LAPIS-EX. boiler scale removing device CONTENTS. Description. Component parts. Application. Accessories. Instruction for instalation

Similar documents
AQUACALK EQUIPMENT. Description of the problem:

The Electronic Anti-Scale System Condominiums and Large Buildings

INSTRUCTION MANUAL MNBX14

STORAGE WATER HEATERS

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Assembly- and User Manual Electric Infrared- Patio Heater MODEL: Geda HS - 2 kw Art. Nr. HS 10000

Cafim RFID. Electronic lock. Cafim Srl - via G. Di Vittorio, Misinto ( Monza Brianza) T:

LC2200 Level Controller Installation and Maintenance Instructions

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

WATER DESCALERS. Water Wizard Water Magic Water Heavy Duty Water Heavy Duty + OPERATION MANUAL.

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller

STS 5070SS. EN Toaster. Copyright 2017, Fast ČR, a.s.

Installation Manual. Frost Protection Cable. Warmup Ireland Web: Telephone:

EasyWire Between Joists Installation Instructions

Power. Average noise level (DIN EN ISO 4871)

MAJIK ENGLISH 11/20/02 11:30 AM Page 1 M A J I K O W N E R S M A N U A L

MONARCH SCALEOUT MONARCH WATER

PUROTAP easy. Installation Function Operation Service. fast efficient safe. Demineralised heating water perfect for every system

OPERATING INSTRUCTIONS

Bar Fridge USER MANUAL MB46W

LC3000 Level Controller Installation and Maintenance Instructions

nanoheat PAD Quick User Guide This appliance is approved, applicable to most countries in Europe and Asia but not the U.S. and Canada.

TECHNICAL SHEET. Indoor luminaire FIRA-03-1xT8 AS Didactic. About the product. FIRA AS, FIRA AS Didactic

7800 Neutralizer Installation & Start-Up Guide

EFG ENERGY OPTIMISING SYSTEMS

EN Variable Temperature Electric Kettle

HEATING SOLUTIONS WATERBED

L / -014L / -015L

DEHUMIDIFIERS & VENTILATORS

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

ST NF60188W ST NF60188STA

Designed in the UK. Rapide Ultimate. User Guide Vax Rapide Ultimate

RECOMMENDATIONS FOR INSTALLATION

for relative humidity and temperature with calibration certificates

Snifter ATEX22 VERSION. User Manual. Distributor

The Electronic Anti-Scale System For Hospitality Applications

5KW ELECTRIC FAN HEATER

Installation Instructions

ARCHITECTURAL AND BUILDING RELATED FILMS

Designed in the UK. Rapide. User Guide V-024E. Performance is everything. vax.co.uk

Venting Supplement Saf-T Vent 3" venting Special gas vent system vent and combustion air supplement for 3" diameter venting Hazard definitions

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

SUBMERSIBLE DIRTY WATER PUMP

Documentation. Glass -/quartz insulated Heating Cable. Factory terminated. Type: ELK-H, -HS, -Q ELW-H, -HS, -Q

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Dry ice cleaning with COOLMASTER

Instruction Manual 1.1 CU. FT. Upright Freezer UF-114W (WHITE) UF-114SS (STAINLESS STEEL)

NEW Flush-mount Glass Touch Panel to cover up to 200m2 water surface!

Goldpress 4+ OPERATING, MAINTENANCE AND SAFE USAGE MANUAL OF THE GOLDPRESS 4+ MACHINE

INFRARED PANEL HEATER

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

GOLD GV. Venting Supplement for 3 venting. Water Boiler Series 3 & 4

Instructions for use Built-in unit CC4727S / 4000 CC4927S / 4000 CC41227S / 4000

INVESTMENT PROJECT. Implementation by: JV UKRINTERM COMPANY LIMITED

SKIES MILTONIA HOME EFFICIENCY TIPS

Installation and Operation Guide

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

for relative humidity and temperature

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

INSTRUCTION MANUAL HAND HELD STEAM CLEANER JQ688A-1

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Hot Water Circulator Pump LRP

Mix Boiler & Font Range ( #, #, #, , )

The electronic anti-scale system

compact ceramic heater

Cassia Siamia ADVANCED MODELS AQDD-XL-RSH SERIES. MINI QUARTZ DISTILLER Standard Panel Series

15KW ELECTRIC FAN HEATER

Infrared heater - Item Description. Print

Pond Pump 280 / 420 / 575. Operating instructions Notice d emploi Instrucciones de uso

In-class disassembly exercise

INSTRUCTION MANUAL AIR COOLER

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

with plasma ioniser and Remote Control USER MANUAL

The result of decades of experience and technical innovation: four individually applicable product ranges with 14 different models.

