MB-T Moisture analyzers

Similar documents
VWR B2T Series Balances

Number of instruction: LMI-11-02/01/08/ENG-C. Moisture analyzer MBC series

User Manual. Moisture Analyzer HE53

Revolutionary Science RS-IF-202

This document hosted by: Instruction Manual MB120 Moisture Analyzer

MOISTURE ANALYZER PMC SERIES

Moisture analyzer PMC series

Instruction Manual MB90 Moisture Analyzer

User Manual. Moisture Analyzer HC103

FagronLab NP-1 UV. Negative pressure workbench. User Manual

Tovatech LLC Phone (973) Rutgers St, Maplewood, NJ 07040

Refrigerated Incubator Model and Operating Instructions

Instruction Manual for the Revolutionary Science RS-IF-203 Incufridge

Ionizer (Static Remover) STABLO-EX Instruction Manual

KERN MFB Type MGE Version GB

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

CERAMIC FAN HEATER URBAN

Operating Instructions. Moisture Analyzer MJ33

SPR7-OS SPR601-OS SCR600L-OS SPR601-OSRC SCR600L-OSRC SP6DSSTB-OS

OPERATING INSTRUCTIONS

ULTRA LOW TEMPERATURE FREEZER. User Manual

Infrared Moisture Determination Balance FD-610. Operating Manual

Countertop Refrigerator

User s Manual. Electric Kettle Model MJ-EK5AEU (UK) Household Use

Halogen Moisture Analyzer

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer

Instruction Manual for the Revolutionary Science RS-PB-200 Dual Poly Pro Bath

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

Cleaning (Preventative Maintenance) on the magicolor 2400 Series

Have a Question? Call toll-free: Owners Manual L WARNING. Project Series Paint Sprayers Important Safety Instructions

Operating Instructions Moisture Analyzer HB43-S

Instruction Manual for the Revolutionary Science RS-PB-100 Poly Pro Bath TABLE OF CONTENTS

Magnetic Stirring Systems with Heat

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

User Manual / Installation Instructions

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Reacti-Therm I and III Heating/Stirring Modules

Pond Pump 280 / 420 / 575. Operating instructions Notice d emploi Instrucciones de uso

TECHNOLOGY IN MOTION MACO PROTECT DOOR LOCKS. Operating and maintenance instructions for door locks END USERS

ISHIDA CO., LTD. Do not carry out installation, operation, service or maintenance until thoroughly understanding the contents of this manual.

METAL CERAMIC FAN HEATER

Operating Manual Bathroom Balance

Note To The User: This product has updated features not yet mentioned in the product manual.

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

Operator s Manual. Histology Bath

ELECTRIC HEATER WITH CARBON FIBER HEATING ELEMENTS

Thermal Electric Wine & Beverage Chiller. Model: WC-20TL (20 Standard Bottle Capacity) Instruction Manual

MiniAmp Thermal Cycler and MiniAmp Plus Thermal Cycler Installation and Operation

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

Laboratory Equipment Pty Ltd Instruction Manual Incubator IWJ Page 1

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

BUILT-IN OVEN MODEL: EBO-E7081D(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

BLAZE ORIGINAL INSTRUCTIONS MANUAL

Operating instructions Electronic Moisture Analyser

Operating instructions Electronic Moisture Analyser

Propane Flame Projector Safety instructions and operating manual

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

OPERATING MANUAL FOR LF-852DII HOT-AIR S.M.D. REWORK STATION

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Quick Start Guide LIQ-QSG-Hx338, Rev M July Rosemount Hx338. Steam Sterilizable and Autoclavable ph Sensor

Moisture Analyzer HB43-S

APPUZO RANGE HOOD INSTALLATION

Instruction Manual. for. Soldering / SMD Rework Station. For Lead-free soldering application and rework on professional SMD electronics.

CARE & CLEANING GUIDE. Bathroom & Kitchen Products

XOE30 XOE36 READ AND SAVE THE INSTRUCTIONS FOR RESIDENTIAL COOKING ONLY

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Damp Locations Wall & Ceiling Mount BEFORE YOU BEGIN

DT/DTH/DR/DRH MERIT SERIES

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

Safety In Chemistry. Identified Risks and Hazards

INSTRUCTION MANUAL FOR

15R HARDWARE INSTALLATION GUIDE

CK247 JDW STEAM MOP Instruction Manual

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

ELECTRIC FIREPLACE HEATER MODEL EF-BLT09 OWNER S MANUAL

Operating Instruction Manual

PPE HAZARD ASSESSMENT CERTIFICATION FORM

Reacti-Therm I and III Heating Modules

USER MANUAL. Version: 1.0. ROBE Show Lighting s.r.o. Czech Republic

Antari Low Fog Machine

Operating manual Electronic Moisture Analyser

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

Operating manual Electronic Moisture Analyser

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

ec Preheater User Manual

BUILT-IN OVEN MODEL: EBO-D7080D(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

