Quick response concealed horizontal sidewall sprinkler VK481

Similar documents
Standard Spray concealed horizontal sidewall sprinkler VK481

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

STANDARD/quick. Sprinkler 42o. August 8, 2011

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK480 TECHNICAL DATA

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

Page 1 of 7. Replaces Form No. F_ Rev 16.3 (Added 16X22 and 18X20 coverage areas)

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

sprinkler vk538 (K11.2)

mirage standard response concealed pendent sprinkler vk492 (K5.6)

Page 1 of 7. Form No. F_ Rev Replaces Form No. F_ Rev 17.1 (added 205deg version)

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

TECHNICAL DATA OBSOLETE

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

freedom residential concealed pendent sprinkler VK488 (K3.0)

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

quick response horizontal sidewall sprinkler vk360 (K8.0)

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

freedom residential concealed pendent lead free sprinkler

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

TECHNICAL DATA. Page 1 of 5

FREEDOM RESIDENTIAL CONCEALED PENDENT LEAD FREE SPRINKLER VK4570 (K4.9) TECHNICAL DATA

TECHNICAL DATA. Page 1 of 6

freedom residential concealed pendent sprinkler vk474 (K5.8)

TECHNICAL DATA OBSOLETE

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

Microfast quick response Fusible element hsw sprinkler

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

standard response fusible link sidewall sprinkler VK112 (K5.6)

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

standard response dry horizontal sidewall sprinklers

December 14, 2015 Page 1 of 7 TECHNICAL DATA

freedom residential concealed pendent Sprinkler vk458 (K7.4)

microfast quick response extended coverage hsw sprinkler vk606

standard response Fusible Link Upright sprinkler VK204 (K8.0)

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

freedom residential flush pendent sprinkler vk476 (K4.9)

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

standard response dry horizontal sidewall sprinklers

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

micromatic Standard response Horizontal Sidewall sprinkler

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

standard response dry horizontal sidewall sprinklers

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

TECHNICAL DATA. The Viking Corporation s Web site at Overall Length (Sprinkler Body): 2-5/16 (59 mm)

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK498 (K5.8) TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

microfast and microfasthp quick conventional sprinklers

microfast sr/qr extended coverage pendent sprinkler

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

quick response Sprinkler 105a October 25, 2010

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

standard response/ quick response extended coverage

micromatic Standard response Horizontal Sidewall sprinkler

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK460 (K5.8) TECHNICAL DATA

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

standard response elo upright sprinkler

standard response large orifice dry

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

freedom residential horizontal sidewall sprinkler Vk450 (k4.2)

standard response elo upright and pendent sprinklers (storage-density/area)

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

Transcription:

February 3, 2012 Sprinkler 63h 1. DESCRIPTION Viking Quick Response Concealed Horizontal Sidewall Sprinkler VK481 is a small solder link and lever spray sprinkler designed for installation on concealed pipe systems. The sprinkler is hidden from view by a low profile, small diameter cover plate installed flush with the wall. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The push-on, pull-off design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and finish has been applied to the wall, while also permitting up to ¼ (6.4 mm) of horizontal adjustment. The cover assembly can be removed and reinstalled, allowing access behind the wall without taking the sprinkler system out of service and removing the sprinkler. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV Refer to the Approval Chart on page 63j and Design Criteria on page 63k for culus Listing requirements that must be followed. 3. technical data Specifications: Available since 2012. Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (1 207 kpa) water working pressure. Thread size: 1/2 (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metric ) Metric K-factor measurement is shown in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Available Cover Plate Horizontal Adjustment: 1/4 (6.4 mm) Overall Length (Sprinkler Body): 2 (50 mm) Patents Pending Material Standards: Sprinkler Body: QM Brass and Brass UNS-C84400 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Seat: Brass UNS-C31400 Deflector Ring: Brass UNS-C23000 Deflector Pins: Stainless Steel UNS-S30200 Halo: Brass UNS-C31400 or UNS-C31600 or Phosphor Bronze UNS-C51000 Flow Shaper: Phosphor Bronze UNS-C51000 Lever Bar Ring: Brass UNS-C31400 or Brass UNS-C84400 Compression Screw: 18-8 Stainless Steel Fusible Link Assembly: Nickel Alloy and Eutectic Solder Fusible Link Levers: Stainless Steel UNS-S31600 Guide Pin: Stainless Steel UNS-S43000 Shipping Cap: Polyethylene Cover Assembly Materials: Cover Plate Assembly: Brass UNS-C26000 or UNS-C26800 Spring: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Special Features: Designed for Light Hazard and Ordinary Hazard Occupancies Viking Technical Data may be found on The Viking Corporation s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Viking Quick Response Concealed Horizontal Sidewall Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. 17555A (includes sprinkler with a protective plastic cap covering the unit). Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 165 F (74 C) = C, 220 F (104 C) = F For example, sprinkler VK481 with a 165 F (74 C) temperature rating = 17555AC. Form No. F_020312 New page 63h-l, issued February 3, 2012.

