Instructions AutroVu Explosion-Proof Universal Display AV20

Similar documents
Instructions. FlexVu Explosion-Proof Universal Display Unit Model UD Rev: 6/

Instructions FlexVu Universal Display Unit Model UD10 DCU Emulator. 4.2 Rev: 9/

Instructions Electrochemical Toxic Gas Detector GT3000 Series Includes Transmitter (GTX) and Sensor Module (GTS) 5.

Instructions. Explosion Proof Smoke Detector U Rev: 9/

Instructions FlexVu Explosion-Proof Universal Display Unit Model UD Rev: 9/

Instructions. Det-Tronics SmokeWatch Explosion Proof Smoke Detector U Rev: 3/

Nanotechnology Metal Oxide Semiconductor (NTMOS) H 2 S Gas Sensor

Instructions Det-Tronics Standard Gas Panel. 1.1 Rev: 10/

Addendum. HART Communication with the FlexSonic Acoustic Detector. 1.1 Rev: 1/

Addendum HART Communication with the X2200 UV Flame Detector 1.1 4/

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Instructions Infrared Hydrocarbon Gas Detector AutroPoint HC200

Instructions. Nanotechnology Metal Oxide Semiconductor (NTMOS) H 2 S Gas Detector. 2.2 Rev: 6/

INSTRUCTIONS. Eagle Quantum Premier (EQP) Addressable Smoke & Heat (ASH) Module EQ3750ASH. 5.1 Rev: 4/

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Instructions Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL /

Carbon Monoxide Transmitter

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

ULTIMA X5000. MSAX5000.com

S5000 Gas Monitor. GMS5000.com

Model D12-IR. Digital Gas Transmitter...

Instructions Model MIR MSHA Approved IR Gas Detector 3.1 7/

Instructions. Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL Rev: 3/

Document TM777030, rev. B. Initial release: 22 January 2008 Current release: 16 February 2010

Danfoss gas detection unit Type GD Heavy Duty

Instructions Infrared Hydrocarbon Gas Detector AutroPoint HC300PL

Dräger Polytron 5100 EC Detection of toxic gases and vapors

AutroFlame X33AF. Addendum. Multi-spectrum IR flame detector. Protecting life, environment and property...

Fisher LCP100 Local Control Panel

Instructions

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

HART TOCSIN 903 SINGLE CHANNEL GAS DETECTOR USER INSTRUCTIONS. Oliver IGD Limited NEW WITH OPTIONAL. 4a Pepper Road Stockport SK7 5BW England

DET-TRONICS INSTRUCTIONS. Infrared Hydrocarbon Gas Detector. PointWatch Eclipse Model PIRECL APPLICATION OPERATION OVERVIEW

Instructions Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL Rev.10/

Instructions. PointWatch TM Infrared Hydrocarbon Gas Detector Model PIR Rev: 9/

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Flame 2500 Flame Detection

Dräger Flame 2100 Flame Detection

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

DET-TRONICS INSTRUCTIONS. Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL APPLICATION OPERATION OVERVIEW

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Dräger Flame 2500 (IR3) Flame Detection

RAEGuard 2 PID. User Guide

Instructions. FlexSight LS2000 Line-of-Sight Infrared Hydrocarbon Gas Detector. 4.2 Rev: 8/

INSTRUCTIONS. PointWatch Infrared Hydrocarbon Gas Detector PIR9400

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

Model 144H. Product Data Sheet , Rev DB February Content

Dräger Polytron 5720 IR Toxic Gas Detection

Instructions xwatch Explosion-Proof Camera X /

FUNCTIONAL SAFETY MANUAL

Certificate of Compliance

Rosemount 4500 Hygienic Pressure Transmitter. Start

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Dräger Polytron 5100 EC Detection of toxic gases and vapors

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Certificate of Compliance

Instructions Oxygen Controller R8471C 2.1 8/

INSTRUCTION MANUAL Detcon Model DM-700

Dräger Flame 2350 (UV&IR) Flame Detection

MODEL: O ELECTROCHEMICAL O2 DETECTOR (Used with ST1400 O2 Sensor) Part Number: MAN Rev. 0

INSTRUCTION MANUAL Detcon Model IR-700

Instructions Infrared Hydrocarbon Gas Detector AutroPath HC600

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Flame 2100 (UV) Flame Detection

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Design Manual Installation Operation Maintenance

Dräger Polytron 8000 Stationary gas detector (EC)

