DISPOSAL Please respect the environment! Dispose of the packaging according to the local recycling regulations. Dispose of the appliance at the end of its life span according to environmental consideration AC Adaptor Input: 30V~50Hz 60mA Output: 4V 0.3A Manufactured by: Home Care Technology Co. Ltd. 116, Lane 53, Sec. 3, Jhongjheng Road, Rende Dist., Tainan City 71757 Taiwan, R.O.C. Authorised Representative: Y.Sung Handelsvertretung, Dusselthaler Str.4 4011, Dusseldorf, Germany Ultrasonic Pain Relief Massager INSTRUCTION MANUAL Lightweight and easy to use READ THE INSTRUCTIONS FOR USE CAREFULLY Imported and Distributed by: Tensor Marketing Ltd, Darlington Co. Durham, DL1 1RW Support Line: 0844 441 8448. IN6816 016 Good Ideas This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. Model No. 6816 Please read carefully before use and keep for future reference Imported and distributed by Good Ideas, London NW1 0JP GD6816 016 Good Ideas
EXPLANATION OF ULTRASOUND DIATHERMY INDICATOR AND CONTROLS The Ultrasonic Pain Relief applys therapeutic deep heat for selected medical conditions is a device that applies to specific areas of body ultrasonic energy at a frequency 1 MHz and that is intended to generate deep heat within body tissues for the treatment. USES Relief of pain Muscle spasms Joint contractors Conductive head CONTRAINDICATION The ultrasound diathermy should not be used for the treatment of malignancies. CAUTION Always read instructions on the gel label before attempting to use. Clean vibration head thoroughly before another person uses it to avoid cross-infection of skin diseases Keep out of reach of children. For external use only. Always use the specified accessories in the manual. The use of other parts not approved by the manufacturer may cause harm. AC adaptor type 48-40-0300 CE. Use timer max. 30 minutes on with 30 minutes off. The product complies with the electromagnetic compatibility requirement of EN60601-1- as specified in EEC Directive 93/4/EEC as amended by 007/47/EC. Operation is close proximity (e.g. 1m) to short wave or microwave therapy equipment may produce instability in the simulator output (IEC601--10). Product must not be used in bathroom or areas of high moisture content. This product is for household, indoor use only. Intensity LED indicator Intensity select button Timer LED indicator On/Timer/Off select button Pulse select button DC adaptor input
WHAT YOU WILL FEEL The micro-vibrations are at a cellular level, deep within the tissue, so you should only feel a very slight vibration/tingle on your skin. There will also be moderate warmth from the conductive head. HOW TO USE THE CONDUCTIVE GEL Applying the conductive gel (Sold Seperately) Choose area of skin and use water or alcohol to clean it, then spread the conductive gel on the skin or the device s conductive metal head. Removal After use, please use a tissue paper or soft and wet cloth to clean the skin and conductive metal head. Caution Avoid contamination/cross contamination of conductive gel. Single person use of gel is recommended. PREPARATION FOR USE MAINTENANCE Main Unit: Don t immerse into water, or let it fall from height. Please do not use any chemical to clean the main unit. To clean, wipe with a damp cloth and dry thoroughly. Conductive Gel (Sold Seperately): Always read the gel instructions before use and keep out of reach of children Keep the conductive gel clean. Be sure there is no dust, oil or other foreign material on them. If the gel dries too soon, spread more gel on the probe or skin. After using, make sure to clean the conductive metal head with wet and soft cloth. Store at room temperature in a dry place. Adaptor: User can not re-assemble or change the specification of the adaptor. The product must only be used with the adaptor provided. If product becomes damaged do not use and contact after sales service support for future advice. 1. Please plug in the adaptor, which is supplied with the unit.. Apply conductive gel (sold seperately) to the conductive head or your skin. 3. Press the timer button to turn on the unit. 4. The unit s default time is 5 minutes and intensity is low level. 5. Press the timer button to choose the suitable timer setting; 5, 10 or 15 minutes. 6. Press mode button to choose the suitable intensity level; L, M or H 7. To pause during use, please turn off the unit by pressing the timer button. 8. Press pulse button to choose the output; continuous or intermittent (on time 0.5 seconds off time 0.5 seconds) 9. When the setting time is up, the unit will auto turn off. 10. This device cannot be used without the AC/DC adaptor.
TROUBLESHOOTING Problem Possible Cause Corrective Action No vibration/tingle Settled intensity level zero (unit stand by) Raise the set intensity level Timer count down zero Reset intensity level Temperature higher than settled Lower intensity level Turn off unit Unit broken Call the dealer Intermittent vibration/tingle Temperature too high Lower intensity level Turn off unit Point of contact too dry Spread some gel or hydrocosmetic on the conductive metal head or skin Mixed wave mode Set to ultrasonic mode Unit doesn t turn on Humidity inside unit Dry the unit for more than 4 hours DC connector loose contact or bad contact Replace with new adaptor Adaptor wire broken Replace with new adaptor Unit broken Contact the dealer TECHNICAL SPECIFICATION Input Power: 30V AC/4VDC adaptor Temporal output power: Less than 5W Temporal average intensity: less than 1W/cm Timer: 5/10/15 minutes, three timer setting, default level 5 minutes (± 10%) Ultrasound Frequency: 1 MHz (± 10%) Pulsed Duty cycle: L:1/5%; M:33% ; H:50% (Each ± 10%) Pulse Repetition Rate: 60 HZ (± 10%) Pulse Mode: Continuous or on time 0.5 seconds off time 0.5 seconds (± 10%) Mode: 3 levels of intensity ( L low // M medium // H high) If after using this guide, the unit does not operate properly, the unit should be serviced. Please call your dealer for instruction.