Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Similar documents
Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Electrochemical (EC) DrägerSensors for Fixed Gas Detectors

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Bump Test Station Calibration and Bump Testing

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Pac 7000 Single-Gas Detection Device

Dräger Pac 5500 Single-Gas Detection Device

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Configuration and Evaluation Software

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Catalytic Bead DrägerSensors for Fixed Gas Detectors

Dräger Pac 8000 Single-Gas Detection Device

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger REGARD -1 Control System

Dräger X-am 5000 Multi-Gas Detection

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger REGARD 3900 Series Control System

Dräger GS01 (wireless) Detection of flammable gases and vapours

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger QuadGard Control System

Dräger Pac 3500 Single-Gas Detection Device

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger X-am 2500 Multi-Gas Detection

Training Authorised Gas Tester Level 1. Basic Information

Dräger X-pid 9000 / 9500 Multi-Gas Detection

Training Gas Detection Level 3 Maintenance and Repair

On-site & Shutdown Safety Service CSE Monitoring

Training Gas Detection Level 2 User and Calibration. Basic Information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

GS01 (wireless) Detection of flammable gases and vapours

Dräger Pac 6000 Single-Gas Detection Device

Dräger X-am 7000 Multi-Gas Detection

Dräger X-am 5000 Multi-Gas Detector

Dräger PEX 3000 Flammable Gas Detection

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger PIR 7200 Detection of toxic gases and oxygen

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger X-am 2500 Multi-Gas Detector

Dräger Pac 8500 Single-Gas Detection Device

Powder Extinguisher ABC - composite Portable powder extinguishers

Portable wet chemical extinguishers

Dräger VVP 1000 System Components

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger Flame 5000 Flame Detection

Powder Extinguisher ABC (stored pressure) Portable powder extinguishers

Foam Extinguisher AB - composite Portable foam extinguishers

Dräger X-zone 5500 Area Monitoring

Dräger Bodyguard 1000 Warning Device

Dräger PIR 7000 Flammable Gas Detection

Dräger X-am 5000 Multi-Gas Detection

Dräger FRT 1000 / ETR 1000 Location Devices

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

The SharpEye 40/40I (IR3) Flame Detection

Foam Wheeled Extinguisher AB Movable fire extinguishers

D Safe, realistic, reliable DRÄGER FIRE TRAINING SYSTEMS

Dräger Flame 5000 Flame Detection

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger REGARD -1 Control System

Dräger X-zone 5500 Multi-Gas Detection Device

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger X-plore 8000 Powered Air-Purifying Respirator (PAPR)

Dräger Pac 3500 Single-Gas Detection Device

The SharpEye 40/40M (Multi IR) Flame Detection

Dräger Flame 2500 (IR3) Flame Detection

VarioAir Medical Suction Solutions Consumables and Accessories

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger REGARD -1 Control System

Tropic 2.0 ultrasonic nebuliser

VarioVac vacuum regulators Consumables and Accessories

Dräger Flame 2370 (UV&IR) Flame Detection

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger OR Lights Simply good light

Dräger VentStar Helix heated (N) plus Consumables and Accessories

Dräger Pac 6000 Single-Gas Detector

ST More than the sum of their components GAS DETECTION SYSTEMS

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Toxic Gas Detection. Model F12. Toxic Gas Detection

Dräger X-zone 5500 Area Monitoring

OLC(T) 100 FIXED GAS DETECTOR

Dräger PIR 7200 Toxic Gas Detection Transmitter

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Flame 2100 (UV) Flame Detection

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

D D D Dräger Gas Detection ST Dräger: Technology for Life

Oxylog VE300 Emergency & Transport Ventilation

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Dräger Polytron 8700 IR Detection of flammable gases and vapors

The SharpEye 40/40I (IR3) Flame Detection

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Dräger Pac 8500 Single-Gas Detector

GAS DETECTOR ST400EC PART.NO

Oxylog VE300 Emergency & Transport Ventilation

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Transcription:

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors Fast response, high accuracy, great stability, long life. Electrochemical DrägerSensors offer all these benefits. You can use the robust and longlife sensors for the selective measurement of the smallest concentrations of toxic gases and oxygen in ambient air. Memory chip Pressure release Electrochemical system D-19051-2016 Filter