Model 144H. Product Data Sheet , Rev DB February Content

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

SEC 5000 IREvolution Gas Detector

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

Rosemount 3490 Series

Rosemount 644H and 644R Smart Temperature Transmitters

Dräger Flame 2370 (UV&IR) Flame Detection

Dräger Polytron 8100 EC Detection of toxic gases and vapors

UNI-TRAN PREMIUM PLUS TOXIC GAS DETECTOR USER MANUAL UT-P+-STXXXX

MBCE-110/230FR Flame Sensor Module

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

SEC Signature Process Gas Analyzer

Remote Relay Module (RRM)

Dependable Solutions for Gas Detection

Dräger Flame 2700 (Multi-IR) Flame Detection

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

Gas Detection System SGAES-TG Operating Manual R01

Instructions Multispectrum IR Flame Detector with Pulse Output X Rev: 12/

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Instructions. Infrared Hydrocarbon Gas Detector Open Path Eclipse Model OPECL Rev: 12/

Analog Room Pressure Monitor RPC Series

Operation & Maintenance Manual

Transcription:

Instructions AutroVu Explosion-Proof Universal Display AV20 Instructions, AutroVu Explosion-Proof Universal Display AV20, 116-P-AV20/IGB, Rev. C, 2014-04-25 P/N 95-8687.3.1, rev. 10/12

COPYRIGHT This publication, or parts thereof, may not be reproduced in any form, by any method, for any purpose. and its subsidiaries assume no responsibility for any errors that may appear in the publication, or for damages arising from the information in it. No information in this publication should be regarded as a warranty made by Autronica Fire and Security. The information in this publication may be updated without notice. Product names mentioned in this publication may be trademarks. They are used only for identification.

Table of Contents APPLICATION.... 1 DESCRIPTION.... 1 HART Communication... 2 Magnetic Switches... 2 Device Enclosure... 2 Device Display... 2 Logging.... 2 Output Test.... 2 Real Time Clock.... 2 IMPORTANT SAFETY NOTES.... 3 INSTALLATION.... 3 Identification Of Vapor(s) To Be Detected........... 3 Identification Of Detector Mounting Locations....... 3 Device Mounting Orientation.... 4 Sensor Separation... 4 WIRING.... 4 Power Supply Requirements... 4 Wiring Cable Requirements... 4 Wiring Procedure... 4 CALIBRATION.... 6 General Calibration Information... 6 Calibration Procedure.... 7 Input Trim... 7 SPECIFICATIONS.... 7 DEVICE REPAIR AND RETURN.... 10 ORDERING INFORMATION.... 10 APPENDIX HART COMMUNICATION.... A-1

INSTRUCTIONS AutroVu Explosion-Proof Universal Display Unit Model AV20 IMPORTANT Be sure to read and understand the entire instruction manual before installing or operating the gas detection system. The Model AV20 is to be used with the GT3000 to provide early warning of the presence of a toxic gas mixture. Proper device installation, operation, and maintenance is required to ensure safe and effective operation. If this equipment is used in a manner not specified in this manual, safety protection may be impaired. APPLICATION The AutroVu Model AV20 Universal Display Unit is designed to be used with the GT3000 Toxic Gas Detector. It is recommended for applications where a 2-wire loop powered gas detector is required. The output is a 4-20 ma signal with HART, corresponding to the output of the GT3000 detector. Gas concentrations are displayed on an alpha-numeric display in ppm (% for O 2 ). The display unit reads the linear 4-20 ma DC output signal from the GT3000 that corresponds to the detected gas concentration. The AV20 automatically detects the gas type and operating range of the sensor to which it is connected via the HART signal. All electronics are enclosed in an explosion-proof aluminum or stainless steel housing. The display unit is used with a single GT3000, which may be either directly coupled to the display unit, or remotely located using a sensor termination box. The AV20 features non intrusive calibration, which can be performed by using a handheld magnet to activate internal magnetic switches on the faceplate. Calibration can also be performed by activating the GT3000 s internal magnetic reed switch with a magnet. DESCRIPTION The AV20 provides display and control capabilities for the GT3000, and utilizes the following I/O: Signal Inputs: User Inputs: Visible Outputs: Signal Outputs: 4-20 ma loop with HART, from the GT3000 Magnetic switches (4) on the display panel LCD display 4-20 ma with HART, from the GT3000 Page 1

