Heat Alarm User s Manual

Similar documents
Smoke Alarm User s Manual

WIRELESS PHOTOELECTRIC SMOKE ALARM

IMPORTANT SAFETY INFORMATION PLEASE READ AND SAVE THESE INSTRUCTIONS

V-MUL-033(A0) RADIOLINK BASE

Smoke Alarm. 120V AC Ionization. Smoke Alarm. Back-up. with 9V Battery

_EN_V4:_ :46 AM Page 1 USER S MANUAL 0086-CPD

120V AC Smoke Alarm with 9V Battery Back-up

Smoke Alarm User Manual

Invensys Controls Americas

OWNER'S MANUAL. PLEASE READ AND SAVE! Installer: Please leave this manual with the product.

Smoke Alarm User Manual

Smoke Sensor w/escape Light. Do not use this sensor in hazardous (classified) locations or life safety applications.

MODEL SS-901 EARLY WARNING PHOTOELECTRIC SMOKE & FIRE ALARM READ ALL INSTRUCTIONS

RMS-I-DE-01 Smoke Detector

WIRELESS CARBON MONOXIDE ALARM

This Heat Alarm must only be wired to a 240Vac 50Hz sine wave current supply.

User s Manual SPECIAL COMPLIANCE CONSIDERATIONS INSIDE THIS MANUAL LIMITATIONS OF SMOKE ALARMS. Double Sensor Smoke Alarm Cat.

LIFESAVER MODEL SL240 REMOTE VISUAL SIGNALLING DEVICE (STROBE LIGHT)

Smoke Alarm SMOKE ALARM FEATURES

INSTALLATION AND OPERATION MANUAL

SMOKE & HEAT DETECTOR

Visit Us on the Web! MODEL SS-795 EARLY WARNING SMOKE & FIRE ALARM WITH SILENCE CONTROL

Carbon Monoxide Alarm User s Manual

Smoke Alarm User s Guide

PHOTOELECTRONIC SMOKE DETECTOR

USER S MANUAL. BATTERY POWERED PHOTOELECTRIC SMOKE ALARM WITH SILENCE FEATURE Models 710E, 710LE and SA710CE

USER S MANUAL SMOKE ALARMS

USER S MANUAL SMOKE ALARM

_V4:_ :28 AM Page 1. For model 29D,29HD. Photoelectric Smoke Alarm. User Guide

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

U S E R M A N U A L UBH1RF HEAT ALARM

Heat Alarm User s Guide

MODEL MP316S PHOTOELECTRIC SENSING TECHNOLOGY SMOKE & FIRE ALARM WITH 10 YEAR PERMANENT POWER SEALED BATTERY

Smoke Alarms and Carbon Monoxide Alarms

230V Interconnectable Mains Operated Alarm model. For: 1275H

USER S MANUAL SMOKE AND FIRE* ALARMS

USER S MANUAL SMOKE AND FIRE ALARM

WIRELESS SUPERVISED PHOTOELECTRIC SMOKE DETECTOR DÉTECTEUR DE FUMÉE PHOTOÉLECTRIQUE SUPERVISÉ SANS FILS. Model: EL-2703

USER S MANUAL SMOKE ALARMS

SF812 SMOKE DETECTOR. Include to or Exclude from a Z-Wave TM Network. Product Overview

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

Smoke & Carbon Monoxide Alarms

USER S MANUAL WIRELESS ONELINK AC POWERED SMOKE ALARM WITH BATTERY BACK-UP

9000 SERIES PHOTOELECTRIC TYPE SINGLE STATION/ MULTI-STATION SMOKE ALARMS AC POWERED WITH BATTERY BACKUP

Photoelectric Smoke Alarm

Smoke Alarm User s Guide

Operating instructions for the radio heat detector GS412

NO VENTING REQUIRED 120V AC;

SMOKE & CARBON MONOXIDE ALARMS

USER MANUAL 10 YEAR LIFE SMOKE ALARM

700 SERIES. PHOTOELECTRIC TYPE SINGLE STATION/MULTI-STATION SMOKE ALARMS AC POWERED, 120V, 60Hz or 220V, 50Hz

EN ES-D5B Wireless Smoke Detector. Instrukcja pobrana ze sklepu

SMOKE DETECTOR USERS GUIDE SMOKE DETECTOR SETUP GUIDE

Carbon Monoxide Alarms Smoke and Carbon Alarms Upgrade Requirements for Single and Two Family Dwellings

SMOKE ALARMS City of Grand Rapids Building Safety Division

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

MODEL MDS300, MDS300L MODEL MDS500, MDS500L. IoPhic SMOKE & FIRE ALARM WITH SILENCE FEATURE AND ALARM ORIGINATION FEATURE

½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E

OWNER'S MANUAL PLEASE READ AND SAVE!

