Heat Pump Air Conditioning Systems

Similar documents
A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

2 &3-4 Head Multi System

designed for air conditioning australian living

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE

Ducted inverter reverse cycle air conditioning

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

Consumer Guide. Split System: Wall Mounted Inverter Heat Pumps

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Modular Air Cooled Scroll Chillers

SET FREE SERIES FSNM(E)

Product Brochure Smart Power. Low Profile Ducted

DUCTED. SYSTEMS Enhanced for superior comfort and smart energy management by AirTouch 3. fordanddoonan.com.au 1800 AIR CON

What do I need for my bedroom?

Cooling Capacity 1.0kW - 8.5kW. Heating Capacity 1.0kW - 9.7kW. Hitachi. Inverter Wall Splits Air Conditioning. Giving you complete control

360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle

SET FREE SERIES FSN2. Technical Catalogue. Outdoor Units: RAS-(8~48)FSN2

Ducted Air Conditioning

DC Inverter Smart VRF Products(R410A)

Product Brochure 2017

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

INVERTER DUCTED SYSTEMS

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

Inverter Ducted Air Conditioners

JUNE & 3-4 Head Multi System

Ducted Air Conditioning

Q Series. Inverter Split Systems

Come home to a warm welcome

DESIGNER RANGE SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

Integrated VarIable refrigerant flow ahu/pau (r410a)

Energy-saving operation

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

Models FSVN FSN FXN KW. set. free. Variable refrigerant flow air conditioning systems R410A

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

Do More With Less

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Wall Split System Air Conditioning

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

Technical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw

DUCTED AIR CONDITIONING SOLUTIONS

ROOFTOP PACKAGED AIR CONDITIONERS

Residential and Light Commercial Ductless Systems Catalog

AIR CONDITIONING REVERSE-CYCLE INVERTER

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

Water Cooled Units HWP 370, 445. Cooling Capacity 36.6kW kW. Heating Capacity 34.9kW kW

TECHNICAL CATALOG HITACHI INVERTER-DRIVEN SPLIT SYSTEM HEAT PUMP AIR CONDITIONERS. - UTOPIA IVX Premium / IVX Standard - Technical Catalog.

Inventor of the Inverter Digital Inverter System

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU

LIFESTYLE R A NGE W A L L M O U N T E D N EW STYLISH, SLIM AN D ELEGANT 5 YEAR F U LL P A R TS & LABOUR W A RRANTY

Ducted Split System Air Conditioners Technical Data

ultimate climate control and advanced energy efficiency THE ESP SERIES

Samsung Free Joint Multi Air Conditioning System

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Innovative air conditioning

Samsung Air Conditioning

DUCTED SYSTEMS AND ZONING SOLUTION

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

FBQ. DC Duct Heat Pump or Cooling Only

Leading edge Add-on cooling for ducted gas heating

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Air Conditioner CONTENTS

Air Conditioner SVC MANUAL(Exploded View)

Braemar superior range of reverse cycle air conditioning

Inverter Ducted Air Conditioners

LG AIR CONDITIONERS Ducted Split System. Quiet & Comfortable with LG HVAC.

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

LV Series. SEER 15+ Concealed Built in Heat Pump

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Wall Mounted. More information on controls and options on pages

LG AIR CONDITIONERS Ducted Split System. Clean, Quiet & Comfortable with LG HVAC.

Just feel well. 2017/2018 Air conditioning

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

Ducted Split System Air Conditioners Technical Data

DESIGNER RANGE SLEEK, MODERN FINISH HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

McQuay HydroflexTM Residential and Light Commercial Chilled Water System

DESIGN & TECHNICAL MANUAL

Technical Data Ducted Three Phase Split System Air Conditioner

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Inverter High Wall MSZ-GE Series

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

DC-INVERTER. Technical Catalog. FSG2Ei HVRG. Heat Pump Air Conditioners. 8~14kW(3~5HP)

Brief exposure to greenery in urban environments can relieve stress levels and your well-being.