HART COMMUNICATION The AV20 is a HART primary master and communicates with the GT3000, which is a HART slave device. Upon power-up, the AV20 requests the gas type, gas range, and unit of measurement from the GT3000. During normal operation, the AV20 continually polls the GT3000 for status information. Because the AV20 is a primary master, a secondary master can also be used to communicate with the GT3000 at the same time. If an Asset Management System (AMS) is used, it should be configured as a secondary master to avoid communication conflicts with the AV20. MAGNETIC SWITCHES Four internal magnetic switches provide a non intrusive user interface that allows adjustment of configuration parameters and calibration in the field without the use of a HART handheld device. The switches are labeled as follows: Cancel, Escape DEVICE ENCLOSURE The housing for the AV20 consists of a multi port aluminum or stainless steel explosion proof junction box with a clear viewing window. Available conduit entry sizes include 3/4 inch NPT and M25. DEVICE DISPLAY The AV20 is provided with a 160 x 100 dot matrix LCD display. See Figure 1. During normal operation, the LCD display indicates the gas type and units measured. The AV20 communicates with the sensor and allows easy access to the following information: Sensor information/fault/status Transmitter information/fault/status Gas type and measurement range History, event, and calibration logs Refer to Appendix A for details regarding the HART menu structure. Enter, Select Previous LOGGING The AV20 has no logging capability of its own, but reads the logs that are stored in the GT3000 and displays them on the LCD screen. If an AMS is used, it communicates directly with the GT3000 and not with the AV20. Next AV20 GT3000 GAS DETECTOR CONTROL SYSTEM B2426* Figure 1 Faceplate of AV20 PREVIOUS CANCEL / ESCAPE ENTER / SELECT NEXT Operating and history logs that are stored in the GT3000 and displayed by the AV20 include: Calibration Sensor running hours Sensor temperature Events OUTPUT TEST The AV20 can start and stop a 4-20 ma Loop Test for checking correct operation of system output devices. REAL TIME CLOCK The Real Time Clock resides in the GT3000 can be set by the AV20, HART handheld, or AMS. The AV20 reads and displays the current time/date from the GT3000. Page 2

IMPORTANT SAFETY NOTES INSTALLATION CAUTION The wiring procedures in this manual are intended to ensure proper functioning of the device under normal conditions. However, because of the many variations in wiring codes and regulations, total compliance to these ordinances cannot be guaranteed. Be certain that all wiring complies with the NEC as well as all local ordinances. If in doubt, consult the authority having jurisdiction before wiring the system. Installation must be done by a properly trained person. CAUTION This product has been tested and approved for use in hazardous areas. However, it must be properly installed and used only under the conditions specified within this manual and the specific approval certificates. Any device modification, improper installation, or use in a faulty or incomplete configuration will render warranty and product certifications invalid. CAUTION The device contains no user serviceable components. Service or repair should never be attempted by the user. Device repair should be performed only by the manufacturer or trained service personnel. LIABILITIES The manufacturer s warranty for this product is void, and all liability for proper function of the Display is irrevocably transferred to the owner or operator in the event that the device is serviced or repaired by personnel not employed or authorized by Autronica Fire and Security, or if the device is used in a manner not conforming to its intended use. CAUTION Observe precautions for handling electrostatic sensitive devices. CAUTION Unused entries must be closed with suitably certified blanking elements upon installation. NOTE The AV20 housing must be electrically connected to earth ground. A dedicated earth ground terminal is provided on the AV20. Install gas detectors in the appropriate locations following the guidelines below. The AV20 should be located where it can be easily viewed by personnel. The GT3000 can be attached directly to the AV20 housing, or it can be mounted remotely using an STB termination box (see Sensor Separation for additional information). Detectors must always be installed per local installation practices. Always define the following application details: IDENTIFICATION OF VAPOR(S) TO BE DETECTED It is necessary to always identify the vapor(s) of interest at the job site. In addition, the fire hazard properties of the vapor, such as vapor density, flashpoint, and vapor pressure should be identified and used to assist in selecting the optimum detector mounting location within the area. IDENTIFICATION OF DETECTOR MOUNTING LOCATIONS Identification of the most likely leak sources and leak accumulation areas is typically the first step in identifying the best detector mounting locations. In addition, identification of air current / wind patterns within the protected area is useful in predicting gas leak dispersion behavior. This information should be used to identify optimum sensor installation points. If the vapor of interest is lighter than air, place the sensor above the potential gas leak. Place the sensor close to the floor for gases that are heavier than air. Note that air currents may cause a gas that is slightly heavier than air to rise under some conditions. Heated gases may also exhibit the same phenomenon. The most effective number and placement of detectors varies depending on the conditions at the job site. The individual designing the installation must often rely on experience and common sense to determine the detector quantity and best locations to adequately protect the area. Note that it is typically advantageous to locate detectors where they are accessible for maintenance. Locations near excessive heat or vibration sources should be avoided if possible. Final suitability of possible gas detector locations should be verified by a job site survey. Page 3

