HE220, HE260 Humidifier Installation Kit

Similar documents
HE360 Humidifier Installation Kit

HE120, HE160 Humidifier Installation Kit

HE420A Steam Power Humidifier

HE225A,B and HE265A,B Bypass Flow-Through Humidifier

HE360 Powered Flow-Through Humidifier

HE360A,B Powered Flow-Through Humidifier

Installation Instructions

Installation Instructions Owner s Manual

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

HE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE

RECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS

HE365A,B Powered Flow-Through Humidifier

FLOW-THROUGH FURNACE HUMIDIFIER

DS 2001 REVISED Humidifier Assembly and Instruction Manual

CUSTOMER SERVICE. Toll-free:

HE365A,B Powered Flow-Through Humidifier with

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

F150E Media Air Cleaner

Duct Mount Atomizing Humidifier

L A signature series TA T N E RE O, A L L A T S IN

Installation Instructions. SPANISH Installation Instructions. FRENCH Installation Instructions

Installation Instructions

SAVE THESE INSTRUCTIONS

F200E Charged-Media Air Cleaner

FLOW-THROUGH FURNACE HUMIDIFIER

Installation. Leveling

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

MODEL HUM HUMIDIFIERS

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

HUMIDIFIERS OWNERS MANUAL A GUIDE TO OPERATING AND MAINTAINING YOUR HUMIDIFIER 49FH, 49FP, 49BF, 49WS, & 49BG

INSTALLATION. Glass Panel Doors (select models) CAUTION

Installing the Turbo Floor Model System

Dishwasher. Installation manual DW60M9990AP

T4398A,B Precision Electric Heating Thermostat

Installation Electric Dryers Instructions 01

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

FIREPLACE INSTALLATION

Read and Save These Instructions

The T6140A,B Remote Bulb Temperature Controller

F25F Media Air Cleaner

Installation Instructions

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

DRAIN WATER TEMPERING INSTALL

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

Continue to next pages for Template instructions, Owners Guide, Humidistat Instructions.

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Wiring Instructions. High-Capacity Steam Humidifiers

Installation Instructions

Installation Instructions

THE MONTICELLO CEILING FAN INSTALLATION INSTRUCTIONS

HE365A,B Powered Flow-ThroughHumidifier with

3/4 HP Model Trimmer Operating Instructions

C7031D,G,J C7041B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors

Zoning System Design Manual

CEILING FAN OWNER'S MANUAL

ComfortSTEAM TM. Humidification System

Duct Mounted Atomizing Humidifier. Table of Contents

KD-27A SERIES DISHWASHERS

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL

INSTALLATION INSTRUCTIONS

CEILING FAN OWNER'S MANUAL

RXIH-AB12A and RXIH-AB17A By-Pass Flow-Through Humidifiers

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

Hanson LED C e i l i n g F a n

INSTALLATION & OPERATING INSTRUCTIONS

Installation Instructions

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

INSTALLATION INSTRUCTIONS

UV100E Ultraviolet Air Treatment System

CEILING FAN OWNER'S MANUAL

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

INSTANT HOT WATER DISPENSER

Installation Instructions

FOR PRODUCT/WARRANTY REGISTRATION Go to Click on SUPPORT at the top of homepage Click on PRODUCT REGISTRATION

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

READ AND SAVE THESE INSTRUCTIONS HUMIDIFIERS USER S INFORMATION GUIDE. For Models *HUMD200ABM00B *HUMD300ABA00B *HUMD500APA00B

Summer Breeze Heater Service Manual

Installation Instructions

Installation Instructions EFS Hand Washing Station

ELSTON 52 CEILING FAN

PWC 1800 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model PWC P/N man Copyright 2011 Vertex Water Products

T834C Heating-Cooling Thermostat

Instant Hot Water Dispenser Owner s Manual

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

CEILING FAN OWNER'S MANUAL

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

General System Layout Sketch

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

TOUCHDOWN 48 CEILING FAN

ELECTRIC DRYER INSTALLATION INSTRUCTIONS

Installation Instructions

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

Transcription:

HE220, HE260 Humidifier Installation Kit WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that your scratchy throat and irritated nasal passages that aggravate allergies and asthma are steadily improving. You have also taken the first step in reducing the zapping you create when you walk on your carpet and then touch your TV, computer, metal door knob or your pet. Your furniture and woodwork are also benefitting from the difference that humidified air makes. Congratulations! You have just made a great investment in improving the comfort of your home. APPLICATION This installation kit contains all the parts necessary to install your new Honeywell HE220 or HE260 Humidifier. INSTALLATION INSTRUCTIONS INSTALLATION Preparing for the Installation Be sure to identify all the required (Table 1) accessories (included) and make sure the appropriate tools are available before beginning the installation. Required Accessories (Included) Table 1. Required Accessories. Quantity Accessory Humidifier Parts and Accessories 3 ft (0.93 m) Bypass ducting including: 6 in. (155 mm) diameter flexible duct Starter collar Summer shut-off damper Duct tape 20 ft (6.2m) 20 ft (6.2m) 10 ft (3.1m) 18 gauge, two-strand thermostat wire 1/4 in. (6.35 mm) OD feed water tubing 1/2 in (12.7 mm) ID drain tubing 1 bag Connecting and mounting hardware: Wire nuts (4) No. 8 sheet metal screws (18) Drain tube clamps (2 sizes) Feed tube mounting clamps (6) Brass inserts (2) Plastic compression rings (2) 1 Plug-in transformer 69-2518-03

Table 1. Required Accessories. Quantity Accessory HUMIDIFIER Air Pressure Switch and Accessories 2 Black rubber gasket BYPASS COLLAR HORIZONTAL M27302 2 Tubing Fitting Elbow HIGHBOY 1 10 ft. Tubing, 1/4 in. ID 1 Air Pressure Switch (Fig. 10) M27323 LOWBOY DOWN FLO 2 Screws, #8 x 3/4 in. sheet metal 2 Terminal Adaptor Required Tools Tools required for installation include: Tin snip. Screwdriver. Adjustable or open-end wrench. Drill, punch or awl. Level. 3/4-in. Sheet Metal Drill Bit Determining Best Location for Humidifier Select a location for the humidifier on the supply (warm air stream) or the return plenum. See Fig. 1. Select a location for the bypass on the opposite plenum. The sidewalls of the humidifier are interchangeable to allow bypass duct mounting on either side of the humidifier. Select a location that cannot damage the air conditioner A-coil during installation. Select a location where the 6 ft (1.86m) of 6 in. (155 mm) duct provided is adequate to connect the humidifier to the bypass. Do not locate the humidifier or bypass on a furnace body. Allow adequate clearance in front of and above the humidifier so you can easily remove the cover to perform routine maintenance. Mount humidifier at least 3 in. (78 mm) above the furnace body to allow adequate space for the solenoid valve and drain line. Mount humidifier in a conditioned space to prevent freezing. M12248D Fig. 1. Typical humidifier installation locations. Selecting Water Supply Location Use either hard or soft water in the humidifier and either hot or cold water. The water flow rate, with the humidifier running, is 3.5 gal/hr (13 liters/hr) to flush the pad and provide moisture for evaporation. Make sure that the 20 ft (6.2m) of feed water tubing provided is adequate to connect the water supply (saddle valve) with the humidifier solenoid valve. Locating Closest Floor Drain Select location with access to a floor drain to provide drainage for air conditioner condensation and humidifier drainage. If you do not have a drain available, we recommend that you install the Honeywell Whole House Drum or Disk Humidifier. Make sure that the 10 ft (3.1m) of drain tubing is adequate to reach from the humidifier drain connection to the floor drain. Mount the switch at least 6 in. (152 mm) upstream from an elbow or junction, and at least 15 in. (381 mm) downstream from an elbow or junction. Locate the switch on the opposite side of the duct from the air entrance. (See Fig. 1-3 in S688 Installation Instructions.) Selecting Location for Humidistat Select a location for the humidistat on the return plenum or on the wall in the living space. Mounting on the return plenum is the easiest installation for the control wiring circuit. For return duct mounting, the humidistat should be mounted upstream from the humidifier or bypass so that it is properly sensing the relative humidity of the living space. Locate the control at least 8 in. (203 mm) upstream from the humidifier in the return air duct. (See Fig 2.) 69-2518 03 2