PLXSID1605. Warning HEAD OFFICE :

Transcription:

Heat Pump Air Conditioning Systems

Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too. With air conditioning in most cars, and increasingly at home, people are expecting to work, shop and dine in an air conditioned environment. The Hitachi Inverter Utopia range of heat pump air conditioners is designed to provide effective and economical air conditioning for offices, shops and restaurants where wallmounted units are unsuitable. Hitachi Utopia Inverter Heat Pump range The range uses the same outdoor units but there are two distinct types of indoor unit: RCI Series Cassette Units Cassettes, which fit into the ceiling, are usually ideal for air conditioning large open areas such as shops, meeting rooms and restaurants RPI Series Concealed Ducted Units Ducted units, which fit above the ceiling, or under the floor, use ducting and diffusers to distribute conditioned air. 2 features DC Inverter technology Hitachi Inverters are designed to reduce electricity usage as much as possible by self-adjusting their output up and down as conditions vary through the day to ensure only the minimum power, and no more, is used at any particular time to maintain a consistent air temperature. 6 Year Warranty HITACHI HEAT PUMPS 6YEAR WARRANTY I N C R E A S I N G YOUR COMFORT The Utopia range is reliable, thoroughly tested and built to last and carries a 6 Year Parts & Labour warranty which is backed by Temperzone Ltd the NZ distributor of Hitachi heat pumps and the leading air conditioning manufacturer in Australasia. Auto-changeover control Hitachi air conditioners heat and cool and as conditions alter Auto-control changes the unit from heating to cooling automatically, as required, to maintain the temperature without intervention from the user. Quiet Operation The units are extremely quiet. They have been designed using the latest noise reduction techniques to ensure they are not at all intrusive. Non-toxic Refrigerant The system uses R410A refrigerant which is non-flammable, non-toxic and with zero depletion.

Fresh Air Input Fresh air from outside is essential, indeed required, in business premises. Both the Cassettes and the Ducted units are designed to be able to draw air from the outside and mix it in with conditioned air to ensure there is always a proportion of fresh air in the air supplied. Functional controllers Depending on the controller chosen each unit can be controlled independently or as part of a group of up to 16. Add-ons are also available to enable the units to be switched on/off by external devices such as time clocks and fire alarms. Self demand Control Units are able to accept inputs from external controls to restrict electrical power consumption at certain times e.g. during a high usage period. Power consumption Electric power consumption is controlled by self demand control. This function keeps the current set value. Central Controls Secure the full capacity in the specified range. Morning Daytime Night Operating Time Set current value. This set current value can be selected 50, 70 or 100% of the rated value. A fully-programmable centralised 7 day timer is available to switch all units on/off automatically to conserve power at times when there are not people normally working in the area e.g. in the weekend. Central controls are available for control of up to 128 air conditioning units (refer back page). 3 RPI Series: Concealed Ducted Type Provided there is sufficient space to install the unit ducted units are often the air conditioning unit of first choice because of their versatility; a) Conditioned air can be supplied exactly where it is needed in a space b) It is capable of air conditioning more than one room c) It does not use up valuable wall space and diffusers can be positioned to fit around lighting and other services to suit your interior design e) It is the quietest available type of heat pump f) For convenience of servicing It does not necessarily have to be located above the air conditioned area The Utopia RPI Ducted range; a) Has the most up-to-date Inverter technology b) Comes in 5 sizes ranging from 7 to 18kW cooling and 8 to 18.6kw heating. c) Supplies heating down to -15 C ambient d) Has between 120 to 140 Pa external static pressure available. e) Has up to 77 m outdoor/ indoor pipe length and 30 m elevation f) Self-diagnostic function for easy servicing g) Has a separable indoor unit for ease of installation.