Sprinkler 63i February 3, 2012 Cover Plate Assembly: Base Part No. 16207 Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/B Temperature Suffix: 135 F (57 C) = A, 165 F (74 C) = C For example, cover 16207 with a Polished Chrome finish and a 165 F (74 C) temperature rating = 16207FC. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Sprinkler Wrenches*: A. Heavy Duty Wrench Part No. 16208W/R* (available since 2010) B. Head Cabinet Wrench Part Number 16267** (available since 2010) C. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) *Requires a ½ ratchet (not available from Viking). **Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. Installation Refer to appropriate NFPA Installation Standards. 5. Operation During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the fusible element to disengage, releasing the sealing assembly. Water flowing through the sprinkler orifice strikes the flow shaper, forming a uniform spray pattern to extinguish or control the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availability Viking concealed sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. Guarantee For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Sprinkler Temperature Classification TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Nominal Temperature Rating 1 Maximum Ambient Ceiling Temperature 2 Ordinary 165 F (74 C) 100 F (38 C) Intermediate 220 F (104 C) 150 F (65 C) Temperature Rating of Cover Assembly (Required) 135 F (57 C) 135 F (57 C) 165 F (74 C) 165 F (74 C) Cover Plate Base Part Number 3 Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, and Painted Black. 1 The sprinkler temperature rating is stamped on the sprinkler body. Footnotes 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 Base part number is shown. For complete part number, refer to Viking s current price list schedule. 16207 16207

February 3, 2012 Sprinkler 63j Approval Chart Quick Response Concealed Horizontal Sidewall Sprinkler VK481 Position with the centerline of the sprinkler located between 4-3/8 and 12-3/8 (112 mm and 314 mm) below the ceiling. Sprinkler Base Part Number 1 SIN NPT Thread Size Nominal K-Factor Maximum Water Working Pressure Overall Length (Sprinkler Body) Listings and Approvals 3,4 (Refer also to Design Criteria on page 63k.) Inch mm U.S. metric 2 Inches mm culus 5 NYC LPCB 17555 VK481 1/2 15 5.6 80.6 175 psi (12 bar) 2 50 AX1, BX1 See Footnote 6. -- -- Sprinkler Temperature Ratings A - 165 F (74 C) B - 220 F (104 C) Cover Plate Assembly Temp. Ratings 7 X - 135 F (57 C) or 165 F (74 C) Cover Part No. 16207 1 Finishes of the Cover Plate Assembly 8 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 Listed for use in Light or Ordinary Hazard Occupancies for use below smooth, flat, horizontal ceilings only. 5 Listed by Underwriter s Laboratories for use in the U.S. and Canada. 6 Meets New York City requirements, effective July 1, 2008. 7 The 135 F (57 C) cover has an orange label. The 165 F (74 C) cover has a white label. 8 Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. Figure 1: Sprinkler VK481 Installation and Correct Use of Wrench

Sprinkler 63k February 3, 2012 culus Listing Requirements: DESIGN CRITERIA (Also refer to the Approval Chart on page 63j.) Quick Response Concealed Horizontal Sidewall Sprinkler VK481 is culus Listed for installation in accordance with the latest edition of NFPA 13 for standard coverage sidewall spray sprinklers as indicated below: Designed for use in Light or Ordinary Hazard Occupancies for use below smooth, flat, horizontal ceilings only. Position with the centerline of the sprinkler located between 4-3/8 and 12-3/8 (112 mm and 314 mm) below the ceiling. THE TOP OF THE SPRINKLER BODY AND THE TOP OF THE INSTALLATION WRENCH ARE MARKED TOP. Orient the top of the sprinkler element parallel with the ceiling as shown in Figure 3. This sprinkler must be installed flush with the wall. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13 for standard sidewall sprinklers. Minimum spacing allowed is 7 ft. (2.1 m). Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. Minimum distance from end walls is 4 in. (102 mm). The sprinkler installation and obstruction rules contained in NFPA 13 for standard coverage sidewall spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Figure 2: Identification of Custom Paint Color for Concealed Covers

February 3, 2012 Sprinkler 63l Figure 3: Sprinkler VK481 Correct Deflector Orientation Figure 4: Sprinkler VK481 Dimensions and Cover Installation

THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_020312 New page 63h-l, issued February 3, 2012.