. REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102671575 Date: July 27, 2016 REPORT NO. 102671575CHI-002 TEST OF ONE ROADWAY/AREA LUMINAIRE MODEL NO. APL-NW200 LED MODEL NO. SAMSUNG LH351B DRIVER MODEL NO. MEANWELL HLG-240H-36A RENDERED TO SUPER BRIGHT LEDS, INC. 4400 EARTH CITY EXPRESSWAY SAINT LOUIS, MO 63045 TEST: Electrical and Photometric tests as required to the IESNA test standard. STATEMENT OF LIMITATION: AUTHORIZATION: STANDARDS USED: This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The testing performed was authorized by signed quote number Qu-00709560-5. The following American National Standards or Illuminating Engineering Society of North America Test Guides were used in part or totally to test each specimen: IESNA LM-79-2008: Electrical and Photometric Measurements of Solid State Lighting ANSI NEMA ANSLG C78.377: 2012: Specifications of the of Solid State Lighting Products DESCRIPTION OF SAMPLE: DATES OF TESTS: The client submitted one production sample of model number APL-NW200. The sample was received by Intertek on July 21, 2016, in undamaged condition and one sample was tested as received. The sample designation was AH07212016041538-2. July 26, 2016 through July 27, 2016. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
SUMMARY Model No.: APL-NW200 Description: Roadway/Area Luminaire Criteria Result Total Lumen Output (Lumens) 23684 Total Power (W) 204.4 Luminaire Efficacy (LPW) 115.9 Power Factor at 120Vac 0.995 Power Factor at 277Vac 0.919 Current ATHD % at 120Vac 5.05 Current ATHD % at 277Vac 10.87 Correlated Color Temperature (CCT - K) 5092 Color Rendering Index (CRI - Ra) 73.7 Color Rendering Index (CRI - R9) -31.0 DUV 02 Coordinate (x) 0.343 Coordinate (y) 0.355 Coordinate (u') 0.209 Coordinate (v') 0.486 BUG Rating B4-U0-G3 IES Classification Type I Longitudinal Classification Very Short EQUIPMENT LIST Equipment Used Yokogawa Power Meter Omega Newport Thermometer LSI High Speed Mirror Goniometer Newport Thermohygrometer Pacific, AC power supply Labsphere Spectroradiometer 3 Meter Sphere Elgar AC Power Supply Sorenson DC Power Supply Newport Humidity Recorder Yokogawa Power Meter Omega Temperature Meter Model Control Last Date Calibration Number Number Calibrated Due Date WT210 146919 07/11/16 07/11/17 DPI8-C24 6440T 146920 146928 10/09/15 VBU 10/09/16 VBU iserver 146956 01/04/16 01/04/17 118-ACX CHI0358 VBU VBU CDS1100 CHI0091 VBU VBU SPR600 CHI0088 VBU VBU CW1251M 146112 VBU VBU XFR150-8 146846 VBU VBU ithx-sd 146382 06/27/16 06/27/17 WT1600 146768 01/14/16 01/14/17 MDSi8 146139 03/21/16 03/21/17 Date Used Report No. 102671575CHI-002 2 of 7 Date: July 27, 2016
TEST METHODS Seasoning in Sample Orientation LED Products No seasoning was performed in accordance with IESNA LM-79. Photometric and Electrical Measurements Integrating Sphere Method A Labsphere Model CDS 1100 CCD Array Spectroradiometer and Two Meter or Ten Foot Sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Xitron or Yokogawa Power Analyzer. The calibration of the sphere photometer-spectroradiometer system is traceable to the National Institute of Standards and Technology. Photometric and Electrical Measurements Distribution Method A LSI Type C High Speed Model 6440 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Xitron or Yokogawa Power Analyzer. Some graphics were created with Photometrics Plus software. BUG Ratings (Backlight, Uplight, Glare) for Outdoor Fixtures Only Zonal Lumens were calculated and grouped using the formula in IESNA TM-15-11 for each zone as defined in the BUG addendum. The maximum lumen rating in each zone was compared against the BUG zonal requirements of Energy Star. Photometric Toolbox software was used to calculate results. Report No. 102671575CHI-002 3 of 7 Date: July 27, 2016
