/WON BuyLine 3726 WON-DOOR. FireGuard. The ORIGINAL horizontal sliding accordion fire door.

Similar documents
Won-Door FireGuard T H E P E R F E C T F I T I N A V A R I E T Y O F A P P L I C A T I O N S

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS

FIREGUARD COLOR CHART

Solutions for Common Problems

Fire Rated Door Assemblies: Compliant Designs

Chapter Nursing Homes

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

Open to Below: A Discussion of Allowed Floor Openings. Jay A. Ierardi, Ph.D., P.E., LEED AP. Kevin S. Hastings, P.E., LEED AP

FIRE/SMOKE BARRIER FUNDAMENTALS

Richard B. Alpert, P.E. Senior FPE, Clark Nexsen

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

Questions related to specific materials, methods, and services will be addressed at the conclusion of the presentation.

3/6/2018. Design Tips For Fire and Smoke Barriers. Professional Development Hours (PDH) Certificates. Copyright Materials

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Building Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1

Life Safety - Means of Egress/Exits NFPA 101

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

Agency for Health Care Administration

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Agency for Health Care Administration

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

Public. Mike Free Health. State of Alabama Department of

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Fire and Smoke Door Inspections Qualified Training 02/03/17

Public Health Fax: Web Site:

January 1, 2014 Mandatory Effective Date

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

American Fire Sprinkler Association. An Introduction to the IBC and IFC

GENERAL AREAS OF INSPECTION

INITIAL FIRE SAFETY ASSESSMENT

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

Agency for Health Care Administration

Presented by: Bill Lauzon, PE Lauzon Life Safety Consulting, LLC Web: Lauzon-LSC.com

INITIAL FIRE ASSESSMENT REPORT (FAR)

Agency for Health Care Administration

BCAC Egress Work Group

Chapter 2: Definitions

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

Code Technologies Committee Report Fire Rated Glazing Group A changes: Fire rated glazing

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Agency for Health Care Administration

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

PERFORMANCE COMPLIANCE METHODS

FIRE SAFETY REQUIREMENTS FOR PRE RESIDENTIAL BUILDINGS OF THREE OR MORE STORIES (DOROTHY MAE ORDINANCE - NO. 158,963)

Basic Fire Door Requirements

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

The Residences at Christina Landing Wilmington, DE

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

ICC CODE CORNER 2012 IFC Code & Commentary

STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

NFPA 80 Overview January 21, 2016

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

INITIAL FIRE SAFETY ASSESSMENT

CHAPTER 7 ALTERATIONS LEVEL

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

2018 International Fire Code. Add new text as follows:

City of South Salt Lake Fire Code Training Exiting, Egress Systems and Egress Control

A U TO S M O K E. Model AUTO SMOKE FIRE SHUT Flat Slats Fire Shut Rolling Doors

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE ASSESSMENT REPORT (FAR)

PHOTOLUMINESCENT EXIT SIGNS EVALUATED AND TESTED TO UL924

9/23/ :47 AM. Second Revision No NFPA [ New Section after ] Submitter Information Verification. Committee Statement

EXIT ROUTES, EMERGENCY ACTION PLANS, AND. FIRE PREVENTION PLANS. PART 1: INTRODUCTION

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

SAF-BCF SECOND REVISIONS WITH STATEMENTS

Fire Department Of New York

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

Report to Adhoc Health Code change proposal regarding locking arrangements From John Woestman, BMHA

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

Richardson Fire Department 136 N. Greenville Avenue, Richardson, TX Telephone: Fax:

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

Osceola County Department of Fire Rescue and Emergency Medical Services

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

STANDARD DETAILS & SPECIFICATIONS Spec No _SI _ Rev. Date 10/20/11

COSTCO, SAN FRANCISCO A PRESCRIPTIVE AND PERFORMANCE BASED ANALYSIS OF FIRE PROTECTION SYSTEMS AND DESIGN

FIRE-RESISTANCE-RATED CONSTRUCTION A Primer on IBC Chapter 7

INSPECTOR I SKILLS ADMINISTRATION

Residential Care Facilities Requirements

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

Agency for Health Care Administration

WORKSHEET 3-1 THE MANITOBA OFFICE OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