RPI Series: Fan Performance Note: Airflow (m3/min) x 16.66 = Airflow (l/s) 4

SPECIFICATIONS - DUCTED INVERTER SYSTEMS Model: Indoor Unit RPI-3.0FSN1SQ RPI-4.0FSN1SQ RPI-5.0FSN1SQ RPI-6.0FSN1SQ RPI-7.0FSN1SQ Model: Outdoor Unit RAS-3HVRNS RAS-4HVRNS RAS-5HVRNS RAS-6HVRN RAS-7HVRN CAPACITY Cooling Capacity (kw) 7.1 9.9 12.5 15.7 18.0 Range (kw) 3.9 ~ 8.0 4.9 ~ 11.2 5.7 ~ 14.0 6.7 ~ 16.0 8.1 ~ 20.0 Heating Capacity (kw) 7.6 10.8 13.6 15.2 18.6 Range (kw) 4.0 ~ 9.0 5.0 ~ 12.5 6.0 ~ 16.0 6.7 ~ 16.0 8.1 ~ 20.0 ELECTRICAL Power Supply 240V ac 1 phase 50 Hz Power Attachment IU via OU or IU and OU separately Interconnecting Wires 0.75 m 2 x 2 shielded twisted pair Running Current RUN / max. 10.8 / 18 14.7 / 22 18.5 / 31 23.2 / 29 26.0 / 31 Recommended External Protection (A) 25 32 40 40 40 EFFICIENCY Power Input - Cooling (kw) 2.4 3.5 4.4 5.4 5.9 Power Input - Heating (kw) 2.4 3.1 3.8 4.0 5.4 EER Cooling 2.96 2.85 2.84 2.91 3.05 COP Heating 3.17 3.43 3.58 3.80 3.44 AIRFLOW Fan Speeds 3 External Static Range (Pa) 70-120 70-120 70-120 70-120 140 Air Flow (l/s) Hi / Med / Low 484 / 433 / 333 600 / 550 / 417 783 / 717 / 567 933 / 833 / 667 1084 / 950 / 767 Compressor Type Scroll DIMENSIONS & WEIGHTS Dimensions IU (H x W x D mm) 350 / 1076 / 800 350 / 1076 / 800 350 / 1300 / 800 350 / 1300 / 800 440 / 1430 / 550 Weight IU (kg) 52 57 61 63 75 Dimensions OU (H x W x D mm) 600 x 792 (+95) x 300 800 x 950 x 370 800 x 950 x 370 1240 x 950 x 315 1650 x 1100 x 390 Weight OU (kg) 44 85 89 97 167 DUCT CONNECTIONS Supply Air Connection (mm) 980 x 220 980 x 220 1205 x 220 1205 x 220 830 x 300 Return Air Connection (mm) 813 x 306 813 x 306 813 x 306 935 x 306 1288 x 402 NOISE LEVELS Sound Pressure Level IU (db(a)) Hi / Med / Low 45 / 43 / 39 47 / 44 / 40 48 / 45 / 42 52 / 48 / 44 51 / 47 / 42 Sound Press. Level OU (db(a)) Cool (Night) Heat 48 (46) 50 50 (48) 52 52 (50) 54 48 (44) 50 53 (50) 54 INSTALLATION Refrigerant Type R410A Pipe Connection Sizes: Suction (mm) 16 (5/8 ) 16 (5/8 ) 16 (5/8 ) 16 (5/8 ) 19 (3/4 ) Pipe Connection Sizes: Liquid (mm) 10 (3/8 ) 10 (3/8 ) 10 (3/8 ) 10 (3/8 ) 10 (3/8 ) Refrigerant Pipe Charge Length (m) 20 20 30 30 30 Max. Pipe Length (m) 30 50 50 77 50 Max. Pipe Lift (m) OU Higher / OU Lower 30 / 20 Pipe Connection Method flare WORKING RANGE Outdoor Operating Temp. (Cooling) C db -5 to +46-5 to +43 0 to +46 Outdoor Operating Temp. (Heating) C wb -10 to +15-15 to +15-8 to +15 5 NOTES: 1. The nominal cooling capacity is based on the JIS standard B8616: Cooling Operation Conditions Indoor Air Inlet Temperature : 27 C DB, 19.0 C WB Outdoor Air Inlet Temperature : 35 C DB Heating Operation Conditions Indoor Air Inlet Temperature : 20 C DB Outdoor Air Inlet Temperature : 7 C DB, 6 C WB Published capacities based on Piping Length: 7.5 m. Control Systems Models Wired Control PC-AR *1 Wired Control incl. 7 day timer PC-ART *1 Central 7-Day Timer PSC-A1T Central Controller (up to 160 units) PSC-A64S Plug Kit for remote input/output PCC-1A Note: *1: Does not include a remote control cable. 2. The sound pressure level is based on following conditions. Indoor Units: 1.5 m beneath the unit with discharge duct (2.0m) and return duct (1.0m) in an anaechoic chamber. Outdoor Units: 1 m from the unit service cover surface, and 1.5 m from floor level. Optional Parts Indoor Units Drain Kit 500mm lift *2 Outdoor Units Drain Kit NOTES: *2. For models up to RPI-6. Models DUPI-162S DBS-26 Note: Specifications are subject to change with product improvement and without notification. Specification details provided in this brochure are indicative only. Please refer to the Hitachi Design and Installation manuals for all technical information.