RESULTS OF TEST Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) - Integrating Sphere Method Intertek Sample No. AH07212016041538-2 Base Orientatio n Voltage {Vac} Current (ma) Power (Watts) Power Factor UP 12 1711 204.3 0.995 277.0 777.4 197.8 0.919 Current ATHD (%) 5.05 10.87 Correlated Color Temperature (K) 5092 CRI -Ra 73.7 CRI -R9-31.0 DUV 02 CIE 31 Coordinate (x) 0.343 CIE 31 Coordinate (y) 0.355 CIE 76 Coordinate (u ) CIE 76 Coordinate (v ) 0.209 0.486 Spectral Distribution over Visible Wavelengths nm mw/nm nm mw/nm nm mw/nm nm mw/nm nm mw/nm 350 1.902 440 279.3 530 260.5 620 220.1 710 21.56 355 1.879 445 448.7 535 276.2 625 201.4 715 18.69 360 2.044 450 534.7 540 290.3 630 183.0 720 16.20 365 1.884 455 399.6 545 303.8 635 165.0 725 14.14 370 1.690 460 263.5 550 314.6 640 147.8 730 12.21 375 1.567 465 199.5 555 323.6 645 131.7 735 10.61 380 1.537 470 145.8 560 330.5 650 116.7 740 9.205 385 1.582 475 110.1 565 334.9 655 103.0 745 8.013 390 1.770 480 100.4 570 337.2 660 90.49 750 7.002 395 2.269 485 101.3 575 336.8 665 79.06 755 6.124 400 3.104 490 110.3 580 333.4 670 68.93 760 5.423 405 410 415 420 4.946 8.601 15.87 29.79 495 500 505 510 127.9 148.7 169.7 189.4 585 590 595 600 326.9 317.6 304.7 290.7 675 680 685 690 59.96 52.01 45.11 38.93 765 770 775 780 4.757 4.131 3.638 3.203 425 55.70 515 208.9 605 274.8 695 33.71 430 99.61 520 227.3 610 257.6 700 29.01 435 169.8 525 244.5 615 238.9 705 25.04 (mw/nm) 6000 5000 4000 3000 2000 1000 Spectral Data Over Visible Wavelengths 00 350 400 450 500 550 600 650 700 750 800 Nanometers Report No. 102671575CHI-002 4 of 7 Date: July 27, 2016
RESULTS OF TEST (cont'd) Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) Distribution Method Base Absolute Intertek Orientatio Voltage Current Power Power Luminous Flux Sample No. n {Vac} (ma) (Watts) Factor (Lumens) AH07212016041538-2 Up 120.1 1711 204.4 0.994 23684 Lumen Efficacy (Lumens Per Watt) 115.9 Intensity (Candlepower) Summary at 25 C - Candelas Angle 0 25 45 67.5 90 0 7787 7787 7787 7787 7787 5 10 8201 8773 8181 8684 8071 8458 7957 8186 7795 7866 15 20 9727 11363 9510 10856 9025 9946 8528 8983 8013 8228 25 13816 13208 11396 9621 8470 30 35 14621 15073 13890 10534 12070 13836 15574 11989 8872 9427 40 4599 9085 14652 14212 9967 45 922 1472 11074 15870 10866 50 55 704 628 703 612 3469 721 15509 12046 13306 13222 60 65 70 75 80 85 571 513 438 343 252 94 549 488 419 317 200 83 513 419 352 272 184 71 9041 3218 630 264 163 84 13680 10226 2707 556 162 66 90 0 0 0 0 0 Report No. 102671575CHI-002 5 of 7 Date: July 27, 2016
RESULTS OF TEST (cont'd) Illumination Plots Illuminance - Cone of Light Mounting Height: 25 ft. Isoillumination Plot Zonal Lumen Summary and Percentages at 25 C Zone 0-30 0-40 0-60 60-90 0-90 90-180 0-180 Lumens 6887 12090 20793 2892 23684 23684 % Luminaire 29.1 51.0 87.8 12.2 10 10 Luminaire Classification System (LCS) Zonal Lumens and Percentages at 25 C LCS Zone Lumens % Luminaire Zone Lumens % Luminaire FL (0-30) 4342.2 18.3 0-10 744.1 3.1 FM (30-60) 9786.9 41.3 10-20 2242 9.5 FH (60-80) 1312.1 5.5 20-30 3901 16.5 FVH (80-90) 45.3 0.2 30-40 5203 22.0 BL (0-30) 2543.7 10.7 40-50 4648 19.6 BM BH (30-60) (60-80) 4123.1 1501.2 17.4 6.3 50-60 60-70 4054 2393 17.1 10.1 BVH UL (80-90) (90-100) 35.1 0.1 70-80 80-90 418.1 80.3 1.8 0.3 UH (100-180) Total 23689.6 10 BUG Rating: B4-U0-G3 IES Classification: Type I Longitudinal Classification: Very Short Report No. 102671575CHI-002 6 of 7 Date: July 27, 2016
PICTURES (not to scale) X CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determined in this report. In Charge Of Tests: Report Reviewed By: Vladimir Kozak Senior Associate Engineer Lighting Division Timothy Quigley Engineer Lighting Division Attachment: None Report No. 102671575CHI-002 7 of 7 Date: July 27, 2016