El Reno Fire Department Fire Alarm Plan Review Worksheet

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

CODE TECHNOLOGIES COMMITTEE NURSING CARE FACILITIES WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B

Code Technologies Committee Report Elevator Lobby Group A changes: Elevator Lobby

Taming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes JENSEN & HALSTEAD LTD.

Transcription:

08 11 73/WON BuyLine 3726 WON-DOOR FireGuard TM The ORIGINAL horizontal sliding accordion fire door.

Fire Safety by Design Founded in 1962, the Won-Door Corporation introduced the world s most durable acoustically rated folding partition. In 1977 the company pioneered the development of the first-ever accordion type, fire rated horizontal sliding door. Today, more than 40 years later, Won-Door remains the industry leader in the manufacture of fire doors and moveable firewalls. Technology developed by Won-Door engineers continues to influence the building products and fire protection industries. Setting the standard..... 2 Typical applications..... 3 Egress applications..... 4 Non egress applications.. 5 Listings and approvals... 6 Standard features....... 7 How to specify......... 8 W O N - D O O R C O R P O R AT I O N Salt Lake City, UT 84104 Phone: 800-453- 8494 w w w. w o n d o o r. c o m Setting the standard The first to gain universal acceptance The development of the accordion type, horizontally sliding fire door as manufactured by the Won-Door Corporation has had a profound influence on the model code requirements that regulate their use, leading to its universal acceptance for use in virtually any means of egress application. The first to be UL listed The Won-Door FireGuard was the first accordion type fire door to successfully pass nationally recognized tests to withstand the passage of fire. Won-Door FireGuard products are listed by Underwriters Laboratories Inc. (UL) for up to 3 hours as a rated door assembly and 2 hours as a moveable fire wall. Opening protective for a non-rated glass entrance to a tenant suite. Engineered to fit YOUR needs Still on the cutting-edge Only the Won-Door FireGuard uses a state-of-the-art microprocessor activated control system to guarantee reliability and enhance door function. This technology provides almost limitless opportunities for electronic communication, supervision, alarm activation and more. Building codes encourage larger openings so why be limited by traditional forms of opening protectives like roll-down shutters or swing-type doors? The custom-made Won-Door FireGuard fire door can accommodate virtually any opening. Capable of spanning wide openings and heights up to 28 feet* even radial configurations are possible. Best of all, the single- or bi-parting doors are installed in the open position and fold to just inches per foot behind pocket doors Area separation between the old and new BWI Airport terminal. that you can design to blend with the surrounding architecture. 2 * Increased custom heights available WON-DOOR FIREGUARD

08 11 73/WON BuyLine 3726 Superior performance, superior service More than twenty branch sales offices and two Regional Sales Offices, plus a highly skilled team of designers, engineers and field technicians, provide product service and support across the United States. Thoroughly knowledgeable about building code as well as construction, our sales force can be relied upon to guide you every step of the way so you can get your ideas off the drawing board and into existence. Typical applications include: Area Separation Atrium Separation Corridor Separation Elevator Lobby Separation Horizontal Exits Occupancy Separation Safe Areas of Refuge Smoke Barrier Smoke and Draft Control Vertical Exit Enclosure Separation Smoke Compartmentation Stage Proscenium Protective Vertical Opening Protective APPLICATION Elevator Lobby Separation in Type R Occupancy Gold Country Hotel & Casino LOCATION Oroville, California ARCHITECT Varond Design Group Won-Door FireGuard fire doors are used to create unobtrusive, yet code-compliant, elevator lobbies that are compatible with the decor of this high-rise hotel and casino in Northern California. The same Won-Door FireGuard fire doors are used in this elevator lobby/stairwell to satisfy two code enclosure requirements protection of a vertical opening as well as elevator lobby separation. WON-DOOR FIREGUARD 3