RADION smoke RFSM-A. en Installation Guide

MFES READY Make your home fire safe. Home Smoke Alarms

Heat Alarm. Owner s Manual. Model CFH10. Rate of Rise Temperature Sensing Selectable Fixed Temperature Sensing Proprietary Wireless Connectivity

USER INSTRUCTIONS MULTI-SENSOR FIRE ALARM 230V~ with Rechargeable Lithium Cell Back-up. Model: Ei2110

EWF1 EWF1CO WIRELESS SMOKE DETECTOR WIRELESS SMOKE & CO DETECTOR

ADT Smoke Alarm. Setup Guide

MODEL MP116S PHOTOELECTRIC SENSING TECHNOLOGY SMOKE & FIRE ALARM WITH 10 YEAR TAMPER PROOF PERMANENT POWER SEALED BATTERY BACKUP

1 Introducing Eve Smoke

Photoelectric Smoke Alarm User s Guide

MODEL 5304, 5304L SMOKE & FIRE ALARM WITH SILENCE FEATURE AND ALARM ORIGINATION FEATURE

2

2

PHOTOELECTRIC TYPE SINGLE STATION/MULTI-STATION SMOKE ALARMS, AC POWERED WITH BATTERY BACKUP

Smoke Alarm User s Guide

Earn BISSELL Rewards! Register your

B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page Installation Guide

B16351-R0-Ei2100 SERIES-USE.qxd 18/9/08 3:47 PM Page 1 230V~ MULTI-SENSOR FIRE ALARM with Rechargeable Lithium Cell Back-up.

1. Safety instructions Mounting location in rooms of the heat detectors... 3

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY

Residential Fire Protection

Heat Sensor. Owner s Manual

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

PHOTOELECTRIC TYPE SINGLE STATION/MULTI-STATION SMOKE ALARMS/AC POWERED, 120VAC, 60Hz OR 220VAC, 50/60Hz

VERNON ELECTRIC FIREPLACE

SI-610 / SO-610 User Manual. 10 Year Smoke Alarm Standard / Toast Proof with Smart Silence

WIRELESS INTERLINK SMOKE ALARM + 10 YEAR LIFE WST-630

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

OWNER S MANUAL ELECTRIC FIREPLACE INSERT. Model No.: WESTERN (EF42D-45D) WARNING CAUTION

INSTALLATION AND USER MANUAL

Smoke Alarm User s Guide

Wireless Interlink Smoke Alarm + 10 Year Life

Alice. In Wall Recessed Electric Fireplace Model Number: (EF172B, EF173B, EF174B, EF175B, EF176B) OWNER S MANUAL

Smoke Alarm. Owner s Manual. Model CFS10. Combination Alarm

Can I Interconnect Smoke Alarms and Carbon Monoxide (CO) Alarms?

FerronTM. Instruction Manual A Kichler Decor ceiling fan

CORDLESS HAND VACUUM USER GUIDE BOLT 1316 SERIES

Operating instructions for the wireless smoke alarm detector type: GS558

HOW TO TELL IF YOUR SMOKE ALARM IS WORKING PROPERLY

Transcription:

V-MUL-009-A(A0) Heat Alarm User s Manual Please read and save this manual FIXED TEMPERATURE HEAT ALARM MODEL: VST-H598I Class II Apparatus Heat alarms are ideal for kitchen, garages, basements, boilers rooms, attics and other areas where there are normally high levels of fumes, smoke, or dust which are also for areas where smoke alarms should not be installed due to risk of false nuisance alarms. MAIN FEATURES AC/DC operated type heat alarm The heat alarm is sensitive only to a fixed temperature Less nuisance alarms due to contamination, dust, and insects Quick fix mounting bracket and simple AC connector for easy installation Fitting and battery tamper-resist feature Alarm and AC power supply indicator Extra loud alarm sound over 85 db Inter-connectable up to 40 units Low-battery and battery missing warning sound Self-test button Auto-hush function when temperature is below alarm point SPECIFICATION Model Number: VST-H598I Operation Temperature: -23 C to 70 C Power Source: 220-240V AC 50Hz and 9V DC Battery back-up Alarm point: 58 (135 ) fixed temperature triggers alarm Alarm Sound Level: 85 decibels at 3m (10 feet) Standby Current (9V battery): 15u A max Alarm Current (9V battery) : 20m A max Recommended Coverage: 232 m 2 (2500 square feet ) Recommended Spacing: 15m (50ft) Maximum Distance from wall: 7.5m (25ft) Compact size: 110mm diameter WARNING