RCI Series: Cassette Type Four-way airflow Cassettes, which fit right into the ceiling, are an economical and effective way of air conditioning open areas with high occupancy or traffic, such as shops, walkways, and restaurants a) They are usually located centrally within the conditioned area b) They do not use valuable wall space c) Suit ceiling heights up to 4.2 m d) Provide excellent general air conditioning 6 The Utopia RCI Cassette range... a) Has the most up-to-date inverter technology b) Comes in 3 sizes ranging from 7 to 12.5 kw cooling and 8 to 14 kw heating c) Supplies heating down to -10 C ambient d) Has an attractive fascia with a wide louvre to prevent smudging on the ceiling e) Is 4-way airflow as standard but can be modified to 2 or 3-way. f) Has a one-touch panel which can be swung open 90 with just one push so the filter can be removed for cleaning g) The unit is equipped with an internal drain pump (850 mm lift) to remove accumulated condensation water from the drain pan even while it is operating. An electronic sensor monitors the water level and automatically activates the pump as necessary. h) Has the option of fitting a ducted air outlet. Optional Parts

SPECIFICATIONS - CASSETTE INVERTER SYSTEMS Model: Indoor Unit RCI-3.0FSN2 RCI-4.0FSN2 RCI-5.0FSN2 Model: Outdoor Unit RAS-3HVRNS RAS-4HVRNS RAS-5HVRNS CAPACITY Cooling Capacity (kw) 7.1 10.0 12.5 Range (kw) 3.9 ~ 8.0 4.9 ~ 11.2 5.7 ~ 14.0 Heating Capacity (kw) 8.0 11.2 14.0 Range (kw) 4.0 ~ 9.0 5.0 ~ 12.5 6.0 ~ 16.0 ELECTRICAL Power Supply) 240V ac 1ph. 50 Hz Power Attachment IU via OU or IU and OU separately Interconnecting Wires.75 m 2 x 2 Shielded twisted pair Running Current (Cooling) RUN / max. 10.3 / 18 14.7 / 22 18.5 / 31 Recommended External Protection (A) 25 32 50 EFFICIENCY Power Input - Cooling (kw) 2.3 3.3 4.2 Power Input - Heating (kw) 2.4 3.2 4.1 EER Cooling 3.06 3.01 3.00 COP Heating 3.29 3.48 3.45 AIRFLOW Fan Speeds 3 Air Flow (l/s) Hi / Med / Low 350 / 300 / 250 533 / 467 / 400 567 / 483 / 417 Compressor Type Scroll DIMENSIONS & WEIGHTS Dimensions IU (H x W x D mm) 298 / 840 / 840 298 / 840 / 840 298 / 840 / 840 Weight IU (kg) 26 29 29 Dimensions OU (H x W x D mm) 600 x 792 (+95) x 300 800 x 950 x 370 800 x 950 x 370 Weight OU (kg) 44 85 89 NOISE LEVELS Sound Pressure Level IU (db(a)) Hi / Med / Low 32 / 30 / 28 38 / 35 / 33 39 / 37 / 35 Sound Press. Level OU (db(a)) Cool (Night) Heat 48 (46) 50 50 (48) 52 52 (50) 54 INSTALLATION Refrigerant Type R410A Pipe Connection Sizes: Suction (mm) 16 (5/8 ) 16 (5/8 ) 16 (5/8 ) Pipe Connection Sizes: Liquid (mm) 10 (3/8 ) 10 (3/8 ) 10 (3/8 ) Refrigerant Pipe Charge Length (m) 20 20 30 Max. Pipe Length (m) 30 50 50 Max. Pipe Lift (m) OU Higher / OU Lower 30 / 20 Pipe Connection Method flare WORKING RANGE Outdoor Operating Temp. (Cooling) C db -5 to +46 Outdoor Operating Temp. (Heating) C wb -10 to +15 7 NOTES: 1. The nominal cooling capacity is based on the JIS standard B8616: Cooling Operation Conditions Indoor Air Inlet Temperature : 27 C DB, 19.0 C WB Outdoor Air Inlet Temperature : 35 C DB Heating Operation Conditions Indoor Air Inlet Temperature : 20 C DB Outdoor Air Inlet Temperature : 7 C DB 6 C WB Published capacities based on Piping Length: 7.5 m. 2. The sound pressure level is based on following conditions: Indoor Units: 1.5 m beneath the unit in an anaechoic chamber (JIS 8616) Outdoor Units: 1 m from the unit service cover surface, and 1.5 m from floor level. Voltage of the power source for the indoor fan motor is 220V. Control Systems Models Wired Control PC-AR *1 Wired Control incl. 7 day timer PC-ART *1 Central 7-Day Timer PSC-A1T Central Controller (up to 160 units) PSC-A64S Plug Kit for remote input/output PCC-1A Wireless Control PC-LH3A Wireless Receiver kit PC-ALH Note: *1: Does not include a remote control cable. DC Inverter systems are designed for efficiency in compliance with MEPS II standards. Efficiency ratings in this table are based on physical test data. Specifications are subject to change with product improvement and without notification. Specification details provided in this brochure are indicative only. Please refer to the Hitachi Design and Installation manuals for all technical information. Optional Parts Indoor Units Fresh Air Intake with filter kit Fresh Air Intake direct to unit *2 Conditioned Air Duct Outlet Blanking Plate *3 Outdoor Units Drain Kit NOTES: *2. Does not include a filter. *3. For converting to 2 or 3 way outlet. Models OACI-232 PD-75 (Ø75) PDF-46C3 PI-23LS5 DBS-26