13. Fun with Magnets

FireMaster Instrument cable tray fire protection

The electronic anti-scale system

INSTALLATION GUIDE AND CHECKLIST

IT AFEM. Table of Contents. Error! Table not allowed in footnote, endnote, header, footer, comment, or text box.

Operating Manual. for. SMD/BGA Rework System IR860

Sterilizing Washer E2S-7000 Operating Manual

Manual for Ceiling Patio Heater

MOUNTING GUIDE. MOUNTING INSTRUCTIONS FOR MODULAR UNDERFLOOR HEATING MESH FOR INDOOR code PVMR

Plant-A-Plant Carbon Dioxide II Laboratory Guide

EUROSTER 11E CENTRAL HEATING/UTILITY HOT WATER SYSTEM PUMP CONTROLLER

WaterVue Bluetooth Bathroom Music System

RFM Series RFM-ISR Barrier. Installation Manual

EUROSTER 11Z CENTRAL HEATING / UTILITY HOT WATER PUMP CONTROLLER

DANSANI MIDO NEW TERRA GREY. Dansani.co.uk

QUICK START IMPORTANT: PLEASE READ BEFORE OPERATING CLEANER ENG ESP FRA DEU ITL POR QUICK START OPERATOR MANUAL FOR THE FOLLOWING CLEANERS

Model Ri551. Domestic Refrigerator Operation Instructions

WATER STERILIZERS TYPE: AM1; AM2; AM3; AM4; AM5; AM6; AM8; AM10; AM12; AM15

Composite Cans. The World's No. 1 in Can Machinery. Manufacturing & Systems

Basic Cleaning Concepts

HOT WASHER MODEL NO: KING150

installation guide and operating manual for powder-coated metal infrared heaters PB0210-PB1410 Stand: Januar 2018

Rapide Deluxe PT. User Guide V-026PTS. Performance is everything. vax.co.uk

Transcription:

LAPIS-EX boiler scale removing device CONTENTS Description Component parts Application Accessories Instruction for instalation Servicing and Technical Data Diagram

DESCRIPTION Lapis-ex is an electronic device whose principle of operation is based on the use of changeable electromagnetic field, powered by permanent current supply. It is intended to prevent problems of calcium carbonate (boiler scale) forming on the inside of water pipes. Lapis-ex prevents boiler scale sediment from forming through the process of changing its crystal structure. Boiler scale affecting water supply systems causes loss of energy and pressure drop. Lapis- ex successfully eliminates this problem and saves considerable amounts of heat as well as energy. ENERGY LOSS RESULTING FROM BIOLER SCALE EFFECT 12,7 70% Thickness of boiler scale layer 6,4 3,2 1,6 15% 25% 39% 1 8% 0% 20% 40% 60% 80% 100% % energy loss (cost rise) Lapis-ex has the following functions: cleaning function: causes washing out of boiler scale after by softening and dissolving of the sediment protective function: prevents forming of sediment and its settling on the inside of water pipes KOMPONENT PARTS Lapis- ex consists of three main parts! Mains power unit! Generator! Work control system ~230V/50Hz Mains power unit Generator Work control system Output All component parts are placed in a casing made of the ABS material of 120 mm x 65 mm x 40 mm with a metal part for fixing the whole unit in position. 1.5m length of double insulation power lead with a plug, go out of the left side of the casing. On the right side, there are two banana plug sockets for connecting the output leads. On the front cover there are two photodiodes: yellow and red. The yellow one indicates correct functioning of the unit, the red one indicates current supply. Lapis- ex is filled with encapsulating compound which gives it protection against harmful weather conditions.

