CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

Similar documents
Centrifugal Fans, Non-Overloading, Backward Inclined

R. K. Engg. Works Private Limited

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

Selecting the Correct Fan

CML Northem Blower Inc. Air Movement Equipment

an ISO 9001 Company Bulletin PR-112

Industrial Fans & Blowers

Introduction to Fans. The Basics of Fan Principles and Terminology

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

PRODUCT GUIDE THE NEW YORK BLOWER COMPANY

Varius Application of Dynair Fans

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

Ducted Propeller. Airflow Volume

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

An ISO 9001 : 2008 Certified Company SUBURBAN INDUSTRIAL WORKS (LESSEE)

A. Codes and Standards that are Standard at the University:

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

Glossary of Terms Laboratory & Fume Exhaust Fans

ProcessBarron is a leader in the design, fabrication, installation, maintenance, and repair of air, flue gas and bulk materials handling system

DUST COLLECTORS & DOWNDRAFT TABLES. A division of BLOWERS

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Twin City Fan & Blower

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

Centeral Station Air Handling Unit

Model:7530. Specifications. Model ~13.8 FAX: TEL: painting parts. (V) (CFM) System (A) (RPM)

MXI Mixed Flow Inline Fan

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

DAE Systems. Fan Selection Guide. Section 1: Terminology

DOCTOR DOCTOR. Masters of the Winds

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

MJC Mini. Cartridge Filter. Features. Principal specification and options

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

Double Skin Air Handling Units

ENVIRO INTERNATIONAL CORPORATION

Upompe Primeflo XP7 chemical self-priming centrifugal pumps

Fans: Features and Analysis

Enviro International Corporation. WET SCRUBBER

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

1.1 This section applies to air handling units for HVAC Systems.

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

PRODUCT REVIEW. Low Pressure Blowers. Medium Pressure Blowers. High Pressure Blowers. Side Channel Blowers. Conveying Blowers FD RD F

KIC Air Curtains. Technical Guide

SECTION (15833) - HVAC POWER VENTILATORS

TURBO AND HIGH PRESSURE REGENERATIVE BLOWERS

Air Make-Up Units. Product Line Overview & Capabilities

ARI 260 Standard: Sound Rating of Ducted Air Moving and Conditioning Equipment

COMPANY MANAGEMENT TREE

Kice Dust Control System Design and Maintenance Basics Design, Maintenance, & Operation

MECHANICAL VENTILATION

Practical Consideration of Noise from Fans

LEAD RECYCLING PLANT. Battery Machine Manufacturers: Since 1989

ANSI RAB QMS. Parag Energy Efficient Axial Flow FRP Fans


Welcome to Howden. Garden City Range of High Temperature Products

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. ASME/ANSI B73.1 Chemical Process Pump

ENGINEERING LETTER 4

kl-direkt WIND POWER Towers Wet paint overspray Large components Zinc spraying processes Power head Fabrication processes Special edition: Wind Power

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan

WIDEST RANGE OF INDUSTRIAL & AIR CONDITIONER PACKAGED FAN!

Bulletin FH05 FUME EXHAUST

Multistage Centrifugal Blowers/ Exhausters CAST SERIES

Fan Arrangements, Rotation, Discharge and Motor Position

Double Skin Air Handling Units

Boiler Draft Equipment

Vertical Heavy Duty Pumps

WHY SULLAIR? For more information on the IHI-Sullair joint venture, please visit 2,000th IHI-Sullair centrifugal

Understanding Fan System Effects

R. K. Aircon Industries

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

CUSTOM PRODUCTS AND SERVICES GUIDE

MACHINERY BLOCKING RECOMMENDATIONS

BULLETIN G-99. March 2005 CONDENSED CATALOG. Air Moving Products

ROTARY DRYER CONSTRUCTION

MAS AIR SYSTEMS, LLC (724) mas-fan.com PRODUCTS AND SERVICES GUIDE

Small size, big energy savings

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Performance Analysis of Centrifugal Fan by CFD

Venturi wet scrubber VDN Separation of combustible, explosive, humid and adhesive dusts

Proposal Information Template Commercial and Industrial Fans and Blowers 2017 Appliance Efficiency Standards

Goulds Trash Hog. Self-Priming Solids Handling Pumps

Multistage Centrifugal Blowers

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

CAP SERIES SEWAGE AND WASTE WATER PUMPS

Water Pumps. turbo-hydraulic pumps, positive-displacement pumps.