Heat alarms are not life safety devices and are not designed to detect smoke of fire. Heat alarms detect temperatures of 58 (135 ) or greater, and are intended to be used as supplements to smoke alarms by providing early warning. IMPORTANT SAFETY INFORMATION 1. This heat alarm requires constant 220-240V AC 50Hz mains power supply to operate properly. Backup 9V DC battery will offer additional protection in the event of power failure. This heat alarm WILL NOT work if AC power is not connected or has failed or been interrupted for any reason. AND if the backup battery is removed, drained or improperly connected, the alarm will not work during a power failure. DO NOT use any other kind of battery except as specified. 2. The Test button accurately tests all heat alarm functions. For temperatures that are below 0 use a hand held hair dryer and blow hot air into heat alarm to test. DO NOT use any other test method. Test heat alarm weekly to ensure proper operation. 3. Observe and follow all local and national electrical and building codes for installation. 4. This heat alarm is designed to be used inside a single room building only. In multi-room buildings, each individual living unit should have its own heat alarm. DO NOT install the alarm in non-residential buildings or places which house many people like hotels, motels, dormitories, hospitals, nursing homes, or group homes. This heat alarm is not a substitute for a complete alarm system. 5. Heat alarms should be used as supplements to smoke alarms in order to provide early warning of heat, smoke or fire. In addition, Heat alarms should be installed in every bedroom and on every level of the home. This alarm may not always detect slow, smoldering, low heat producing fires. In addition, heat from a nearby fire may bypass the heat alarm. 6. Heat alarms may not alert every household member every time. The alarm horn of the heat alarm is loud in order to alert individuals of a potential danger. However, there may be limiting circumstances where a household member may not hear the alarm (i.e. outdoor or indoor noise, sound sleepers, the hard of hearing, etc.). If you suspect that your heat alarm may not alert a household member, install and maintain special heat alarms. 7. This heat alarm can only sound its alarm when it detects temperatures of 58 (135 ) or greater. Heat alarms do not detect smoke, flame, or gas.in some fires, hazardous levels of toxic chemicals and smoke can build up before a heat alarm will operate. Temperatures may not reach 58 (135 ) to activate the heat alarm QUICKLY ENOUGH to ensure safe escape. 8. Heat alarms have limitations. This heat alarm is not foolproof and is not warranted to protect lives or property from fire. Heat alarms are not a substitute for insurance. Homeowners and renters are responsible for insuring their lives and property. In addition, it is possible for the heat alarm to fail at any time. HEAT ALARM PLACEMENT Heat alarms have an audible warning when the temperature at the alarm reaches 58 (135 ).Heat alarms are ideal for kitchens, garages, basements, boilers rooms, attics, and other areas where there are normally high levels of fumes, smoke, or dust. Single-Story Residence Two-Story Residence

Key: Minimum required smoke alarm locations Recommended additional smoke alarm locations Recommended heat alarm locations HEAT ALARM LOCATIONS 1. Install a heat alarm as close to the center of the ceiling as possible. If this is not practical, mount the alarm no closer than 4 inches from a wall or corner. 2. If ceiling is not practical or the mounting surface may becomes considerably warmer or cooler than the room, such as a poorly insulated ceiling, below an unfinished attic or an exterior wall, and if local codes allow, install heat alarms on walls, between 4 and 12 inches from ceiling /wall intersections. 3. Install heat alarms on peaked, cathedral, or gabled ceilings 3 feet from the highest point (measured horizontally). 4. In a room with open joists or beams, all ceiling mounted heat alarms shall be located on the bottom of joists or beams not in channels. 5. Heat alarms installed on an open-joisted ceiling shall have their smooth ceiling spacing reduced to no more than half of the listed spacing when measured at right angles to solid joist. DO NOT INSTALLL HEAT ALARMS: 1. In areas with high humidity, like bathrooms or areas near dishwashers or washing machines. Install at least 3 meters (10 feet) away from these areas, if possible. 2. Near air returns, heating and cooling supply vents, fans, decorative objects, window molding etc. that may prevent heat from entering the unit thus interrupting its alarm. 3. In rooms where temperatures may fall below -23 or rise above 70. 4. Near fluorescent lights-electrical noise and flickering may affect the alarm s operations. WARNING: Incorrect orientation will result in a decrease in operational effectiveness.

