The next generation thermometer from the global leader

Similar documents
the next generation thermometer from the global leader

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

LC2200 Level Controller Installation and Maintenance Instructions

BC3250. Blowdown Controller

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Power Supply Display Module PSDM. Installation and Operation Manual

D5100 Industrial Differential Pressure Transducer

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

EXCELLENCE in Solutions Products Service

HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT

D5100 Industrial Differential Pressure Transducer

Process Alarm Module RTA 421

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

Event Detection System (EDS)

ue short form catalog Leaders in Safety, Alarm & emergency Shutdown

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

Instruction Manual Model A

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

UDC100 Universal Digital Controller Specifications

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

JENCO ELECTRONICS, LTD.

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

PANELBOARD PROTECTION ON A GLOBAL SCALE

Electronic steam boiler controls

M7100 Pressure Transducer

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

UDC 700 Universal Digital Controllers and Indicator Specifications

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

Enclosure Heaters. Zone 1, Zone 2 & Safe Area

Differential pressure gauge with electrical contact type Model: P650 series

SECTION AUTOMATIC TRANSFER SWITCHES

Electronic Pressure Digest. Pressure and Temperature Transmitters

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

U5700 Submersible Liquid Level Pressure Transducer

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

M5800 Pressure Transducer with Rotatable Display

ACCS-30. Multipoint commercial heat-tracing control system

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

LC3000 Level Controller Installation and Maintenance Instructions

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

USER GUIDE. RLH Auxiliary Fan Kit. Description. The leader in rugged fiber optic technology. ENCLOSURE TEMPERATURE CONTROL. RLH Industries, Inc.

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

WLS-T25 Solar Powered Low Intensity Duty & Stand-by Aviation Obstruction Light

Continuous, real-time detection, alarming and analysis of partial discharge events

HTC-915-CONT. Heat-Trace Control system

Series Temperature Controller Instruction Sheet

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

M5200 Industrial Pressure Transducer

Residual Current Devices

DEW POINT HYGROMETER MODEL DPH-2020/2012 BULLETIN DPH-2020/2012 can be used to extend the lower measurement limit of the system.

SITRANS T temperature transmitters A broad product family for every application. sitrans

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

Model OEM-2 INSTRUCTIONS FOR USE

Temperature Controllers

Temperature Control and Monitoring. innovations in heat tracing

More Precision. thermometer // Non-contact IR temperature sensors

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

The A-series Eletta Flow Monitor with local indication and analog output

DP86 Constant Voltage with Fitting

Interactive Catalog Replaces Catalog Pages

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller

SECTION SANITARY SEWAGE PUMP STATIONS

SIMPLIFIED LIGHTING. TRUSTED PROTECTION. CODE MASTER LED LUMINAIRES CLASS I, DIVISION 1

Table of Contents. Protective Relays

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

Plug-in Base, Long Range Sensor E3B2

Dialight. DuroSite LED Linear Fixture - CE. for Indoor and Outdoor Industrial Applications

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

OWNERS MANUAL OPERATION GUIDE

CMT MANUAL 6. NMC SENSORS

M5800 Pressure Transducer with Rotatable Display

TEMPERATURE CONTROLLER

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

The Importance of Pressure Sensors in HVACR Systems

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Temperature Measurement Transmitters for field mounting

C-Bus Four Channel General Input Unit Installation Instructions

Sensor Interface Module Installation/Operation Instructions

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Transcription:

akm oti/wti Remote mount thermometers The next generation thermometer from the global leader Accomplish the most demanding control and alarm configurations Reduce failure costs with reliable AKM bellows operation Minimize installation complexity with all-in-one design Simplify operations by using one family of thermometers for all environmental conditions Product Summary Description Capillary based, mechanical, remote indicating thermometer. Configurations for oil temperature measurement and winding temperature simulation. Features up to 6 adjustable switches for alarm, trip, and cooling system functions and can be equipped with various electronic outputs for SCADA and remote monitoring applications. Application For oil (liquid) or simulated winding temperature indication with integrated features for control or alarm functions. Designed for use where the point of measurement (the well or pocket) is not easily viewed by personnel and requires separate or remote indication.

akm oti/wti remote mount thermometers The next generation thermometer from the global leader Accomplish the most demanding control and alarm configurations Reduce failure costs with reliable AKM bellows operation Minimize installation complexity with all-in-one design Simplify operations by using one family of thermometer for all environmental conditions Over 75 years of experience designing mechanical temperature measurement devices for transformers Over 250,000 capillary type thermometers in service worldwide in all environmental conditions Improved connection ease with a greater number of cable glands; 3xM25 style and 2xM20 style Improved switching flexibility with up to 6 fully configurable switches New and improved swing out case design allows for easy cable connection, switch configuration and testing without removal of the cover Up to 6 fully independent switches flexible enough for most control and alarm schemes Each switch can be specified by switch type, hysteresis range, and set point, without limitation of sequential set points Standard switch rated for up to 15 Amps AC and up to 10 Amp DC, switches also available for higher VDC (magnetic blow out, M.B.O.), and switches for milliamp loads-- see technical specifications for more information Various analog outputs also available (ma, Pt 100, and Cu 10) -- see technical specifications for more information Each switch can be specified with adjustable hysteresis (5 to 25 C) Non-pressurized bellows system avoids problems due to leakage Integrated heating element in bellows for winding temperature indication eliminates extra cost and complexity of accessories to simulate the winding AKM bellows system provides a 260 dial deflection (angle the pointer travels from minimum to maximum) making it easier to interpret temperature reading from a distance Single enclosure design minimizes need for additional accessories such as matching units and heated wells commonly used by other mechanical temperature solutions New hinged cover enables easy access to switch settings and connections during installation while shielding device from elements. Features all captive screws and can be completely removed, if necessary Same installation footprint and mounting options as the previous generation AKM 345 Improved wiring installation with addition of 2 cable glands (for a total of 5) and an increase in size to 3xM25 and 2xM20 versus the previous generation Wide range of options allow for standard use of one thermometer series across a wide array of applications and operating conditions Extreme temperature survivability with polar executions for use down to -60 C Enclosures with IP55 or IP65 rating with numerous mounting configurations available The most flexible switching capabilities available for implementation of any control and alarm configuration? Don t see what you need? QUALITROL regularly creates models with special customer requirements. Contact your local sales representative or QUALITROL Application Engineer to review your special requirements.