WATER WASH BOOTHS PUMP TYPE PUMPLESS TYPE

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

EXHAUSTO Inc in North America In Atlanta since ,000 sq.ft. office and warehouse 86 authorized sales and service offices in USA and Canada.

Transcription:

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

TM MITTAL ENGINEERING M i t t a l E n g i n e e r i n g i s o n e o f t h e l e a d i n g m a n u f a c t u r e r s q u a l i t y e n g i n e e r i n g e q u i p m e n t i s RSMS ISO IMS IEC certified ISO 9001:2015 company. MITTAL is an independent designer and m a n u f a c t u r e r o f i n d u s t r i a l f a n s & b l o w e r s o v e r t h e l a s t t w e l v e y e a r s a n d h a s t h o u s a n d s o f fans and blower in operation in india and other countries (through our clients). Today our annual turnover is INR 3 crore. T h e c o m p a n y w a s E s t a b l i s h e d i n 2 0 0 5 b y a g r o u p o f e x p e r i e n c e d t e c h n o c r a t o n a s m a l l s c a l e u n d e r t h e a b l e g u i d a n c e o f M r. M a h e s h P a n c h a l. & S u r e s h P a n c h a l S i n c e t h e n o u r endeavour is to strive continually to offer product innovation and quality. Today we offer cost e f f e c t i v e p r o d u c t s w h i c h a r e n o t o n l y e f fi c i e n t b u t r e q u i r e d m i n i m u m m a i n t e n a n c e. M i t t a l M a i n t a i n s s t r i c t q u a l i t y p r o c e d u r e i n d e s i g n, m a n u f a c t u r i n g a n d t e s t i n g. The centrifugal fan is the heart of any thermal system. If the Fan does not deliver required pressure and volume then the System will not work efficiently & Operating cost of the plant w i l l I n c r e a s e. M i t t a l d e s i g n s a n d m a n u f a c t u r e s f a n s f o r w i d e r a n g e o f p r e s s u r e, Vo l u m e & Power to suit customer requirement. Many of the blowers in varying capacities are available in various specifications. However, Mittal specializes in offering tailor made designs as well to suit customer specifications. The various raw materials used by us are Mild Steel, Stainless Steel, Aluminium etc.

INDUSTRIES SERVED ISO Foundry Pharma Iron/steel Textile Ceramics Plastics 90 01 :2 01 5C ert ific ate Furnaces Cotton/Ginning Paper Mill Plywood mfg. Coal Cement Chemical

CENTRIFUGAL BLOWERS MITTAL has developed a series of Blowers for almost all the industrial requirements. Centrifugal Blowers designed and supplied by MITTAL are proven, efficient, reliable & sturdy. These are categorized by their pressure generation capacities & Drive types. Centrifugal Blower / Industrial Blowers can be considered as the heart of any processing industry. It is known as many types like ID Fan, FD Fan, Industrial Blower, High Pressure Fan, Hot Air Circulation fan according to application. MITTAL Supplies following types of impellers bases on application requirement. Radial Blade Backward Curved / Backward Inclined Forward Curved Airfoil Blades -: MITTAL Supplies following types of Blowers bases on application requirement : - LOW PRESSURE BLOWER Generally used as ventilation fans/ gas exhaust fans Single or double inlet styled fans is very efficient & useful for fresh air supply, ventilation. Impellers are Backward Curved or Backward or forward curved type. Fans are generally used for clean air duty. Operating Range: - Air flow (capacity) up to 200000 m3/hr - Motor Kw up to 150 - Static Pressure Range up to 150 mm WC - Material of Construction Casing :Mild Steel, Stainless - RPM generally use Max. up to 1450 - Low Noise Level - Material of Construction Impeller: Mild Steel, Stainless Steel, Aluminium Applications: A low pressure blower is used if the focus is on high air flows and very low pressure. Low pressure blower for industrial applications generates pressures up to 150 mm WC. MEDIUM PRESSURE BLOWERS Generally used as exhausters. These are employed for air containing dust or particles, fiber, flakes & having higher temperatures than ambient. Usually offered in single inlet styled fans are moderately efficient & useful for Creating Draft in Systems. Impellers are Radial Blade or backward inclined or curved blade type having flat or Airfoil designs, with Shrouded or open constructions. Split housings facilitate wheel removal without disturbing connecting ductwork. Operating Range: - Air flow up to 40000 CMH - Motor up to 150 Kw - Static Pressure Range : 100 mm WC to 1000 mm WC - Material Of Construction : Mild Steel, Stainless Steel - RPM variation up to 2500 Rpm - Material of Construction Impeller: Mild Steel, Stainless Steel, Aluminium