HOW TO INSTALL THIS HEAT ALARM DANGER: ELECTRICAL SHOCK HAZARD. Turn off power at the main fuse box or circuit breaker by removing the fuse or switching the circuit breaker to the OFF position. WARNING: This heat alarm is mains powered and requires wiring by a qualified electrician in accordance with the current IEE Regulations for Electrical Installations (BS7671). The circuit used to power the heat alarm must be a dedicated permanent supply that cannot be switched off accidentally by the normal user. Before installing ensure the electrical supply is isolated. 1. From back of heat alarm, remove the mounting plate by turning it counterclockwise. (To later engage tamper-resist feature, twist out and set aside one of the pins molded into plate. Both pins are exactly the same.) 2. Gently pull household wires through center hole of plate. 3. Secure plate to ceiling or wall with mounting screws. 4. With a small wire connector, connect brown wire from connecter plug to brown household wire. 5. Connect blue wire from connector plug to blue household wire. 6. If interconnection is desired, connect yellow wire from connector to interconnect wire between heat alarms. See section INTERCONNECTING HEAT ALARMS. NOTE: If this will be used as a single-station heat alarm, cover yellow wire with electrical tape and tuck it into junction box. 7. Lift open battery pocket door. 8. Connect new 9-volt battery to battery connector inside battery pocket. Be sure battery is securely connected. Heat alarm may beep briefly when battery is installed. 9. Close battery pocket door, snapping it into place. 10. Attach connector plug to pins on back of heat alarm. Plug will only fit one way and will snap into place. 11. Gently tug connector to be sure it is attached securely. 12. Position heat alarm to mounting plate and turn clockwise to lock into place. To engage tamper-resist feature, insert pin into notch on edge of heat alarm after alarm is properly positioned in base. NOTE: Heat alarm will not mount to plate if battery is not installed. 13. Turn on power at main fuse box or circuit breaker. 14. Push test button to test heat alarm. See TESTING THE HEAT ALARM.

INTERCONNECTING HEAT ALARMS For interconnecting line, only use #14-#18 AWG minimum solid or stranded wire. When being interconnected, maximum wire length between any two is 1500 feet for #18 AWG or 4000 feet for #14 AWG (20 OHMS loop resistance). This heat alarm can be interconnected with as many as 40 other DC or AC ORIENTALERT heat alarms and/or smoke alarms. Do not connect to any other type or model heat alarms except the ones we specify. And this heat alarm is powered by 220-240V AC 50Hz and with 9V DC Battery back-up. OPERATING YOUR HEAT ALARM Once the heat alarm has been installed a small GREEN indicator light (LED) should be visible through the alarm grill indicating that AC supply is healthy. A RED indicator light (LED) should also flash approximately once a minute to indicate the battery is healthy and the unit is operating properly. If heat is detected, the unit will emit a load pulsating alarm and a RED indicator light (LED) will be flashing quickly until the detected temperature is below its fixed temperature. TESTING THE HEAT ALARM 1. Test each heat alarm to be sure it is installed correctly and operating properly. 2. The Test button accurately tests functions. Do not use an open flame to test this heat alarm. You may ignite and damage the heat alarm or your home. 3. Test heat alarms weekly and upon returning from vacation or when no one has been in the household for several days. 4. Stand at arm s length from the heat alarm when testing. TEST ALL HEAT ALARMS WEEKLY BY DOING THE FOLLOWING: 1. Firmly push the TEST button, and the heat alarm will sound a loud beep. The alarm will stop sounding after releasing the TEST button. 2. If heat alarm does not sound, please retest it. DANGER: If the alarm sounds, and heat alarm is not being tested, the heat alarm is sensing 58 (135 ) or greater temperature. THE SOUND OF THE ALARM REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION.