Instruction Manual. for. Intelligent Temperature Controlled Soldering Station LF-2000 (U)

2 IN 1 CORDLESS VACUUM

KERN MGD Version GB

The CENTURY. High Performance Oscillating Fan OWNER S GUIDE FOR MODELS 9002X & 9702X

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

INSTRUCTION MANUAL KETTLE

DOUBLE DOOR COMPACT REFRIGERATOR. User Manual MODEL:KSTRC312BW KSTRC312BB

SEVEN STARS LASER DISPLAY SYSTEM USER MANUAL. Big Dipper Laser Science And Technology Co., Ltd REV: 1.02

Transcription:

Start up Guide MB-T Moisture analyzers

To view a complete user manual scan QR code.. CONTENT Moisture Analyzer x Disposable pan x 0 Cross-shaped holder x Drying pan handle x Drying pan shield x Power cord x. UNPACKING TOP 3 Keep the packaging should a warranty claim or service be required.

3. WORKROOM AND BASIC OPERATION GUIDELINES o +40 C o +04 F o +0 C +50 of h w Operate the device in a room where the temperature ranges between 0 40 C (50 04 F) and where the relative humidity is below 80%. Place the balance on a solid surface to ensure stability. To obtain stable and repeatable weighing results, an anti-vibration table is recommended. h 00 cm (39 ) w 0 cm (8 ) w Keep space free around the device: h = min. 00 cm (39 in.), w = min. 0 cm (8 in.). Place the balance away from heat sources. Avoid exposing the balance to the sunlight. Avoid exposing the balance to a magnetic field. Do not weigh magnetic substances. Avoid air drafts and air movements at the workstation. Make sure that the balance is placed on an even surface. Do not place the balance on an unstable surface exposed to shocks and vibrations. Not intended for usage within EX zones. Not intended for weighing explosive or flammable substances. Not to be opened in the course of operation since the heating components reach very high temperature. Be extremely careful while taking the sample out. The sample and the moisture analyzer elements may be hot.

4. ACTIVITIES TO BE DONE PRIOR TO OPERATION Grounding spring check 3 Check the grounding spring. Make sure that the grounding spring juts slightly out of the hole. Remove the base insert. Install the base insert. 5. COMPONENTS ASSEMBLY 3 Slowly rotate the cross-shaped holder, keep rotating until the holder sinks deeper. 4 5

6. PREPARING FOR WORK Place the device at the workstation, wait until it reaches room temperature. 6.. Balance temperature stabilization time COM -4 h Prior switching the device on let it reach room temperature (estimated stabilization time: -4 hours). et USB 405W 0V/ AC 60Hz SB U Ethern Connect the power cord into the AC socket located at the back of the device. Connect the device to the mains. 6.. Balance leveling To level the balance, turn its feet and keep turning the feet until the air bubble takes the central position. 6.3. Switch the balance on The moisture analyzer is ready to operate! It is recommended to carry out adjustment operation prior running to the WEIGHING mode: read point 8.. (adjustment is not required for DRYING). To switch the device on, press ON / OFF key. USB USB Ethe

7. PANEL AND SCREEN 7.. Panel keys Proximity sensor Proximity sensor Entering balance setup Switching on / off Confirming an operation or printing a report Displaying previous screen Taring Zeroing 7.. Home screen Press to display list of working modes: WEIGHING / DRYING List of current working mode functions Status bar Weighing result window Enabled for editing info fields (labels, text boxes, buttons) providing current drying parameters Editable tool bar with quick access keys Parameters Users Database Drying mode Open / Close the chamber Working mode parameters Start Databases

8. BASIC OPERATIONS 8.. Adjustment It is recommended to carry out adjustment operation prior to running the WEIGHING mode (adjustment is not required for DRYING). External adjustment is carried out using an external mass standard of the right accuracy and weight value, which value depends on balance type and capacity. Prior to adjustment prepare the right mass standard. You are recommended to use mass standard of class F or F. View the table and select the mass standard you need. Caution! Make sure that the disposable weighing pan has been installed (read point 5.5.). Do not close the drying chamber in the course of adjustment. Balance model Mass standard [g] MB-T-50H 50 MB-T-50 50 MB-T-0 00 Products Press "Parameters button. 3 0 Respective parameters list is displayed, select Adjustment option. 4 Unload the weighing pan and press button for confirmation. Press "External Adjustment parameter. 5 6 Wait for completion of the start mass determination process. Load the weighing pan with mass standard and press button for confirmation.