02 Electrochemical DrägerSensor Benefits Long lifetime The electrochemical are designed to provide a reliable und stable measurement function over a long period of time. The use of resistant plastics, such as PTFE, and the purest catalysts make this possible. Additionally, a huge electrolytic reservoir and large electrode areas provide sufficient reserves for a long lifetime. The construction of the DrägerSensors offers you long stability and a low age-related drift. Ready for immediate use All DrägerSensors are factory calibrated with the target gas. These values are saved in the internal, electronic memory. You can use the sensors in the field immediately. For some sensors other tagret gases can be selected from the internal gas library. Comprehensive range of applications All sensors have an internal temperature sensor. Between -40 C and +65 C, the temperature influence is compensated for zero and sensitivity. The patented internal pressure compensation balances adverse ambient conditions, such as humidity changes or barometric variation. Due to this fact, you can use the sensors even in high or low pressure. For some sensors you can reduce the disturbing influence of cross-sensitivities by combining selective filters. Performance features Low detection limits Optimised selectivity Excellent accuracy of measurements Fast response Comprehensive self-diagnosis options It is possible to choose between oxygen sensors for partial pressure measurement or volume percent measurement Sensors with organic electrolyte for detection limits in lower ppb range Acid gas sensor AC with unlimited lifetime, due to refillable electrolyte

Electrochemical DrägerSensor 03 System Components Dräger Polytron 7000 The Dräger Polytron 7000 is a gas detector that can satisfy many toxic and oxygen gas measurement applications on a single platform. It meets the requirements of the compliance market as well as the high specification requirements of customised solutions. ST-3811-2003 ST-3812-2003 Dräger Polytron 3000 The Dräger Polytron 3000 is an intrinsically safe gas detector for the continuous monitoring of more than 60 toxic gases and oxygen in ambient air. It is the part of a new generation of gas detectors developed on a modular platform. Communication to the central control system is done via a 4 to 20 ma signal. Dräger Polytron 8100 EC D-52604-2012 The Polytron 8100 EC is Dräger s top of the line explosion-proof transmitter for the detection of toxic gases or oxygen. It uses a high performance plug and play electrochemical DrägerSensor to detect a specific gas. Besides having a 3-wire 4 to 20 ma analogue output with relays, it also offers Modbus and Fieldbus protocol making it compatible with most control systems. Dräger Polytron 5100 EC The Dräger Polytron 5100 EC is a cost-effective explosion-proof transmitter for the detection of toxic gases or oxygen. It uses a high performance plug-and-play electrochemical DrägerSensor to detect a specific gas. A 2 or 3-wire with 4 to 20 ma output with relays make it compatible with most control systems. D-158-2016

04 Electrochemical DrägerSensor Accessories Calibration bottle Made of plastic, this 3-litre container for generating a defined concentration of gas, using test gas ampoules, when calibrating electrochemical DrägerSensors. ST-5695-2006 ST-5653-2006 Test gas ampoules Test gas ampoules are used in conjunction with the calibration bottle. They are available for various gases and concentrations. Dust filter Thiy hydrophobic dust filter for electrochemical DrägerSensors (see also the corresponding sensor data specification). D-4789-2017 ST-5718-2006 Selective filter Selective filters absorb interfering gases from the ambient air. They are located in the sensor opening of the DrägerSensor and can easily be replaced if worn out.

Electrochemical DrägerSensor 05 Accessories Viton calibration adapter The flexible, soft calibration adapter, made of Viton, is used for gassing during zero point test and when calibrating electrochemical DrägerSensors. ST-5676-2006 Related Products DrägerSensor IR Upgrade from catalytic bead to infrared technology with ease using the DrägerSensor IR. The Sensor IR can replace catalytic ex-sensors (pellistors) from the majority of manufacturers without replacing controllers, cables, junction boxes or control systems. D-1119-2010 ST-8821-2005 Catalytic Bead DrägerSensor The catalytic bead DrägerSensor is designed for the continuous monitoring and detection of combustible gases and vapours with different versions for different applications or concentrations.