WIRING GND LUG GREEN LED CALIBRATION NOTCH Figure 2 Correct Mounting Orientation DEVICE MOUNTING ORIENTATION The gas detector must be mounted in a vertical position only, with the sensor pointing down. See Figure 2. IMPORTANT The GT3000 must be oriented with the LEDs facing forward so they are easily visible to personnel within the area. To ensure correct orientation (the LEDs are not visible when power is off), position the GND lug on the left hand side and the calibration notch to the front. Note that the LEDs are located directly above the calibration notch. SENSOR SEPARATION B2436* Autronica sensor termination boxes (Model STBs) enable the installation of the GT3000 separately from the AV20 Universal Display Unit. Two conductor shielded cable is required to prevent possible nuisance EMI/RFI. The maximum cable length between the termination box and the AV20 is 2000 ft. POWER SUPPLY REQUIREMENTS Calculate the total gas detection system power consumption rate in watts from cold start-up. Select a power supply with adequate capability for the calculated load. Ensure that the selected power supply provides regulated and filtered 24 Vdc output power for the entire system. If a back-up power system is required, a float type battery charging system is recommended. If an existing source of 24 Vdc power is being utilized, verify that system requirements are met. NOTE The AV20 and GT3000 communicate using HART protocol, which requires a power supply with low noise levels for proper operation. (For detailed information regarding power supply specifications, refer to the HART Communication Foundation s document FSK Physical Layer Specification HCF_SPEC-54.) WIRING CABLE REQUIREMENTS Always use proper cabling type and diameter for input power as well as output signal wiring. 22 AWG (0,32 mm 2 ) to 14 AWG (2,08 mm 2 ) shielded stranded copper wire is recommended. Always install a properly sized, master power fuse or breaker on the system power circuit. NOTE The use of shielded cable in conduit or shielded armored cable is required. In applications where the wiring is installed in conduit, dedicated conduit is recommended. Avoid low frequency, high voltage, and non-signaling conductors to prevent nuisance EMI problems. CAUTION The use of proper conduit installation techniques, breathers, glands, and seals is required to prevent water ingress and/or maintain the explosion-proof rating. WIRING PROCEDURE Refer to Figures 3 and 4 for wiring illustrations. Page 4

RED HAZARDOUS LOCATION NON-HAZARDOUS LOCATION AV20 DISPLAY UNIT + J2-6 + POWER LOOP J2-5 SEE NOTES 2 AND 3 24 VDC RED SHIELD J2-4 J2-3 + SEE NOTE 5 BLACK J2-2 SENSOR LOOP GREEN SEE NOTE 1 J2-1 SHIELD J2 GT3000 GAS DETECTOR NOTE 1 NOTE 2 NOTE 3 NOTE 4 CONNECT THE GREEN SENSOR LEAD TO THE CHASSIS GROUND LUG ON THE INSIDE BOTTOM OF THE AV20 DISPLAY UNIT ENCLOSURE. 250 OHM RESISTOR REQUIRED (INCLUDED). EXTERNAL HART COMMUNICATION DEVICES CAN BE CONNECTED ACROSS THE 250 OHM RESISTOR, ACROSS J2-5 AND J2-6, OR ACROSS J2-2 AND J2-3. JUNCTION BOX MUST BE ELECTRICALLY CONNECTED TO EARTH GROUND. NOTE 5 GROUND THE SHIELD AT THE POWER SOURCE END ONLY. B2406* Figure 3 Basic Wiring for Explosion Proof AV20 with GT3000 HAZARDOUS LOCATION NON-HAZARDOUS LOCATION AV20 DISPLAY UNIT + J2-6 + SENSOR TERMINATION BOX POWER LOOP SHIELD J2-5 J2-4 SEE NOTES 2 AND 3 24 VDC SEE NOTE 1 GREEN RED BLACKBLACK RED BLACK SEE NOTE 1 J2-3 J2-2 J2-1 J2 + SHIELD SENSOR LOOP GT3000 GAS DETECTOR NOTE 1 NOTE 2 NOTE 3 GROUND THE SHIELD AT THE POWER SOURCE END ONLY. 250 OHM RESISTOR REQUIRED (INCLUDED). EXTERNAL HART COMMUNICATION DEVICES CAN BE CONNECTED ACROSS THE 250 OHM RESISTOR, ACROSS J2-5 AND J2-6, OR ACROSS J2-2 AND J2-3. NOTE 4 JUNCTION BOXES MUST BE ELECTRICALLY CONNECTED TO EARTH GROUND. B2483* Figure 4 Basic Wiring for Explosion Proof AV20 and GT3000 with Terminal Box Page 5

