CLASSIFICATION IN REGARD OF REACTION TO FIRE according to EN :2007

Similar documents
Institute of Building Technology. Classification report no: Reaction to Fire acc. PN-EN A1:2010

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Form: KSD-100:10 Page 1 of 3

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

TFI Report Classification

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Classification report

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

Additional Reaction to Fire Classification Report

Reaction to fire classification report No C-rev.1

Contact person Date Reference Page Richard Johansson P (2) Fire Research

Test Report: ICL/CR15/11/087

Additional reaction to fire classification report No H

Centrum stavebního inženýrství a.s.

Reaction to fire classification report No C

CLASSIFICATION REPORT

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

TFI Report Classification

PUBLIC SUMMARY REPORT OF THE EGOLF EN 13823

CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003

DELTA Classification Report

New European Fire Testing Classification for Construction Products

CERTIFICATE OF APPROVAL No CF 5635 P3 SRL

Classification Report

Facts about insulation and fires 29 October 2014

BCTC CARPET TECHNICAL CENTRE

gent warn nfire No, 16209C Reaction to fire class ification report lntroduction Owner of the classification report

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

Not all insulation is the same! from fire testing to real fires.

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

Sýnishorn Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

Centrum stavebního inženýrství a.s.

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

MFPA Leipzig GmbH Prüf-, Überwachungs- und Zertifizierungsstelle für Baustoffe, Bauprodukte und Bausysteme

SUBJECT: ASSESSMENT FOR INTERNAL SURFACE FINISHES OF LIGHTBETON PANEL FOR COMPLIANCE WITH THE NEW ZEALAND BUILDING CODE(NZBC)

Copy of article submitted to Fire Safety Engineering for publication January/February 2009

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW

Classification of Fire Performance of Wall and Ceiling Lining Materials

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

PROCEDURES FOR APPROVAL OF LIFE-SAVING APPLIANCES AND FIRE SAFETY SYSTEMS, EQUIPMENT AND PRODUCTS

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

Test report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO

Fire Risk and CODE Compliance For Fabric Wrapped Acoustic Panels

TFI Report Reaction to fire test

European Technical Assessment. ETA-16/0488 of 6 July English translation prepared by DIBt - Original version in German language.

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

European Technical Approval ETA-08/0035 This ETA replaces ETA-08/0035 with validity from till

We Identify and S.T.O.P. Your Noise Problems

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

Construction Products Regulation (CPR) and BS 6701

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

SKG-IKOB Certificatie B.V. Trading under the names SKG, IKOB-BKB and SKW Certificatie

TECHNICAL APPROVAL. TA no.: AT/ Edition V/2015 Date of expiry: 25 November 2020 Page: 1 of 14


CERTIFICATE OF APPROVAL No ME 5085

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

This section shall take effect on June 27, 2015 and transition period effective date of this section and June 27, 2016

Analysis Report

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

TRIMOTERM TECHNICAL SPECIFICATION

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

REVIEW ON TWO PERFORMANCE-BASED TESTS FOR ASSESSING FLAME SPREAD IN HONG KONG

Building & Site Design Standards Application

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100

CNBOP-PIB Standard Fire Protection

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

New European Cable Testing and Classification

Co-ordination of the Group of Notified Bodies for the Construction Products /Regulation 305/2011/EU

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

CNBOP-PIB STANDARDS FIRE PROTECTION. National Technical Assessments CNBOP-PIB-0036E:2017 EDITION 1 CENTRUM NAUKOWO-BADAWCZE OCHRONY PRZECIWPOŻAROWEJ

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

...our ideas your comfort

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

For more information on Tarkett go to

IMO Resolution MSC 61(67): Annex 1: Part 2

Üntel is ready for CPR

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

On Electromagnetic Compatibility

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

TECHNICAL AND USER REQUIREMENTS FOR PERSONAL ALERT SAFETY SYSTEMS

ASSESSING THE FIRE PERFORMANCE OF ELECTRIC CABLES (FIPEC)

BS EN ISO : 2010

Transcription:

SWORN TRANSLATOR & INTERPRETER OF THE ENGLISH LANGUAGE Provincial Court Gdansk, Poland EWA KOCIK 7/9 Czubinskiego Street 80-215 Gdansk tel. (48) 58 345 50 76, (48) 509 209 454 logo : Certified translation of the original document in Polish BUILDING RESEARCH INSTITUTE FIRE TESTING DEPARTMENT GROUP OF ITB TESTING LABORATORIES accredited by the Polish Centre for Accreditation Accreditation Certificate No. AB 023 FIRE TESTING LABORATORY (LP) Contract No.: NP-1064/A/08/KP Ordering party: Contracting party: Product name: CLASSIFICATION IN REGARD OF REACTION TO FIRE according to EN 13501-1:2007 Classification report no. Issue no. 1 Copy no. 1 Issue date: 2009.03.31 Izopanel Sp. z o.o. ul Budowlanych 36 80-298 Gdańsk Fire Testing Department Building Research Institute ul. Filtrowa 1 00-611 Warszawa cold storage panel with polyurethane core and visible fixing system NP-1064.6/08/KP Present classification report contains 4 pages and can be used or copied only in its entirety. 1. Introduction Present classification report specifies classification for cold storage panel with polyurethane core and visible fixing system, in accordance with procedures specified in EN 13501-1:2007 standard. 2. Detailed information on the product 2.1 General provisions Cold storage panels with polyurethane core and visible fixing system are used in construction of industrial and production halls, sports facilities, exhibition and trade halls, office buildings, amenity buildings, service buildings, air docks, garages, workshops, administration buildings, public utility buildings, storehouses, repositories, cold stores, etc. Certified translation: page 1 of 5 - Register No.: 328 / 2010