HIGH PRESSURE AIR FANS Generally used for combustion and very high Resistance Operating Range Air flow (capacity) range : 100 CMH to 30000 CMH, Static Pressure Range : 600 mm WC to 1800 mm WC, RPM generally 3000 Rpm. Motor up to 150 KW Material Of Construction : Mild Steel, Stainless Steel PLUG FAN Backward-inclined centrifugal wheels are designed to provide efficient and reliable operation for commercial and industrial applications. They are suitable for supply, exhaust, or recirculation systems. In most instances, plug fans are unhoused and rely on the plenum space around the wheel to direct airflow as required in the system. This style of fan is designed with the motor, bearings, and drives out of the airstream, which allows for se in clean, contaminated, or high temperature systems. Operating Range - Volumetric flow capacity up to 150000 m3 /hr - Maximum pressures of 150 mm wc.- - Maximum operating temperature of 300 C - Belt or direct drive Typical Applications - Heating and air conditioning systems - High temperature processes such as ovens, dryers and kilns - Spray booth evaporators and textile dust collectors - Air curtains SQI CENTRIFUGAL BLOWERS Typical applications include conveying, induced draft, industrial ovens, and similar high temperature installations to 300?C. For greater safety in explosive environments, spark resistant construction is offered. Lint-free construction, in which housing hardware is reversed to limit obstructions in the airstream, minimizes lint build-up. OPERATING RANGE - Air flow (capacity) range : 100 CMH to 15000 CMH, - Static Pressure Range : 150 mm WC to 500 mm WC, - RPM variation : 1450-3000, - Motor KW : up to 25, - Material Of Construction : Mild Steel, Stainless Steel TYPICAL APPLICATIONS - Material conveying - Dust collection - Oven exhaust - Dryer exhaust - Paper trim transport DWDI DOUBLE WIDTH, DOUBLE INLET DWDI fans are generally supplied for V-belt drive & Coupling Drive. The wheel is mounted between the bearings and supported by the fan housing. Since both bearings are located in the airstream, standard DWDI fans should be used for clean air applications with air temperatures limited to 130 F. The motor can be mounted in any of the four standard motor positions: W, X, Y or Z.

PP-FRP or MS-FRP BLOWERS PP-FRP Blowers are mostly resistant to weathering, corrosive fumes and gases etc. they are specially designed to for laboratory Ventilation, laboratories to handle highly corrosive gases & fumes. They have been proven suitable for pickling plants and other refining processes, electroplating and pharmaceutical Chemical Industries etc. The fans are also available as per the client requirement. They are available in Direct or V belt driven Types. MS-FRP Centrifugal blowers in capacity range from 500 CMH to 6000 CMH and static heads ranging from 50 mm to 750 mm water column. Our range of pollution control equipment s are centrifugal Blowers, Wet Scrubbers, Fume extraction systems, Venturing Scrubbers, fume stacks etc. Material of Construction: PPFRP, HDPEFRP, PP Blowers. INLINE FAN Inline fans, centrifugal duct fans are the ideal air movers for residential, commercial and industrial applications. The quiet and efficient airfoil impeller is capable of developing significant pressure, and the in-line configuration simplifies installation. The unique motor design, combined with high quality materials and workmanship, results in a truly versatile fan. The in-line configuration of these fans simplifies installation. We also offer these fans as per the customized designs provided by the clients. Motor Mounting Position as Standards CENTRIFUGAL FANS ARE RECOMMENDED BY DRIVE TYPE

TYPES OF IMPELLER BLADES ACCESSORIES OF CENTRIFUGAL AIR BLOWERS Expansion Joints In air ductwork systems, dynamic stresses caused by fan vibrations, temperature fluctuations and other sources can lead to premature equipment failure. Flex duct connectors or expansion joints provide flexibility along duct when connected to rotating equipment to alleviate these stresses. Suction Filter In dust laden areas, inlet filters are recommended so that the fan can suck clean air and discharge at elevated pressure.this will prevent undue clogging of various devices connected in the up-steam of the fan and reduce maintenance. Silencer Silencers can be provided to reduce the noise level of the blower. Mittal designs and manufactures inlet filters with silencers as per discharge of the fan.