RETURN AIR ALTERNATE LOCATION RETURN AIR WATER FEED NOZZLE HUMIDIFIER PAD ASSEMBLY FRAME 6 in. (152 mm) MINIMUM BEST LOCATION 15 in. (381 mm) MINIMUM COVER HUMIDIFIER HOUSING WATER FEED TUBE RETURN AIR DUCT M12831 SIDEWALL Fig. 2. Selecting duct location for humidistat. Locating Closest 120V Electrical Outlet Select location with access to an outlet. If not available, contact an electrician to have one installed. Make sure that the 20 ft (6.2m) of thermostat wire is adequate to reach from the humidifier solenoid, to the sail switch, to the humidistat, to the plug-in transformer in the outlet. INSTALLING HUMIDIFIER BY-PASS SIDEWALL Fig. 3. Disassembling humidifier. M12304A WARNING Hazardous Voltage. Can cause personal injury or equipment damage. Do not cut or drill into any air conditioning or electrical accessory. 7. Make sure the humidifier housing is level, then position it in the opening so the plastic tabs are in place on the lower sheet metal edge of the opening. Use pliers, as necessary, to flatten cut edges. See Fig. 4. 8. Secure the humidifier housing to the opening at the top and bottom using sheet metal screws. CAUTION Sharp Edges Installation Hazard. Can cause personal injury. Wear gloves and safety glasses. SHEET METAL SCREWS (4) LEVEL DUCT 1. Turn off power to the air handing system at the circuit breaker. 2. Draw a level line on the plenum in the location chosen for the humidifier. (Leveling assures optimal humidifier performance.) 3. Locate the template in the Humidifier Installation Instructions. 4. Tape the template in position and trace around the template. 5. Remove the template and carefully cut the rectangular opening. 6. Disassemble the humidifier; remove the cover and take out the humidifier pad assembly. See Fig. 3. OPENING TO AIR DUCT NOTE: Sidewalls are interchangeable for either left or right bypass installation. To change direction, remove the screws holding each sidewall, reverse sidewall locations, and reinstall the screws. PLASTIC TABS (2) DRAIN TUBING M20171 Fig. 4. Installing humidifier on duct. 9. Use the 6 in. (155 mm) starter collar as a template to mark the opening for the bypass. 10. Carefully cut the opening for a 6 in.(155 mm) starter collar. See Fig. 5. Use a drill, punch or awl to start the cut in the middle of the circle. Cut in an outward spiral to assist in controlling the cut. 3 69-2518 03

STARTING HOLE 6 IN. ROUND TEMPLATE M20174 Fig. 7. Connecting bypass ducting. Fig. 5. Cutting bypass opening. M20172 11. Assemble the summer shutoff damper into the starter collar. Verify that the damper rotates freely between the open and closed positions. Make sure handle will be accessible. Mark the damper closed position as summer and the open position as winter. See Fig. 6. To avoid sagging and stress on humidifier, add support if ducting is longer than 4 ft (1.25m). 14. Seal the duct connections with duct tape. 15. Reinstall the humidifier pad assembly in the humidifier housing. Be sure to reconnect the water feed tube and ensure that the tube is not pinched or kinked. 16. Hinge the cover in place and secure with the thumbscrew located at the bottom of the cover. SUMMER WINTER Connecting the Plumbing 1. Shut off the water. CAUTION Chemical Hazard. Can cause personal injury or equipment damage. Do not use any line connected to an air conditioner. Do not use gas line. M20173 Fig. 6. Installing the starter collar. 12. Remove liner to expose foam adhesive. Position starter collar over opening. 13. Using sheet metal screws, connect starter collar to the duct and bypass duct from humidifier to starter collar. Be sure to secure the collar to the duct with sheet metal screws. See Fig. 7. 2. First, connect 1/4-in. line to the humidifier s solenoid valve, located at the bottom of the humidifier. a. Remove the compression nut. b. Discard the brass ring, replacing it with the plastic ring. c. Install the brass insert into the end of the tubing. d. Insert the tubing into the solenoid valve fitting and support the valve while tightening the compression nut. NOTE: Do not over-tighten the compression nut. Moderate tightness prevents leaking. 3. Use the saddle valve (included) to tap into the water supply line at the location selected. See Fig. 8. If tapping into galvanized pipe, drain line and pre-drill 3/17-in. tap for saddle valve. NOTE: The saddle valve is not designed to regulate water flow. The valve is either open or closed. 69-2518 03 4