Table 1 GT3000 LEDs During Calibration Device Status Green LED Yellow LED Normal Steady On Off Waiting for Zero Off Steady On Waiting for Gas Off Blinking Waiting for Span Off Blinking Remove Cal Gas Off Off Normal Steady On Off Function Table 2 GT3000 LEDs and 4-20 ma Output During Various Status Conditions Green LED Yellow LED Analog 4-20 ma Signal Warm-up Off Steady On 3.5 Normal Operation Fault Condition Steady On Off 4-20 Off Steady On 3.5 Calibration See Table 1 3.8 CALIBRATION The calibration process is automatic, with the exception of gas delivery. LEDs on the GT3000 and messages on the AV20 faceplate guide the operator when to apply and remove the calibration gas. See Table 1. NOTE The AV20 allows the operator to adjust the calibration gas concentration within the range of 30 to 90% full scale. The default value for all gas sensors except oxygen is 50% full scale. Oxygen sensors use a default value of 20.9%. GENERAL CALIBRATION INFORMATION All GT3000 Gas Detectors require a two-point calibration zero and span. The calibration process can be initiated using the magnetic switch on the GT3000 or using the magnetic switches on the AV20 faceplate. All sensors, including oxygen, should be in clean air (20.9% oxygen) when the calibration sequence is initiated. Once calibration is initiated, the process proceeds automatically. The yellow LED on the GT3000 and the digital display on the AV20 are used to inform the operator of the progress of the calibration procedure, and also signal when to apply and when to remove the calibration gas. The calibration can be aborted after zero calibration by activating the magnetic switch on the GT3000 or navigating the AV20 menu. If the calibration sequence is aborted or not completed successfully, the detector reverts back to the previous calibration values and signals a calibration fault. If a successful calibration cannot be performed, the calibration fault can be cleared by activating the magnetic switch on the GT3000 for one second. For help assessing when a fault has occurred, see Table 2. The calibration process can fail for the following causes: Zero is out of range Span is out of range Time-Out. The time and date of calibration events are logged in the GT3000 s non volatile memory along with the calibration outcome. Possible calibration scenarios include the following: Successful Calibration Aborted Calibration Failed Calibration NOTE The calibration procedure must be completed within a ten minute period. If the calibration is not completed, a calibration fault will be generated and the previous calibration data will be used. NOTE To ensure reliable protection, it is important to check and calibrate the detection system on a regularly scheduled basis. The frequency of these checks is determined by the requirements of the particular installation typically 30, 60, or 90 day intervals, depending on the ambient conditions. Page 6