Egress Applications Use Won-Door FireGuard in lieu of swing doors APPLICATION Vertical Opening Protective Arizona State University Athletics Facility LOCATION Tempe, Arizona ARCHITECT DWL Architects The architect wanted the natural light from the skylight of this three-story athletic building to filter through colorful banners and illuminate a display of athletic trophies and awards on the first floor. Using Won-Door FireGuard fire doors made this possible. "Fire doors" are not limited to just hollow metal swings. Won-Door FireGuard fire doors are code recognized and accepted anywhere an opening protective is required. Use Won-Door FireGuard in lieu of reducing the size of rated openings Rated openings in fire walls and fire barriers are permitted to be as large as 156 square feet, even in unsprinkled environments. The Won-Door FireGuard provides maximum design flexibility beyond that of any other fire door or shutter. 4 WON-DOOR FIREGUARD

Additional Applications 08 11 73/WON BuyLine 3726 Use Won-Door FireGuard in lieu of shutters By redefining what is typically described as an atrium Won-Door FireGuard fire doors meet the required fire separation between adjacent spaces while eliminating costly atrium requirements such as sprinklers and smoke evacuation systems. Use Won-Door FireGuard in lieu of fire-rated glass APPLICATION Area Separation Provo City Library LOCATION Provo, Utah ARCHITECT MJSA Architects A non-rated clerestory joins the renovated historic 1892 building with a large modern library addition. Combining the old and the new presented a code compliance challenge. Since the aggregate square footage exceeded the allowable area defined in the current code, a 2-hour fire barrier the Won-Door FireGuard was used to separate a large portion of the historic renovation. By taking advantage of the approved wide span opening protective capabilities, historic ambiance and code compliance were easily accommodated. Won-Door FireGuard, the only microprocessor controlled fire door on the market, is the preferred solution for lower cost and clear openings. Some models are approved for use as an ASTM E-119 compliant moveable fire wall in fire barriers. WON-DOOR FIREGUARD 5

Listings & Approvals Means of Egress Applications APPLICATIONS 2003 IBC 1 2006 IBC 1 2006 NFPA 101 Building Code Reference 1008.1.2 exc #5 1008.1.2 exc #6 7.2.1.14 Performance Criteria 1008.1.3.3 1008.1.3.3 7.2.1.14 1 Any application without occupant load limitation except H occupancies. APPLICATION Elevator Lobby Separation/Access Control San Diego International Airport LOCATION San Diego, California ARCHITECT SPGA The Won-Door FireGuard fire door can be used to isolate and control a security breach as well as stop the spread of fire and toxic fumes. Product Information MODEL NUMBER Door Assembly FireGuard FG20 Door Assembly FireGuard FG60 3 Door Assembly FireGuard FG90 3 Door Assembly FireGuard FG180 3 Wall Assembly FireGuard MFW1 4 Wall Assembly FireGuard MFW2 4 Automatic Closing System 5 HOURLY RATING 20 minutes 1 hour 1 1/2 hours 3 hours 1 hour 2 hour Can be used on all Won-Door FireGuard models listed up to 3 hours TEST CRITERIA U.L. 10B (ASTM E-2074) 6 U.L. 10B (ASTM E-2074) 6 U.L. 10B (ASTM E-2074) 6 U.L. 10B (ASTM E-2074) 6 U.L. 263 (ASTM E-119) U.L. 263 (ASTM E-119) U.L. 864 U.L. FILE NUMBER R6799 R6799 R6799 R6799 R12272 R12272 E92690 SINGLE OR BI-PARTING Both Available Both Available Both Available Both Available Single Parting Only Single Parting Only Can be used for both 3 Each door assembly, when required, complies with UL1784; and with the exception of FG20, can be labeled as Temperature Rise (TR). See ESR1394. 4 MFW - Movable Fire Wall 5 This listing applies for use on all Won-Door FireGuard models. 6 Excluding cotton pad test. MAX. OVERSIZE LABEL SIZE 28'0" (h) Unrestricted (w) 28'0" (h) Unrestricted (w) 28'0" (h) Unrestricted (w) 28'0" (h) Unrestricted (w) N.A. N.A. N.A. Other Won-Door FireGuard Listings and Reports ICC Research Rep. ESR-1394 State of California Door Assemblies MFW 3261-357:001; 1080-357:100 San Francisco Dept. of Public Works 387W18.2 City & County of Denver M-8275 State of Wisconsin 811003 City of New York Listed Assemblies MEA-127-79-M; MEA-124-79M; MEA-383-85-M Oversized Assemblies MEA-377-86-M; MEA-70-87-M; MEA-69-87-M 6 WON-DOOR FIREGUARD