MAINTENANCE AND CLEANING In addition to weekly testing, this heat alarm requires yearly battery replacement and periodic cleaning to remove dust, dirt, and debris. BATTERY REPLACEMENT Always turn off the AC supply to the heat alarm before replacing the battery. Replace battery at least once a year or immediately when the low battery signal sounds once a minute, even though the heat alarm is receiving AC power. Batteries should be replaced regularly as necessary. WARNING: Do not use any other type of battery, except as specified in this manual. Do not use rechargeable batteries. CAUTION: Explosion will happen if battery is incorrectly replaced. You d better use good battery to make the alarm work long. Some batteries can be used more than one year. The battery should only be replaced by a qualified electrician or similarly qualified person. 1. Turn off AC power supply to the heat alarm. 2. Turn heat alarm counterclockwise to detach it from the mounting plate. 3. Gently pull down heat alarm. 4. Remove battery from the compartment. 5. Insert a new 9-volt battery to connector. NOTE POLARITY OF CONNECTIONS. Ensure the metal tab is fully depressed when the battery has been fitted. 6. Using the Test button, test the heat alarm to verify 9V DC battery back-up. See TESTING THE HEAT ALARM 7. Reattach the heat alarm to the mounting plate by turning smoke alarm clockwise until it snaps into place. 8. Turn on power supply and test heat alarm using Test button. See TESTING THE HEAT ALARM CHOOSING A REPLACEMENT BATTERY: The unit requires one standard 9V battery. The following batteries are acceptable as replacements: Megaton #6F22; New Leader #6F22; Gold Peak #1604; Eveready #522, #1222; Golden Power G6F22, Golden Power GL6F22A CLEANING Clean the heat alarm at least once a month to remove dust, dirt, or debris. Always turn off power to heat alarm before cleaning. Using the soft brush or wand attachment to a vacuum cleaner, vacuum all sides and cover of heat alarm. Be sure all the vents are free of debris. If necessary, use a damp cloth to clean heat alarm cover. IMPORTANT: Do not attempt to remove the cover to clean inside the smoke alarm. This will void your warranty. WARNING: Do not attempt to remove the cover to clean inside the heat alarm. This will void your warranty. PRACTICE FIRE SAFETY If the heat alarm sounds its alarm horn, and you have not pushed the test button, it is warning of a dangerous

situation. Your immediate response is necessary. To prepare for such occurrences, develop family escape plans, discuss them with all household members, and practice them regularly. 1. Expose everyone to the sound of a heat alarm and explain what the sound means. 2. Determine two exits from each room and an escape route to the outside from each exit. 3. Teach all household members to touch the door and use an alternate exit if the door is hot. Instruct them not to open the door if the door is hot. 4. Teach household members to crawl along the floor to stay below dangerous smoke, fumes and gases. 5. Determine a safe meeting place for all members outside the building. WHAT TO DO IN CASE OF FIRE 1. Do not panic; stay calm. 2. Leave the building as quickly as possible. Touch doors to feel if they are hot before opening them. Use an alternate exit if necessary. Crawl along the floor, and do not stop to collect anything. 3. Meet at a pre-arranged meeting place outside the building. 4. Call the fire department from outside the building. 5. Do not go back inside a burning building. Wait for the fire department to arrive. These guidelines will assist you in the event of a fire. However, to reduce the chance that fires will start, practice fire safety rules and prevent hazardous situations. TROUBLESHOOTING WARNING: DO NOT disconnect battery to quiet an unwanted alarm. This will remove your protection. PROBLEM Heat alarm does not sound when tested. NOTE: Push test button for at least five seconds while testing! Heat alarm beeps about once a minute. Heat alarm sounds unwanted alarms The alarm sounds different than I m used to. It starts and stops. SOLUTION 1. Remove heat alarm from mounting plate and check that battery is properly attached to connector. 2. Clean heat alarm. Replace battery. See battery replacement in the maintenance and cleaning section. 1. Clean heat alarm. See cleaning in the maintenance and cleaning section 2. Hire an electrician to move heat alarm to a new location. See HEAT ALARM PLACEMENT The alarm is operating correctly. This alarm features the internationally recognized horn signal for evacuation. The alarm sound pattern is 3 short beeps followed by a 2 second pause and then repeats. Manufacturer: Xiamen Vs-Top Electronics Co., Ltd. 2nd floor, No. 107 Xiaguang Road, Xinyang Industrial District, Haicang, Xiamen, China. Tel: 0086-592-6017700 Fax: 0086-592-6017711 E-mail: info@vs-top.com Website: www.orientalert.com