INPUT TRIM The input current loop of the AV20 is trimmed at the factory. However, it can also be trimmed in the field using the following automated process. LED Navigate through the menu to Input Loop Cal. A2452 PLACE MAGNET HERE TO ACTIVATE INTERNAL MAGNETIC SWITCH Main Menu Process Vars Display Status Device Status Device Setup Device Cal Device Test Device Setup HART Option RTC Write Protect Input Loop Cal Contrast Control Figure 5 Location of Magnetic Switch on GT3000 Detector CALIBRATION PROCEDURE 1. Clean air must be present at the sensor prior to initiating calibration. The use of bottled air is recommended. 2. Calibration can be initiated in one of two ways: A. Hold the calibration magnet against the designated location on the sensor module (see Figure 5) until the green LED turns off and the yellow LED turns on steady (approximately one second). B. Initiate calibration via the magnetic switches on the AV20. Select Main Menu > Device Cal > Calibration > Execute. The AV20 indicates Waiting for Zero. The transmitter immediately begins taking zero readings. 3. When the zero calibration is complete, the yellow LED changes from steady to blinking and the AV20 indicates Waiting for Gas. Apply the calibration gas to the sensor. When gas is detected, the AV20 indicates Waiting for Span. 4. When the yellow LED turns off and the AV20 indicates Remove Cal Gas, remove the calibration gas. The gas level at the sensor gradually returns to zero. The green LED turns on steady to indicate that the device has returned to normal operation, using the new calibration data. Upon entering Input Loop Cal, the AV20 commands the detector to output 4 ma, and then automatically calibrates its own input. The AV20 then commands the detector to output 20 ma, and subsequently calibrates its own input. SPECIFICATIONS OPERATING VOLTAGE 24 Vdc nominal, operating range is 19 to 30 Vdc. AV20 maximum loop voltage drop (Vd) 5.0 volts. Maximum loop supply 30.0 Vdc. OPERATING POWER 0.8 watt maximum. OPERATING CURRENT A minimum of 3.5 ma. CURRENT OUTPUT Linear 4-20 ma with HART output directly from GT3000. 250 ohm termination resistor is required (included). OPERATING TEMPERATURE 20 C to +70 C. STORAGE TEMPERATURE 40 C to +70 C. HUMIDITY RANGE 5 to 95% RH (Autronica verified). SENSOR COMPATIBILITY The AV20 can be used with any of the Autronica GT3000 line of gas detectors. Page 7

6.48 (16.5) 3.46 (8.8) 4.7 (11.9) 5.2 (13.2) 5.86 (14.9) 11.28 (28.7) R0.175 A2442 Figure 6 Dimensions of AV20 with GT3000 in Inches (Centimeters) WIRING TERMINALS Terminals can handle wire sized from 22 AWG (0,32 mm 2 ) to 14 AWG (2,08 mm 2 ). CONDUIT ENTRIES 3/4 NPT or M25. (Five conduit entries standard.) ENCLOSURE MATERIAL Epoxy coated aluminum or 316 stainless steel. SHIPPING WEIGHT Aluminum: 4.15 pounds (1.88 kilograms). Stainless steel: 10.5 pounds (4.76 kilograms). DIMENSIONS See Figures 6 and 7. ELECTRO-MAGNETIC COMPATIBILITY EMC Directive 2004/108/EC EN55011 (Emissions) EN50270 (Immunity) WARRANTY 12 months from date of installation or 18 months from date of shipment, whichever occurs first. Page 8

5.86 (14.9) 2.7 (6.9) 5.2 (13.2) CERTIFICATIONS FM: Class I, Div. 1, Groups B, C & D; Class I, Div. 2, Groups B, C & D (T4); Class I, Zone 1/2 AEx d IIC T6; Class II/III, Div. 1/2, Groups E, F & G. Tamb 20 C to +70 C NEMA/Type 4X, IP66 Conduit seal not required. 4.7 (11.9) 3.46 (8.8) Performance verified in accordance with: ANSI/ISA-92.00.01 ANSI/ISA-92.02.01 FM 6341 (Draft) ANSI/ISA-12.13.01 ANSI/ISA-12.13.04/FM 6325 FM 6310/6320 3.77 (9.6) 1.28 (3.3) Figure 7 Dimensions of Model STB Termination Box in Inches (Centimeters) C2281 CSA: CSA 08 2162793. Class I, Div. 1, Groups B, C & D; Class I, Div. 2, Groups B, C & D (T4); Class II/III, Div. 1/2, Groups E, F & G. (Tamb = 20 C to +70 C) Type 4X, IP66 Conduit seal not required. ATEX: 0470 II 2 G Ex d IIC T6 Tamb 20 C to +70 C FM13ATEX0101X IP66 Performance verified in accordance with: EN 61779-1/-4 and EN 50241-1/-2. IECEx: Ex d IIC T6 Tamb 20 C to +70 C IECEx FMG 13.0042X IP66 Performance verified in accordance with: IEC 61779-1, -4. INMETRO CEPEL 12.2128 Ex d IIC T6 Gb IP66 T6 (Tamb 20 C to +70 C) All cable entry devices shall be Brazil certified in the type of explosion protection, flameproof enclosure d, suitable for the conditions of use and correctly installed, with an ingress protection rating of IP66. A screw or cover lock is provided for a secondary means of fastening the cover. Page 9