Damper Multi-vane damper fitted at the inlet of the fan are used for smooth start up of the fan and pressure control during normal operation. These come with manual and automatic version in various diameters for different capacities. Vibration Isolator : In order to reduce the vibration level at site the fan can be supplied with vibration isolator. Acoustic Cladding In order to reduce the noise level of the fan substantially, acoustic cladding is recommended. This is done though by wrapping casing with suitable material such as glass wool etc. and finally cladding with aluminum foils. Pulley Coupling Tyre Coupling Pin Brush Coupling Composite Pedestal & Plummer block Pedestal Shaft Cooler (Heat Slinger) Cast aluminum shaft cooler dissipates the heat transferred to the shaft from the airstream protecting the fan bearings.

EXTRA FEATURES FOR BLOWERS Available Drives Accessories Optional Accessories Impeller Balancing Impeller directly on motor shaft & driven by motor Impeller Overhung on shaft supported between bearing driven by v-belts/coupling Common channel base for motor & blower, Motor & Blower Pulleys, V-belt, Damper, Expansion Bellow, Motor Slide rails, Belt guard, Induction Motor Standard/FLP. Gland seal, Heat slinger fan, Vibration Isolators, Acoustic insulation, Inlet/Outlet Manual single/multi leaf dampers, Airfoil design High Efficiency Impellers. Dynamically balanced to ISO: 1940-1:2003(E) IS-11723 (Part-1) 1992 Grade 6.3 Available M.O.C Impeller mounting on shaft center between bearings drives by v- belts/coupling. Mild Steel, Stainless Steel (In case Any Specific requirement can be entertain on specific inquiry.) Dynamic Balancing Machine CNC Plasma Cutting Machine Testing of Blowers arrangement

FANS AXIAL FLOW FANS, BIFURCATED FANS, MAN COOLER FAN, PRODUCT COOLING FAN, WALL MOUNT FAN MITTAL ENGINEERS Provides effective air supply or exhaust thro a ducted system requiring high static pressure. Can be connected to a hood & Duct system for effective remote exhaust or filtered ventilation air supply systems. Duct fans in series for tunnel ventilation requiring static pressure up to 7-8 WC. Different blades combination for low noise at higher RPM. Being electrically connected-ready to start Features Sweep Diameter range: 310 to 1200 mm (12 to 48 ) Airflow range : 1000 to 40000 CFM Static Pressure range : 0 to 75 mm WC (0 to 3 WC) Motor Rating Range : 0.5 to 20 HP Drive : Direct / V-belt MOC : MS /SS Rpm : 720 to 1440 Rpm Construction : Complete with heavy casing tube, Motor base, Impellers-Fabricated MS/Al or Cast Aluminum blades (Airfoil). Impeller Balancing : Statically & dynamically balanced to ISO G6.3 Mounting Option : Cooling Axial Fan, Tube Axial Fan (Standing, Wall Mounting, Roof Mounting), Bifurcated Axial Fan (Standing, Wall Mounting), Customized Axial Fan (Couple Driven, V-Belt Driven) Ideally Suitable For Applications Blast ventilation/ exhaust, Comfort for workmen in hot working zones of foundries, Large kitchen exhaust, Furnaces, Ceramic units, Iron & Steel Plant, Power plants, Cement industries, Chemical factories, Plastics molding unit, Mines, tunnel ventilation & exhaust, Metal mfg. plants, Rolling mills, Boiler houses, Fabrication, Assembly shop etc. Tube Axial Fan V-belt Drive Tube Axial Fan Direct Drive Axial Fan Direct Drive Ground Mounting Bifurcated Fan Wall Mounted Man cooler Fan Pedestal Man Cooler Fan

FANS GALLARY TM MITTAL ENGINEERING

TM BLOWER GALLARY MITTAL ENGINEERING

TM BLOWER GALLARY MITTAL ENGINEERING

TM TRANSPORTATION MITTAL ENGINEERING SUCCESSFUL INSTALLATION

ROTATION & DISCHARGE DESIGNATIONS DESIRED BY CLIENT AS VIEWED FROM DRIVE END ARRANGEMENTS

TM MITTAL ENGINEERING -: ADDRESS :- Plot No. 429, Rd Number 11, Kathwada GIDC, Odhav, Ahmedabad -382430, Gujarat-India Contact : +91 9979534374 Phone : +91-(790)-6549 2022 www.mittalblowers.com email : mittalfab@gmail.com An ISO 9001-2015 CERTIFIED