USA CDN. SANIMARIN Macerator Toilet Owner s Manual SANIMARIN 31C SANIMARIN 35 SANIMARIN 48

Similar documents
Sanipack is a compact pump/macerator specially designed to take the waste from a wall hung or back to wall WC pan.

Please also see 10 golden rules for correct Saniflo installation on

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

TECHNICAL INFORMATION T 15xx Dryers

TECHNICAL INFORMATION T1500 Series Clothes Dryers

Instruction Manual for Electric Marine Toilets LT-0E and LT-1E

WATERGENIE. Install a Toilet or Bathroom anywhere you like Installation and Maintenance Instructions

INSTALLATION AND CARE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

WARNING , IMPORTANT NOTICE Dometic sanitation systems must be installed according to Dometic s recommended procedures.

TECHNICAL INFORMATION Touchtronic Clothes Dryers

Dishwasher. Installation manual DW60M9990AP

8700 Series MasterFlush Toilets. Macerator Toilet Operation manual. Mazerier-WC Bedienungsanleitung WC dilacérateur Mode d emploi...

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

52 STRATHMERE CEILING FAN

INSTALLATION AND CARE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

Mira Sport Max with Airboost

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

INSTALLATION INSTRUCTIONS

Water Boilers ME10EN, ME15EN. Table of Contents

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

CONDITIONS OF SALE AND WARRANTY

48 TAYLOR CEILING FAN

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

Toilet. Installation and Maintenance Instructions

52 CEILING FAN. Owner s Manual Models #50336, 50337

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

SINGLE DISHDRAWER TM DISHWASHER

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

REVIVAL LITE VITREOUS CHINA REVERSE TRAP TOILET

Lite Flush Electric Toilets

Installation. Please keep this manual for future reference.

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

PO Box 827 Hawley, MN (218) Fax (218)

Installation Instructions

Top Control Dishwasher

B.I.C.A Built-In Coffee Appliance

Removing shipping locks

WELLWORTH /HIGHLINE WITH PEACEKEEPER VITREOUS CHINA TOILET

Greenleaf 600 Macerator Toilet Waste Pump

BURWELL BIDET TOILET SEAT INSTALLATION

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

Dishwasher Installation Manual

SWIMMING POOL HEAT PUMP UNIT ECO - series. Installation & Instruction manual

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

52 SAN LUCAS CEILING FAN

DOUBLE DISHDRAWER TM DISHWASHER

Installation Instructions

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

Jabsco Marine Toilets SIMPLY RELIABLE SOLUTIONS FOR EVERY BOAT AND BUDGET

Model: Series. PumpAgents.com - buy pumps and parts online. DESIGNER STYLED MARINE TOILET With Integral Bowl Rinse Water/Waste Evacuation Pump

Technical data. Bathroom/shower room installations. Water services (WRAS approved)

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

52 BERKSHIRE CEILING FAN

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Dishwasher Installation Instructions DW 24XT/DW 24XV

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, SQUATTING TOILET. To main vacuum line, connection Ø50.

WC2 & WC3 Installation & Maintenance Instructions

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

52 BARSTOW CEILING FAN

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Owner s Manual WARNING! Congratulations

FRANKE MINERVA 3-IN-1 HOT WATER TAP HEATING TANK INSTALLATION GUIDE

If you have any problems with this product, please call BEFORE returning it to your retailer.

Viking Installation Guide

Moisture inside the drum is due to final testing.

Elegance. Marine. Toilet. Installation and Maintenance Instructions. Manufactured after August 2016

Moisture inside the drum is due to final testing.

EEMAX HOME ADVANTAGE

COUTURE ECO-LITE VITREOUS CHINA REVERSE TRAP TOILETS

DH 100 P. Always Dry dehumidifier. with. Condensation Removal System

Installation Instructions

Installation Instructions

Pre-Installation Instructions. Installation Instruction. Installation Instructions. kah. wall. Warning. User s Manual and warranty

Torrena 42 Ceiling Fan

CFS-2000 CHILLER TM. Operating Instructions P/N (110 VAC) P/N (230 VAC)

Some models are supplied with a protective film on steel and aluminium parts. This film must be removed before installing/using the appliance.

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Operating Instructions

Camarillo 52 Ceiling Fan

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

20-GALLON MOBILE PARTS WASHER OWNER S MANUAL

Model Series ELECTRIC WATER SYSTEM PUMP. PumpAgents.com - buy pumps and parts online. Model Series. Automatic Multi-Outlet FEATURES

Vacuum toilet system Instruction manual. Series. Series and Series. VacuFlush

Automatic Water System Pump SERIES

Owner's Manual. Please read this document carefully before installing and/or using your vacuum cleaning system.

