Digital Wall Clock with Temperature and Humidity User Manual

QUICK START. FLIR Model MR59. Ball Probe Moisture Meter with Bluetooth

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Operating Instructions Compur Monitox plus

Model OEM-2 INSTRUCTIONS FOR USE

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

WIRELESS MULTI-ZONE DIGITAL THERMOMETER WITH RADIO CONTROLLED CLOCK. Model No (SF Version) Instruction Manual

End To End Optical Beam Smoke Detector. Additional Information

EL-USB-1-LCD Temperature Data Logger with LCD

testo 316-EX gas leak detector Instruction manual

Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual

Wireless Color Weather Station

Smart Temp. ApolloP/n Installation Manual. Version 1.0

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

WIRELESS COLOR WEATHER STATION

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

03 Series: OX-03, CO-03, HS-03 Versions Operator s Manual

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

Reference Manual. MultiVision Gas Detector

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

WIRELESS FRIDGE THERMOMETER Instruction Manual

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

CO2 Monitor Operating Instructions

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

Gas Measurement Instruments Ltd. User Handbook

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

Portable type of Carbon Dioxide Detector Model: GT220

Model: S88907 Instruction Manual DC: WIRELESS COLOR WEATHER STATION

GasAlertMicroClip X3 Specifications

PROCESS ANALYSERS. SERVOFLEX MiniMP (5200) Gas Analyser. Operator Manual. Part Number: A Revision: 8 Language: UK English

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

High Resolution Display WIRELESS COLOR WEATHER STATION

Transcription:

USER MANUAL Digital CO Monitor Model CO30 Additional User Manual Translations available at www.extech.com

Introduction Thank you for selecting the Extech Instruments Model CO30. The CO30 is a 3 in one Carbon Monoxide (CO), temperature measurement, and humidity measurement meter. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) to check for the latest version of this User Guide, Product Updates, and Customer Support. Description Meter Description 1. Compensation adjustment 2. Control button 3. AC Adaptor jack 1 2 4 3 5 4. LCD Display 5. LED indicator Note: Tilt Stand, Wall mount access, and battery compartment located on rear of meter. IMPORTANT SAFETY NOTES The CO30 Carbon Monoxide Monitor is intended for general purpose Air Quality monitoring only, and has not been certified for use pursuant to any state or city safety Carbon Monoxide Alarm or Monitoring requirements. The CO30 Carbon Monoxide Monitor has not been tested by an independent lab to comply with UL 2034 or IAS 6 96 standard. It is the responsibility of the customer to obtain and apply current local, state, and national regulations with regard to CO alarms, monitoring and testing. 2 CO30 en GB_v1.7 11/16

Operation Powering the meter If the meter is supplied without batteries installed, install the supplied batteries in the rear battery compartment to power the meter. Please observe proper polarity. If the meter is supplied with the batteries installed, and a protective battery strip is installed in the battery compartment, remove the protective strip to power the meter. Alternatively, plug the AC adaptor into the jack on the side of the meter and then into an AC power source to power the meter. Normal Operation Mode When switched ON, the LCD displays 0000 for a period of time, depending on the time that the meter has been inactive. The meter will then proceed to the normal mode of operation where the LCD displays the current CO levels in ppm, the Temperature ( C/ F), and RH% (relative humidity) alternately every 6 seconds. Status Indicator LED The Front panel status LED uses a color coding system to inform the user as to the measured CO concentration; Green for Good (<10ppm); Yellow for Caution (10 to 29ppm); Red for Danger (>30ppm). If the LED fails to illuminate, please return the unit for service. Control button The Control button located on the left side of the meter is used to control and program a variety of meter functions. Press and hold the Control button for at least 3 seconds to access the Control Setup Mode. Repeated presses of the Control button cycle through the available parameters. These parameters, in order, are: ZERO Calibration Temperature Unit selection ( C/ F) Temperature compensation (used in conjunction with side potentiometer) Humidity compensation (used in conjunction with side potentiometer) Alarm Beeper Threshold (25, 30, 35, 50, 100, 200 ppm) Factory Default setting reset Escape/Return (abort and return to normal mode) ZERO Calibration Ensure that the Zero Calibration is performed in a clean air environment (no CO gases). Press and hold the Control button for 3 seconds (until appears on the LCD screen) and then press and hold the Control button again to enter the calibration mode ( CAL should appear on the display). 3 CO30 en GB_v1.7 11/16