06 Electrochemical DrägerSensor Ordering Information Target gas DrägerSensor Part number Detection limit max. range Comment Vol% Vol% Oxygen O 2 6809720 0,5 100 partial pressure Oxygen O 2 LS 6809635 0,5 25 Target gas DrägerSensor Part number Detection limit max. range Comment ppm ppm additional gases Ammonia NH 3 TL 6813095 1 300 amines Ammonia NH 3 FL 6813260 1 300 Ammonia NH 3 HC 6809645 30 1000 Ammonia NH 3 LC 6809680 5 300 amines Carbon monoxide CO LS 6809620 10 5000 Carbon monoxide CO LH 6812570 15 300 Carbon monoxide CO 6809605 5 1000 Chlorine Cl 2 6809665 0,05 50 halogene Ethylene oxide OV1 6810740 5 200 organic vapours Ethylene oxide OV2 6710745 5 100 organic vapours Hydrazine Hydrazin 6810180 0,02 5 derivitives Hydrogen H 2 6809685 15 3000 Hydrogen chloride AC 6810595 0,5 30 acidic compounds Hydrogen chloride HCl LC 6809640 1 100 halides Hydrogen cyanide HCN 6809650 1,5 50 Hydrogen cyanide HCN LC 6813200 0,1 50 Hydrogen peroxide H 2 O 2 HC 6809675 50 7000 Hydrogen peroxide H 2 O 2 LC 6809705 0,1 300 Hydrogen sulfide H 2 S HC 6809710 10 1000 Hydrogen sulfide H 2 S LC 6809610 1 100 mercaptane Hydrogen sulfide H 2 S 6810435 0,5 100 Nitrogen dioxide NO 2 6809655 0,3 100 Nitrogen dioxide NO 2 LC 6813205 0,05 20 Nitrogen monoxide NO 6809625 3 200 Ozone Ozon 6814005 0,02 5 Phosgene COCl 2 6809930 0,02 20 Phosphine Hydride 6809635 0,03 20 hydrides Phosphine PH 3 / ASH 3 6809695 0,02 20 Phosphine Hydride SC 6809980 0,01 1 hydrides Sulfur dioxide SO 2 6809660 0,5 100 Accessories Calibration bottle 68 03 407 Test gas ampoule SO 2 10 ppm 68 07 763 Test gas ampoule SO 2 50 ppm 68 07 764 Test gas ampoule NO 2 10 ppm 68 07 765 Test gas ampoule NO 2 50 ppm 68 07 766 Test gas ampoule CO 100 ppm 68 07 920 Test gas ampoule CO 300 ppm 68 07 921 Test gas ampoule NH 3 300 ppm 68 07 923 Test gas ampoule NH 3 50 ppm 68 07 924

Electrochemical DrägerSensor 07 Test gas ampoule SO 2 1 ppm 68 07 925 Test gas ampoule SO 2 4 ppm 68 07 926 Test gas ampoule Cl 2 8 ppm 68 07 928 Test gas ampoule HCN 10 ppm 68 07 929 Test gas ampoule H 2 S 10 ppm 68 08 140 Test gas ampoule H 2 S 20 ppm 68 08 141 Test gas ampoule H 2 S 40 ppm 68 08 142 Test gas ampoule H 2 S 100 ppm 68 08 143 Dust filter 68 09 595 Dust filter 68 12 224 Selective filter A2F (CO, CO LS, H 2 ) 68 09 684 Selective filter K2F (COCl 2 ) 68 09 933 Selective filter NF (HCl) 68 09 643 Selective filter BF (HCN) 68 09 653 Selective filter CF (Hydride, NO 2 ) 68 09 658 Selective filter HSF (Hydride) 68 09 862 Selective filter MF (PH 3, AsH 3 ) 68 09 638 Selective filter K1F (SO 2 ) 68 09 663 Viton Calibration adapter 68 10 536 Further calibration accessories on request Viton is a registered trademark of the DuPont company

08 Electrochemical DrägerSensor Notes Not all products, features, or services are for sale in all countries. Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released. Go to www.draeger.com/trademarks to find the current status. 90 45 596 17.02-1 HQ PP Subject to modifications 2017 Drägerwerk AG & Co. KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany www.draeger.com REGION DACH Dräger Safety AG & Co. KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draeger.com REGION EUROPE Dräger Safety AG & Co. KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draeger.com REGION MIDDLE EAST, AFRICA Dräger Safety AG & Co. KGaA Branch Office P.O. Box 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fax +971 4 4294 699 contactuae@draeger.com REGION ASIA PACIFIC Draeger Singapore Pte. Ltd. 25 International Business Park #04-20/21 German Centre Singapore 609916 Tel +65 6308 9400 Fax +65 6308 9401 asia.pacific@draeger.com REGION CENTRAL AND SOUTH AMERICA Dräger Panama S. de R.L. Complejo Business Park, V tower, 10th floor Panama City Tel +507 377-9100 Fax +507 377-9130 contactcsa@draeger.com Locate your Regional Sales Representative at: www.draeger.com/contact