CLASSIFICATION REPORT NP-1064.6/08/KP 2/4 2.2. Product description The product is described below (according to producer s statement). cold storage panel with polyurethane core and visible fixing system is made of: - two steel linings with thickness of 0.50 mm, protected with zinc coating and an organic layer (layer used: polyester with thickness of 25μm). - core consisting of freon free, rigid polyurethane foam type PUR with density of 40 ± 4 kg/m 3, foamed with pentane. 3. Test reports and test results providing basis for classification 3.1. Test report Laboratory Ordering party Report from test No. Testing method Izopanel Sp. z o.o. LP-1064.2.12/34-23/08 PN-EN 13823:2004 Fire Testing Laboratory ul. Budowlanych 36 LP-1064.2.13/34-20/08 PN-EN 13823:2004 ITB 80-298 Gdańsk LP-1064.2.5/23-32/08 PN-EN ISO 11925-2:2004 3.2 Test results Testing method PN-EN ISO 11925-2 Surface flame reaction, 30 sec. exposure PN-EN 13823 LP-1064.2.12/34-23/08 PN-EN 13823 LP-1064.2.13/34-20/08 Parameter F s 150 mm FIGRA 0,2 MJ Number of tests 6 Results Continuous parameter average value (m) Compliance (-) Y 51.7 (-) FIGRA 0,4MJ 45.8 (-) LFS < edge (-) Y THR 600s [MJ] 3 2.6 (-) SMOGRA [m 2 /s 2 ] 10.4 (-) TSP 600s [m 2 ] 92.1 (-) FIGRA 0,2MJ 110.2 (-) FIGRA 0,4MJ 110.2 (-) LFS < edge 3 (-) Y THR 600s [MJ] 1.2 (-) SMOGRA [m 2 /s 2 ] 28.9 (-) Certified translation: page 2 of 5 - Register No.: 328 / 2010

CLASSIFICATION REPORT NP-1064.6/08/KP 3/4 TSP 600s [m 2 ] 49.0 (-) (-): not applicable Y: YES N: NO 4. Classification and field of application 4.1 Provision of classification Classification has been provided in accordance with EN 13501-1:2007. 4.2 Classification Classification of the cold storage panel with polyurethane core and visible fixing system for fire reaction: The product acquired additional classification for smoke generation: The product acquired additional classification for flaming droplets/: B s2 d0 Fire properties Smoke generation Flaming droplets B - s 2, d 0 i.e. B-s2,d0 Classification in regard of reaction to fire: B-s2,d0 Present classification is valid for final applications in accordance with technical conditions for buildings and their locations and as for the product which is flame-proof, does not release flaming droplets and does not separate under fire according to the Ordinance of Minister of Infrastructure of 12 April 2002 (Journal of Laws no. 75 of 15 June 2002, pos. 690) and as for product, which does not spread fire inside the building according to ITB Instruction 401/2004 Classification of definitions used in technical-building regulations for classes of reaction to fire in accordance with PN-EN standards ( Przyporządkowanie określeniom występującym w przepisach techniczno-budowlanych klas reakcji na ogień według PN-EN ). Certified translation: page 3 of 5 - Register No.: 328 / 2010

CLASSIFICATION REPORT NP-1064.6/08/KP 4/4 4.3 Field of application Present classification is valid for following parameters that define the product: - panel thickness 120 mm 240 mm, - types of applied coatings: 25μm thick polyester layer Present classification concerns cold storage panel with polyurethane core and visible fixing system described in point 2.2, mounted directly to elements with A1 and A2 class of reaction to fire or in any distance from such elements. Panels are mounted mechanically. 5. Restrictions Granted classification shall remain valid until: - test method is changed, - product standard or technical approval is changed, construction and material changes do not exceed the limits of the field of application specified in point 4.3. Present classification report has been issued in 3 copies. Certified copies can be issued by the ITB Fire Testing Laboratory only upon request of the holder of this report. This classification document is not product approval or product certificate. Signed by: Kamil Perzyna, MSc. Eng. Approved by The Head of Fire Testing Laboratory Mirosław Kosiorek /-/ illegible signature Andrzej Kolbrecki, PhD Eng. /-/ illegible signature Certified translation: page 4 of 5 - Register No.: 328 / 2010

Annex 1 to classification report LP-1064.6/08/KP Page 1/1 cold storage panel with polyurethane core and visible fixing system diagram -- - The above has been faithful rendering into English of the contents of the document in Polish as presented to me for translation. In witness whereof I have set my hand and affixed my seal of office in the City of Gdansk this 20 October, 2010. Ewa Kocik, duly sworn translator and interpreter of Gdansk, ref. no on the list held by the Minister of Justice: 3245/05. Register: 328 / 2010 Certified translation: page 5 of 5 - Register No.: 328 / 2010