7 8 Unload the weighing pan. Wait for the process completion. 8.. Zeroing The balance has been zeroed. Unload the weighing pan and press "Zeroing" button. 8.3. Taring When the weighing result has been displayed press "Tare" button. The balance has been tared.

8.4. Drying profiles / Drying process finish modes Press to view list of drying profiles. Drying profiles: Press to view list of drying process finish modes. Drying process finish modes: Standard: the most precise moisture content measurement Automatic: triggered in accordance with automatic settings Fast: for samples with moisture content between 5% - 5% Manual: triggered manually by the user Mild: for substances sensitive to intense heat impact Time-defined: triggered after passage of declared time Step: for substances with moisture content higher than 5% User-defined: triggered in accordance with user settings

9. SETTINGS Some balance settings are accessible for Administrator exclusively. Prior to balance parameters setup, log in as the Administrator. 9.. Administrator's login Press "Operators" button. Users list is displayed, select Admin option. 4 3 Press 3 button to activate numeric keyboard. Enter "" password and press button to confirm. You have logged in the administrator.

9.. User settings Prior to balance users setup, log in as the Administrator. Press "Databases" button. 3 Select Operator database. 4 Press "Add" button. 5 Select "Name" parameter. 6 Enter user name. 7 Following the above procedure, set remaining parameters: Code: Enter user ID Password: Enter user password Access levels: Set respective access level (user, advanced, admin) User name has been entered.

9.3. Proximity sensors setup Prior to proximity sensors setup, log in as the Administrator. You can assign the proximity sensors with different functions for each working mode (the sensors will trigger different operation for each working mode). The diagram presents sensors setup for the weighing mode. Parameters list is displayed, select Working Modes parameter. Press "Parameters" button. 3 4 Select Proximity Sensors parameter. Select Weighing parameter. 6 5 Select Right Sensor parameter. Select function that is to be assigned to the right proximity sensor. In order to set left sensor function repeat steps 5 and 6, this time select Left Sensor parameter. Following the above procedure you can also set sensors for remaining working modes.

0. SAMPLES AND DRYING METHODS 0.. Preparing samples Optimal sample structure and size are crucial features influencing measurements speed, accuracy and repeatability. Solids: - sample crushing necessary, - sample of low weight required, - large sample surface. Samples with low moisture content: - sample of heavy weight required (0-5 g). Liquids: - large sample surface. 0.. Handling hazardous samples Some sample types require particular caution! They may pose risk for people and objects. It is the moisture analyzer operator who is responsible for potential loss being a result of such samples use. Substances that in the course of heating may emit vapours causing corrosion (e.g. acids). Apply small amount of samples, this helps to prevent risk of depositioning of vapour over cool housing components. Explosive and flammable substances and substances that in the course of heating emit flammable vapours. Apply small amount of samples and lower drying temperature, this helps to prevent flames from rising and explosion. Use glasses and protective gloves. Toxic and corrosive substances and substances that in the course of heating emit toxic vapours. Due to risk of eyes, skin and lungs irritation, and due to risk of death, such samples must be dried in fume cupboard.

. PERIPHERAL DEVICES CONNECTORS Power cord Computer Printer Ambient conditions module Barcode scanner AC DB9 DC RS 3 USB Ethernet USB USB-A RJ45 USB-B Keyboard Barcode scanner Computer Printer Computer Printer

. DEVICE CLEANING.. General Recommendations Use soft cloths made of microfiber, Apply the cleanser onto the cloth first. Prior to cleaning, it is necessary to Avoid applying the cleanser directly disconnect the balance from the mains. natural fiber or man-made fiber. Avoid using abrasive cloths or cloths that might onto the device. scratch the surface. Avoid using cleansers containing chlorine, corrosive chemicals and bleach. Do not use cleansers containing abrasive substances or scouring preparations... Glass components Prior to cleaning the glass panes, it is necessary to disassemble them first. For detailed instruction on panes disassembly, refer to user manual. Clean glass components using a solution of water and detergent (liquid soap, dish-washing detergent, glass cleaner, etc.). In case of heavy contamination, a mild solution of vinegar or baking soda can be used..3. Plastic components Prior to cleaning the plastic housing, it is necessary to disassemble weighing pan components (cover, weighing pan, etc.). Clean plastic components using a solution of water and detergent (liquid soap, dish-washing detergent, glass cleaner, etc.)..4. Stainless steel components Prior to cleaning the stainless steel components, it is necessary to disassemble them first. Clean stainless steel components using a solution of water and detergent (liquid soap, dish-washing detergent, glass cleaner, etc.). In case of heavy contamination, a mild solution of vinegar or baking soda. can be used.

65 East Bunker Court Vernon Hills IL 6006 USA Phone: -800-33-4340 Fax: -847-47-99 E-Mail: sales@coleparmer.com