To prevent debris from clogging the solenoid inline filter, be sure to install the saddle valve handle pointing toward the ceiling. BRASS COMPRESSION NUT PLASTIC COMPRESSION RING BRASS INSERT M20176 M27300 Fig. 8. Installing feed tubing. 4. Use 1/4-in. (6mm) OD tubing and connect the saddle valve to the inlet side of the solenoid valve on the humidifier (See Fig. 9). 5. Repeat step 2, a - d for saddle valve fitting. Fig. 10. Pressure switch oriented vertically. 3. The return duct is recommended, however the switch can also be mounted to the supply duct. NOTE: Cut tubing to correct length so the tubing terminates at the drain. A B M20177 Fig. 9. Installing the drain tubing. Air Pressure Switch Installation Do not install the switch in an area where temperature exceeds rating of -40F to 190F (-40C to 88C) 1. Disconnect power from the humidifier before installing. 2. Mount the switch vertically with pressure connectors facing down, using provided self-tapping screws to secure the switch to the duct. Calibration accuracy requires that the switch be mounted vertically (as pictured in Fig. 10). SUPPLY DUCT INSTALL - AIR LINE ONLY TO TAP A, CONNECTED TO THE + PORT ON THE AIR FLOW SWITCH RETURN DUCT INSTALL - AIR LINE ONLY TO TAP B, CONNECTED TO THE PORT ON THE AIR FLOW SWITCH SUPPLY/RETURN DUCT INSTALL - AIR LINE CONNECTED TO BOTH THE + AND PORTS ON THE AIR FLOW SWITCH M27303 Fig. 11. Mounting the pressure switch. 4. Cut a 3/4-in. diameter hole in the duct within 10 feet of the switch to ensure the provided tubing reaches the pressure tap elbow. 5. Insert the black rubber gasket into the duct hole. 6. Connect the tubing to the tubing fitting elbow and insert the tubing fitting elbow into the black rubber gasket. 7. Connect the other end of the tubing to the applicable pressure connection on the switch. e. Black connection if installed on the supply f. Grey connection if installed on the return g. Both grey and black if installed on both 5 69-2518 03