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization

DOUBLE DISHDRAWER TM DISHWASHER

Transcription:

297 1 01.10 IND1-01 SANIMARIN Macerator Toilet Owner s Manual CDN USA U.S. - 105 Newfield Avenue, Suite B, Edison, NJ 08837 Toll Free: 1-800-363-5874 INSTALLATION INSTRUCTIONS The user should retain these instructions for future reference SANIMARIN 31C SANIMARIN 35 SANIMARIN 48 www.sanimarin.com Canada - 1-685 Speedvale Avenue West, Guelph, ON N1K 1E6 Toll Free: 1-800-571-8191

2 L L (31 C) W R Q Q D x 3 A B Ø 32/50 G E F U 3 SANIMARIN 31C SANIMARIN 35 SANIMARIN 48 17 14 1/2 1 1/2 14 1/2 17 1/4 14 1/2 510 mm 12 1/4 18 1/4 18 1/2 9 3/4 9 1/2 12 1/2 11 3/4 15 3/4 11 3/4 310 mm 18 1/4 8 1/2 5 SANIMARIN 31 C SANIMARIN 35 SANIMARIN 48 12 V SANIMARIN 31 C SANIMARIN 35 SANIMARIN 48 24 V 9,8 9,8 6,5 6,5 Vertical Height (ft) 3,28 0 0 2,6 5,3 7,9 10,5 13,2 15,8 18,5 21 23,7 Flow Rate (Gal/mn) Vertical Height (ft) 3,28 0 0 2,6 5,3 7,9 10,5 13,2 15,8 18,5 21 23,7 26 Flow Rate (Gal/mn)

6 6a a m m 25 1 b m m 15 59 0. c d B G A + + F E 6b D x2 U Q 1 6c 8742 N 297 SANIMARIN USA 210x280.indd 3 D L 1/02/10 17:01:22

6 SUITE 6c (31 C) STICKER: + BATTERY 3 WHITE 2 1 6d a R WHITE WC BLACK BATTERY b c 6d (31 C) a POSITIVE SEA WATER PUMP (option) SWITCH WHITE VALVE (white) WC + MOTOR (red) - MOTOR (black) VALVE (white) - BATTERY 8742 N 297 SANIMARIN USA 210x280.indd 4 + BATTERY 1/02/10 17:01:26

6 SUITE 6g A B A Control Panel l B Electronic box Electronic connections 1 Keyboard 2 Tank level indicator 3 Battery 4 Motor: red positive, black negative 5 Solenoid valve: white 6 Optional pump 7 SANIMARIN 31 C SANIMARIN 35 SANIMARIN 48 SANIFLO A Group SFA Company 12 V = 260 W - 24 V = 260 W