Remote Controls, H-Link Intelligent controls Hitachi style flows through to the sleek, LCD wall-mounted controls which reflect the sophistication of the Utopia DC Inverter systems. PC-AR Wall Controller Large LCD display. Controls all indoor unit functions (mode, temp., fan speed, etc.) Operates 1 to 16 indoor units (same settings). Master & slave controllers possible. On/Off/Sleep countdown timers Programmable automatic off time Numerous parameters and locks programmable Setting of remote input & output functions Error code diagnosis in real time On board thermistor H-LINK H-Link II is a communication system available to building owners and occupiers to control multiple outdoor and indoor units from one control point. Its use assists installers and service engineers during commissioning and service maintenance. A Hitachi Central Controller (eg PSC-A646), a standard PC or building management system such as BACnet or LonWorks can provide central control via the H-Link II network. Hitachi VRF, Split Systems, Chillers and even Wall Mounts (via an interface card) can be connected to H-Link II. PC-ART Wall Controller with 7 Day Timer Includes all the features of the PC-AR plus... 7 day, 24 hour timer 4 intervals programmable per day Night setback of up to 5 C possible Power failure backup remembers settings for 2 weeks H-LINK Refrigerant Pipe HARC 40 PC PC-ARH Half Sized Wall Controller Small size for discreet applications Simplified functions include temp., mode and fan speed. Operates 1 to 16 indoor units (same settings) Error code diagnosis Transmission Line Refrigeration Pipe Outdoor Units PC-LH3A Wireless Controller Standard infrared controller Controls temp., mode, fan speed, etc. On/Off countdown timers Multiple units can be operated with one controller Requires receiver to be added to indoor unit Not applicable to all models CS-NET Remote Controllers Indoor Units PSC-A1T Central 7 Day Timer Controls up to 64 groups of units (max. 160 indoors). 3 intervals programmable per day for each group Separate winter and summer schedules can be pre-set Power failure backup remembers settings for 2 weeks PSC-A64S Central Controller Provides individual control (mode, temp., fan speed, etc.) of multiple indoor units. Controls up to 64 groups of units (max. 160 indoors). External inputs/outputs for: central stop/run input, emergency stop input, demand control (DRED) input, central operation output and central alarm output. *6 years parts and labour. 3 years on high usage applications, e.g. computer server rooms. Terms and conditions apply to all warranties. Hitachi Inverter systems are designed for efficiency and are compliant to MEPS II standards. Specifications are subject to change with product improvement and without notification. Specification details provided in this brochure are indicative only. Please refer to the Hitachi Design and Installation manuals for all technical information. Your local Hitachi dealer: Peace of Mind Temperzone Ltd distributes Hitachi heat pumps throughout New Zealand. Hitachi heat pumps from temperzone have a 6 year warranty* on parts and labour. HITACHI HEAT PUMPS 6YEAR WARRANTY I N C R E A S I N G YOUR COMFORT It s a comfort to know that this warranty is backed by Temperzone Ltd, the largest air conditioning manufacturer and exporter in Australasia: founded, owned and operated by New Zealanders since 1956. 3544 03/11 www.hitachiheatpumps.co.nz distributed by