Humidity Control Régulateur d'humidité OUTDOOR TEMPERATURE -20 F -30 C -10 F -25 C 0 F -20 C +10 F -10 C +20 F -5 C Over 20 F Over 0 C HUMIDITY SETTING 15% 20% 25% 30% 35% 40% HE220, HE260 HUMIDIFIER INSTALLATION KIT With low-speed airflow or variable speed systems it is recommended to run tubing to both the supply and return ducts. INSIDE OF DUCT 1 CONNECT TUBING TO + CONNECTION IF PRESSURE TAP IS MOUNTED TO SUPPLY DUCT. CONNECT TO IF PRESSURE TAP IS MOUNTED TO RETURN DUCT. M27304 1 WIRING CAUTION Hazardous Voltage. Can cause personal injury or equipment damage. Disconnect power supply before installing or servicing equipment. All wiring must comply with applicable local code, ordinances and regulations. Wire the humidifier solenoid valve, pressure switch, humidistat and transformer.see Fig. 15 Fig. 12. Install tubing. You may cut the tubing to fit the connection length between the tubing fitting elbow and switch. It is also recommended to secure the hose to existing structures to avoid accidental disconnection. TRANSFORMER HUMIDISTAT INSTALLING HUMIDISTAT HUMIDIFIER SOLENOID VALVE AIR PRESSURE SWITCH Mounting Duct 1. Apply the template to the duct location chosen for the humidistat. Make sure the template is level before drilling the holes. 2. Refer to the template (provided with the H8909 Humidistat Installation Instructions) to drill the control assembly opening and mounting holes for the H8908. 3. Remove the H8908 case from the base. 4. Position the foam gasket on the H8908 base. 5. Position the base on the duct with the arrow up. 6. Secure the base to the duct using the four 1 in. (25 mm) mounting screws provided with humidistat. 7. Connect the low-voltage wires to the leads and replace the H8908 case. See Fig. 14. NOTE: For wall mounting instructions, see the H8908 Installation Instructions. NORMALLY OPEN (NO) TERMINAL 1/4 (6) X 1/32 (1) THICK QUICK CONNECT WIRE TO HVAC C TERMINAL Fig. 14. Wiring the controls. ATTACH ADAPTOR 1 2 3 C 1 2 3 2 3 NO NC ATTACH ADAPTER WIRE TO HUMIDIFIER C TERMINAL + PI ASSEMBLED IN MEXICO COMMON (C) TERMINAL 1/4 (6) X 1/32 (1) THICK QUICK CONNECT M27398A M28974 HUMIDISTAT BASE REAR OF HUMIDISTAT Fig. 15. Close-up of pressure switch wiring. 1. Run the two-strand thermostat wire from the humidifier to the transformer, from the transformer to the humidistat, and from the humidistat to the pressure switch. 2. Cut lengths of thermostat wire to reach between components, leaving adequate wire at both ends for connections. WIRE SLOT HUMIDISTAT WIRES M20179 Fig. 13. Humidistat base and rear view. NOTE: Transformer, humidistat and pressure switch can be wired in any order. 3. At the humidifier, connect the black and white conductors to the two black humidifier wires. 4. At the transformer, connect both black conductors to the two transformer terminals. Use a wire nut to connect together the two white conductors. 69-2518 03 6

5. At the humidistat, connect both black conductors to the two humidistat terminals. Use a wire nut to connect together the two white conductors. TESTING HUMIDIFIER OPERATION Checklist Humidifier is level. Starter collar is secured with sheet metal screws. Summer shut-off damper is open (in winter position). Control wiring was reviewed using circuit diagram. Transformer is plugged in. Feed line has no kinks. Drain line slopes continuously down and ends at floor drain. Water hose inside humidifier is connected to PerfectFlow water distribution tray. After installation use the following steps to check the humidifier operation: 1. Turn on the power and the water supply 2. Turn the H8908 Humidity Control to On and turn on the heat by setting the thermostat to 10ºF (6ºC) above room temperature. The furnace blower must be on in to activate the humidifier. 3. Make sure that water is flowing out of the drain hose. If water does not flow, see Troubleshooting Your Humidifier section. 4. Check for leaks. 5. Reset the thermostat and H8908 Humidity Control to a comfortable setting for automatic operation. 7 69-2518 03

TROUBLESHOOTING YOUR HUMIDIFIER (TABLE 2) Table 2. Troubleshooting Humidifier. Problem What to look for What to do Water leakage Leaking joints Shut off water. Tighten connections. Brass tubing inserts Saddle valve leaking Verify that brass tubing inserts are used. Verify rubber pad is installed on saddle valve. No water to drain. Electrical Verify control circuit wiring. Check all connections. Humidistat Transformer Solenoid Plumbing Saddle valve Humidifier Drain tubing Turn humidistat up and down and listen for contact to click. Verify that outlet has power. After verifying other wiring components, turn on furnace fan, turn humidistat up and down, and listen for solenoid to click. Verify plumbing connections. Check for kinks. Verify that needle pierced water line and then back out needle to open valve. Remove cover and verify that water flows into distribution tray. Verify no obstructions. Air leakage Check duct joints Seal with duct tape. Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Toronto, Ontario M1V 4Z9 customer.honeywell.com U.S. Registered Trademark 2010 Honeywell International Inc. 69-2518 03 M.S. Rev. 11-10 Printed in U.S.A.