1 GENERAL SANIMARIN is a WC equipped with a pump/macerator which installed and used correctly will give reliable and consistent service for many years. SANIMARIN is for marine or mobil unit use. Please follow these installation instructions, paying attention to the following warnings; Possible danger to personnel, Warning of possible electrical hazard, «WARNING» Possible danger of damage to the macerator. APPLICATION SN 35 C & SN 48 SANIMARIN uses an electronic keyboard L which operates as follows; STANDARD Operation: press the NORMAL pad on the control console. Cycle time 19 secs. Water consumption: 2.2 lit / 0.58 gallons. ECO Cycle: press the ECO pad on the control console. Cycle time 10 secs. Water consumption: 1.2 lit / 0.31 gallons. DRAINING Cycle: press continuously the EMPTY pad on the control console. Adjustment of the cycle of rinsing The rinsing time during the Normal cycle can be programmed, to add up to a further 5 seconds. The cycle time thus varies between 19 seconds and 24 seconds, and water consumption varies between 2.2 l / 0.58 gal and 3 l / 0.79 gal. To enter the programming mode: press the Normal and Eco keys at the same time for at least 5 seconds. The red LED flashes for 5 seconds and then goes out. To increase rinsing time by 1 second: press the Normal key = 1 beep (press 5 times at most). To reduce rinsing time by 1 second: press the Eco key = 1 beep. To exit the programming mode automatically: no keys pressed for 5 seconds = the green LED comes on. The water consumption programmed remains in the memory even after the unit has been disconnected from the power supply. Management of the black water holding tank LEDs and Buzzer: Depend on the status of the Holding Tank high level switch (optional connection to the electronic box R). Normal level: Green LED on, red LED off. Buzzer silent and all cycles authorized. High level reached: Green LED off, red LED flashing = Full message visible, + Beeps when a key is pressed. 3 further cycles allowed. Pressing Normal for 5 seconds will return cycles to normal operation. APPLICATION SN 31 C SN 31 C is commanded by a two-position switch: Add water: bowl flushing command Pump out: maceration and discharge command Use: 1/ FLUSH: (Add Water) recommended water level: halfway up the bowl 2/ DISCHARGE: (Pump out) 3/ FLUSH: (Add Water) to fill the bottom of the bowl with water Note 1: In rough seas, empty the bowl (using the pump out position) to avoid spillage Note 2: No automatic cycle 3 DIMENSIONS (see drawing n 3 page 2) 4 TECHNICAL DATA Applications 6 INSTALLATION GUIDE 6a FIXING BOWL TO THE FLOOR discharge of a WC Max. vertical evacuation 3 m / 9.8 ft Max. horizontal evacuation 30 m / 98 ft Nominal power 260 W in 12 V version 260 W in 24 V version Electrical class III Isolation level IPX4 Net weight SN 31 C 16,4 Kg / 36.2 Ibs SN 35 22,2 Kg / 48.9 Ibs SN 48 23,8 Kg / 52.5 Ibs CAUTION : This product should not be used for any other purpose other than that described here. The minimum discharge pipe inner diameter should be 25 mm / 1 inch. 5 PERFORMANCE CURVE (see drawing n 5 page 2) a Draw the outline of the base on the floor, in the area around the fixing holes in the ceramic bowl. b Measure 15 mm / 0.59 inch from the outline drawn, position the brackets A and drill through the middle of the holes. c Screw the brackets in place, leaving them loose, they will be tightened once the bowl has been fitted. d Fit the bowl. Note: wait until all the connections have been made before fixing the bowl definitively in place. Note: on the SANIMARIN 35, there is only one bracket, in the front. The two screws at the back are placed vertically. 6b CONNECTING THE WASTE PIPE AND THE WATER SUPPLY PIPE Connect the 38/38 mm / 1 1/2 diameter bend Q or the 38/25 mm / 1 inch diameter bend Q to the check valve U and the waste pipe, and then fix in place with clip D. (through-the-wall, SN35) (trough-the-floor, SN48 & SN31C) 1 Water supply pipe. To be connected to a seawater pump (supplied as an option), or to the pressurized onboard freshwater system. The pressure in the system must be at least 1.7 bar (flowrate 2.5gpm/ 9.5 gpm). Safety: To ensure that your installation is safe under all heeling conditions, put a loop in the feeder and waste pipes, with a high point 50 cm / 19.6 inchabove the waterline. Fit a ventilation valve at the high point of each loop. Note: it is possible to fit a seawater pump other than the pump supplied as an option, provided that the current requirement is not more than 16 A (In that case you must insert a 12 or 24 VDC electrical relay). Raw water pump must not be demand type. Pump is controled by signal from control module or rocker switch for SN31C. 6c FITTING THE CONTROL TOUCHPAD (SN35 & SN48) The touchpad L must be fitted in a position where it does not interfere with use of the seat and cover, and it must not be placed more than 1.50 m / 59 inch from the electrical control box R. Cut out a rectangle measuring 80x50 mm / 3.15x1.96 inchfrom the bulkhead. Fix the keyboard in a horizontal position and clip the frame into place.