DEVICE REPAIR AND RETURN Prior to returning devices, contact the nearest local Autronica office so that a Return Material Identification (RMI) number can be assigned. A written statement describing the malfunction must accompany the returned device or component to assist and expedite finding the root cause of the failure. Pack the unit properly. Always use sufficient packing material. Where applicable, use an antistatic bag as protection from electrostatic discharge. NOTE Inadequate packaging that ultimately causes damage to the returned device during shipment will result in a service charge to repair the damage incurred during shipment. Return all equipment transportation prepaid to the factory in Trondheim. NOTE It is highly recommended that a complete spare be kept on hand for field replacement to ensure continuous protection. ORDERING INFORMATION Sensor module, Transmitter module and termination boxes (if used) must be ordered separately. Refer to the AV20 Model Matrix for ordering details. REPLACEMENT PARTS Part Number Description 116-009700-001 Magnetic Tool 116-009793-001 Electronics Module 116-010253-001 250 ohm Terminating Resistor Kit 116-101197-001* Stop Plug, 3/4 NPT, AL 116-101197-004* Stop Plug, 3/4 NPT, SS 116-101197-005 Stop Plug, M25, AL, IP66 116-101197-003 Stop Plug, M25, SS, IP66 116-010816-001 Stop Plug, 20PK, 3/4 NPT, AL, EX D 116-010817-001 Stop Plug, 20PK, 3/4 NPT, SS, EX D 116-010818-001 Stop Plug, 20PK, M25, AL, IP66, EXDE 116-010819-001 Stop Plug, 20PK, M25, SS, IP66, EXDE 116-102804-001 Reducer, M25 to M20, AL 116-102804-003 Reducer, M25 to M20, SS 116-103922-001 475 Field Communicator 116-005003-001 Lubriplate grease, 1 oz. * NEMA 4/IP66 rating requires addition of non hardening thread sealant or Teflon tape. ASSISTANCE For assistance in ordering a system to meet the needs of a specific application, contact: Autronica Fire and Security P.O.Box 5620 NO-7483 Trondheim Tel: +47 90 90 55 00 Fax: +47 73 58 25 01 Web site: www.autronicafire.com E-mail: info@autronicafire.no AV20 MODEL MATRIX MODEL AV20 DESCRIPTION Universal Display Unit TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 5M 5 PORT, METRIC M25 5N 5 PORT, 3/4" NPT TYPE OUTPUTS 26 Pass-Through 4-20 ma, HART TYPE APPROVAL W FM/CSA/ATEX/CE/IECEx TYPE CLASSIFICATION (Div/Zone) 2 Ex d (Flameproof) Page 10

APPENDIX HART COMMUNICATION MENU STRUCTURE - AV20 WITH GT3000 This section displays the menu trees for the AV20 connected to the GT3000. The menu tree shows the primary commands and options available when using menu selections. Page A-1