The next generation thermometer from the global leader in rugged temperature measurement One family of thermometer for all environmental conditions Enclosures with IP55 or IP65 rating with numerous mounting configurations available including polar executions for use down to -60 C maximum readability System provides a 260 dial deflection (angle the pointer travels from minimum to maximum) making it easier to interpret temperature reading from a distance AKM bellows technology Low-pressure bellows system avoids problems due to leakage for life long accuracy integrated winding simulation Integrated heating element in AKM bellows for winding temperature indication eliminates extra cost and complexity of accessories to simulate winding temperature new CASe design Swing out case design allows for easy terminal block connection, switch configuration and testing without removal of the cover new electronic output KITS Various analog outputs available (ma, Pt 100, and Cu 10) - user upgrade possible via rear access panel NEW 6 switch capability Up to 6 fully independent switches flexible enough for the most demanding control and alarm schemes Improved wiring ACCESS Improved wiring installation case with addition of 2 cable glands (for a total of 5) and an increase in size to 3xM25 and 2xM20 versus the previous generation AKM bellows technology Integrated heating element in AKM measurement bellows simplifies winding temperature indication by eliminating the complexity of accessories to simulate the winding Single enclosure design minimizes need for additional accessories such as matching units and heated wells commonly used by other mechanical temperature solutions CT Probe Compensation bellows automatically compensates for ambient temperature Inside AKM OTI/WTI

Options and accessories Pockets/wells Pockets and wells available to fit all probe types including IEC and ANSI standards Remote indicators Digital and analog indicators available for remote display of temperature measurement For use with 4-20 ma output option Power supply For use with remote indicators and remote electronic outputs when 24 VDC is not available Universal power supply DIN rail mounting Pass through capillary gland For environmental isolation when capillary needs to pass through an enclosure such as the control cabinet Electronic output user upgrade kit Add electronic output capability to units previously purchased without output Upgrade possible through back access panel Boards capable of ma, Pt100, Cu10, and voltage outputs for remote indication and integration with SCADA systems Email info@qualitrolcorp.com www.qualitrolcorp.com

akm oti/wti remote mount thermometers TECHNICAL SPECIFICATIONS Materials Housing Die-cast aluminum, polyester powder coat finish Capillary Lens Copper or copper/nickel with stainless steel jacket UV stabilized polycarbonate (standard), glass optional Mechanical Indication accuracy ±1.5% full-scale Standard measurement range Probe types Winding thermal image Mounting styles Cover Cable glands 0 to 150 C (32 F to 302 F) Standard: 14mm diameter x 156mm length Available: for wells per DIN 42554, ASA C57.12.00 Internal winding simulation: TD50 (up to 2.2A CT max) or TD76 (up to 2.65A CT max) External winding simulation: (AKM 44678) up to 2A CT or (AKM 44674) up to 1,2A CT max, matching unit (AKM 44677) for up to 5A CT max Stainless steel anti-vibration mount (standard), elastomeric seismic mount optional Swing up cover design, fully detachable, with all captive hardware 3 x M25, 2 x M20 Electrical Number of switches 2 to 6 switches (independently specified types) Switch types VAC, VDC, M.B.O. (magnetic blow out for high DC) Switching differential (hysteresis) 10 to 14 C for most dial ranges, optional adjustable differential from 5 to 25 C Switching accuracy Optional remote outputs ± 3% full-scale Current loops: 0 to 1 or 4 to 20mA Voltage: 1-5V and other ranges Resistive: Pt 100 or Cu 10 ohm Environmental Enclosure IP55 (standard), IP65 optional Dielectric isolation (hi pot) Surge withstand capability Ambient operating temperature Storage temperature Humidity Vibration Shock 2500 VAC at 50Hz, 60 seconds, all terminals to ground IEEE C37.90.1 (TD111 output board only) -40 C to 70 C (-40 F to 158 F), polar execution available for -60 C to 70 C (-76 F to 158 F) -50 C to 80 C (-58 F to 176 F) 95% non-condensing relative humidity @ 95 C (203 F) 50Hz/60Hz @ 0.1mm inch displacement, 3-axes 10 G s half-sine, in three orthogonal planes Email info@qualitrolcorp.com www.qualitrolcorp.com

akm oti/wti remote mount thermometers Standard mounting Universal mounting Siesmic mounting QUALITROL Field Services To further improve reliability, QUALITROL provides comprehensive education and on-site commissioning services, maintenance contracts and technical support to all customers worldwide. Emergency response is available on all products and services. About QUALITROL QUALITROL Company LLC manufactures substation and transformer monitoring and protection devices used by electric utilities and manufacturing companies. It is the global leader in sales and installations of transformer asset protection equipment, fault recorders and fault locators. Established in 1945, QUALITROL Company produces thousands of different types of products on demand, each customized to customers unique requirements. 2008 QUALITROL Company LLC, an ISO 9001 system certified company. All rights reserved. Information subject to change without notice. All trademarks are properties of their respective companies, as noted herein. AP-T02-03L-01E. Email info@qualitrolcorp.com www.qualitrolcorp.com