6c 31C FITTING THE ROCKER SWITCH AND PUSHBUTTON (SN31C) Panel cut-out: rectangle 40 mm 5 mm. Fitting the switch: Cut out a rectangle in the bulkhead, to the measurements shown above. Fix the holder supplied in place with screws, and then insert the switch. Wire up the switch (6d). 6d ELECTRICAL CONNECTIONS (SN35 & SN48) a - Fix the box R in a dry, protected location. b - Connect the cable from the touchpad to the box. c Insert and connect the electrical wiring from the SANIMARIN to the electrical box, see 6g drawing. Lastly, connect the electrical box to the battery, making sure that the cross-section of the wires is sufficient - 12 VDC: AWG 12 (4sq.mm) up to 9m/30ft and larger if a greater length is required. - 24 VCD: AWG 14 (2.5sq.mm) up to 9m/30ft and larger if a greater length is required. 6d 31C ELECTRICAL CONNECTIONS (SN31C) : see picture The electricity supply to the SANIMARIN must be connected directly to the boat s electrical switchboard, and it must be used solely for that equipment. It is advisable to add a 25 A fuse in a 12 Volt system, and a 15 A fuse in a 24 Volt system. Make sure the wires are connected correctly: Red wire = positive (+) terminal, black wire = negative (-) terminal 7 DISCHARGE PIPE Caution: Please check local legislation regarding discharge from on board toilets- i.e. holding tanks etc. SANIMARIN macerates and pumps at the same time. A seacock should be fitted where the SANIMARIN discharges through a skin fitting. (see drawing 7 ) 2 Caution: For units installed below the water line, the discharge pipe should rise at least 50 cm / 19.7 inch above water level and be fitted with an anti-syphon valve prior to falling and discharging through the skin fitting. SANIMARIN does not require the use of chemicals in order to operate. 8 OPERATING TEST FOR PUTTING INTO SERVICE AND SUBSEQUENT CHECKS SN35 & SN48 1 - Open the water admission valve fully to ensure a good bowl rinse. 2 - STANDARD Cycle Press pushbutton NORMAL and after approximately 9 seconds of flush cycle, the pump will start and run for approximately 6 seconds to clear the bowl and then it takes 4 seconds to reprime the bowl. 3 - Throw several sheets of toilet tissue into the bowl and repeat the cycle. The bowl should completely clear. Repeat the cycle again. 4 - ECO Cycle Press pushbutton ECO and after approximately 3 seconds of flush cycle the pump will start and complete the discharge within a further 3 seconds and then it takes 4 seconds to reprime the bowl. SN31C Connect the unit to the power supply, and turn the watersupply valve on fully to flush the unit thoroughly. Press Add water until the waterlevel is about halfway up the bowl (about 9 sec), put some pieces of toilet paper in the bowl, Pump out (about 6 sec) and then Add water (about 4 sec). Note: We recommend compliance with the time lapses shown above. 9 USAGE SANIMARIN can be used like any normal toilet and does not require any particular maintenance. Caution 1 Only the disposal of toilet papers, fecal matter, and waste water will be under guarantee. Any damage due to foreign bodies such as cotton, condoms, sanitary towels, wet wipes food, hair, or liquids such as oils, solvent products, will not be under guarantee. Caution 2 If away for a long period (holiday, ) or in the event of a long interruption of electricity, the water and electricity supplies to the SANIMARIN should be switched off. 10 SERVICE Normal non-foaming household bleaches/wc cleansers can be used with this unit. 11 WINTERING In the event of a long period without use, rinse the bowl and carry out several flushing cycles with a supply of fresh water. 12 FAULT FINDING In most cases, any inconsistencies in the operation of the unit will be minor and easy rectified. Please refer to the chart below. If the problem cannot be easily remedied thanks to this chart, please call our SANIFLO Service organisation or go to a SANIFLO-approved technician. SYMPTOM The cycle proceeds correctly, the motor turns but water in the bowl empties slowly or not at all The cycle proceeds correctly, but some water remains in the bowl after a cycle The motor rattles or crunches SN35/SN48 After the button on the control console has been pressed, the cycle does not start The cycle engages but little water runs in the bowl The cycle engages but water does not run in the bowl SN31C After pressing add water, little water enters the bowl After pressing add water, no water enters the bowlwater, no water enters the bowl Disconnect the electrical power supply, before attempting any work on the unit. PROBABLE CAUSES The evacuation is clogged The height of evacuation is too great The discharge pipe is pinched Foreign body into the bowl. Faulty programmer Faulty control console The inlet filter of the solenoid valve (18) is clogged. The water feed pipe is pinched. The stop valve is closed. The solenoid valve (18) is defective. The inlet filter of the solenoid valve (18) is clogged. The water feed pipe is pinched. The stop valve is closed. The solenoid valve (18) is defective. REMEDIES Dismount and clean the discharge pipe. Modify the installation. Check the route of the discharge pipe. Disconnect the motor supplies. Close water admission. Remove the motor unit. With a hook, withdraw all the matters being able to obstruct the rotation of macerator. With a tool, turn the turbine in the 2 directions until rotation is free. Re-connect the motor supplies and press on the pneumatic contactor to control the correct operation of unit. Open water supply. If the macerator remains blocked, we recommend to call the SFA service. Replace the control console Call an SFA service agent. Clean the filter of the solenoid valve. Check the water admission pipe. Open the stop valve. Change the solenoid valve. Clean the filter of the solenoid valve. Check the water admission pipe. Open the stop valve. Change the solenoid valve. 13 GUARANTEE 2 years guarantee from date of purchase, subject to correct installation and correct use: disposal of toilet papers and fecal matter only. Guarantee is limited to replacement or service of the defective spare parts, and any indemnity or claim for damages will not be included. Freight and packing costs, travel expenses are not included in the guarantee. It does not cover any normal deterioration of the material over time, any external deterioration or accident, incorrect disposal of sanitary products. Any modification without prior notice will not be under guarantee. Fixing, modification, or replacement of parts without our agreement will not be guaranted, and will invalidate it. Our liability is solely for the product itself. Guarantee starts from date of purchase we may request a copy of the invoice to validate the purchase date.