MAIN MENU PROCESS VARS DISPLAY STATUS DEVICE STATUS DEVICE SETUP DEVICE CAL DEVICE TEST PROCESS VARS GAS NAME XXXX GAS VALUE X.XX ANALOG INPUT XX.XX MA URV X.XX LRV X.XX FAULT Y/N DISPLAY STATUS DISPLAY INFO FAULT/STATUS DEBUG MENU DEVICE STATUS GENERAL INFO FAULT/STATUS TX INFO SENSOR INFO HISTORY DEBUG MENU DEVICE SETUP HART OPTION RTC WRITE PROTECT INPUT LOOP CAL CONTRAST CONTROL DEVICE CAL CAL GAS CONC XX.XX CALIBRATION CHANGE SNSR TYPE DEVICE TEST SELF TEST RESPONSE TEST LOOP TEST D/A TRIM DISPLAY INFO F/W REV XX.XX SERIAL NUMBER XXXX TEMPERATURE XX.XX C FACTORY CONFIG FAULT/STATUS OP MODE XXXXX FAULT Y/N STATUS Y/N DEBUG MENU HART ERRORS XXXXX LCD TEST ANALOG INPUT XX.XX MA HART OPTION TAG XXXXX DESCRIPTOR XXXXX DATE DD/MMM/YYYY MESSAGE XXXXX FINAL ASSY NUM XXXX RTC SECONDS XX MINUTES XX HOURS XX DAY XX MONTH XX YEAR XX WRITE PROTECT CHANGE STATE CHANGE PASSWORD WRITE PROTECT XXXXX CALIBRATION EXECUTE ABORT LOOP TEST SET 4-20 MA D/A TRIM ZERO TRIM GAIN TRIM FAULT ADC FAULT ON/OFF FLASH FAULT ON/OFF RAM FAULT ON/OFF WDT FAULT ON/OFF 3V FAULT ON/OFF INPUT LOOP FAULT ON/OFF STATUS ANY FAULT ON/OFF CAL ACTIVE ON/OFF WARM UP ON/OFF INPUT HART ON/OFF SET 4-20 MA 3.5 MA 4 MA 6 MA 8 MA 10 MA 12 MA 14 MA 16 MA 18 MA 20 MA GENERAL INFO MANUFACTURER MODEL FGP_TX TAG XXXXX DESCRIPTOR XXXXX DATE DD/MMM/YYYY MESSAGE XXXXX FINAL ASSY NUM XXXXX DEVICE ID XXXXX FAULT/STATUS OP MODE XXXXX CAL STATE XXXXX TX STATUS Y/N TX FAULT Y/N SENSOR STATUS Y/N SENSOR FAULT Y/N TX INFO RTC H/W REV XX.XX F/W REV XX.XX SERIAL NUMBER XXXXX UNIVERSAL REV XXXXX FLD DEV REV XXXXX RUNNING HOURS XXXXX TEMPERATURE XX.XX C SENSOR INFO SENSITIVITY XXX.XX GAS TYPE XXXXX H/W REV XX.XX F/W REV XX.XX SERIAL NUMBER XXXXX REV XXXXX USL XX.XX LSL XX.XX RUNNING HOURS XXXXX CAL POINT ZERO XX.XX CAL POINT SPAN XX.XX PPM HOURS XXXXX TEMPERATURE XX.XX C HISTORY TX HISTORY SENSOR HISTORY CALIBRATION LOG EVENT LOG DEBUG MENU MODBUS ERRORSXXXX RTC SECONDS XX MINUTES XX HOURS XX DAY XX MONTH XX YEAR XX TX HISTORY RUNNING HOURS XXXXX MAX TEMP XX.XX C MAX TEMP TIME XXXXX MIN TEMP XX.XX C MIN TEMP TIME XXXXX SENSOR HISTORY RUNNING HOURS XXXX MAX TEMP XX.XX C MAX TEMP TIME XXXXX MIN TEMP XX.XX C MIN TEMP TIME XXXXX CALIBRATION LOG CAL ID XXX DATE DD/MMM/YYYY TIME HH:MM:SS ZERO XX.XX SPAN XX.XX EVENT LOG EVENT XXXXX DATE DD/MMM/YYYY TIME HH:MM:SS TX STATUS TX FAULT ON/OFF WARM UP ON/OFF CHANGE CONFIG ON/OFF MULTI DROP ON/OFF WRITE PROTECT ON/OFF SELF TEST ON/OFF RESPONSE TEST ON/OFF CURRENT FIXED ON/OFF LOOP TEST ON/OFF FACTORY MODE ON/OFF SNSR ASSY REMOVE ON/OFF TX FAULT EE FAULT ON/OFF ADC FAULT ON/OFF DAC FAULT ON/OFF LOW VOLTAGE ON/OFF FLASH CRC FAULT ON/OFF RAM FAULT ON/OFF TEMP FAULT ON/OFF SOFTWARE FAULT ON/OFF EE SAFETY FAULT ON/OFF ZERO DRIFT FAULT ON/OFF SENSOR MISMATCH ON/OFF SENSOR FAULT ON/OFF SENSOR STATUS SENSOR FAULT ON/OFF WARM UP ON/OFF CAL ACTIVE ON/OFF CAL SWITCH ON/OFF WRITE PROTECT ON/OFF EOL SENSOR ON/OFF CHANGE CONFIG ON/OFF GEN ACTIVE ON/OFF GEN INSTALLED ON/OFF SENSOR FAULT CAL FAULT ON/OFF EE FAULT ON/OFF ADC FAULT ON/OFF ADC CNTR FAULT ON/OFF 3V FAULT ON/OFF ZERO DRIFT FAULT ON/OFF FLASH CRC FAULT ON/OFF RAM FAULT ON/OFF TEMP FAULT ON/OFF COMM FAULT ON/OFF GEN FAULT ON/OFF Page A-2

Haakon VIIs gt. 4, NO-7041 Trondheim, Norway Tel: +47 90 90 55 00 Fax: +47 73 58 25 01 E-mail: info@autronicafire.no www.autronicafire.com