APPLICATION Lapis-ex is a device friendly to the environment. It is ideal for a wide variety of water supply systems as it does not come into direct contact with water nor does it change the chemical composition of water. In order to achieve required effects Lapis- ex should be kept in permanent state of operation. Lapis-ex protects against boiler scale: local water supply systems water heat exchangers and boilers water heaters water supply pipes distributing water to housing estates central heating systems water supply systems of laundries, hospitals, bakeries, sugar factories, hotels, swimming pools etc. Advantages of using Lapis-ex: prevents the process of settling of boiler scale dissolves boiler scale sediments already formed on the inside of water pipes no repairs of water pipes required saves energy and heat no contact with water no chemicals required low running costs safe and easy installation Compared with other methods of boiler scale removing the using of Lapis- ex has proved to be cheaper and less difficult to operate. Lapis- ex is a self- contained device which does not require the use of any other apparatus. It requires less effort in installation and operation, it is friendly to the environment and what is most important, it is effective. ACCESSORIES The complete set consists of: recycleable cardboard box, Lapis-ex device with a power lead, two metal screwes 0 6 mm. two insulated leads (0,75 mm2) of 1m in length- each one is ended with a banana plug on one end, and a connector pin on the other, two adhesive film insulation bands of 35mm in width and 450mm in length, two aluminium foil conducting bands of 25mm in width and 450mm in length, two metal band clips of 60mm - 145mm, user's manual and guarantee certificate.

INSTRUCTION FOR INSTALLATION Lapis-ex should be installed in a place where there is no risk of damage resulting from hitting or flooding. In order to avoid the risk of an electric shock or fire basic industrial safety rules must be observed. Avoid any squeezing, pulling or stretching of the power lead and keep it safe from any other sort of damage. In case of damage to the power lead, switch off the mains power supply immediately. Fix Lapis-ex to the wall using metal screwes. Place it near the pipe which is to be treated. Install both band clips on the supply pipe so that the water is treated before it reaches the subsequent elements of the whole system. If the system has a water pump, Lapis- ex should be installed closely to where the water flows out of the pump. In order to increase the effectiveness of Lapis- ex, it is recommended to put in approx. 1m length of pipe bigger in inside diameter than the rest of the pipeline. For example, use a section of 120mm in diameter for a pipe of 80mm (maximum inside diameter of the pipe - 150mm). For installation of Lapis- ex follow these steps: remove the insulation layer from 200mm length of pipe, clean and prepare it for installation of Lapis-ex, wind two adhesive film insulation bands on the prepared length of pipe within the distance of 120mm from each other (measured from the middle of each band)- the bands are not required if the pipe is made of plastic, wind the aluminium foil bands on top of the insulation bands, place the metal band clips on top of the aluminium foil bands. fix Lapis- ex to the wall using the metal screwes, connect the metal band clips to Lapis- ex using two insulated leads, connect the power lead to mains power supply (~230V/ 50-60Hz), make sure that both photodiodes have lit. If the red photodiode does not light, check the connection of the power lead. If the yellow photodiode does not light, make sure that any of the metal band clips does not touch the metal pipe. In case of short- circuiting the metal band clips while Lapis- ex is working, there is no danger of an electric shock or damage to the device. The way the component parts have been encased ensures correct functionning of the unit which requires no servicing. The producer takes no responsibility for the device being used in ways or for purposes other than those specified.

SERVICING Lapis-ex requires no servicing if installed according to the user's manual. A visual inspection is recommended to be performed periodically. TECHNICAL DATA! Voltage ~230V/50-60Hz! Power input <10mA! Pipe size Max. 150 mm! Flow 1,5 m / s! Dimensions 120 x 65 x 40mm!! Insulation class Classification of product Lapis-ex has been ascribed to the SWW 0719-149 group, whereas according to the norm of PKWiU to the 29.24.12-30.39 group. According to Dz.U.Nr 5 issued on 28 th January 2000, item 53 Lapis-ex is no subject to certification or attestation DIAGRAM metal band clip adhesive film insulation band aluminium foil conducting band