Standard Features 08 11 73/WON BuyLine 3726 1 2 6 Standard features of the Won-Door FireGuard: 1. Exiting hardware Exiting hardware can be configured and placed where appropriate, including to accommodate persons with disabilities. 2. Leading edge obstruction detector The door will stop upon contact with an obstacle, pause, then re-seek the closed position. 3. Leadpost Doors can be prevented from closing and caused to re-open a preset distance by applying light pressure to the leadpost. 4. Single- or bi-parting doors A single door slides across the opening into a recessed jamb located on the opposite wall. The spanning of larger openings is possible by using the bi-parting configuration. The storage space is then divided on each side of the opening. 5. Pocket cover door Pocket cover doors can be designed by you to blend with any decor. 6. Track and trolley system This system allows the door to accommodate wide span openings. Curved configurations are also possible. 7. Thermal lockout feature Ambient temperature at the door is monitored and the operating device is automatically disabled if the environment becomes untenable. 8. Microprocessor A control unit located in the door s storage pocket provides continuous monitoring of door status. 9. Electronics The Won-Door FireGuard is a completely electronically supervised system utilizing solid state circuitry as well as a backup DC power supply. 10. Floor gasket and fire liner A tight-fitting floor gasket and fiberglass liner provide an impenetrable barrier against the spread of smoke and flames. 11. Modular design Modular design provides for in-place reparability using basic tools. 12. Materials Door panels are constructed of 24-gauge steel with a standard finish of platinum enamel. Optional colors are available for a nominal fee. 7 8 9 10 11 WON-DOOR FIREGUARD 7

Fire Safety by Choice Specifying the Won-Door FireGuard Why Without the use of floor tracks or exposed hardware of any kind, these fire doors are the most trouble free product in the fire protection industry. Design flexibility Custom made to fit your design without compromising code requirements Lower maintenance costs Modular construction means in-place reparability No parts exposed to wear and tear Fewer service calls Can be reset by building management by simply pushing a button Backup power supply so door operates even during a power outage Increase useable space Code compliant Access control options available Often cost less than other solutions How Our Design Manual containing a complete summary of architectural details and specifications is available for free from your local Won-Door representative. Or call 800-453-8494 to order. The Won-Door FireGuard Product Catalog prepared to standard CSI format for use with most CAD systems is also available for download from our website at www.wondoor.com Additionally, videos, in a variety of formats, can be downloaded from our online video archive. These informative short movies cover a range of topics from typical applications and product demos to technical topics and code compliance. Learn and earn AIA members can learn more about Won-Door products and earn credits by participating in a Won-Door seminar either online or in person. Contact your local representative for more information or visit www.wondoor.com and click on Continuing Education. For more information contact your local representative. W O N - D O O R C O R P O R AT I O N Salt Lake City, UT 84104 Phone: 800-453- 8494 w w w. w o n d o o r. c o m 8 WON-DOOR FIREGUARD