2 5a SANIMARIN 35 and SANIMARIN 48 for 110 V A G B C x 1 D E F 40-60 H x 1 I x 1 32-55 Hand basin J x 1 option K x 1 VERTICAL DISTANCE 12 9 6 3 0 10 12 14 16 18 25-40 Flow Rate (US gallon/mn) H 1 2 OK OK 3 D Ø 1 C I 6 SANIMARIN SFA SANIFLO CS40 / CLV50 120 V - 60 Hz - 7,2 A IP44-1 GENERAL DESCRIPTION The SANIMARIN is a water efficient toilet, it uses approximately 4 liters (1.06 gallons) of water per flush. 5 INSTALLATION 5a DISCHARGE PIPE INSTALLATION See fig. n 5a 1, 2, 3 (above). At the rear of the SANIMARIN is a rubber hose of 11/4-inch in diameter. Enclosed with the SANIMARIN is a rubber elbow I and a flapper style checkvalve assembly H. Before inserting the checkvalve into the rubber hose, know in which direction you want to run the discharge installation. When facing the toilet from the front, you may want to run the discharge pipe to either the right hand side or to the left hand side of the SANIMARIN. It is very important, that the open side of the checkvalve flapper, faces the direction of the discharge pipe. Insert flapper assembly into the pipe and push discharge elbow over it. Tighten the assembly with the provided gear clamp. 1. PVC: 1-inch solvent welded pipe. The flared end of a 1-inch coupling (or bend) fits exactly inside the rubber elbow. This pipe has a thicker wall thickness and fits therefore inside the discharge elbow. Use bends rather than elbows. Use two 45 elbows back-to-back to make up a 90 elbow. 2. Copper: 1-inch copper. 3. The flared end of a 1-inch coupling (or bend) fits exactly inside the rubber elbow. Use bends rather than elbows. 4. CPVC: 1-inch solvent weld pipe. 5. The flared end of a 1-inch coupling (or bend) fits exactly inside the rubber elbow. Use bends rather than elbows. Use two 45 elbows back-to-back to make up a 90 elbow. If you make the discharge installation with pipe smaller than 11/4-inch, start the installation by inserting a coupling or an elbow into the discharge elbow and clamp down with a gear clamp. From there use a short piece of pipe before you change directions, (up, down, rear). Do not yet connect the short piece of pipe to the discharge installation. If your installation requires a vertical discharge (and when made with 1-inch material), you may want to install a Full-Flow Ball Valve for servicing purposes and finish your discharge pipe installation. The connection to the soil-stack should be made with an approved TY fitting and should be in accordance with your local plumbing code. (Using a SADDLE CLIP may not be permitted in your area.) Because of the incorporated non-return valve, the pipe work can be installed up to 3m (9 feet) in height. (It is unadvisable to add an additional check valve.) It is possible to install the discharge pipe in either upwards or downwards direction. When discharging downwards it is necessary to run the discharge pipe horizontally for a distance of 12-inches (30cm) before changing directions. Normally, an anti-siphon valve is not necessary because the SANIMARIN automatically stops siphoning action. 5b WATER SUPPLY CONNECTION See fig. n 5c (technical data sheet). For the best possible flushing action, the SANIMARIN needs to be connected to a 1/2-inch water supply. The SANIMARIN is supplied with a supply tube. The copper end of this supply tube will fit inside the 3/8-inch compression end of a shut-off valve. Due to the international distribution of our product range, it may be possible that the tip of the supply connector is metric. Simply cut this portion off and you are left with a 3/8» connector. 5c ELECTRICAL CONNECTION The SANIMARIN should be connected to a 120 V, 60 Hz, 15 Amp. Ground Fault Circuit Interrupter, (either of the breaker or receptacle type). Connect only to receptacle protected by a ground fault circuit. Warning: risk of electric shock - this pump is suplied with a grounding conductor and grounding type attachment plug to reduce the risk of electrical shock be certain that it is connected only to a properly grounded - type receptacle. 5d COMMISSIONING THE UNIT 1. Open the stop valve completely. 2. Plug the electrical cord into the receptacle. 3. Push the air switch and hold for one second, let the unit go through its cycle, repeat. 4. Now throw some toilet paper into the bowl and press the switch again to verify the correct working of the unit and discharge pipe. In case of electrical power failure of any duration, it is necessary to close the Shut-Off valve, because leaks, no matter how small, may fill up the bowl in time and cause flooding.