Release the Control button and wait approximately 20 seconds for the calibration to complete. The meter will display END for 2 seconds when calibration is complete and will then return to the normal mode of operation. Changing Temperature Units C/F When is shown on the display, press and hold the Control button to display the current temperature unit. Momentarily press the Calibration Control button to toggle C and F units. To save setting, press and hold the Control button. The meter will return to the normal mode. Temperature Compensation Adjustment When is shown on the display, press and hold the Control button. The factory default 0.0 value will flash. Turn the compensation potentiometer clockwise to increase the temperature offset or counterclockwise to decrease offset). The range is 5.4 F to +5.4 F ( 3.0 C to +3.0 C). When done, press and hold the Control button to save the setting. The meter will return to the normal measurement mode and will reflect the offset when temperature readings are displayed. Note: To perform an accurate offset adjustment, a standard reference is required for comparison. 4 CO30 en GB_v1.7 11/16

Relative Humidity Compensation Adjustment When is shown on the display, press and hold the Control button to enter the relative humidity compensation adjustment mode. Momentarily press the Control button to make a step change in the RH% offset; the range is 9 to +9 RH %. When done, press and hold the Control button to save the setting. The meter will return to the normal mode. Note: To perform an accurate offset adjustment, a standard reference is required for comparison. Warning: While performing temperature or RH% compensation adjustments do not touch the slotted openings on the meter housing, these are where the sensors are located. Otherwise, accuracy may be compromised. Note: If the meter displays step to the next setting. press the Control button to Alarm Beeper Threshold Selection When is shown on the display, press and hold the Control button. The factory default setting will flash. Momentarily press the Control button to choose a 25ppm, 30ppm, 35ppm, 50ppm, 100ppm, or 200ppm threshold. After the selection, press and hold the Control button to save and return to the normal mode. The alarm beeper prompts personnel to evacuate an area because of the detection of unsafe concentrations of CO. The meter alarms when the CO concentration exceeds the default or user programmed threshold. The beeper may be temporarily silenced for approximately 4 minutes by pressing the Control button. After this time, if the meter continues to detect a CO concentration exceeding the threshold, it will alarm again. For safety purposes, the meter alarm function cannot be completely disabled. 5 CO30 en GB_v1.7 11/16

Revert to Factory Default Settings When is shown on the LCD display, press and hold the Control button to reset the CO30 to its default (factory) settings. Escape/Return Function When is shown on the LCD display, press and hold the Control button for 3 seconds to abort the current programming step and return to the normal measurement mode. Maintenance Low Battery Condition When the battery icon ( ) appears on the LCD, the batteries must be replaced. If the meter is low on battery voltage, erratic or inaccurate CO concentration readings may result. Never use the meter with the low battery icon displayed. Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold. Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end of life devices to a designated collection point for the disposal of electrical and electronic equipment. Troubleshooting Error Codes The following errors may appear on the CO30 display: E 1: CO measurement exceeds specified measurement range E 2: Temperature measurement exceeds specified measurement range E 3: Relative Humidity (RH %) measurement exceeds specified measurement range 6 CO30 en GB_v1.7 11/16

Specifications Display Status LED indicator CO measurement range CO accuracy CO Resolution Operating Temperature Temperature Resolution Operating Relative Humidity RH Resolution Temperature Accuracy Multifunction LCD displays CO concentration, Air Temperature, and Relative Humidity Tri color status indication (Green <10ppm, Yellow: 10 to 29ppm, and Red >30ppm) 0 to 999ppm ±5% of reading or ± 10ppm 1ppm 0 to 50 C (32 to 122 F) 0.1 C (0.1 F) 0 to 95%RH 1% RH ±1 C/1.8 F Relative Humidity Accuracy ±5% Storage Temperature Storage Humidity Alarm functionality Temperature and RH Compensation CO Calibration Zero Calibration Power Meter dimensions LCD display dimensions Weight 20 to 50 C ( 4 to 122 F) 0 to 95%RH (avoid condensation) Meter beeps and displays the alarm bell icon when the CO level exceeds the alarm setpoint (default setpoint is 30ppm, user adjustable) Manual; user adjustable Standard user function Standard user function 4 x AAA batteries or supplied Universal AC adaptor 113 x 108 x 53mm (4.4 x 4.3 x 2.1 in.) 48 x 28mm (1.9 x 1.1 in.) 159g (5.6 oz.) Copyright 2014 2016 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form www.extech.com 7 CO30 en GB_v1.7 11/16